PCR/Sequencing/Nucleic Acid Analysis
Filter
Showing 61–90 of 178 results
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Pangaea Super8 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 8 samples |
| Heating Rate | 12 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-Well Temperature Uniformity | ±0.15 °C |
| Detection Channels | 4 (FAM/VIC/ROX/Cy5) |
| Reaction Volume | 10–50 µL |
| Optical System | Waveguide-CMOS Integrated Optical Detection |
| Dimensions | 280 × 200 × 230 mm (L×W×H) |
| Sample Loading | Motorized Auto-Loading Tray |
| Operating System | Windows 10 (optimized for Microsoft Surface Go) |
| Multi-Unit Networking | ≥4 units via Ethernet (Wi-Fi adapter optional) |
| Brand | Applied Biosystems |
|---|---|
| Model | 2720 |
| Sample Capacity | 96-well |
| Heating Rate | 2.7 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.5 °C |
| Operating Temperature Range | 4.0–99.9 °C |
| Heat Lid Temperature | 105 °C |
| Memory Capacity | 100 protocols |
| Tm Calculation | Built-in |
| Power Failure Recovery | Auto-resume |
| NIST-Traceable Calibration | Yes |
| Diagnostic Self-Test | Integrated |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | 2720 |
| Sample Block | Aluminum 0.2 mL 96-well |
| Temperature Range | 4–99 °C |
| Temperature Accuracy | ±0.5 °C (35–100 °C) |
| Dimensions (L×W×H) | 36 × 21 × 22 cm |
| Part Number | 4359659 |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 3500/XL |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Category | Imported |
| Distributor Type | Authorized Third-Party Reseller |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 7300 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Maximum Heating Rate | 12°C/s |
| Temperature Accuracy | ±0.1°C (at 55°C) |
| Well-to-Well Temperature Uniformity | <0.3°C (at 55°C) |
| Reaction Volume | 25–100 µL |
| Detection Channels | 4-color fluorescence detection |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 7500 |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well and 48-well formats |
| Maximum Heating Rate | 12°C/s |
| Temperature Accuracy | ±0.1°C (at 55°C) |
| Well-to-Well Temperature Uniformity | <0.3°C (at 55°C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3100 |
| Instrument Type | First-Generation Capillary Electrophoresis Sequencer |
| Sample Throughput | Up to 768 samples per unattended run (2 × 384-well plates or 4 × 96-well plates) |
| Capillary Array | 16-capillary array |
| Excitation Source | Single 488 nm argon-ion laser |
| Detection | Dual-side illumination with grating-based full-spectrum fluorescence detection using CCD camera |
| Voltage Range | Up to 20 kV |
| Operating Temperature | 18–65 °C |
| Dimensions (W×D×H, door closed) | 74 × 54.8 × 81 cm |
| Weight | 130 kg |
| Power Requirement | 200–240 V AC, 50/60 Hz, ≤15 A, 2000 W |
| Environmental Conditions | 15–35 °C ambient, 20–80% non-condensing humidity |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730 |
| Instrument Type | First-Generation Sanger Sequencer |
| Configuration | Refurbished Unit with Full System Validation |
| Compliance | Designed to meet legacy GLP/GMP-relevant operational standards for nucleic acid analysis |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730XL |
| Category | Imported Instrument |
| Condition | Refurbished Unit |
| Sample Throughput | 96-capillary array |
| Read Length | Up to 1,000 bases (typical under standard POP-7 polymer and BigDye Terminator v3.1 chemistry) |
| Data Output Format | AB1 (.ab1), SCF, FASTA, QUAL |
| Base Calling Accuracy | ≥99.99% (Q40+ for >80% of bases in high-quality templates) |
| Run Time | ~2.5 hours per 96-well plate (standard sequencing protocol) |
| Detection System | CCD-based fluorescence detection with four-color laser excitation (488 nm, 532 nm, 595 nm, 635 nm) |
| Capillary Array | 96 × 50 cm fused-silica capillaries with polymer matrix (POP-7 or POP-6) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ATC |
| Sample Capacity | 96-well and 384-well plates |
| Ramp Rate | 3.5°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Uniformity | ≤0.5°C (20 seconds after reaching 95°C) |
| Compliance | SiLA Rapid Integration™ certified |
| Software Interface | RESTful APIs, preconfigured for Beckman Coulter, Hamilton, and other major automation platforms |
| Brand | Applied Biosystems |
|---|---|
| Model | GeneAmp® 9700 |
| Origin | USA |
| Temperature Accuracy | ±0.25°C (35–100°C) |
| Temperature Range | 4–99°C |
| Ramp Rate | 3.5°C/sec (55–95°C) |
| Block Uniformity | ±0.5°C (35–100°C, 30 sec hold) |
| Heat Lid Temperature | 105°C |
| Display Resolution | 0.1°C (computed sample temperature) |
| Dimensions | 40.6 × 30 × 26 cm |
| Weight | 12.7 kg |
| Sample Formats | Interchangeable blocks — 60-well (0.5 mL), 96-well (0.2 mL), dual 96-well, dual 384-well |
| Software | GeneAmp 9700 Network Software (multi-instrument control) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | MiniAmp |
| Instrument Type | Standard PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.0 °C/sec |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | <0.5 °C (measured 30 sec after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MiniAmp Plus |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | 3.5 °C/s |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (30 seconds after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex 2×Flat PCR System |
| Instrument Type | Standard Thermal Cycler |
| Sample Throughput | 2 × 96-well flat plates (0.2 mL) |
| Heating Rate | 1.6°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Inter-well Temperature Uniformity | <0.5°C (20 sec after reaching 95°C) |
| Module Configuration | Dual independent flat-block thermal modules |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | ProFlex |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 32-well, 96-well, dual 96-well, dual 384-well, and 24 × 20k Digital PCR Chip modules |
| Ramp Rate | Up to 6.0 °C/s (user-adjustable) |
| Temperature Accuracy | ±0.25 °C (35–99.9 °C) |
| Well-to-Well Uniformity | < 0.5 °C (measured 20 s after reaching 95 °C) |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 4°C/sec |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.5°C (measured 30 sec after reaching 95°C) |
| Thermal Control Architecture | VeriFlex™ 3-Zone Independent Peltier Module |
| Interface | Capacitive Touchscreen, USB 2.0, Wi-Fi 802.11 b/g/n |
| Software Compatibility | Thermo Fisher Connect Cloud Platform, compatible with standard .pcr file import/export |
| Brand | Applied Biosystems |
|---|---|
| Origin | Singapore |
| Model | VeritiPro |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 96-well (0.2 mL) and 384-well (0.02 mL) blocks |
| Heating Rate | 6.0°C/s |
| Temperature Accuracy | ±0.25°C (35–99.9°C) |
| Well-to-Well Temperature Uniformity | <0.25°C (at 95°C, measured 30 s after target reached) |
| VeriFlex™ Block | 6 independently controlled thermal zones |
| Thermal Lid | 30–110°C, pressure-adjustable, auto-lift |
| Operating Voltage | 100–240 V, 50–60 Hz |
| Power Consumption | ≤700 W |
| Dimensions (H×W×D) | 21.7 × 24.5 × 46.5 cm |
| Weight | 12.0 kg |
| Environmental Requirements | 15–30°C, 15–80% RH (non-condensing) |
| Brand | Autobio |
|---|---|
| Model | Sikun1000 |
| Instrument Type | Second-Generation Sequencing Platform |
| Regulatory Status | CE-IVD & NMPA-Certified In Vitro Diagnostic Device |
| Form Factor | Benchtop Sequencer |
| Read Length | 50–300 bp |
| Throughput | 110M–330M Reads per Run |
| Data Output | 5–100 Gb per Run |
| Run Time | 3.5–24 h |
| Base Call Accuracy (Q30) | >85%–90% |
| Optical Detection Method | Fluorescence-Based Sequencing-by-Synthesis on Solid-Phase Amplified Flow Cell |
| Compliance | ISO 13485, IEC 62304, FDA 21 CFR Part 820, GLP/GMP-Aligned Data Integrity Framework |
| Brand | Autobio |
|---|---|
| Model | Sikun2000 |
| Instrument Type | Second-Generation Sequencing Platform |
| Regulatory Status | CE-IVDR and NMPA-Certified In Vitro Diagnostic Device |
| Form Factor | Benchtop Sequencer |
| Read Length Range | 50–300 bp |
| Data Quality | Q30 ≥ 85%–90% |
| Accuracy | >99.9% Base Call Accuracy (per-cycle consensus) |
| Run Time | As fast as 3.2 hours (dependent on read length and chip configuration) |
| Throughput | Mid-Throughput Chip: 220 million reads (11–66 Gb) |
| High-Throughput Chip | 660 million reads (33–200 Gb) |
| Chemistry | Surface-Based Bridge Amplification with Reversible Dye-Terminator Fluorescence Detection |
| Compliance | Designed and validated per ISO 13485, IEC 62304, and aligned with FDA 21 CFR Part 820 and EU IVDR Annex I essential requirements |
| Brand | Autobio |
|---|---|
| Model | Sikun500 |
| Instrument Type | Second-Generation Sequencing Platform |
| Medical Device Classification | Class III (China NMPA) |
| Form Factor | Benchtop Sequencer |
| Read Length | 50–300 bp |
| Q30 Score | >85–90% |
| Sequencing Accuracy | >99.9% |
| Run Time | 3.5–24 hours |
| Throughput | 60M–170M Reads per Run |
| Data Output | 5–50 Gb per Run |
| Origin | Henan, China |
| Regulatory Status | CE-IVD compliant (pending), NMPA registered |
| Brand | Autobio |
|---|---|
| Model | AutoMolec 3000 |
| Origin | Henan, China |
| Sample Throughput | 3000 tests/day |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.5 °C |
| Detection Limit | <100 copies/mL |
| Cycle Time per Sample | ~100 min |
| Compliance | ISO 13485, CE-IVD, NMPA Registration No. 20223400123 |
| Brand | Azure Biosystems |
|---|---|
| Origin | USA |
| Model | Cielo 6 / Cielo 3 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Max Heating Rate | 6°C/s |
| Temperature Accuracy | ±0.1°C |
| Well-to-Well Temperature Uniformity | ±0.2°C |
| Excitation Source | High-Power LED (450–730 nm for Cielo 6 |
| Detection Channels | 6 (Cielo 6) / 3 (Cielo 3) |
| Multiplexing Capacity | Up to 6 targets (Cielo 6) / up to 3 targets (Cielo 3) |
| Reaction Volume | 1–150 µL (10–65 µL recommended) |
| Dynamic Range | 10 logs |
| Onboard Memory | 32 GB (~20,000 experiments) |
| Connectivity | USB, Wi-Fi, Ethernet |
| Footprint | 30.5 × 50.8 × 43.2 cm (W × D × H) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ 384-Well |
| Instrument Type | Gradient Thermal Cycler |
| Sample Capacity | 384-well plate |
| Max Heating Rate | 2.5 °C/s |
| Temperature Accuracy | ±0.2 °C at 90 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 s at 90 °C |
| Temperature Gradient Range | 1–24 °C across 12 columns |
| Gradient Accuracy | ±0.2 °C (last column) |
| Operating Temperature Range | 0–100 °C |
| Input Power | 850 W max |
| Display | 8.5-inch color LCD touchscreen |
| Onboard Memory | >1,000 protocols |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ 96 Deep Well |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 1–96 wells (0.2 mL tubes or 96-well plates) |
| Max Heating Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Heating/Cooling Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 sec at 90°C |
| Temperature Gradient Range | 30–100°C |
| Gradient Accuracy (last column) | ±0.2°C |
| Column-wise Uniformity | ±0.4°C within 10 sec at 90°C |
| Input Power | 850 W max |
| Display | 8.5" color LCD touchscreen |
| Onboard Memory | >1,000 protocols |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ Dual 48 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 2 × 48 × 0.2 mL tubes or 2 × 48-well plates |
| Max Heating Rate | 4°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Temperature Gradient Range | 1–24°C (30–100°C) |
| Gradient Accuracy | ±0.2°C (last column) |
| Gradient Uniformity per Column | ±0.4°C within 10 s |
| Input Power | 850 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX Connect |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well (0.2 mL tubes) |
| Maximum Heating Rate | 5 °C/s (adjustable from 0.1 to 5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Sources | 3 LEDs (450–535 nm) |
| Emission Detection Range | 3 Photodiodes (515–580 nm) |
| Gradient PCR | Yes, range 30–100 °C, max ΔT = 24 °C |
| High-Resolution Melting (HRM) Support | Yes |
| Connectivity | USB |
| Dimensions (W×D×H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Duet |
| Detection Channels | 2 + FRET |
| Temperature Uniformity | ±0.3°C across 96-well block |
| Gradient Range | Up to 24°C |
| Software | CFX Maestro (including FDA 21 CFR Part 11-compliant Security Edition) |
| Included License | qbase+ Advanced Analysis Module |
| Optical System | Solid-State Scanning Optical Shuttle |
| Calibration | Factory-calibrated for common dyes (FAM, HEX, VIC, ROX, Cy5, etc.) |
| Compatibility | Full compatibility with Bio-Rad PrimePCR Assays and SsoAdvanced Supermixes |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus 384 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 384-well format |
| Heating Rate | 2.5 °C/sec |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.3 °C |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus 96 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.3°C |
| Optical Configuration | Individual well excitation and detection with FRET-capable channels |