| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus 96 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.3°C |
| Optical Configuration | Individual well excitation and detection with FRET-capable channels |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus Deepwell |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 2.5°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX384 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 384-well format |
| Maximum Heating Rate | 2.5 °C/s (adjustable from 0.1 to 2.5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Range | 5 LEDs (400–650 nm) |
| Emission Detection Range | 5 Photodiodes (515–690 nm) |
| Supported Applications | Absolute Quantification, Gene Expression Analysis, SNP Genotyping, HRM (High-Resolution Melting), Multiplex Detection (up to 4 targets per well) |
| Software | CFX Maestro Secure Edition (21 CFR Part 11 compliant, audit trail, user access control) |
| Thermal Block | Integrated C1000 Touch thermal cycler engine |
| Gradient PCR | Yes, 30–100 °C range, max ΔT = 24 °C |
| Dimensions (W × D × H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg (47 lb) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX96 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well (0.2 mL tubes) |
| Max Heating Rate | 5 °C/s (adjustable from 0.1 to 5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Range | 6 LEDs (450–684 nm) |
| Emission Detection Range | 6 Photodiodes (515–730 nm) |
| Gradient PCR | Yes, 30–100 °C, max ΔT = 24 °C |
| High-Resolution Melting (HRM) Support | Yes |
| Interface | USB |
| Dimensions (W×D×H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFX96 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well |
| Heating Rate | 3.3°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTC Tempo |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 48/48 dual-block |
| Heating Rate | 5°C/s |
| Temperature Accuracy | ±0.2°C (measured at 90°C) |
| Well-to-Well Temperature Uniformity | ±0.4°C (measured at 90°C) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | QX Continuum™ |
| Instrument Type | Digital PCR System |
| Sample Throughput | 96-well format |
| Certified Performance | NMI-traceable reference material validation |
| Droplet Generation | >20,000 droplets per 16 µL sample |
| Multiplexing Capacity | Up to 4 targets per well |
| Thermal Zones | Up to 8 independent temperature zones per plate |
| Software | QX Insight Analysis Software |
| Regulatory Status | For Research Use Only (RUO), not for clinical diagnostic use |
| Compliance | Designed to support GLP/GMP-aligned data integrity practices |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QX ONE |
| Instrument Type | Digital PCR System |
| Sample Throughput | 32–480 wells per run |
| Heating Rate | 2.5 °C/s |
| Temperature Accuracy | ±0.2 °C (at 90 °C) |
| Well-to-Well Temperature Uniformity | ±0.4 °C (at 90 °C) |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | QX200 |
| Instrument Type | Digital PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 0.1–5.0°C/s (typical setting: 2.0°C/s) |
| Temperature Accuracy | ±0.2°C (at 90°C) |
| Well-to-Well Temperature Uniformity | ±0.4°C (at 90°C) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Instrument Type | Digital PCR System |
| Model | QX600 |
| Detection Channels | 6-color (FAM, HEX, Cy5, Cy5.5, ROX, ATTO 590) |
| Multiplex Capacity | up to 12-plex per well (CNV applications) |
| Limit of Detection | <0.1% mutant allele frequency |
| Quantification Precision | ±10% CV |
| Regulatory Compliance | FDA 21 CFR Part 11 (Advanced Software), GLP/GMP-ready audit trail |
| Platform Compatibility | Fully compatible with Manual DG and AutoDG droplet generators |
| Assay Support | TaqMan probe-based and EvaGreen dye-based ddPCR assays |
| Certification | Traceable calibration verified by Australia’s National Measurement Institute (NMI) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QX700™ E |
| Instrument Type | Digital PCR System |
| Sample Throughput | 48-well |
| Detection Channels | 7-color multiplexing |
| Sample Input Volume | 5 µL per reaction |
| Droplets per Sample | ≥17,000 |
| Automation Level | Fully integrated, walk-away operation |
| Run Time for 48 Samples | 2.5 hours |
| Chip Format | Single disposable cartridge accommodating up to 48 samples |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | QX700™ HT |
| Instrument Type | Digital PCR System |
| Sample Throughput | 384-well format |
| Detection Channels | 7-color multiplexing |
| Sample Input Volume | 5 µL |
| Effective Droplets per Sample | ≥17,000 |
| Automation Level | Fully integrated workflow (droplet generation, thermal cycling, and fluorescence reading) |
| Max. Chip Capacity per Run | 2 microfluidic chips |
| Time to Result | ≤2.5 hours for 96 samples |
| Time to Result | ≤8 hours for 384 samples |
| On-demand Loading | Yes, with independent thermal control per 16-well chip segment |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QX700™ S |
| Instrument Type | Digital PCR System |
| Sample Throughput | 192-well format |
| Detection Channels | 7-color simultaneous detection |
| Sample Input Volume | 5 µL |
| Effective Droplet Partitions per Sample | ≥17,000 |
| Automation Level | Fully automated end-to-end workflow |
| Chip Format | 16-well disposable cartridge (scalable to 192 samples per run) |
| Run Time for 192 Samples | 8 hours |
| Run Time for 96 Samples | 5 hours |
| Thermal Cycling | Independent programmable thermal cycling per well |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 384 Well |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 384-well plate |
| Max Heating Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Inter-well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Gradient Range | 1–24°C across 12 columns |
| Gradient Accuracy (last column) | ±0.2°C |
| Operating Temperature Range | 0–100°C |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 96 Deep Well |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Ramp Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Uniformity | ±0.4°C within 10 s at 90°C |
| Gradient Range | 30–100°C, Span 1–24°C |
| Gradient Accuracy (Last Column) | ±0.2°C |
| Gradient Uniformity (Within Column) | ±0.4°C within 10 s |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| PCR Licensing | Yes |
| Onboard Memory | >1,000 protocols |
| USB Ports | 4 × Type-A, 1 × Type-B |
| Display | LCD |
| Heating Technology | Instant-On Peltier |
| Thermal Block Design | Patented honeycomb architecture |
| Programmable Interface | Text-based and semi-graphical editing |
| Heat Lid | Adjustable pressure, auto-lift compatible |
| Safety | Password-protected protocol folders |
| PC Connectivity | Windows XP or later via C1000 Touch controller (up to 3 S1000 units per C1000) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 96-Well |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Heating/Cooling Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 sec at 90°C |
| Gradient Range | 30–100°C, Span 1–24°C |
| Gradient Accuracy (Last Column) | ±0.2°C |
| Column Uniformity | ±0.4°C within 10 sec per column at target temperature |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ Dual 48 Well |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Throughput | 2 × 48 wells (0.2 mL tubes or plates) |
| Max Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.2 °C at 90 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 s at 90 °C |
| Gradient Range | 30–100 °C, Span 1–24 °C |
| Temperature Range | 0–100 °C |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | T100 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL) |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.5 °C |
| Well-to-Well Temperature Uniformity | ±0.5 °C |
| Gradient Range | 1–25 °C |
| Temperature Range | 4–100 °C |
| Gradient Temperature Range | 30–100 °C |
| Onboard Memory | 500 protocols |
| Display | 5.7" high-resolution color LCD touchscreen |
| Cooling Method | Peltier-based |
| Heating Method | Semiconductor-based |
| Warranty | 2 years |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | T100™ |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL plates or tubes) |
| Max Heating/Cooling Rate | 4 °C/s |
| Temperature Accuracy | ±0.2 °C (at 90 °C) |
| Well-to-Well Uniformity | ±0.4 °C (at 90 °C) |
| Gradient Range | 30–100 °C |
| Gradient Span | 1–25 °C |
| Operating Temperature Range | 4–100 °C |
| Onboard Memory | 500 protocols |
| Display | 5.7" high-resolution color touchscreen |
| Interface | 1 × USB port |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | BioDrop 125 |
| Detection Time | 2 s |
| Wavelength Accuracy | ±2 nm |
| BSA Detection Range | 0.1–134 mg/mL |
| DNA Detection Range | 1–12,000 ng/µL |
| Sample Type | Nucleic Acids & Proteins |
| Sample Volume Requirement | 0.6–2 µL |
| Optical Path Length | 0.125 mm |
| Beam Height | 15 mm |
| Compatibility | Universal with Standard UV-Vis Spectrophotometers |
| Cuvette Type | Fixed-pathlength, Quartz-based Microvolume Cuvette |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | BioDrop 500 / BioDrop 125 |
| Detection Time | <5 s |
| Wavelength Accuracy | ±2 nm |
| BSA Detection Range | 0.5–100 mg/mL |
| DNA Detection Range | 1.2–12,000 ng/µL |
| Sample Volume Requirement | 0.6–2.5 µL |
| Compatible With | Standard UV-Vis Spectrophotometers |
| Optical Path Lengths | 0.5 mm (BioDrop 500), 0.125 mm (BioDrop 125) |
| Path Length Tolerance | ±5 µm |
| Beam Height Options | 15 mm or 8.5 mm |
| Physical Dimensions | 12.5 mm (W) × 12.5 mm (D) × 61.0 mm (H) |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | BioDrop DUO+ |
| Sample Volume Requirement | 0.5 µL |
| Detection Time | <3 s |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Absorbance Range | –0.3 A to 2.5 A |
| dsDNA Detection Limit | 1–12,000 ng/µL |
| Protein (BSA) Detection | Supported |
| Light Source | Pulsed Xenon Lamp |
| Detector | 1024-pixel CCD Array |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.5% T (220 nm, NaCl |
| Absorbance Accuracy | ±0.005 A or ±1% of reading (whichever is greater, at 546 nm) |
| Absorbance Reproducibility | ±0.003 A (0–0.5 A), ±0.007 A (0.5–1.0 A) |
| Optical Path Accuracy (Microvolume) | ±5 µm |
| Dimensions | 410 × 280 × 190 mm |
| Weight | 3.55 kg |
| Power Input | 120–250 V, 50/60 Hz, max. 40 VA |
| Interface | 7-inch capacitive color touchscreen (English, French, German, Spanish, Chinese), USB port for flash drive and PC connectivity |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | BioDrop uLITE+ |
| Sample Volume | 0.5 µL |
| Detection Limit (dsDNA) | 1 ng/µL |
| Wavelength Accuracy | ±2 nm |
| Measurement Time | <3 s |
| Wavelength Range | 190–1100 nm |
| Absorbance Range | –0.3 A to 2.5 A |
| Photometric Accuracy | ±0.005 A or ±1% of reading (whichever is greater, at 546 nm) |
| Light Source | Pulsed Xenon Lamp |
| Detector | CMOS Array |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.5% T (at 220 nm with NaCl |
| Dimensions | 410 × 280 × 190 mm |
| Weight | 3.55 kg |
| Brand | BIOER |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | FQD-16B |
| Sample Throughput | 16 wells |
| Maximum Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.1 °C |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96C |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96 × 0.2 mL (compatible with single tubes, 8-tube strips, and 96-well plates) |
| Heating Rate | 6.5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-well Temperature Uniformity | ≤ ±0.2 °C |
| Temperature Range | 4–105 °C (0.1 °C increment) |
| Fluorophore Channels | 6-channel detection (FAM/SYBR Green I, VIC/HEX/TET/JOE/TAMRA/Cy3 NED, ROX/Texas Red, Cy5, Cy5.5) |
| Dynamic Range | 1–10¹⁰ copies/L |
| Reaction Volume | 10–100 µL |
| Thermal Control Mode | Block control & simulated tube control |
| Heat Lid Temperature | 30–110 °C (default 105 °C) |
| Power Input | 100–240 V, 50/60 Hz, 1000 VA |
| Interface | USB, Bluetooth |
| Dimensions | 490 × 290 × 391 mm |
| Net Weight | 28 kg |
| Safety Certifications | CE, RoHS 2 compliant |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96C |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well |
| Heating Rate | 6.5°C/s |
| Temperature Accuracy | ±0.1°C |
| Well-to-Well Temperature Uniformity | ±0.2°C |
| Detection Channels | 6 |
| Excitation Source | Arrayed Planar LED Light Source |
| Optical Detection | Top-reading, calibration-free, bundled high-end imported optical fiber bundle |
| Thermal Control Architecture | 6-zone independent Peltier-based temperature control |
| Input Power | AC 100–240 V, 50/60 Hz, 1000 W |
| Dimensions (L×W×H) | 490 × 290 × 391 mm |
| Net Weight | 28 kg |
| Compatible Consumables | 0.2 mL 96-well plates, 0.2 mL single tubes, 0.2 mL 8-tube strips (transparent, white, frosted) |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | FQD-A1600 |
| Instrument Type | Real-Time Quantitative PCR System with Integrated Sample-to-Answer Automation |
| Sample Throughput | 16 samples per run |
| Maximum Heating Rate | ≥10 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Inter-well Temperature Uniformity | ≤±0.3 °C |
| Dimensions (L×W×H) | 1850 × 730 × 1530 mm |
| Power Supply | AC 220 V, 50 Hz, 2800 VA |
| Sample Input Format | Compatible with standard cryovials, centrifuge tubes, and clinical collection tubes (e.g., 1.5–2.0 mL) |
| Sample Types | Whole blood, nasopharyngeal/oropharyngeal swabs, urine, animal/plant tissues for DNA/RNA extraction |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TC-96/G/H(b)B1 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | ≥5.5 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.2 °C |
| Gradient Range | Up to 30 °C across block |
| Thermal Lid Temperature & Pressure | Adjustable |
| Control Interface | USB-based multi-unit networking (up to 30 units per PC) |
| Data Storage | Internal memory + USB flash drive support |
| Safety Features | Power-loss recovery, file encryption, Ferrotec Peltier modules |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GeneExplorer |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well plate |
| Maximum Heating Rate | 6°C/sec |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.2°C |
| Gradient Function | 12-column linear gradient (1–30°C) |
| Dimensions (L×W×H) | 420 × 269 × 254 mm |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)B |
| Sample Capacity | 96 × 0.2 mL tubes |
| Temperature Range | 4–105°C (0.1°C resolution) |
| Max Heating Rate | 6°C/s |
| Max Cooling Rate | 5.5°C/s |
| Temperature Uniformity | ≤ ±0.2°C |
| Temperature Accuracy | ≤ ±0.1°C (measured 30 s after reaching 55°C, 72°C, or 95°C) |
| Heat Lid Temperature | 30–110°C |
| Gradient Range | 1–30°C |
| Time Increment/Decrement | 0–9 min 59 sec |
| Temperature Increment/Decrement | 0.1–9.9°C |
| Program Storage | Unlimited (2000 onboard + USB/LAN/WiFi expansion) |
| Connectivity | USB, LAN, Wi-Fi |
| Power Input | 100–240 VAC, 50–60 Hz, 600 W |
| Dimensions (L×W×H) | 420 × 269 × 254 mm |
| Net Weight | 10.5 kg |
| Heat Lid Actuation | Single-step mechanical lock |