Particle/Powder Analysis Instruments
Filter
Showing 331–360 of 969 results
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 |
| Minimum Detectable Spot Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Inspection Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Output | ≥ 6000 lumens |
| Light Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |
| Sample Carriers | 200 × 200 mm transparent tray (for pellets) and direct platform placement (for films) |
| Compliance | ASTM D7252, ISO 18064, GB/T 29187, USP <788> (particle inspection principles), GLP-compliant data audit trail support |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP-BS-1908 |
| Price | Upon Request |
| Minimum Detectable Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Inspection Area | ≥ 200 × 200 mm |
| Tray Dimensions | 200 × 200 mm (net usable area) |
| Optical Magnification | >20× |
| Light Output | ≥6000 lumens |
| Light Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Overall Dimensions | ~459 × 426 × (276 + 380) mm |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 |
| Minimum Detectable Spot Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Detection Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Output | ≥ 6000 lumens |
| Illumination Source | 24 V / 60 W |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |
| Sample Tray Size | 200 × 200 mm (net usable area) |
| Brand | HunterLab |
|---|---|
| Origin | Canada |
| Model | SP-BS-1908 Powder Particle |
| Minimum Detectable Size | 0.1 mm |
| Detection Accuracy | < 0.035 mm |
| Scanning Area | ≥ 200 × 200 mm |
| Optical Magnification | >20× |
| Light Source | 24 V / 60 W |
| Illuminance | ≥ 6000 lm |
| Power Supply | 220 V, 50 Hz |
| Dimensions | ~459 × 426 × (276 + 380) mm |
| Brand | INPROCESS-LSP |
|---|---|
| Origin | Netherlands |
| Model | NanoFlowsizer |
| Particle Size Range | 10–1000 nm |
| Size Reproducibility | ±2 nm |
| Temperature Range | −10 to 125 °C |
| Temperature Control Accuracy | ±0.5 °C (−10 to 85 °C), ±2.0 °C (85 to 125 °C) |
| Optical Signal Frequency | 76 Hz |
| Measurement Principle | Spatially Resolved Dynamic Light Scattering (SR-DLS) |
| Sample Concentration Range | Unrestricted |
| Minimum Sample Volume | ≥100 µL |
| Zeta Potential Range | Not applicable (dedicated particle sizing only) |
| Measurement Time | <10 s per acquisition |
| Key | Brand: Insment |
|---|---|
| Model | KS-554B |
| Origin | Shanghai, China |
| Compliance | YY 0469-2011 Annex B, ASTM F2100, ASTM F2101, EN 14683 |
| Control System | PLC with 7-inch WELIN 16:9 touchscreen HMI |
| A/B Sampling Flow Rate | 28.3 L/min ±2.5% (0.1 L/min resolution) |
| Nebulizer Flow Rate | 8–10 L/min ±5.0% (0.1 L/min resolution) |
| Peristaltic Pump Flow Range | 0.006–3 mL/min ±2.5% (0.001 mL/min resolution) |
| Aerosol Chamber Negative Pressure | −90 to −120 Pa ±2.0% (0.1 Pa resolution) |
| Cabinet Negative Pressure | −50 to −200 Pa |
| Aerosol MMAD | 3.0 ±0.3 µm, GSD ≤1.5 |
| Andersen Cascade Impactor Stages | 4-stage (Stage I >7 µm, II: 4.7–7 µm, III: 3.3–4.7 µm, IV: 2.1–3.3 µm) |
| HEPA Filter Efficiency | ≥99.99% @ ≥0.3 µm |
| Data Storage Capacity | >100,000 test records |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Noise Level | <65 dB(A) |
| Brand | IST Switzerland |
|---|---|
| Origin | Switzerland |
| Model | DiaShape |
| Measurement Range (Digital Microscopy) | 2.5 µm – 1 mm |
| Measurement Range (Film Scanner) | 20 µm – 5 mm |
| Shape Parameters per ISO 9276-6 | Aspect Ratio, Ellipticity, Extent, Roundness, Convexity |
| Optical Characterization | Transparency, Color |
| Reporting | Histograms, Cumulative Distributions, Log/Linear Plots, Mean/Median/Std Dev |
| Software | DiaShape PRO with Customizable Filters, Calibration Tools, User-Defined Workflows, Audit-Ready Data Logging |
| Power Supply | 110/220 V, 50/60 Hz |
| Dimensions | 60 × 30 cm |
| Weight | 8 kg |
| Brand | IST Switzerland |
|---|---|
| Origin | Switzerland |
| Model | Powdershape |
| Measurement Range | 2.5 µm to 3 cm |
| Configurations | Powdershape MF, Aqua, Automatic, Standard, Light |
| Sample Modes | Dry & Wet (Aqua), Manual & Automated Feeding |
| Key Output Parameters | Equivalent Circle Diameter, Maximum Feret, Minimum Feret, Aspect Ratio, Convexity, Solidity, Color Distribution, Elongation, Roundness |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-6100-B |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 2000 µm |
| Repeatability | <1% (D50 of standard reference material) |
| Measurement Time | <10 s typical |
| Compliance | ISO 13320:2009, GB/T 19077–2016 |
| Detector Channels | 87-channel high-density crossed array with area compensation |
| Optical Model | Full-range Mie scattering theory with dynamic multiple-scattering correction |
| Laser Source | Sealed fiber-coupled semiconductor laser, λ = 650 nm, P > 10 mW |
| Data Acquisition | 16-bit, 200 kHz sampling rate |
| Feed System | Motorized stepless-speed feeder with software-controlled oil-free silent air compressor (integrated moisture and particulate filtration) |
| Operating Environment | 0–45 °C, 10–85% RH (non-condensing) |
| Power Supply | 110–240 V AC ±20 V, 50–60 Hz |
| Dimensions | 700 × 495 × 300 mm |
| Weight | 35 kg |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-N9 |
| Origin | Shanghai, China |
| Laser Wavelength | 532 nm (LD-pumped, temperature-stabilized) |
| Detection Angle | 90° |
| Detector | Hamamatsu Photomultiplier Tube (PMT) with Single-Mode Polarization-Maintaining Fiber |
| Sample Cell | 10 mm × 10 mm quartz cuvette, 4 mL capacity (temperature-controlled) |
| Measurement Range | 1–10,000 nm (sample-dependent) |
| Concentration Range | 0.1–100 mg/L |
| Accuracy | <1% (vs. NIST-traceable standard reference materials) |
| Repeatability | <1% (RSD of mean diameter) |
| Temperature Control Range | 8–45 °C (±0.1 °C stability) |
| Correlator | Custom ASIC-based high-speed photon correlator |
| Data Analysis | Cumulant method + regularized non-negative least-squares (NNLS) inversion |
| Output | Z-average diameter (d<sub>Z</sub>), polydispersity index (PDI), intensity-weighted size distribution, volume/mass distribution (derived), full exportable distribution tables and plots |
| Measurement Time | <60 s per run (excluding dispersion preparation) |
| Compliance | GB/T 29022–2012, ISO 22412:2008 |
| Dimensions | 390 × 255 × 240 mm |
| Power | AC 100–260 V, 50/60 Hz, max. 80 W |
| Operating Environment | 15–40 °C, 20–70% RH, non-condensing |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-N9 |
| Principle | Dynamic Light Scattering (DLS) / Photon Correlation Spectroscopy (PCS) |
| Measurement Range | 1–10,000 nm |
| Concentration Range | 0.1–100 mg/L |
| Accuracy | <1% (NIST-traceable standard samples) |
| Repeatability | <1% (NIST-traceable standard samples) |
| Laser Source | 532 nm LD-pumped solid-state laser with integrated temperature stabilization |
| Detector | Hamamatsu single-photon-counting photomultiplier tube (PMT) coupled via single-mode polarization-maintaining fiber |
| Scattering Angle | 90° |
| Correlator | Custom ASIC-based high-speed digital photon correlator |
| Sample Cell | 10 mm × 10 mm square quartz cuvette, 4 mL volume, Peltier-controlled (±0.1 °C) |
| Data Analysis | Cumulant method + regularized non-negative least-squares (NNLS) inversion |
| Output | Z-average diameter (d<sub>Z</sub>), polydispersity index (PDI), intensity-weighted size distribution histogram & tabular data |
| Temperature Control Range | 8–45 °C |
| Measurement Time | <60 s per run (excluding dispersion) |
| Dimensions | 390 × 255 × 240 mm |
| Power Supply | AC 100–260 V, 50/60 Hz, max. 80 W |
| Operating Environment | 15–40 °C, 20–70% RH, non-condensing |
| Compliance | GB/T 29022–2012, ISO 22412:2008 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB5100-H |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1 µm – 600 µm |
| Repeatability | ≤0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <10 s per run (excluding dispersion conditioning) |
| Compliance | ISO 13320:2020, GB/T 19077–2016 |
| Laser Source | Fiber-coupled semiconductor laser, λ = 635 nm, output power >10 mW |
| Detector Channels | 70-channel high-density photodiode array |
| Optical Alignment | Motorized auto-centering system (0.2 µm step resolution, full alignment in ≤15 s) |
| Ultrasonic Dispersion | Frequency 40 kHz, power adjustable 0–80 W, dry-run protection integrated |
| Circulation System | Flow rate 0–10 L/min, variable speed pump (100–33950 rpm), sample volume ≥120 mL (optional micro-mode: ≥10 mL) |
| Sample Cell | Boiling-type dispersion cell (190–600 mL capacity), quick-release quartz window, dew-point monitoring sensor, bubble-free optical path design |
| Enclosure | Sealed dust- and shock-resistant chassis |
| Optional Configurations | Chemical-resistant wetted parts (acid/alkali/solvent compatible), GLP-compliant audit trail module |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB5500-L |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1 µm – 1000 µm |
| Repeatability | < 0.5% |
| Measurement Time | < 10 s per analysis |
| Compliance | GB, ASTM, ISO, JIS, DIN, CNS |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB6100-A |
| Origin | Shanghai, China |
| Disperser Type | Wet Dispersion System |
| Measurement Range | 0.01 µm – 2000 µm |
| Repeatability | <0.5% RSD (D50 of NIST-traceable standard reference materials) |
| Measurement Time | ≤10 s per analysis (optical acquisition only) |
| Detector Channels | 121 |
| Laser Source | Dual-beam, fiber-coupled, λ = 650 nm, P > 10 mW |
| Optical Path Calibration | Fully automated real-time alignment |
| Compliance | ISO 13320:2020, GB/T 19077–2016, ASTM D4294–22 (applicable for colloidal & suspension systems) |
| Sample Handling | Self-cleaning fluidic path with zero residual carryover |
| Environmental Design | Dust- and shock-resistant chassis |
| Brand | Jihepu (Jinan Hepu) |
|---|---|
| Origin | Shandong, China |
| Model | JH-AS |
| Price Range | USD 700 – 1,400 |
| Power Supply | AC 220 V ± 22 V, 50 Hz ± 1 Hz |
| Frequency | 3000 or 6000 cycles/min |
| Amplitude Range | 0–3 mm (continuously adjustable) |
| Max. Sieve Stack Height | 400 mm (8 × 50 mm sieves) |
| Sieve Diameter Options | 200 mm or 300 mm |
| Display | Digital LED |
| Operating Modes | Subtle vibration / Continuous vibration |
| Sample Type Compatibility | Dry and wet sieving |
| Max. Mesh Size | ≤325 mesh |
| Net Weight | 35 kg |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Wet-Dispersion Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 2000 µm |
| Repeatability | <1% RSD (D50) |
| Measurement Time | ≤10 seconds per run |
| Dispersing Medium Volume | ≥180 mL (standard), optional 10 mL micro-circulation mode |
| Ultrasonic Power | 100 W with dry-run protection |
| Optical Alignment | Fully automated mechanical–optical dual-axis centering (≤15 s, 0.2 µm step resolution) |
| Detector Channels | 121 |
| Compliance | ISO 13320:2020, GB/T 19077–2016, USP <429>, FDA 21 CFR Part 11 ready (with audit trail, electronic signature, role-based access control) |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Wet-Dispersion Laser Particle Size Analyzer |
| Measurement Range | 0.1–300 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <120 s per run |
| Dispersion Method | Wet dispersion with integrated ultrasonication, stirring, and circulation |
| Laser Source | λ = 639 nm, P > 2 mW |
| Ultrasonic Frequency | 40 kHz, Power: 60 W (adjustable duration) |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL (optional 10 mL micro-cell) |
| Compliance | GB/T 19077–2016, ISO 13320:2009, Q/0100JWN001–2013 |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Winner311XPPLUS |
| Price Range | USD 14,000–21,500 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–100 µm |
| Repeatability | >99% |
| Measurement Time | 10–120 s |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Winner 318 |
| Price Range | USD 14,000–21,000 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 4.6–2000 µm |
| Repeatability | <1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–120 s |
| Optical Principle | Fraunhofer Diffraction |
| Laser Source | LD-pumped solid-state laser, λ = 532 nm, P > 40 mW |
| Detector Channels | 60 |
| Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Measurement Zone Length | Adjustable from 1 to 10 m |
| Optical Alignment | 3-axis motorized micrometer stage (±20 mm translation, ±20 mm vertical lift, ±20° rotation) |
| Lens Protection | Dual-air-curtain system |
| Dimensions (L×W×H) | 500 × 254 × 520 mm (main unit) |
| Weight | 45 kg + 23 kg |
| Software | WinPAS v5.x with real-time spatial mapping, multi-scattering correction, and cross-sectional distribution analysis |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | 802 |
| Price Range | USD 14,000–28,000 (FOB) |
| Particle Size Range | 1–10,000 nm |
| Repeatability | ≤1% (D50 of NIST-traceable standard reference material) |
| Temperature Control Range | 5–90 °C |
| Temperature Stability | ±0.1 °C |
| Light Scattering Angle | 90° |
| Detection Method | Dynamic Light Scattering (DLS) |
| Sample Volume | 1–4 mL |
| Sample Concentration Range | 0.1–100 mg/L |
| Laser Source | Adjustable-power 532 nm semiconductor laser (1–40 mW) |
| Detector | Hamamatsu photomultiplier tube (PMT) |
| Correlator | CR256 digital autocorrelator (256 channels, 100 ns–10 ms delay resolution) |
| Measurement Time | <5 minutes per run |
| Compliance | GB/T 19627–2005, GB/T 29022–2012, ISO 13321:1996, ISO 22412:2008 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China-made) |
| Model | JS94HM / JS94H2M / JS94JM / JS94J2M / JS94KM / JS94K2M |
| Zeta Potential Range | ±3000 mV |
| Measurement Accuracy | ±5% |
| pH Range | 0.000–14.000 (Resolution: 0.1 pH unit) |
| Temperature Range | −5.0 to 105.0 °C (Resolution: 0.1 °C |
| Recommended Operating Range | 5–35 °C) |
| Sample Volume per Measurement | 0.5 mL |
| Optical System | Semiconductor-based near-field illumination (blue/green wavelength), 1200× digital magnification |
| Voltage Polarity Switching Time | 0.30–1.20 s (adjustable) |
| Power Supply | 220 V AC, 50 Hz, 150 W |
| Brand | Jingxin (Chengdu Jingxin Instrument Co., Ltd.) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | JL-1198 |
| Price | Upon Request |
| Particle Size Range | 1 nm – 10,000 nm |
| Size Measurement Repeatability | ≤1% (D50 of NIST-traceable standard) |
| Temperature Control Range | 0–45 °C |
| Temperature Stability | ±0.002 °C |
| Correlation Time Resolution | 20 ns – 100 ms |
| Measurement Principle | Dynamic Light Scattering (DLS) / Photon Correlation Spectroscopy (PCS) |
| Sample Introduction | Wet Dispersion with Recirculating or Static Cell |
| Sample Volume (Static) | 2.5 mL |
| Sample Volume (Recirculating) | 500 mL |
| Concentration Range | 10 adjustable gain levels (ppm to 40% v/v) |
| Zeta Potential Range | ±500 mV |
| Measurement Duration | 1–5 min per run |
| Molecular Weight Estimation Range | 1 kDa – 10 MDa (via calibration) |
| Laser Source | Dual 30 mW solid-state lasers (405 nm) |
| Detection Geometry | Transmission mode (90°), Reflection mode (160°) |
| Detector | High-gain, low-noise photomultiplier tube (PMT) |
| Channels | 4000 autocorrelation channels |
| Delay Time Range | 50 ns – 100 ms |
| Ultrasound Dispersion | 60 W integrated probe |
| Dimensions | 740 × 360 × 530 mm |
| Weight | ~60 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, <85% RH non-condensing |
| Brand | Jingxin (Chengdu Jingxin Instrument Co., Ltd.) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.01–3000 µm |
| Measurement Time | ≤10 s per analysis |
| Optical Principle | Full-Range Mie Scattering Theory |
| Detector Channels | 128 |
| Repeatability | ≤1% (D50 deviation against NIST-traceable standard reference materials) |
| Accuracy | ≤1% (D50 deviation) |
| Laser Source | Imported 650 nm semiconductor laser, 30 mW output, >70,000 h lifetime |
| Fourier Lens Diameter | 80 mm |
| Signal Interface | RS232 + USB (up to 100 m transmission distance) |
| Host–Slave Separation Distance | 1–10 m (field-adjustable) |
| Operating System Compatibility | Windows XP / 7 / 10 |
| Environmental Requirements | 5–35 °C, <85% RH |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Brand | Jingxin (Chengdu Jingxin Instrument Co., Ltd.) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | JL-3000 |
| Price Range | USD 21,000–28,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 3000 µm |
| Repeatability | ≤1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | 10–30 s per analysis |
| Measurement Principle | Full-range Mie Scattering Theory |
| Detector Channels | 128 |
| Optical System | Fourier Transform with 80 mm aperture lens |
| Laser Source | Imported semiconductor laser, 650 nm, 30 mW, >70,000 h lifetime |
| Host-Follower Separation Distance | 1–10 m (adjustable) |
| Data Interface | RS-232 and USB (up to 100 m transmission) |
| Software Compatibility | Windows XP / 7 / 10 |
| Environmental Operating Conditions | 5–35 °C, <85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Brand | Jingxin (Chengdu Jingxin Instrument Co., Ltd.) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Laboratory Instrument |
| Model | JL-6000 |
| Price Range | USD 17,000–23,000 (FOB Chengdu) |
| Dispersion Method | Dry and Wet Dispersion |
| Instrument Type | Benchtop Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 3000 µm |
| Repeatability | <3% (D50 of NIST-traceable standard reference materials) |
| Measurement Time | ≤120 s (wet mode) |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JB-400H |
| Pricing | Available Upon Request |
| Brand | Jiubin |
|---|---|
| Model | JB-400H |
| Origin | Shanghai, China |
| Die Diameter | Φ2.095 ± 0.005 mm |
| Die Length | 8.000 ± 0.025 mm |
| Barrel Diameter | Φ9.550 ± 0.007 mm |
| Barrel Length | 152 ± 0.1 mm |
| Piston Head Diameter | 9.474 ± 0.007 mm |
| Piston Head Length | 6.350 ± 0.100 mm |
| Standard Test Loads (8 levels) | 0.325 kg to 21.600 kg (3.187 N to 211.82 N |
| Temperature Range | Ambient to 450 °C |
| Temperature Stability | ±0.2 °C |
| Control System | PLC-based |
| Human-Machine Interface | 5-inch color touch screen |
| Display | LCD |
| Report Output | Thermal printer support |
| Melt Cutting Modes | Manual / Time-controlled / Automatic |
| Test Method | Gravimetric (MFR) |
| Dimensions (L×W×H) | 250 × 350 × 510 mm |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB6100-B |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Wet) | 0.01 µm – 2000 µm |
| Repeatability | ≤ ±0.5% |
| Measurement Time | 10 s |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB6100-D |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.01 µm – 1250 µm |
| Repeatability | <1% |
| Measurement Time | 60 s per test |
| Brand | Jingke Ruida (Kyocera-associated distribution channel) |
|---|---|
| Origin | Beijing, China |
| Model | JK-JG7000 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.01–780 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference materials) |
| Laser Source | He-Ne laser (632.8 nm, >2 mW) + auxiliary diode laser (650 nm, >2 mW) |
| Detector Channels | 77 |
| Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Ultrasonic Dispersion | 40 kHz, 35 W |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL |
| Auto-alignment | Four-phase hybrid stepper motor system |
| Analysis Modes | Free distribution, Rosin-Rammler, log-normal, and sieve-based grading |
| Output Formats | BMP, TXT, DOCX, XLSX |
| Software Interface | English & Chinese (localization-ready) |