PCR/Sequencing/Nucleic Acid Analysis
Filter
Showing 31–60 of 399 results
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Fast PCR Cycler |
| Sample Capacity | 96-well (0.2 mL tubes, 96-well plates, or 12×8 strip tubes) |
| Max Heating Rate | 6.0 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.2 °C |
| Gradient Span | 0.1–30.0 °C (linear, per column) |
| Gradient Range | 20–99 °C |
| Block Temp Range | 3–99 °C |
| Lid Temp Range | 30–110 °C |
| Display | 7″ capacitive color touchscreen |
| Noise Level | ≤45 dB(A) |
| Power Consumption | 850 W |
| Dimensions (W×H×D) | 277 × 264 × 457 mm |
| Weight | 15 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Fast PCR Thermal Cycler |
| Model | Biometra TAdvanced 96 SG |
| Sample Capacity | 96-well format (standard 96-well plates, 0.2 mL tubes, or 8-tube strips) |
| Max Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.15 °C |
| Gradient Span | up to 40 °C across 12 columns |
| Gradient Modes | Linear and Random |
| Block Material | Gold-plated pure silver thermal block |
| Heat Lid | High-Performance Smart Lid (HPSL), pressure-regulated, max lid temperature 110 °C |
| User Management | Three-tier Advanced User Management (AUM) with password protection |
| Software Interface | Dual-view program editor (tabular & graphical), intelligent protocol builder, preloaded templates |
| Compliance Features | Built-in self-diagnostic suite with audit-trail-capable log storage, GLP-compliant operation |
| Operating Noise | ≤45 dB(A) |
| Cooling Method | Bottom-intake / rear-exhaust airflow design |
| Touchscreen | Full-color capacitive touchscreen, glove-compatible |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biometra TAdvanced 96 SG |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.15 °C |
| Gradient Span | 40 °C (12-column linear or random gradient) |
| Heating/Cooling Rate | RAC-controlled ramping |
| Thermal Lid Temperature | Up to 110 °C |
| Noise Level | ≤45 dB(A) |
| Compliance | GLP-compliant logging, FDA 21 CFR Part 11-ready audit trail support (via software), ISO/IEC 17025-aligned operation |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | Biometra TAdvanced 96 SG |
| Instrument Type | Fast Thermal Cycler |
| Sample Capacity | 96-well format |
| Max Heating Rate | 8.0 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.15 °C |
| Gradient Span | Up to 40 °C across 12 columns |
| Cooling Rate (Max) | 5.5 °C/s |
| Heat Lid Temperature Range | Up to 110 °C |
| Noise Level | ≤45 dB(A) |
| Display | 7-inch capacitive color touchscreen |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Biometra TAdvanced 96SG |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Gradient PCR Instrument |
| Model | Biometra TAdvanced Twin 48G |
| Sample Capacity | 48 × 2 wells (dual independent blocks) |
| Heating Rate | 5.2 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-well Temperature Uniformity | ±0.2 °C |
| Gradient Range | Linear gradient across 8 rows (LGT) |
| Thermal Sensor | PT100 (Swiss-made, 25-year heritage) |
| Noise Level | ≤45 dB(A) |
| Lid Pressure Control | High-Performance Smart Lid (HPSL) with clutch-based constant-force mechanism |
| User Management | Three-tier Advanced User Management (AUM) with password protection and role-specific permissions |
| Software Features | Intelligent Protocol Assistant (IPA), built-in self-diagnostic suite (thermal ramping, lid function, gradient validation), glove-compatible capacitive touchscreen display |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | Biometra TAdvanced Twin |
| Block Configuration | Dual independent 48-well (0.2 mL) blocks or configurable dual-slot modules (e.g., 48×2 standard, 48×2 gradient, 30×2 for 0.5 mL tubes, hybrid 0.2 mL + 0.5 mL) |
| Control | Fully independent thermal control per block |
| Module Recognition | Automatic detection via embedded ID chip |
| Programming Modes | Standard, Gradient, Touchdown, Hot Start, Long PCR |
| Interface | 7-inch full-color capacitive touchscreen (glove-compatible) |
| Safety & Compliance | CE, IEC 61010-1, ISO 13485 (for IVD-relevant configurations), GLP/GMP-ready audit trail support in software |
| Cooling System | Passive base conduction + rear exhaust fan |
| Acoustic Noise Level | <35 dB(A) at 1 m |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Gradient PCR Instrument |
| Sample Capacity | 96-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.2 °C |
| Gradient Configuration | 12-column linear or randomized gradient profiles |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | Biometra TOne 96G |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Max Heating Rate | 4.0 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C at 55 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | Biometra TRIO 48 |
| Sample Throughput | 144 wells (3 × 48-well blocks) |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Block Uniformity | ±0.2 °C across block |
| Display | 7-inch full-color capacitive touchscreen |
| Power Recovery | Auto-resume after power interruption |
| Tube Compatibility | Standard 0.2 mL tubes and 8-tube strips |
| Cooling Method | Passive air cooling with bottom intake / rear exhaust airflow |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Biometra TRobot II |
| Instrument Type | Fast-cycle PCR System |
| Sample Throughput | 96-well or 384-well format |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.5 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | CyBio FeliX |
| Extraction Method | Magnetic Bead-Based |
| Automation Level | Dedicated Fully Automatic |
| Throughput | 1–96 samples per run |
| Compatible Consumables | Pre-filled and non-pre-filled SmartExtraction kits |
| Liquid Handling Precision | Based on 25+ years of CyBio high-accuracy pipetting technology |
| Contamination Control | Integrated UV sterilization, sealed front access door, 1 mL filter tips |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | InnuPure C16 |
| Purification Principle | Magnetic Bead-Based (Surface-Modified Nanoscale Beads) |
| Throughput | 1–16 Samples per Run |
| Maximum Sample Volume | 2 mL Whole Blood |
| Elution Volume Range | 50–500 µL (10 µL Increments) |
| Purification Time | As Fast as 40 Minutes |
| Heating Capability | Up to 70 °C |
| Pipetting Volume | 1000 µL Filtered Tips |
| Control Interface | 5.7-inch Color Touchscreen (HID-Pro 320) |
| Dimensions (W × H × D) | 380 × 435 × 530 mm |
| Weight | 28 kg |
| Connectivity | RS-232, USB |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | InnuPure C16 touch |
| Extraction Method | Magnetic Bead-Based (with optional Smart Extraction technology) |
| Automation Level | Dedicated Fully Automatic |
| Application Scope | DNA/RNA isolation from blood, tissue, cells, FFPE, bacteria, viruses, forensic swabs, stool, food matrices, and cell-free nucleic acids |
| Compliance | Designed for GLP/GMP-adjacent workflows |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Model | qTOWER 2.2 |
| Price | Upon Request |
| Optical Channels | 6 simultaneous detection channels |
| Excitation Sources | 3 high-intensity LEDs (blue, red, white) |
| Detection Technology | Channel-type photomultiplier tube (CPM) |
| Filter Configurations | 10 interchangeable Ex/Em filter sets |
| Sensitivity | 1 nM FAM in 30 µL reaction volume |
| Sample Capacity | 96-well format |
| Max Ramp Rates | 5.5 °C/s (heating), 4.0 °C/s (cooling) |
| Temperature Uniformity | ±0.2 °C at 95 °C |
| Temperature Accuracy | ±0.1 °C |
| Gradient Range | Up to 40 °C |
| Thermal Lid | 110 °C with SPS (Sample Protection System) and auto-adjusting pressure (up to 10 kg/plate) |
| Software | qPCRsoft v4.x for absolute/relative quantification, ΔΔCt, allelic discrimination, PCR efficiency analysis, and FRET applications |
| Interface | USB 2.0 |
| Dimensions (W×H×D) | 275 × 585 × 275 mm |
| Weight | ~25 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | qTOWER3 G IVD |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | qTOWER3 G touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Maximum Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.10 °C |
| Excitation Source | Four solid-state RGBW LEDs (blue, green, red, white) |
| Detection System | 8-channel fiber-optic scanning with channel-type photomultiplier tube (PMT) |
| Detection Channels | Configurable 1–6 channels |
| Thermal Gradient | 12-column linear gradient (spanning up to 40 °C) |
| Sample Block Material | Gold-plated pure silver block |
| Lid System | Motorized, pressure-regulated heated lid with auto-height adjustment |
| Software | qPCRsoft v5.x compliant with MIQE guidelines, supporting absolute quantification, relative quantification (ΔΔCt & dual standard curve), melting curve analysis, SNP/allelic discrimination, endpoint analysis, amplification efficiency calculation, and audit-trail-enabled reporting per FDA 21 CFR Part 11 requirements |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Maximum Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Excitation Source | 7 high-intensity solid-state LEDs (UV–NIR spectrum) |
| Detection Technology | 8-channel fiber-optic scanning with PMT detector |
| Detection Channels | Configurable 1–6 channels, including dedicated UV and protein-melting filter sets |
| Linear Temperature Gradient | 12-column gradient (spanning up to 40 °C) |
| Thermal Block Material | Gold-plated pure silver |
| Software | qPCRsoft v5.x (MIQE-compliant reporting, audit trail, CFR Part 11-ready configuration options) |
| Brand | Analytik Jena |
|---|---|
| Origin | Shanghai, China |
| Model | qTOWER3G touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well |
| Maximum Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.10 °C |
| Excitation Source | Four Solid-State RGBW LEDs (Blue, Green, Red, White) |
| Detection System | 8-Channel Fiber-Optic Scanning with Channel-Type PMT Detectors |
| Temperature Gradient | 12-Column Linear Gradient |
| Thermal Lid | Motorized Auto-Lid with Pressure & Height Adjustment |
| Compatible Consumables | Standard 96-Well Plates, 8-Tube Strips, Single Tubes |
| Optical Channels | Configurable 1–6 Channels with 12 Optional Filter Sets (including FRET and Protein Melting Analysis Configurations) |
| Software | qPCRsoft v5.x (MIQE-Compliant Reporting, Audit Trail, CFR Part 11 Ready) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | qTOWERiris |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | Smart Extraction |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | TAdvanced 96SG |
| Instrument Type | Fast Thermal Cycler |
| Sample Capacity | 96-well format |
| Max Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.15 °C |
| Display | 7-inch color capacitive touchscreen |
| Gradient Function | Linear temperature gradient across 12 columns (spanning up to 40 °C range) |
| Cooling Method | Dual-zone Peltier with bottom intake / rear exhaust airflow |
| Compatible Vessels | Standard 96-well plates, 0.2 mL tubes, and 8-tube strips |
| Brand | Analytik Jena |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format (compatible with standard 96-well plates, 0.2 mL tubes, and 8-tube strips) |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | < ±0.1 °C |
| Well-to-Well Temperature Uniformity | < ±0.2 °C |
| Gradient Range | 12-column linear temperature gradient (spanning up to 30 °C across columns) |
| Display | 7-inch full-color capacitive touchscreen |
| Cooling Method | Passive convection with bottom-intake / rear-exhaust airflow architecture |
| Construction | Anodized aluminum block with corrosion-resistant alloy coating |
| Brand | Analytik Jena |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Standard PCR Thermocycler |
| Model | TRIO |
| Sample Capacity | 3 × 48-well blocks (144 total wells) |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | < ±0.1 °C |
| Block Uniformity | < ±0.2 °C across wells |
| Display | 7-inch full-color capacitive touchscreen |
| Design | Bottom-intake / rear-exhaust airflow |
| Tube Compatibility | Standard 0.2 mL tubes and 8-tube strips |
| Compliance | Designed to support GLP/GMP workflows with audit-ready operation logs |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | TRIO |
| Instrument Type | Standard PCR Thermocycler |
| Sample Capacity | 144 (3 × 48-well blocks) |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Block Uniformity | ±0.2 °C |
| Compatible Vessels | 48-well plates, 8-tube strips, 0.2 mL and 0.5 mL single tubes |
| Display | 7-inch capacitive color touchscreen (glove-compatible, anti-glare) |
| Noise Level | <35 dB(A) |
| Cooling/Heating Architecture | Bottom-intake, rear-exhaust airflow design |
| Power Recovery | Auto-restart after power interruption |
| Software Features | User-specific quick-start, built-in self-diagnostic, USB backup for protocols and user profiles |
| Build Heritage | Engineered with >30 years of PCR system expertise |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer | analytikjena GmbH & Co. KG |
| Model | qTOWER 2.0 |
| Optical Channels | Up to 6 (configurable 1–6) |
| Excitation/Emission Filter Sets | 10 interchangeable Ex/Em combinations including FRET-mismatched pairs |
| Light Source | Triple high-efficiency LEDs (blue, red, white) |
| Detector | Channel-type photomultiplier tube (CPM) |
| Scanning Method | 8-channel fiber-optic scanning |
| Temperature Uniformity | < ±0.15 °C at 55 °C |
| Temperature Accuracy | ±0.1 °C at 72 °C |
| Max Heating Rate | 5.5 °C/s (adjustable 0.1–5.5 °C/s) |
| Max Cooling Rate | 4.0 °C/s (adjustable 0.1–4.0 °C/s) |
| Sample Capacity | 96-well plate, 0.2 mL tubes or 8-tube strips |
| Reaction Volume | 10–60 µL |
| Thermal Block | Gold-plated pure silver Peltier module |
| Hot Lid | 110 °C max, auto-pressure regulation up to 10 kg/plate |
| Detection Sensitivity | Single-copy DNA detection |
| Software | qPCRsoft v4.x with absolute quantification, melt curve analysis, relative quantification (ΔΔCt), allelic discrimination (SNP), expression ratio analysis, and GLP-compliant audit trail |
| Compliance | Designed for ISO/IEC 17025, CLIA, and FDA 21 CFR Part 11 environments (audit trail, electronic signature, user access control) |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Model | qTOWER3 84G |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 384-well format |
| Maximum Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Configuration | 6-channel excitation/emission system (configurable 1–6 channels) |
| Light Source | RGBW high-intensity long-life LEDs (blue, green, red, white) |
| Detector | High-sensitivity channel-type photomultiplier tube (PMT) |
| Detection Method | 16-channel fiber-optic scanning |
| Sensitivity | Single-copy DNA detection |
| Dynamic Range | 10 orders of magnitude |
| Recommended Reaction Volume | 2–30 µL |
| Linear Temperature Gradient | 24-column gradient |
| Thermal Module | Peltier-based with corrosion-resistant surface |
| Hot Lid Temperature | Up to 110 °C with auto-adjusting pressure (up to 30 kg/plate) |
| Noise Level | ≤45 dB(A) |
| Software | MIQE-compliant analysis suite with unlimited installation and lifetime free updates |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer | analytikjena GmbH & Co. KG |
| Type | Real-Time Fluorescence Quantitative PCR Instrument |
| Sample Capacity | 96-well format |
| Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Channels | 4–6 configurable |
| Excitation/Detection Filter Sets | 12 interchangeable combinations (including FRET-mismatched and protein melting-specific configurations) |
| Light Source | RGBW high-intensity LEDs (blue, green, red, white) |
| Detector | High-sensitivity photomultiplier tube (PMT) |
| Detection Method | 8-channel fiber-optic scanning system |
| Dynamic Range | 10 orders of magnitude |
| Sample Volume Range | 5–100 µL |
| Sample Block Material | Gold-plated pure silver thermal block |
| Lid Temperature Range | 30–110 °C with auto-adjusting contact pressure (up to 30 kg/plate) |
| Software | Free lifetime-upgradable qPCR analysis suite supporting absolute quantification, dual-standard-curve relative quantification, ΔΔCt with amplification efficiency correction, melting curve analysis, allelic discrimination/SNP genotyping, endpoint analysis, and efficiency calculation |
| Acoustic Noise Level | ≤45 dB(A) |
| Compliance | Designed and manufactured in accordance with ISO 13485, CE-IVD (where applicable), and GLP/GMP-aligned documentation practices |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Model | qTOWER3 G IVD |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Thermal Gradient | 12-column linear gradient |
| Excitation Sources | Four solid-state RGBW LEDs (blue, green, red, white) |
| Detection System | Channel-type Photomultiplier Tube (CPMT) |
| Software Interface | Bilingual (English & Chinese) |
| Regulatory Designation | IVD-certified per EU IVDR (Regulation (EU) 2017/746) |
| Brand | analytikjena |
|---|---|
| Origin | Shanghai, China |
| Model | qTOWER3 G |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Max Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Inter-Well Temperature Uniformity | ±0.15 °C |
| Cooling Rate | 6 °C/s |
| Gradient Range | 1–40 °C (linear or random mode, 12-column configuration) |
| Optical Channels | Up to 6 independently configurable fluorescence detection channels |
| Excitation/Detection Filter Sets | 12 interchangeable combinations including FRET-mismatched and protein melting-optimized sets |
| Light Source | RGBW high-intensity long-life LEDs (blue, green, red, white) |
| Detector | High-sensitivity channel-type photomultiplier tube (PMT) |
| Detection Method | 8-channel fiber-optic scanning (8 wells simultaneously) |
| Sensitivity | Single-copy DNA detection capability |
| Dynamic Range | 10 logs |
| Recommended Reaction Volume | 10–80 µL |
| Thermal Block | Gold-plated pure silver Peltier module |
| Software | MIQE-compliant analysis suite with unlimited free installation and lifetime updates |
| Noise Level | ≤45 dB(A) |
| Connectivity | USB, RS232, Ethernet |
| Dimensions (W×H×D) | 275 × 585 × 275 mm |
| Weight | ~30 kg |