Particle/Powder Analysis Instruments
Filter
Showing 61–90 of 969 results
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Region Category | Domestic (China) |
| Model | Aode-308B |
| Instrument Type | Powder Flowability Tester |
| Measurable Parameters | Angle of Repose, Angle of Rest, Flow Time, Flow Velocity |
| Maximum Sample Vessel Capacity | 500 mL |
| Minimum Sample Volume | 10 mL |
| Power Supply | 220 V, 50 Hz, 60 W |
| Dimensions | 38 × 43 × 88 cm |
| Weight | 30 kg |
| Hopper Volume | 520 mL |
| Maximum Weighing Capacity | 350 g |
| Maximum Angle of Repose Measurement | 55° |
| Interchangeable Orifice Diameters (Optional) | 2, 5, 10, 15, 18, 20 mm |
| Display | 7-inch Touchscreen Interface |
| Data Output | Printed Reports & Internal Storage with Historical Query Functionality |
| Security | Dual-User Authentication (Administrator & Operator Levels) |
| Construction | Stainless Steel Hopper with Polished Interior Surface |
| Safety | Transparent Acrylic Guard Enclosure |
| Auxiliary Agitation | Motorized Stirring Rake |
| Actuation | Photoelectric + Load Cell–Based Auto-Triggered Gate Control |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AODE-309 (20219) |
| Instrument Category | Powder Flowability Tester |
| Measurable Parameters | Angle of Repose (Static & Dynamic), Angle of Rest, Flow Time, Flow Rate |
| Maximum Sample Vessel Capacity | 500 mL |
| Minimum Sample Volume | 10 mL |
| Power Supply | 5 V DC |
| Dimensions (W×D×H) | 280 × 280 × 600 mm |
| Weight | 8 kg |
| Funnel Volume | 520 mL |
| Adjustable Orifice Diameters | 4, 6, 8, 10, 13, 15, 18, 20 mm |
| Construction Materials | 304 Stainless Steel Body + Aluminum Alloy Components |
| Compliance | GB/T 21060–2007, ISO 4324 |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | Aode-310 |
| Instrument Type | Powder Flowability Tester |
| Measurable Parameters | Flow Time, Discharged Mass, Angle of Repose (θ), Bulk Density, Pile Mass, Loose Bulk Density |
| Maximum Sample Vessel Capacity | 520 mL |
| Minimum Sample Requirement | 10 g |
| Funnel Orifice Diameters | 2, 5, 8, 10, 15, 20, 25 mm |
| Power Supply | 5 V DC |
| Dimensions (W×D×H) | 280 × 280 × 600 mm |
| Weight | 8 kg |
| Construction Materials | 304 Stainless Steel (funnel, base plate, measuring arm), Aluminum Alloy (elevation platform, housing) |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | AODE-311 |
| Price Range | USD 700 – 1,400 (FOB) |
| Instrument Type | Powder Flowability Tester |
| Measurable Parameters | Apparent Density, Bulk Density |
| Maximum Sample Cup Capacity | 500 mL |
| Minimum Sample Requirement | 10 mL |
| Funnel Orifice Diameter | 12.7 mm |
| Funnel Cone Angle | 60° ± 0.5° |
| Cylinder Volume | 100 mL |
| Cylinder Inner Diameter | Φ39 mm |
| Material | ASTM A240 Grade 304 Stainless Steel (All Wetted Parts) |
| Required External Balance | ≤1 kg capacity, readability 0.02 g |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Aode-312 |
| Instrument Type | Powder Flowability Tester / Angle of Repose Tester |
| Measurable Parameters | Angle of Repose, Flow Time, Discharge Mass, Bulk Density |
| Maximum Sample Cup Capacity | 520 mL |
| Minimum Sample Volume | 10 mL |
| Cone Angle (Calibration Standard) | 30° |
| Funnel Outlet Inner Diameters | 5–10 mm (in 1 mm increments) |
| Funnel Neck Length | 40 mm |
| Funnel Included Angle | 60° |
| Circular Base Plate Diameter | 100 mm / 80 mm (with raised central base) |
| Measurement Range | 0–90° |
| Particle Size Range | 1–5000 µm |
| Funnel Material | AISI 304 Stainless Steel |
| Power Supply | 220 V AC (PC), 3 V DC (instrument unit) |
| Dimensions | 27 × 55 cm |
| Weight | 8–10 kg |
| Sieve Mesh Aperture | 1 mm |
| Compliance | Chinese Pharmacopoeia 2025 Edition, Vol. IV, General Chapter 9604 – Guidance on Powder Flowability |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Aode-312-A |
| Instrument Category | Pharmacopoeial Angle-of-Repose Tester per ChP 9604 & USP <1174> |
| Measurable Parameter | Angle of Repose |
| Maximum Sample Cup Capacity | 150 mL |
| Minimum Sample Volume | 10 mL |
| Power Supply (Host) | 3 V DC |
| Power Supply (PC Interface) | 220 V AC |
| Funnel Material | AISI 304 Stainless Steel |
| Funnel Volume | 520 mL |
| Disk Diameter | 100 mm / 80 mm (with raised base) |
| Standard Calibration Cone | 30° |
| Measurement Range | 0–90° |
| Funnel Orifice ID Options | 5, 6, 7, 8, 9, 10 mm |
| Funnel Neck Length | 40 mm |
| Funnel Included Angle | 60° |
| Sieve Mesh Aperture | 1 mm |
| Particle Size Range | 1–5000 µm |
| Test Functions | Angle of Repose, Flow Time, Flow Mass, Bulk Density, Qualitative Flowability Assessment |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Aode-315 |
| Instrument Type | European Pharmacopoeia Powder Flowability Tester |
| Measurable Parameter | Flowability |
| Maximum Sample Cup Capacity | 520 mL |
| Minimum Sample Volume | 10 mL |
| Funnel Internal Orifice Diameter | 12 mm |
| Funnel Angle | 60° |
| Funnel Stem Length | 125 mm |
| Funnel Outlet Angle | 45° |
| Funnel Wall Thickness | 1.5 mm |
| Funnel Material | ASTM A240 Type 304 Stainless Steel |
| Compliance Standard | Ph. Eur. 2.9.16 |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | Aode-75 Ultrasonic Sieve Shaker |
| Price Range | USD 7,000 – 14,000 |
| Power Supply | 220 V, 50 Hz |
| Weight | 18 kg |
| Dimensions (W×D×H) | 30 × 54 × 26 cm |
| Door Opening Height | 80 cm |
| Vibration Frequency | 3600 cycles/min (60 Hz fundamental air column resonance) |
| Adjustable Ultrasonic Frequency Range | 2–300 Hz |
| Sieving Time Range | 1.00–99.99 min |
| Max. Number of Sieves | 6 stacked |
| Max. Sample Mass | 10 g |
| Min. Sample Mass | 0.1 g |
| Particle Size Range | 5 µm – 4.75 mm |
| Vertical Tapping Mode | Programmable intermittent impact |
| Standard Sieve Compliance | GB/T 13220 (China), ASTM E323, ASTM E161 |
| Certifications | National Metrology Verification Certificate for each sieve set |
| Software Option | Optional PC-based sieving analysis software with automatic mass logging, particle size distribution calculation, and cumulative/differential curve generation |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | Aode-75 |
| Price Range | USD 7,000 – 14,000 |
| Sieving Capacity | 10 g |
| Dimensions (W×H×D) | 30 × 54 × 26 cm |
| Door Height | 80 cm |
| Weight | 18 kg |
| Power Supply | 220 V, 50 Hz |
| Frequency Range | 2–300 Hz |
| Sieving Time Range | 1–99.99 min |
| Stacking Capacity | Up to 6 × 75-mm-diameter standard sieves |
| Sieve Specifications | Internal Diameter 75 mm, External Diameter 90 mm, Height 25 mm |
| Particle Size Range | 5 µm – 4.5 mm |
| Axial Tapping Direction | Vertical |
| Operating Environment | 0–40 °C, RH < 85 % |
| Compliance | GB/T 13220, ASTM E323, ASTM D161 |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Aode100 |
| Price Range | USD 7,000 – 14,000 |
| Sample Capacity | 5–5000 mL |
| Particle Max Diameter | 15 mm |
| Dividing Speed | 80–120 rpm (adjustable) |
| Bottle Options | 30 / 100 / 250 / 500 mL |
| Dividing Ports | Standard 8-port (6- or 10-port available on request) |
| Power Supply | 220 V, 50 Hz, 60 W |
| Dimensions | 50 × 40 × 69 cm |
| Weight | 35 kg |
| Construction Material | Anodized 6061 Aluminum Alloy |
| Sample Compatibility | Dry powders, granules, and non-viscous suspensions |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Aode100211227 |
| Sample Bottle Volumes | 30 / 100 / 250 / 500 mL |
| Dividing Speed | 80–120 rpm (adjustable) |
| Sample Throughput | 5–5000 mL |
| Maximum Particle Diameter | 15 mm |
| Sample Volume per Port | 1–500 mL |
| Power Supply | 220 V, 50 Hz, 60 W |
| Dimensions | 50 × 40 × 69 cm |
| Weight | 35 kg |
| Material | 6061 Aluminum Alloy (rotor assembly) |
| Sample Types | Dry powders, granules, and stable emulsions |
| Dividing Configurations | Standard 8-port |
| Compliance | Designed for GLP-compliant sample preparation workflows |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | Aode200-20108 |
| Price | USD 5,300 (approx.) |
| Brand | Aode |
|---|---|
| Model | Aode200B |
| Drive Type | Electromagnetic 3D Vibration |
| Sample Compatibility | Dry powders, granules, and fine/coarse aggregates |
| Software Integration | Embedded sieve analysis software with automatic mass upload, real-time distribution calculation, and ASTM/USP-compliant reporting |
| Compliance | Meets ISO 2591-1, ASTM E11, USP <786>, and Chinese Pharmacopoeia IV sieve requirements |
| Data Output | Automatic particle size distribution (%) per sieve mesh, cumulative/differential curves, PDF/CSV export, unlimited report storage |
| Power Supply | 220 VAC, 50 Hz |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Aode309 (211224) |
| Instrument Category | Powder Flowability Tester |
| Measurable Parameters | Flow Time, Discharged Mass, Angle of Repose (θ), Bulk Density, Heap Mass, Loose Bulk Density |
| Maximum Sample Vessel Capacity | 520 mL |
| Minimum Sample Requirement | 10 g |
| Power Supply | 5 V DC |
| Dimensions | 280 × 280 × 600 mm |
| Weight | 8 kg |
| Funnel Outlet Diameters | 4, 6, 8, 10, 13, 15, 18, 20 mm |
| Construction Materials | 304 Stainless Steel & Aluminum Alloy |
| Compliance | GB/T 21060–2007, ISO 4324 |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | Aode309 |
| Instrument Type | Flowability Tester |
| Measurable Parameters | Angle of Repose (Static), Angle of Rest, Flow Time |
| Maximum Sample Vessel Capacity | 500 mL |
| Minimum Sample Volume | 5 mL |
| Power Supply | 5 V DC |
| Dimensions (W×D×H) | 280 × 280 × 600 mm |
| Weight | 8 kg |
| Funnel Volume | 520 mL |
| Adjustable Orifice Diameters | 4, 6, 8, 10, 13, 15, 18, 20 mm |
| Construction Materials | 304 Stainless Steel & Aluminum Alloy |
| Compliance | GB/T 21060–2007, ISO 4324 |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Aode310 |
| Instrument Category | Flowability Tester |
| Measurable Powder Parameters | Flowability Index, Flow Time |
| Maximum Sample Cup Capacity | 500 mL |
| Minimum Sample Requirement | 5 mL |
| Brand | Aode |
|---|---|
| Model | Aode75 Type 20114 |
| Origin | Liaoning, China |
| Manufacturer | Direct Producer |
| Category | Domestic Laboratory Instrument |
| Price | USD 8,100 (FOB) |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Yes |
| Model | Aode75 |
| Power Supply | 220 V, 50 Hz |
| Dimensions (W×D×H) | 30 × 54 × 26 cm |
| Door Opening Height | 80 cm |
| Weight | 18 kg |
| Vibration Frequency | 3600 cycles/min (60 Hz base air column resonance) |
| Adjustable Frequency Range | 2–300 Hz |
| Sieving Time Range | 1.00–99.99 min |
| Max. Sieving Capacity | 10 g |
| Min. Sieving Capacity | 0.1 g |
| Particle Size Range | 5 µm – 4.75 mm |
| Max. Stackable Sieves | 6 |
| Vertical Tapping | Integrated intermittent impact mechanism |
| Standard Compliance | GB/T 13220 (China), ASTM E323, ASTM D161 |
| Sieve Certification | NMI-traceable aperture verification with individual calibration certificate per sieve set |
| Noise Level | <65 dB(A) |
| Control System | Microprocessor-based digital timer and frequency controller |
| Optional Software | Automated mass-based fraction quantification, cumulative/differential particle size distribution calculation, real-time curve plotting (D10/D50/D90), CSV export, audit trail support |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Category | Domestic |
| Model | DV-200R |
| Price | USD 3,100 (FOB) |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Aode-502 |
| Instrument Type | Powder Flowability Tester |
| Measurable Parameter | Bulk Density |
| Maximum Sample Cup Capacity | 25 mL |
| Minimum Sample Requirement | 10 mL |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Aode-502-1 |
| Instrument Type | Flowability Tester |
| Measurable Parameters | Apparent Density, Bulk Density |
| Maximum Sample Cup Capacity | 500 mL |
| Minimum Sample Requirement | 10 mL |
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | WLP-216G |
| Product Type | Intelligent Fisher Sub-Sieve Analyzer |
| Porosity Range | 0.25–0.95 |
| Repeatability | ±3% |
| Measurement Range | 0.2–100 µm |
| Display Interface | PC-based Software Visualization |
| Inlet Gas Pressure | 5 kPa |
| Power Supply | 220 V / 50–60 Hz, 60 W |
| Host Weight | 17 kg |
| Dimensions (W×D×H) | 57 × 59 × 25 cm |
| Operating Environment | 15–35 °C, ≤80% RH, vibration-free, non-corrosive atmosphere |
| Compliance | ASTM B330, ISO 9277 (gas adsorption correlation), USP <429>, GLP-ready audit trail and user management |
| Origin | USA |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | APS-100 |
| Price Range | USD 0–15,000 |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 100 µm |
| Reproducibility | <1% RSD |
| Measurement Time | ≤10 minutes |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | ASA |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1–1200 µm |
| Repeatability | <1% |
| Measurement Duration | Unlimited |
| Analog Bandwidth | 10–160 MHz (standard), upgradable to 10–200 MHz |
| Max Sampling Rate | 320 MHz (standard), upgradable to 400 MHz |
| Signal Processing Architecture | Quadrature-based Fourier Transform (FT) with Phase Pulse Detection (PPD) and Adaptive Sampling |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | PDI-TK |
| Type | Laboratory Laser Diffraction Particle Analyzer |
| Dispersion Method | Dry & Wet |
| Measurement Range | 1–1200 µm |
| Repeatability | <1% |
| Measurement Duration | Unlimited |
| Laser Source | Diode-Pumped Solid-State (DPSSL) Laser |
| Wavelength | 532 nm |
| Optical Probe Weight | 2.63 kg (TK1), 2.86 kg (TK2) |
| IP Rating | IP66 |
| Calibration | NIST-Traceable, Single-Calibration-for-Life |
| Signal Processor | ASA2 Advanced Signal Analyzer |
| Software Platform | AIMS (Advanced Imaging & Measurement Suite) |
| Optional Accessories | Anti-Fog Window Shroud, Integrated Thermostatic Heating Module for Sub-Zero/Freezing Environments |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | AD200 |
| Wavelength Range | 400–1100 nm |
| Peak Detection Efficiency | 70% @ 650 nm, 55% @ 800 nm |
| Dark Count Rate | 25 cps @ −20 °C (typ.) |
| Dead Time | 40 ns |
| Output Pulse Width | 20 ns |
| Active Area | 500 µm diameter |
| Breakdown Voltage | 125 V @ 25 °C |
| Operating Voltage | +12 V |
| Temperature Control | Digital PID with Active Quenching |
| Interface | SMB (output & time-gating), USB Type-B (data & control) |
| Dimensions (W×H×D) | 120 × 92 × 30 mm |
| Weight | 350 g |
| Storage Temperature | −20 to +85 °C |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HIAC 9703+ |
| Instrument Type | Optical Liquid Particle Counter |
| Sample Volume Range | 1 mL to 1000 mL |
| Particle Size Detection Range | 0.5 µm to 600 µm |
| Regulatory Compliance | FDA 21 CFR Part 11, ISO 21501-4 |
| Preconfigured Pharmacopoeial Methods | USP <788>, USP <789>, EP 2.9.19, JP 6.07, KP 5.2.10 |
| Software | PharmSpec v5.x with Audit Trail, Electronic Signatures, and Automated Backup/Restore |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | LS 13 320 XR |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 10 nm – 3500 µm |
| Repeatability | < ±0.5% |
| Measurement Time | 10 seconds |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Model | LS Series |
| Measurement Range | 17 nm – 2000 µm |
| Accuracy | < 1% |
| Repeatability | < 1% |
| Resolution | Capable of resolving two peaks with a peak diameter ratio > 2.5 |
| Detection Channels | 116 |
| Detector Array | 132 photodiode detectors |
| Light Source | Solid-state laser (rated lifetime > 70,000 hours) |
| Optical Design | Dual-lens patented configuration with multi-wavelength and polarized light capability |
| Sample Introduction | Dry dispersion and wet suspension modes supported |
| Compliance | Designed to support ISO 13320, ASTM E2412, and USP <429> requirements for particle size distribution analysis |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MET ONE 3400+ |
| Instrument Type | Optical Particle Counter |
| Flow Rates | 28.3 L/min, 50 L/min, 100 L/min |
| Standard Sizing Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (model-dependent) |
| Laser Source | Long-life laser diode (MTBF ≥ 10 years) |
| Power | AC input 80–264 VAC |
| Dimensions | 26.7 × 26 × 21 cm (10.5" × 10.25" × 8.25") |
| Weight | 5.6 kg (no battery), 6.9 kg (with 2 cells) |
| Enclosure | 316 stainless steel |
| Operating Environment | 0–40°C, 10–90% RH (non-condensing) |
| Compliance | FDA 21 CFR Part 11 ready, ISO 21501-4, ISO 14644-1, EU GMP Annex 1 compatible |