Particle/Powder Analysis Instruments
Filter
Showing 151–180 of 969 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BI-ZTU |
| Pricing | Available Upon Request |
| pH Range | 2–12 |
| Sample Cell Option | Flow-Through Cell |
| Pump Tubing | 1 mm (0.04") ID, Compatible with Teflon®, PEEK®, and EPDM® |
| Included Accessories | Integrated pH Electrode + Four 100 mL Reagent Bottles |
| Drive System | Four Independent Peristaltic Pumps |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BioDLS |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Particle Size Range | 0.5 nm – 3 µm (sample-dependent) |
| Molecular Weight Range | 4 × 10² – 2 × 10⁷ Da (sample-dependent) |
| Concentration Range | 0.1 – 100 mg/mL (sample-dependent) |
| Sample Volume | 2 µL |
| Throughput | Up to 768 samples per run (2 × 384-well plates) |
| Temperature Control | Sample cell: 5–90 °C |
| Storage plate | Ambient to 4 °C |
| Laser Source | 35 mW, 635 nm solid-state laser (optional 30 mW, 850 nm) |
| Scattering Angle | 90° |
| Detector | Avalanche Photodiode (APD) |
| Correlator | 522 physical channels, 10¹⁰ linear channels, dynamic sampling/delay range: 25 ns – 1310 s |
| Interface | USB 2.0 & 1.1 |
| Software | Windows XP/Vista compatible |
| Dimensions (w/d/h) | 300 × 510 × 630 mm (28 kg, no storage cooler) |
| Operating Environment | 10–75 °C, 0–95% RH (non-condensing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FOQELS |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 90Plus PALS |
| Price Range | USD $12,500 – $37,500 |
| Zeta Potential Range | −500 to +500 mV |
| Particle Size Range | 0.3 nm – 6 μm |
| Electrophoretic Mobility Range | 1×10⁻¹¹ to 1×10⁻⁷ m²/V·s |
| Conductivity Range | 0–30 S/m |
| Temperature Control | −5 °C to 110 °C (±0.1 °C) |
| Laser Source | 35 mW Solid-State Diode Laser |
| Detection | PMT or APD |
| Scattering Angles | 15° and 90° |
| Correlator | 4×522 physical channels, 4×10¹¹ linear channels |
| Electrode | Open-configuration permanent palladium electrode |
| Sample Volume (Zeta) | 0.18–1.5 mL |
| Sample Volume (Size) | 1–3 mL |
| pH Measurement Range | 1–14 |
| Molecular Weight Range | 342–2×10⁷ Da |
| Software | Particle Solution™ v5.x (GLP-compliant with audit trail, electronic signature support per 21 CFR Part 11) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 90Plus Zeta |
| Price Range | USD 14,000 – 42,000 |
| Particle Size Range | 0.3 nm – 6 µm |
| Zeta Potential Range | −500 mV to +500 mV |
| Electrophoretic Mobility Range | 1×10⁻¹⁰ – 1×10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 20 S/m |
| Temperature Control | −5 °C to 110 °C (±0.1 °C) |
| Laser Source | 35 mW Solid-State Diode Laser |
| Detection | PMT or APD |
| Correlator | 4×522 physical channels, 4×10¹¹ linear channels |
| Scattering Angles | 15° and 90° |
| Sample Volume (Zeta) | 0.18–1.5 mL |
| Sample Volume (Size) | 1–3 mL |
| Electrode | Open-geometry, palladium-based permanent electrode |
| pH Range | 1–14 |
| Electric Field Strength | 0–3.2 kV/m |
| Software | Particle Solution™ for simultaneous size, zeta, and molecular weight analysis |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | 173Plus |
| Particle Size Range | 0.3 nm – 10 μm |
| Concentration Range | 0.1 ppm – 40% w/v |
| Typical Accuracy | ±1% |
| Sample Volume | 10–3000 μL (with 10 μL & 50 μL micro-cells) |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Temperature Control | −5°C to 120°C (±0.1°C stability) |
| pH Range | 1–14 |
| Laser Source | 40 mW solid-state laser (optional 5 mW He-Ne) |
| Detector | Avalanche Photodiode (APD) |
| Correlator | 4×10¹¹ linear channels, dual-channel cross-correlation support |
| Scattering Angles | 13°, 90°, and 173° (motorized, software-selectable) |
| Optional Modules | Micro-rheology, Zeta Potential, In-line Process Monitoring, Automated Titrator, Dielectric Constant Meter, Viscometer, 21 CFR Part 11 Compliant Software |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 173Plus |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Size Analyzer |
| Measurement Range | 0.3 nm – 10 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 15°, 90°, 173° |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ Linear Channels, Dual-Channel Cross-Correlation Support |
| Sample Volume | 0.01–3 mL (with optional 50 µL and 10 µL micro-cells) |
| Molecular Weight Range | 342–2×10⁷ Da |
| pH Range | 1–14 |
| Software Compliance | 21 CFR Part 11 Ready |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook 90Plus |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Sample Volume | 10–3000 µL |
| Laser Source | 40 mW Solid-State Laser |
| Detector | PMT or APD |
| Correlator | 4×10¹¹ Linear Channels, 4-Channel Input, Dual Cross-Correlation Support |
| Scattering Angles | 15° and 90° Options |
| Zeta Potential Option | Available |
| Software Compliance | 21 CFR Part 11 Audit Trail Mode |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90plus PALS |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Zeta Potential Measurement Principle | Phase Analysis Light Scattering (PALS) |
| Temperature Control Range | −5 °C to 110 °C (±0.1 °C) |
| Scattering Angles | 15° and 90° |
| Laser Source | 40 mW Solid-State Laser (He-Ne Optional) |
| Detector | APD or PMT |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Sample Volume | 10 µL – 3 mL (with 10 µL & 50 µL micro-cells) |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoBrook 90Plus Zeta |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Size Range | 0.3 nm – 15 µm |
| Repeatability | ±1% |
| Measurement Time | 1–2 min |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook Omni |
| Dispersion Method | Wet Dispersion |
| Particle Size Range | 0.3 nm – 15 µm |
| Repeatability | <1% |
| Measurement Time | 1–2 min |
| Scattering Angles | 13°, 90°, 173° |
| Zeta Potential Technique | Hardware-Based Phase Analysis Light Scattering (PALS) |
| Concentration Range | 0.1 ppm – 40% w/v |
| Temperature Control | −5 °C to 120 °C (±0.1 °C) |
| Sample Volume | 10 µL – 3 mL |
| Laser Source | 40 mW Solid-State Laser (optional 5 mW He-Ne) |
| Detector | APD |
| Correlator | 4×10¹¹ linear channels, 4-channel input, dual cross-correlation support |
| Electrophoretic Mobility Range | 10⁻¹¹ – 10⁻⁷ m²/V·s |
| Conductivity Range | 0 – 30 S/m |
| pH Range | 1 – 14 |
| Molecular Weight Range | 342 – 2×10⁷ Da |
| Optional Compliance | 21 CFR Part 11 Software Module |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook ZetaPALS |
| pH Range | 1–14 |
| Temperature Range | −5 to 110 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±1% |
| Repeatability | ±1% |
| Electrophoretic Mobility Range | 1×10⁻¹¹ to 1×10⁻⁷ m²/V·s |
| Particle Size Range (optional DLS) | 0.001–100 µm |
| Sample Volume | 0.018–1.5 mL |
| Conductivity Range | 0–30 S/m |
| Electric Field Strength | 0–3.2 kV/m |
| Laser Source | 40 mW solid-state laser (wavelength & power customizable) |
| Detector | PMT or APD |
| Electrode Material | Palladium (corrosion-resistant open-cell capillary electrode optional) |
| Brand | Brookhaven |
|---|---|
| Origin | USA |
| Model | NanoBrook ZetaPlus |
| Zeta Potential Range | ±500 mV |
| pH Range | 1–14 |
| Temperature Range | −5 to 110 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | ±1% |
| Repeatability | ±1% |
| Particle Size Range (Electrophoretic Mode) | 0.001–100 µm |
| Sample Volume | 0.18–1.5 mL |
| Conductivity Range | 0–20 S/m |
| Electrophoretic Mobility Range | 1×10⁻¹⁰ to 1×10⁻⁷ m²/V·s |
| Electric Field Strength | 0–3.2 kV/m |
| Electrode Material | Palladium (corrosion-resistant, open-cell design) |
| Laser Source | 35 mW solid-state laser (optional 5 mW He–Ne) |
| Detector | PMT or APD |
| Automated Trend Analysis | time-, temperature-, pH-, and conductivity-dependent |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NanoDLS |
| Dispersion Method | Wet & Dry Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 0.5 nm – 3 µm (refractive index dependent) |
| Repeatability | ≤1% (typical) |
| Measurement Time | <10 s per acquisition (configurable) |
| Sample Volume | 2.5 µL |
| Max Operating Pressure | 400 bar (5,880 psi) |
| Concentration Range | 0.1–100 mg/mL |
| Temperature Control Range | 25–80 °C |
| Laser Source | 35 mW, 638 nm solid-state laser |
| Detector | Avalanche Photodiode (APD) |
| Scattering Angle | 90° |
| Interface | USB 2.0 & 1.1 |
| Data Output | Hydrodynamic diameter distribution (intensity-, number-, and volume-weighted), Gaussian & multimodal fitting, real-time aggregation kinetics plots |
| Operation Mode | Auto-sampling or manual injection |
| Optional Integration | BI-MwA multi-angle static light scattering module for SEC-MALS coupling |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Omni |
| Price Range | USD 42,000 – 70,000 |
| Brand | CALDEE |
|---|---|
| Origin | Shaanxi, China |
| Model | OPC |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering (7th Generation) |
| Detection Range | 1–150 µm |
| Number of Channels | 8 |
| Calibration Standards Supported | ISO 4406, NAS 1638, GJB 420B, GOST 17216, SAE AS4059, ISO 11171, MIL-STD-1246C, IP 564/565, GB/T 14039, DL/T 432, JB/T 9737 |
| Accuracy | ±1 contamination grade |
| Maximum Online Pressure | 0–0.6 MPa (standard), 0–31.5 MPa (with pressure-reducing valve) |
| Viscosity Range | 0–400 cSt |
| Flow Rate | 20–100 mL/min |
| Operating Fluid Temperature | −10 °C to +80 °C |
| Output Interfaces | RS232, RS485, analog (4–20 mA / 0–5 V optional), alarm relay |
| Reporting | particles/mL + ISO/NAS/GJB contamination grade |
| Compliance | Designed for GLP/GMP-aligned environments |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | Calibus-1 |
| Price | Upon Request |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | GSA |
| Density Measurement Range | 0.9000–1.0500 g/cm³ |
| Particle Size Range | 0.001–0.1 mm |
| Sample Capacity | 12 simultaneous measurements |
| Temperature Compensation | Automatic, based on Stokes’ law |
| Repeatability | < 2% RSD |
| Compliance | ASTM D422, ISO/TS 17892-4 |
| Programmable Parameters | Soil density, gravitational acceleration, data acquisition interval, sedimentation duration |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | WFA-840D / WFA-860D / WFA-840E |
| Stirring Positions | 4 / 6 / 4 |
| Speed Range (rpm) | 10–300 / 10–300 / 0–200 |
| Speed Resolution | 1 / 1 / 1 rpm |
| Speed Accuracy | ±1 / ±1 / — rpm |
| Display | LED / LED / Scale + Knob |
| Backlight | Yes / Yes / Yes |
| Timer Range | 0–99 h or 0–999 min / OFF or 0–99 h or 0–999 min / 0–30 min or Continuous |
| Power Consumption | 11 W / 19 W / 6 W |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China-made) |
| Model | JL Series |
| Pricing | Available Upon Request |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | ≥99% |
| Measurement Time | ≤2 minutes |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–200 µm |
| Repeatability | ≤1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | ~60 seconds per sample |
| Dispersion Method | Wet dispersion with 60 W ultrasonic probe |
| Sample Cell | 60 mm × 60 mm fused quartz |
| Circulation System | Integrated stainless-steel (304) 500 mL dispersion tank with peristaltic pump and mechanical stirrer |
| Optical Design | Inverted Fourier optical system |
| Detector | 52-channel multi-element photodiode array |
| Light Source | 650 nm, 30 mW semiconductor laser (lifetime >70,000 h) |
| Software | Windows-compatible analysis suite with volume/number distribution, D10/D50/D90, specific surface area, and GLP-compliant data export (PDF, CSV) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | ≤1% (D50 deviation vs. NIST-traceable standard reference materials) |
| Measurement Time | ≤2 minutes per sample |
| Dispersion Method | Wet dispersion with integrated 60 W ultrasonic probe and mechanical stirring |
| Optical System | Inverted Fourier configuration with dual-wavelength laser sources (650 nm / 30 mW primary |
| Detector Array | 98-channel high-resolution photodiode array |
| Sample Cell | 60 mm × 60 mm optical-grade fused silica window |
| Dispersant Volume | 500 mL stainless steel (304) dispersion chamber |
| Compliance | GB/T 19077–2016, ISO 13320:2020, ASTM E799–22 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | JL-1177 |
| Price Range | USD 21,000–22,500 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01 µm to 3000 µm |
| Repeatability | ≤1% (D50 deviation against NIST-traceable standard reference materials) |
| Measurement Time | ≤120 s per sample |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | JL-1177 |
| Price Range | USD 11,200–14,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 3000 µm |
| Repeatability | <1% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <120 seconds |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | JL-1178 |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Repeatability | <1% (RSD for D50) |
| Measurement Time | ≤10 s per sample |
| Test Principle | Mie Scattering & Fraunhofer Diffraction |
| Detector Array | 128-channel multi-element photodetector |
| Light Source | Dual-wavelength semiconductor laser (650 nm / 30 mW primary |
| Optical Design | Inverted Fourier optical system with auto-aligned f-theta lens |
| Air Pressure Range | 0.1–0.8 MPa (adjustable) |
| Sample Mass | 2–10 g per test |
| Operating Environment | 5–35 °C, AC 220 V ±10%, 50 Hz |
| Compliance | GB/T 19077–2016, ISO 13320:2020 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Dispersion Method | Dry Air Jet Dispersion |
| Repeatability | ≤3% (D50 deviation against national standard reference materials) |
| Measurement Time | ≤60 seconds per sample |
| Optical Principle | Mie Scattering & Fraunhofer Diffraction |
| Detector Array | 128-channel multi-angle photodetector |
| Light Source | Dual-wavelength semiconductor laser (650 nm / 30 mW primary |
| Sample Consumption | 2–10 g per test |
| Dispersion Pressure | Adjustable 0.1–0.8 MPa |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C |
| Compliance | GB/T 19077–2016, ISO 13320 |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 1 nm – 3000 µm |
| Repeatability | ≤1% RSD for D50 (micron- and nano-grade reference standards) |
| Measurement Time | 2–3 minutes per sample |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JL-1197 / JL-1198 |
| Price Range | USD 21,000–28,000 (FOB) |
| Particle Size Measurement Range | 1 nm – 3000 µm |
| Measurement Repeatability | ≤1% (D50 deviation against NIST-traceable standard materials) |
| Operating Temperature Range | 5–40 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Optical Signal Sampling Frequency | 100 Hz |
| Sample Introduction Method | Fully Integrated Wet Dispersion Circulation System |
| Sample Volume Requirement | 0.1–5 mL per test (dependent on density, refractive index, and particle morphology) |
| Test Duration | 2–5 minutes per sample (automated sequence) |
| Detection Principle | Dual-mode — Photon Correlation Spectroscopy (PCS) for sub-100 nm particles |
| Detector Configuration | 128-element multi-channel photomultiplier tube array with high-gain, low-noise amplification |
| Optical Architecture | Inverted Fourier optical system with dual-laser path (635 nm semiconductor laser, >70,000 h lifetime) |
| Data Output Formats | CSV, PDF, TXT, XML |
| Software Language Options | English or Simplified Chinese UI |
| Compliance | Meets ISO 13321 (PCS), ISO 13320 (Laser Diffraction), and GB/T 19077–2016 (Chinese national standard for particle size analysis) |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | JL-3000 |
| Price Range | USD 14,000–21,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Measurement Time | 10 s per analysis |
| Measurement Principle | Full-range Mie Scattering Theory |
| Optical System | Parallel-beam Fourier Configuration with f-Theta Lens |
| Light Source | Imported Semiconductor Laser, 650 nm, 30 mW, >70,000 h Lifetime |
| Detector | 128-channel Multielement Photodiode Array |
| Repeatability Error | ≤3% (D50 of NIST-traceable Standard Reference Material) |
| Accuracy Error | ≤3% (D50 of SRM) |
| Main Unit to Auxiliary Unit Spacing | 400 mm |
| Dimensions (L×H×W) | 1130 × 340 × 200 mm |
| Weight | ~50 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, RH <85% |
| Data Output | Cumulative Distribution, Frequency Distribution, D10/D50/D90/D97, Mean Diameter, Specific Surface Area |
| Trigger Options | Software-initiated, TTL-level, or External Switch Trigger (up to 50 full analyses/sec) |
| Interface | RS-232 and USB 2.0 (transmission distance up to 100 m) |
| Software Compatibility | Windows XP / 7 / 10 |
| Language Support | English and Chinese UI |
| Data Export | PDF, CSV, XML, and direct print |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | JL-3000 Integrated |
| Price Range | USD 14,000–21,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3000 µm |
| Measurement Time | 10 s per analysis |
| Measurement Principle | Full-range Mie Scattering Theory |
| Optical System | Fourier Transform with Parallel Beam & Large-Diameter Lens |
| Detector | 128-channel Multielement Photodiode Array |
| Laser Source | Imported Semiconductor Laser, 650 nm, 30 mW, >70,000 h Lifetime |
| Repeatability Error | ≤3% (D50 of NIST-traceable Standard Reference Material) |
| Accuracy Error | ≤3% (D50 of NIST-traceable Standard Reference Material) |
| Main Unit–Auxiliary Unit Spacing | 400 mm |
| Dimensions (L×H×W) | 1130 × 340 × 200 mm |
| Weight | ~50 kg |
| Power Supply | AC 220 V ±22 V, 50 Hz ±0.5 Hz |
| Operating Environment | 5–35 °C, RH <85% |
| Data Output | Cumulative Distribution, Frequency Distribution, D10/D50/D90/D97, Mean Diameter, Specific Surface Area |
| Trigger Options | Software Command, TTL Pulse, Mechanical Switch (up to 50 Hz acquisition rate) |
| Interface | RS232 + USB 2.0 (transmission distance up to 100 m) |
| Software Compatibility | Windows XP / 7 / 10 |
| Language Support | English & Chinese UI |
| Reporting | Direct Print, PDF Export, CSV Export |