| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Max. Heating Rate | 5°C/s |
| Temperature Accuracy | ≤ ±0.15°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.2°C |
| Display | 10.4″ TFT-LCD capacitive touch screen |
| Cooling Technology | Custom Ferrotec thermoelectric modules |
| Optional Block Surface | Gold-plated (Au) thermal block with TAS (Thermal Alignment System) |
| Connectivity | USB 2.0, RJ45 LAN, Bluetooth 4.0 (with PC wireless control adapter) |
| Temperature Range | 4–105°C |
| Gradient Function | 6 independent zones, adjustable gradient span 0.1–5.0°C per zone |
| Max. Cycle Number | 99 cycles with nested 2-level programming (suitable for nested PCR) |
| Time Increment/Decrement | 0–9 min 59 sec (enables Long PCR protocols) |
| Temp Increment/Decrement | 0–9.9°C (supports Touchdown PCR) |
| Power Input | AC 100–240 V, 50/60 Hz, 800 W |
| Dimensions (L×W×H) | 457 × 316 × 309 mm |
| Net Weight | 14 kg |
| Compatible Consumables | 0.2 mL 96-well PCR plates (full-skirt, half-skirt, unskirted), 0.2 mL single tubes, 0.2 mL 8-tube strips |
| On-board Memory | ≥1,000 protocols |
| Data Export | USB flash drive support |
| Power Failure Recovery | Auto-resume function with full protocol state retention |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–32 samples |
| Sample Volume Range | 20–1000 µL |
| Magnetic Bead Recovery Efficiency | ≥98% |
| Lysis Heating Temperature Range | Ambient to 120 °C |
| Elution Heating Temperature Range | Ambient to 120 °C |
| Vortex Mixing | Multi-mode, Adjustable Intensity |
| Decontamination Method | Integrated UV Lamp (254 nm) |
| Barcode Scanning | Optional |
| Compatible Reagent Format | Magnetic Bead Kits Only |
| Operating System | Windows 7/8 Embedded |
| Control Interface | Integrated Tablet PC + External PC/Laptop Support |
| Connectivity | USB, RS-232, Bluetooth, Wi-Fi |
| Protocol Management | Create, Edit, Delete Custom Protocols |
| Dimensions (L×W×H) | 440 × 380 × 450 mm |
| Weight | 20 kg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Operating Temperature | 10–40 °C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Magnetic Bead-Based Extraction System |
| Automation Level | Dedicated Fully Automatic Platform |
| Sample Throughput per Run | 1–32 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | 15–45 minutes |
| Compatible Consumables | 2.2 mL 96-well Deep-Well Plates |
| Interface | RS232 |
| Operating System | Microsoft Windows 7 / 8.1 / 10 |
| Dimensions (L×W×H) | 440 × 380 × 450 mm |
| Net Weight | 20 kg |
| Power Supply | AC 100–240 V, 50/60 Hz, 450 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NPA-96 |
| Instrument Type | Magnetic Bead-Based Automation |
| Automation Level | Dedicated Fully Automatic |
| Throughput | 96 Samples per Run |
| Sample Volume Range | 20–1000 µL |
| Magnetic Bead Recovery Efficiency | ≥99% |
| Temperature Control Range | +10 °C to +120 °C |
| Oscillation Modes | Vertical + Horizontal (at Lysis & Elution Stations) |
| Heating Method | Integrated Heated Film + TE Thermoelectric Modules |
| UV Sterilization Lamp | Manual/Automatic Scheduling |
| User Interface | 10-inch Color TFT LCD Touchscreen (Windows OS) |
| Barcode Scanner | Optional |
| Preloaded Protocols | ≥1000 |
| Connectivity | USB |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 907 × 495 × 571 mm |
| Weight | 81.5 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | NPA-96T |
| Instrument Type | Magnetic Bead-Based Automation |
| Automation Level | Dedicated Fully Automatic |
| Throughput per Run | 96 samples |
| Sample Volume Range | 20–1000 µL |
| Magnetic Bead Recovery Efficiency | ≥99% |
| Temperature Control Range | +10°C to +120°C |
| Heating Modules | Integrated Heated Block + Peltier (TE) Elements |
| Number of Heating Stations | 6 |
| Low-Temperature Storage Function | Yes |
| Temperature Display Resolution | 0.1°C |
| UV Sterilization Lamp | Integrated, Manual/Automatic Scheduling |
| User Interface | 10-inch Color TFT Touchscreen, Windows OS |
| Barcode Scanner | Optional |
| Preloaded Protocols | ≥1000 |
| Connectivity | USB |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 907 × 495 × 571 mm |
| Weight | 81.5 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NPA-32P |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Throughput | 32 samples per run |
| Sample Volume Range | 20–1000 µL |
| Magnetic Bead Recovery Efficiency | ≥98% |
| Inter-well CV | <3% |
| Lysis & Elution Heating Range | Ambient to 120 °C |
| Oscillation Modes | Multi-stage, adjustable |
| UV Decontamination | Integrated UV lamp |
| Barcode Scanning | Optional |
| Consumables | 96-well deep-well plate + magnetic rod sleeves |
| Touchscreen Interface | 8-inch embedded capacitive touchscreen |
| Dimensions (L×W×H) | 430 × 395 × 435 mm |
| Weight | 32.5 kg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-32P |
| Instrument Type | Magnetic Bead-Based |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–32 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Run | 15–45 minutes |
| Compatible Plate Format | 2.2 mL 96-well deep-well plates |
| Heating Module | Integrated deep-well block heater with uniform temperature control |
| Magnetic Separation | High-precision magnetic rod array with adjustable amplitude |
| Interface | USB & RS232 |
| Operating System Support | Windows 7/8.1/10 |
| Dimensions (L×W×H) | 430 × 395 × 435 mm |
| Net Weight | 32.5 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 500 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | B-48DA |
| Instrument Type | Dual-Block Gradient PCR Thermal Cycler |
| Sample Capacity | 2 × 48-well (0.2 mL tubes or 8-tube strips) |
| Heating Rate | >4 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Block Uniformity | ≤ ±0.2 °C across wells |
| Temperature Range | 4–105 °C |
| Gradient Range | 1–30 °C |
| Max Cycles | 99 with 2-level nesting |
| Time Increment/Decrement | 0–9 min 59 sec |
| Temp Increment/Decrement | 0.1–9.9 °C |
| Control Modes | Block mode and simulated tube mode |
| Interface | RS232, USB, LAN, Bluetooth |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Dimensions | 457 × 316 × 309 mm (L×W×H) |
| Safety & Compliance | Supports power-fail recovery, intelligent hot lid control, TAS thermal uniformity technology |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)C |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well |
| Max Heating Rate | ≥4 °C/sec |
| Temperature Accuracy | ≤±0.1 °C |
| Well-to-Well Uniformity | ≤±0.3 °C |
| Temperature Range | 4–105 °C |
| Gradient Range | 1–30 °C |
| Max Cycles | 99 with nested 2-level programming |
| Ramp Rate Adjustment | 0.1–9.9 °C per step (Touchdown PCR) |
| Time Increment/Decrement | 0–9 min 59 sec (Long PCR support) |
| Control Modes | Block mode and simulated tube mode |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Dimensions (L×W×H) | 345 × 250 × 270 mm |
| Net Weight | 8 kg |
| Interface | USB port |
| Data Protection | Power-fail resume function |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | TC-96/G/H(b)B |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Well-to-Well Uniformity | ≤±0.2 °C |
| Gradient Range | 1–30 °C |
| Temperature Range | 4–105 °C |
| Max Cycles | 99 with nested 2-level programming |
| Ramp Rate Adjustment | Yes |
| Touchdown PCR Support | 0.1–9.9 °C increment/decrement |
| Long PCR Support | Time increment/decrement up to 9 min 59 sec |
| Display | 6.5-inch color LCD touchscreen |
| Connectivity | USB port + Ethernet (LAN) |
| Dimensions (L×W×H) | 345 × 250 × 270 mm |
| Weight | 10 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Brand | Bioer |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | LineGene 9600 Plus |
| Sample Capacity | 96-well plate / 12×8 strip tubes / 96×0.2 mL single tubes (transparent bottom) |
| Dynamic Range | 1–10¹⁰ copies |
| Excitation Wavelength | 300–800 nm |
| Emission Wavelength | 500–800 nm |
| Compatible Dyes | F1: FAM/SYBR Green I |
| F2 | HEX/VIC/JOE/Cy3/NED/TAMRA |
| F3 | Texas Red/ROX |
| F4 | Cy5 |
| F5 | Cy5.5 |
| F6 | Reserved channel |
| Temperature Range | 4–105 °C (0.1 °C resolution) |
| Max Heating/Cooling Rate | 5.0 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Temperature Uniformity | ≤ ±0.3 °C |
| Thermal Control Modes | Block mode & Simulated Tube mode (volume-adaptive) |
| Sample Volume | 5–100 µL |
| Gradient Range | 1–36 °C |
| Heat Lid Temp | 30–110 °C (default 105 °C, auto-adjusting) |
| Fluorescence Detection Reproducibility | ≤ 5% CV |
| Full-plate Scan Time | ~5.5 s |
| Programmable Segments | Up to 20 per protocol |
| Max Cycles | 99 |
| Software Compatibility | Windows XP–8.1 |
| Minimum PC Spec | Pentium® 4 CPU, 512 MB RAM, 10 GB HDD, ≥1000 MB virtual memory |
| Power Input | 100–240 V AC, 50/60 Hz, 600 W |
| Dimensions | 410 × 386 × 352 mm |
| Interfaces | USB, RS232, Bluetooth |
| Certifications | CE, MET, RoHS2, PICC Product Liability Insurance, Ferrotec Peltier-based thermal module |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96A |
| Sample Capacity | 96-well plate / 12×8 strip tubes / 96×0.2 mL single tubes (bottom-transparent) |
| Max Heating Rate | 5.0°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.1°C |
| Fluorescence Channels | 6 (FAM/SYBR Green I |
| Dynamic Range | 1–10¹⁰ copies |
| Excitation Source | Long-life LED |
| Detection Mode | Bottom-scanning optical system |
| Thermal Block Control Modes | Block mode & Simulated Tube mode |
| Gradient Range | 1–36°C |
| Thermal Lid Temp Range | 30–110°C (auto-adjusting) |
| Power Input | 100–240 VAC, 50/60 Hz, 600 W |
| Dimensions | 410 × 386 × 352 mm |
| Certifications | CE, RoHS 2, MEC, MET, PICC Product Liability Insurance, China NMPA Registration No. 20153400273 |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-96A |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well |
| Max Heating Rate | 5.0°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.3°C |
| Excitation Source | Long-Life LED |
| Detection Mode | Bottom-Reading Optical System (Patented) |
| Thermal Control | Multi-Point PID with Peltier-based Semiconductor Modules (Ferrotec Custom) |
| Power Input | AC 100–240 V, 50/60 Hz, 650 W |
| Dimensions (L×W×H) | 410 × 386 × 352 mm |
| Net Weight | 28 kg |
| Interfaces | RS232, USB, Bluetooth |
| OS Compatibility | Windows 7 / 8.1 / 10 |
| Brand | bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | LineGene K Plus |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 48 × 0.2 mL (compatible with individual tubes and 8-tube strips) |
| Reaction Volume | 5–100 µL |
| Detection Channels | 4 |
| Excitation Sources | High-intensity LEDs (FAM/SYBR Green I |
| Block Temperature Range | 4–105 °C (0.1 °C resolution) |
| Max Heating Rate | 5 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Inter-well Uniformity | ≤ ±0.1 °C |
| Heat Lid Temperature Range | 30–110 °C (default 105 °C, auto-lift mechanism) |
| Independent Three-Zone Thermal Control | Adjustable gradient range 0.1–6 °C per zone |
| Operating System Compatibility | Windows XP / 7 / 8 / 10 |
| Interface Options | USB, RS232, Bluetooth |
| Power Input | 100–240 V AC, 50/60 Hz, 600 W |
| Dimensions | 410 × 386 × 352 mm |
| Weight | 28 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-48A |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 48-well |
| Maximum Heating Rate | 5°C/s |
| Temperature Accuracy | ≤ ±0.1°C |
| Well-to-Well Temperature Uniformity | ≤ ±0.3°C |
| Excitation Source | High-Intensity LED |
| Detection Method | Bottom-Optical Fluorescence Detection |
| Thermal Control Architecture | Triple-Zone Independent Peltier Control with Dual-Side Ferrotec Modules |
| Thermal Lid | Motorized Auto-Lift Lid with SOAK Function |
| Compatible Consumables | 0.2 mL Single Tubes (Flat/Capless & Dome/Capped), 0.2 mL 8-Tube Strips (Flat/Capless & Dome/Capped) |
| Interfaces | RS232, USB 2.0, Bluetooth 4.0 |
| Operating System Support | Windows 7/8.1/10 (64-bit) |
| Dimensions (L×W×H) | 410 × 386 × 352 mm |
| Net Weight | 28 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 600 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | LineGene Mini |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 16 × 0.2 mL tubes (flat, optically transparent caps) or 8 × 0.2 mL tubes (flat, optically transparent caps) |
| Reaction Volume | 10–100 μL |
| Dynamic Range | 1–10¹⁰ copies |
| Temperature Range | 0–100 °C (0.1 °C increment) |
| Temperature Control Accuracy | ≤ ±0.1 °C |
| Max Heating/Cooling Rate | 5 °C/s |
| Thermal Lid Temperature | 30–110 °C (adjustable, default 105 °C) |
| Fluorophore Channels | F1: FAM, SYBR Green I |
| F2 | VIC, HEX, TET, JOE, TAMRA, CY3 |
| F3 | ROX, Texas Red |
| F4 | CY5, Quasar-670 |
| Power Input | DC 24 V, 180 W |
| Dimensions (L×W×H) | 280 × 220 × 240 mm |
| Net Weight | 6.5 kg |
| Safety Features | Short-circuit/open-circuit detection for module/thermal lid/heat sink temperature sensors |
| Interface | USB |
| Preheat Time | None required |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | FQD-16A (Mini) |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 16-well (single tubes or 8-tube strips) |
| Max Heating Rate | 5.0 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Detection Channels | 4 |
| Detection Sensitivity | 1 copy |
| Compatible Consumables | 0.2 mL transparent/white/frosted PCR tubes and 8-tube strips |
| Optical Design | Top-scanning fluorescence detection with optimized light path to minimize stray light |
| Thermal Module | Custom Peltier-based system |
| Power Input | DC 24 V, 180 W |
| Dimensions (L×W×H) | 280 × 240 × 220 mm |
| Net Weight | 6.5 kg |
| Interface | RS232 |
| Operating System | Windows 7 / 8.1 / 10 |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | LineGene Mini S |
| Sample Capacity | 16 × 0.2 mL tubes or 2 × 8-tube strips (0.2 mL) |
| Power Input | 100–240 V, 50/60 Hz |
| Communication Interfaces | Ethernet port (for PC connectivity), Bluetooth 4.2 |
| Dimensions (L×W×H) | 240 mm × 180 mm × 160 mm |
| Net Weight | 4.0 kg |
| Regulatory Compliance | CE-IVD compliant per EN ISO 13485:2016 |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (TC-XP-E), 48×2 dual-block (TC-XP-D), 384-well (TC-XP-F), or 4-slide in situ hybridization platform (TC-XP-H) |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ±0.3 °C |
| Well-to-Well Uniformity | ±0.4 °C |
| Gradient Range | 1–30 °C across 12 or 24 columns |
| Temperature Control Range | 4–99.9 °C |
| Dimensions (L×W×H) | 470 × 340 × 260 mm |
| Net Weight | 10 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-16H |
| Extraction Method | Magnetic Bead-Based |
| Automation Level | Dedicated Fully Automatic |
| Throughput | 16 Samples per Run |
| Sample Volume Range | 50–10,000 µL |
| Consumables | Individual Tubes + Magnetic Rod Array Cartridge |
| Oscillation Mode | Multi-Mode, Multi-Stage Adjustable |
| Dimensions (L×W×H) | 430 × 395 × 435 mm |
| Net Weight | 29.5 kg |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-32E |
| Principle | Magnetic bead-based separation |
| Automation Level | Dedicated fully automated platform |
| Sample Throughput | 1–32 samples per run |
| Processing Time | As fast as 8 minutes per batch |
| Heating Capacity | Deep-well heating block with programmable lysis/elution temperature control (ambient to 95 °C) |
| Magnet Type | Permanent magnet rod array with dynamically adjustable oscillation amplitude |
| Sample Plate Compatibility | 2.2 mL 96-well deep-well plates |
| Interface | USB port for protocol transfer and system update |
| Oscillation Mode | Vertical reciprocating motion |
| Dimensions (L×W×H) | 430 × 395 × 435 mm |
| Net Weight | 28.5 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 350 W |
| Safety Features | Interlocked door sensor, built-in UV-C germicidal lamp (254 nm), aerosol-resistant sealing design |
| Modular Expandability | Optional 48-well adapter module available |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-96 |
| Instrument Type | Magnetic Bead-Based Automation |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–96 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | 8–15 minutes |
| Compatible Plate Format | 96-well deep-well plates (2.2 mL) |
| Interface | USB, LAN |
| Operating System Support | Windows 7 / 8.1 / 10 |
| Dimensions (L×W×H) | 907 × 495 × 571 mm |
| Net Weight | 81.5 kg |
| Power Input | AC 100–240 V, 50/60 Hz, 1000 W |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPA-96E |
| Extraction Method | Magnetic Bead-Based |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 96 |
| Compatible Plate Format | 2.2 mL 96-well Deep-Well Plate |
| Heating/Cooling | Integrated Heated and Cooled Elution Station (4–105 °C) |
| Oscillation Mode | Vertical Vibration |
| Dimensions (L×W×H) | 820 × 492 × 564 mm |
| Weight | 63 kg |
| Power Supply | AC 100–240 V, 50/60 Hz, 800 W |
| Interface | USB |
| HEPA Filtration | Yes |
| UV Sterilization | Built-in |
| Safety Features | Interlocked Door Sensor, Drip-Proof Partition, Real-Time Contamination Monitoring |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Model | NPAs-9600 |
| Instrument Type | Magnetic Bead-Based Automation |
| Throughput | 96 samples per run |
| Sample Volume Range | 20–1000 µL |
| Processing Time (96 samples) | ≤30 min |
| Power Supply | AC 220 V, 50 Hz, 1500 VA |
| Dimensions (L×W×H) | 1400 × 700 × 1980 mm |
| Sample Compatibility | Whole blood, swabs, urine, animal/plant tissues |
| Input Vessel Types | Cryovials, microcentrifuge tubes, collection tubes |
| Integrated Functions | Sample aliquoting, magnetic bead-based nucleic acid purification, and PCR master mix dispensing |
| Contamination Control | UV sterilization, HEPA-filtered laminar airflow, droplet capture technology |
| Human-Machine Interface | Full-color capacitive touchscreen with intuitive GUI |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format |
| Heating Rate | ≥3.0 °C/s |
| Temperature Accuracy | ≤±0.3 °C |
| Well-to-Well Temperature Uniformity | ≤±0.4 °C at 95 °C |
| Brand | Bioer |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TC-EA |
| Instrument Type | Gradient Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 48-well (dual-format), 4-slide in situ hybridization module |
| Heating Rate | ≥4 °C/s |
| Temperature Accuracy | ≤±0.1 °C at 55 °C |
| Well-to-Well Temperature Uniformity | ≤±0.2 °C |
| Gradient Range | 1–30 °C across 12 or 24 columns |
| Temperature Range | 4–105 °C |
| Dimensions (L×W×H) | 368 × 250 × 285 mm |
| Net Weight | 10.5 kg |
| Brand | Bioptic |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | GL100/400 |
| Instrument Classification | Conventional Nucleic Acid and Protein Analyzer |
| Minimum Sample Volume | 1 µL |
| Detection Technology | Capillary Gel Electrophoresis (CGE) with LED-Induced Fluorescence (LEDIF) |
| Sample Throughput | 96-well Auto-sampler |
| Consumable Format | Disposable Pre-cast Gel Cartridge |
| Included Modules | Integrated Sample Prep Platform (N-Glycan Release, Labeling & Purification Kit), Analysis Software with Data Export & Reporting Engine |
| Brand | Bioptic |
|---|---|
| Model | Qsep Mini |
| Origin | Jiangsu, China |
| Instrument Category | Ultra-micro Nucleic Acid and Protein Analyzer |
| Sample Volume Requirement | 1 µL |
| Analyte Types | DNA, Proteins |
| DNA Detection Limit | pg-level |
| Module Options | 8-, 12-, or 19-sample capacity |
| Disposables | Pre-cast, single-use gel cartridges |
| Brand | Bioptic |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Qsep1 |
| Instrument Classification | Conventional Nucleic Acid and Protein Analyzer |
| Minimum Sample Volume | 1 µL |
| Compatible Capillary Cartridges | 8-well, 12-well templates (Qsep1/Qsep1 Advance/Qsep1-Lite) |
| Form Factor | Portable Benchtop Analyzer |
| Brand | Bioptic |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | Qsep100 Advance |
| Pricing | Upon Request |
| Instrument Classification | Conventional Nucleic Acid and Protein Analyzer |
| Minimum Sample Volume | 1 µL |