| Brand | SBS |
|---|---|
| Origin | USA |
| Model | FNV-200 / CNV-100 |
| Viscosity Range (FNV) | 0.5–2.4×10⁶ cP |
| Viscosity Range (CNV) | 0.1–30 cP |
| Shear Rate Range (FNV) | ~10⁻⁴–10⁴ s⁻¹ |
| Temperature Range | −40 to 150 °C |
| Accuracy & Repeatability | <1% |
| Sample Volume (FNV) | ~110 cm³ |
| Sample Volume (CNV) | ~85 cm³ |
| Needle Material | Aluminum, Titanium, Stainless Steel, or Borosilicate Glass |
| Needle Density Range | 1.01–8.0 g/cm³ |
| Instrument Weight | 18.2 kg |
| Dimensions (H×W) | 55 × 36 cm |
| Falling Time Resolution | 0.001 s |
| Interface | RS-232 |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HPHTV-100 |
| Viscosity Range | 0.7–10⁶ cP (mPa·s) |
| Temperature Range | 0–100°C (operational), up to 150°C (chamber capability) |
| Pressure Rating | Up to 2000 psi |
| Accuracy & Repeatability | <1% |
| Sample Volume | 4.5 cm³ |
| Needle Materials | Aluminum, Titanium, Stainless Steel |
| Needle Density Range | 6–130 g/cm³ |
| Falling-Time Resolution | 0.001 s |
| Console | Microprocessor-based with RS-232 interface |
| Automatic Needle Handling | Yes |
| Instrument Weight | 7.3 kg (16 lbs) |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HTV-100 |
| Pricing | Available Upon Request |
| Viscosity Range | 1–10⁸ cP (mPa·s) |
| Temperature Range | −40 to 200°C (standard) |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ~1.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density Range | 6–1000 g/cm³ |
| Instrument Weight | 5.4 kg (12 lbs) |
| Measurement Resolution | 0.001 s |
| Interface | RS-232 |
| Sample Tube | Disposable, No Cleaning Required |
| Brand | SBS |
|---|---|
| Origin | USA |
| Model | PDVa-100 |
| Viscosity Range | 0.7–10⁷ cP (mPa·s) |
| Temperature Range | Ambient |
| Accuracy & Repeatability | <1% |
| Sample Volume | ~4.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density Range | 6–130 g/cm³ |
| Instrument Weight | 2 kg (4.4 lbs) |
| Measurement Principle | Capillary-based falling-needle viscometry with automated timing |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PDVdi-120 |
| Price | Upon Request |
| Viscosity Range | 2–10⁶ cP (mPa·s) |
| Temperature Range | Ambient (15–30 °C typical field use) |
| Accuracy & Repeatability | ±2% of reading |
| Sample Volume | ~25 mL |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | 2.916 g/cm³ |
| Total Weight | 0.38 kg (0.83 lbs) |
| Compliance | ASTM D5478, SAE AIR5704 |
| Brand | SBS |
|---|---|
| Origin | USA |
| Model | SV-100 |
| Viscosity Range | 0.5–10,000 mPa·s |
| Temperature Range | −40 to +150 °C |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ≥1.5 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | ~7.0 g/cm³ |
| Operating Pressure | Up to 2,000 psi |
| Compliance | ASTM D5478 |
| Instrument Weight | 7.3 kg |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UHPV-100 |
| Price | Upon Request |
| Viscosity Range | 0.7–20,000 cP (mPa·s) |
| Pressure Range | Up to 60,000 psi |
| Temperature Range | −40 to +150 °C |
| Accuracy & Repeatability | < ±2% |
| Sample Volume | ~10 cm³ |
| Needle Material | Aluminum, Titanium, or Stainless Steel |
| Needle Density | 7 g/cm³ |
| Instrument Weight | 68.0 kg (150 lbs) |
| Dimensions (H×W×D) | 61 × 107 × 61 cm |
| Brand | SCAVINI |
|---|---|
| Origin | Germany |
| Model | AD113 |
| Temperature Range | −10 °C to 40 °C |
| Ductility Extension Lengths | 50 cm, 100 cm, 150 cm |
| Load Measurement Range | 0–200 N |
| Load Resolution | 0.5 N |
| Temperature Control Accuracy | ±0.1 °C |
| Bath Material | Stainless Steel with PTFE-coated base |
| Cooling System | Integrated hermetic refrigeration compressor |
| Drive Mechanism | Variable-speed electric motor |
| Sample Capacity | 2 specimens simultaneously |
| Data Interface | RS-232 |
| Compliance | ASTM D113, ASTM D5976, IP 32, ISO 1208, GB/T 4508 |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | SD-1 |
| Standards Compliance | ASTM D6450, SH/T 0768, DL/T 1354 |
| Measurement Method | Closed-Cup Pensky-Martens Equivalent (Automated Peltier-Cooled Ignition Detection) |
| Sample Volume | ≤ 2 mL |
| Test Time | Typically < 10 min per sample |
| Display | 7-inch Capacitive LCD Touchscreen (Android OS 8.1) |
| Data Output | Thermal Printer (Built-in), USB Export, Optional Ethernet/Wi-Fi Module |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions | 320 × 280 × 220 mm |
| Weight | 8.5 kg |
| Brand | SDM |
|---|---|
| Origin | Italy |
| Model | 2050 |
| Temperature Range | Ambient to 180 °C (±0.3 °C stability) |
| Power Supply | 220 V, 50/60 Hz |
| Heating Power | 3200 W |
| Dimensions | 58 × 46 × 54 cm |
| Weight | 27 kg |
| Compliance | ASTM D972, IP 183 |
| Bath Material | Stainless Steel |
| Control System | PID Digital Controller with PT100A Sensor |
| Safety Features | Overtemperature Alarm, Low-Level Liquid Warning Light |
| Stirring | Motorized Stainless Steel Agitator |
| Construction | Insulated Dual-Wall Bath with Stainless Steel Lid and Precision Flowmeter Mounting Ports |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15400-4 |
| Bath Volume | 60 L |
| Test Temperature | 100 °C |
| Number of Bomb Positions | 4 |
| Maximum Bomb Charging Pressure | 1380 kPa |
| Cooling Method | Water-cooled bath |
| Voltage | 110/120 V or 220/240 V, 50/60 Hz |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 135 × 83 × 77 cm |
| Weight | 87 kg |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 15550-2 |
| Temperature Range | Ambient to 150 °C |
| Temperature Stability | ±0.1 °C |
| Bath Medium | Water or Oil |
| Bath Volume | 35 L |
| Power Rating | 1500 W |
| Voltage Options | 110/120 V or 220/240 V, 50/60 Hz |
| Dimensions (W×D×H) | 41 × 45 × 33 cm |
| Weight | 10 kg |
| Test Positions | 4 |
| Construction Material | Stainless Steel |
| Controller Type | Digital with Over-Temperature and Low-Level Safety Interlocks |
| Optional Accessory | Automated Pressure Monitoring Module |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | 16670-0 |
| Heating Method | Solid (metal block) |
| Temperature Range | Ambient to 100 °C |
| Test Positions | 4 |
| Voltage | 200–240 V, 50/60 Hz |
| Power Consumption | 3 kW |
| Dimensions (W×D×H) | 30 × 60 × 28 cm |
| Weight | 65 kg |
| Compliance | ASTM D525, D873, D2274, D4310, D7462 |
| Brand | Shanghai Xufeng |
|---|---|
| Origin | Shanghai, China |
| Model | XF-323 |
| Standards Compliance | GB/T 8017, ASTM D323, ISO 3007, IP 69 |
| Instrument Type | Benchtop, 2- or 4-position miniature bomb configuration |
| Measurement Range | 0–196 kPa (0–2 kgf/cm²) |
| Test Bomb | Full stainless-steel Reid vapor pressure bomb |
| Data Output | Integrated thermal dot-matrix printer |
| Dimensions (W×D×H) | 400 × 600 × 740 mm |
| Weight | 45 kg |
| Power Consumption | 2.0 kW |
| Optional Accessory | Certified mercury manometer (Japan-manufactured, for calibration verification) |
| Origin | Russia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SHATOX SX-300 |
| Pricing | Available Upon Request |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Model | SD 5096 |
| Power Supply | 220 V ±10%, 50 Hz |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Sensor | Industrial Pt100 Platinum Resistance Thermometer |
| Heating Power | 2100 W |
| Timing Range | 0.01 s to 99 h 99 min |
| Display | LED digital for both temperature and time |
| Sample Capacity | 4 test positions |
| Compliance | GB/T 5096, ASTM D130, ASTM D3241, SH/T 0023 |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SD-2801A |
| Temperature Control Range | Constant 25 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Penetration Measurement Accuracy | ±1 penetration unit |
| Maximum Penetration Depth | 700 penetration units |
| Penetration Time Control Accuracy | ±0.1 s |
| Resolution | 0.01 mm |
| Standard Cone Mass | 102.5 ± 0.05 g |
| Standard Needle Mass | 2.5 ± 0.05 g |
| Sample Cup Dimensions | Ø100 mm × ≥65 mm |
| Power Consumption | 80 W |
| Dimensions (L×W×H) | 340 × 282 × 515 mm |
| Net Weight | 11 kg |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SH0536 |
| Measurement Principle | Microcoulometric Titration (Ag⁺/Cl⁻ Reaction) |
| Compliance | SY/T 0536, ZBE 21001–1987 |
| Sample Types | Crude oil, residual fuel oil, heavy oil, refinery wastewater, industrial process water |
| Salt Range | 0.2 ppm – 10,000 mg NaCl/L |
| Chloride Range | 0.1 ppm – 10,000 mg Cl⁻/L |
| Accuracy | ≤20% (NaCl <3 mg/L), ≤10% (3–10 mg/L), ≤8% (≥10 mg/L) |
| Repeatability | ≤0.3 mg/L (NaCl <3 mg/L), ≤1.2 mg/L (3–10 mg/L), ≤8% RSD (≥10 mg/L) |
| Electrolytic Cell Design | Fritted Glass Disc (Replaces Ion-Exchange Membrane) |
| Control System | Embedded Microprocessor + PC-Based Data Acquisition & Visualization |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SH0702 |
| Price Range | USD 1,400 – 7,000 |
| Sample Mass | 25 g |
| Waste Flask Capacity | 500 mL |
| Measured Sediment Range | 0.5 % (m/m) |
| Test Stations | 2 |
| Filter Paper | Glass Fiber, Pore Size 1.6 µm, Diameter 47 mm |
| Vacuum Pressure | 40 kPa |
| Applicable Standards | SH/T 0701, SH/T 0702 |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 1000 W |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SH109 |
| Price Range | USD 7,000 – 14,000 |
| Standard Compliance | GB/T 17144-2021, ASTM D4530, ISO 10370:1993 |
| Measurement Range | 0.10–30.0 % (m/m) |
| Temperature Range | Ambient to 500 °C |
| Isothermal Accuracy | 500 °C ±2.0 °C (15 min hold) |
| Nitrogen Supply Pressure | 0–392 kPa (adjustable) |
| Gas Flow Control | 100–1000 mL/min, with auto-switching between 150 mL/min and 600 mL/min |
| Furnace Chamber Dimensions | Φ85 mm × 105 mm |
| Waste Collection Bottle Capacity | 200 mL |
| Heating Power | 1000 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| External Dimensions | 230 × 320 × 425 mm |
| Time Setting Resolution | <0.1 s |
| Display & Control | Color LCD touchscreen interface with real-time status indicators (Purge / Ramp / Soak) |
| Data Output | Optional thermal printer support |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SH113C |
| Temperature Range | +30 °C to –70 °C |
| Compliant Standards | GB/T 3535 |
| Detection Method | Imported photoelectric switch detection |
| Human-Machine Interface | 7-inch color LCD touch screen |
| Refrigeration System | Dual-stage hermetic compressor refrigeration |
| Bath Type | Dry well-shaped metal bath |
| Temperature Control Accuracy | < ±0.1 °C |
| Sample Capacity | Single test tube (marked fill line) |
| Data Storage | Up to 199 test records internally |
| Output Options | Built-in thermal printer |
| Power Management | Programmable auto-shutdown for compressor (0–50 min post-test) |
| Connectivity | TCP/IP network interface (optional remote firmware update) |
| Dimensions (W×D×H) | 650 × 480 × 620 mm |
| Net Weight | 75 kg |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SH6531 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Heating Power | 2 × 300 W |
| Temperature Control | Bidirectional thyristor-based continuous voltage regulation |
| Max. Ambient Temperature | ≤35 °C |
| Relative Humidity | ≤85% RH |
| Total Power Consumption | ≤600 W |
| Dimensions (L×W×H) | 50 × 38 × 32 cm |
| Weight | 13 kg |
| Sample Capacity | Dual-position (2 samples simultaneously) |
| Compliance | GB/T 6531, ASTM D473, ASTM D4870 |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SH6533A |
| Pricing | Upon Request |
| Brand | ShenKai |
|---|---|
| Origin | Shanghai, China |
| Model | CFR-A1 Auto |
| Measurement Principle | CFR Engine Method (Motor Method) |
| Measurement Range | 40–120 ON/CN |
| Instrument Type | Benchtop |
| Compliance Standards | ASTM D2699, ASTM D2700, GB/T 5487–2015, GB/T 503–2016 |
| Compression Ratio Range | 4:1 to 18:1 |
| Engine Speed | 900 ± 9 rpm (Motor Method), 600 ± 6 rpm (Research Method) |
| Cylinder Bore | 82.55 mm |
| Stroke | 114.3 mm |
| Displacement | 0.61 L |
| Cooling Jacket | Cast-iron monobloc with integrated coolant channel |
| Lubrication Pressure | 172–207 kPa |
| Cylinder Jacket Coolant Temp | 100 ± 1.5 °C |
| Intake Air Temp (Motor) | 38 ± 2.8 °C |
| Intake Air Temp (Research) | 52 ± 1 °C (at standard atmospheric pressure, auto-corrected) |
| Ignition Timing | Motor Method ε5.0 = 26 ± 1.5° BTDC (automatically adjusted per compression ratio) |
| Power Supply | AC 380 V ±10%, 50 Hz (main unit) |
| Total Power Consumption | 19 kW (12 kW + 7 kW) |
| Dimensions (W×D×H) | 1780 × 900 × 1400 mm |
| Weight | 1200 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | CFR-A1 |
| Application | Gasoline Octane Number (ON) Determination |
| Configuration | Benchtop |
| Test Range | 40–120 ON |
| Standards Compliance | ASTM D2699, ASTM D2700, IP 236, IP 237, EN ISO 5163, EN ISO 5164, GB/T 5487, GB/T 503 |
| Cylinder Bore | 82.55 mm |
| Stroke | 114.30 mm |
| Displacement | 0.61 L |
| Compression Ratio Range | 4:1 to 18:1 |
| Engine Speed | 900 ± 9 rpm (Motor Method), 600 ± 6 rpm (Research Method) |
| Cooling Water Temperature | 100 ± 1.5 °C |
| Lubricating Oil Pressure | 172–207 kPa |
| Power Supply | AC 380 V ±10%, 50 Hz / AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 1650 × 900 × 1420 mm |
| Net Weight | 1200 kg |
| Brand | ShenKai |
|---|---|
| Origin | Shanghai, China |
| Model | CFR-A1 |
| Application | Gasoline Octane Number Determination (Motor Method) |
| Principle | CFR Engine-Based Motor Method (ASTM D2700 / GB/T 503-2016) |
| Configuration | Benchtop Single-Cylinder CFR Engine System |
| Measurement Range | 40–120 MON |
| Compression Ratio Adjustment Range | 4:1 to 18:1 |
| Engine Speed (MON) | 900 ± 9 rpm |
| Lubricating Oil Pressure | 172–207 kPa |
| Lubricating Oil Temperature | 57 ± 8 °C |
| Coolant Temperature | 100 ± 1.5 °C |
| Intake Mixture Temperature (MON) | 149 ± 1.1 °C |
| Intake Air Temperature (MON) | 38 ± 2.8 °C |
| Intake Air Temperature (RON) | 52 ± 1 °C (at standard atmospheric pressure, auto-compensated) |
| Ignition Timing (MON) | 26 ± 1.5° BTDC (automatically adjusted per compression ratio) |
| Ignition Timing (RON) | Fixed at 13° BTDC |
| Displacement | 0.61 L (37.33 in³) |
| Cylinder Bore | 82.55 mm (3.25 in) |
| Piston Stroke | 114.3 mm (4.5 in) |
| Crankcase Dimensions | 480 × 380 × 680 mm (L×W×H) |
| Overall Instrument Dimensions | 1700 × 900 × 1400 mm (W×D×H) |
| Weight | 1000 kg |
| Power Supply | AC 380 V ±10%, 50 Hz |
| Total Power Consumption | 12 kW |
| Cooling Water Requirement | 60 L/min, 4–5 kg/cm² pressure, ≤24 °C inlet temperature |
| Data Storage Capacity | High-volume local storage with remote diagnostic capability |
| Software Platform | Windows 7-based proprietary control interface with real-time knock meter display, knock signal waveform, automatic report generation, and audit-trail-ready data logging |
| Brand | ShenKai |
|---|---|
| Origin | Shanghai, China |
| Model | CFR-A5 Auto |
| Application | Diesel Cetane Number Determination |
| Principle | Engine Method (Motor Method) |
| Configuration | Benchtop |
| Standards Compliance | GB/T 386–2010, ASTM D613–08 |
| Cylinder Bore | 82.55 mm |
| Stroke | 114.3 mm |
| Displacement | 0.61 L |
| Compression Ratio Range | 8:1 to 36:1 (motor-driven, computer-controlled) |
| Engine Speed | 900 ± 9 rpm |
| Injection Timing | 13° BTDC |
| Injector Opening Pressure | 10.30 ± 0.34 MPa |
| Fuel Flow Rate | 13.0 ± 0.2 mL/min |
| Injector Cooling Temperature | 38 ± 3 °C |
| Intake Air Temperature | 66 ± 0.5 °C |
| Jacket Coolant Temperature | 100 ± 2 °C |
| Lubricating Oil Pressure | 172–207 kPa |
| Lubricating Oil Temperature | 57 ± 8 °C |
| Base Compression Pressure | 3275 ± 138 kPa |
| Crankcase Vacuum | 0.25–1.5 kPa |
| Fuel Reservoir Elevation | 635 ± 25 mm above pump inlet centerline |
| Power Supply | 380 V, 50 Hz, Grounded |
| Total Installed Power | 19 kW (12 kW main unit + 7 kW auxiliary chiller) |
| Dimensions (W×D×H) | 1550 × 900 × 1720 mm |
| Weight | 1200 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | CFR-A5 AUTO |
| Application | Diesel Cetane Number (CN) Determination |
| Configuration | Benchtop |
| Standards Compliance | ASTM D613, ISO 5165, IP 41, GB/T 386 |
| Cylinder Bore | 82.55 mm |
| Stroke | 114.30 mm |
| Compression Ratio Range | 8:1 to 36:1 |
| Rated Engine Speed | 900 ± 9 rpm |
| CN Measurement Range | 0–100 (Typical: 30–85) |
| Fuel Injection Pressure | 10.30 ± 0.34 MPa |
| Injection Timing | 13.0° ± 0.2° BTDC |
| Cooling Jacket Temp | 100 ± 2 °C |
| Lubricating Oil Temp | 57 ± 8 °C |
| Power Supply | AC 380 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 1520 × 850 × 2000 mm |
| Net Weight | 1200 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1003-IXA |
| Temperature Control Range | Ambient to 100 °C (continuously adjustable) |
| Temperature Stability | ±0.01 °C |
| Bath Capacity | ~18 L |
| Bath Dimensions | Ø300 mm × 300 mm (hard-glass double-walled cylinder) |
| Number of Test Positions | 4 |
| Heating Power | 1600 W |
| Stirring Motor | 40 W, 1250 rpm, impeller Ø50 mm |
| Standard Capillary Set | 8 pieces conforming to SH/T 0173 |
| Operating Environment | 5–35 °C, 35–95% RH |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz |
| Dimensions (W×D×H) | 580 × 400 × 482 mm |
| Weight | 15 kg |
| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP2000-II |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Measurement Range | 0.005–5 wt% S |
| Detection Limit | 5 ppm (S) |
| Minimum Quantification Limit | 50 ppm (S) |
| Analysis Time | 30–300 s (default 100 s) |
| X-ray Tube | ≤20 kV, ≤1 mA, ≤10 W |
| Detector | Ultra-thin Beryllium-window Proportional Counter |
| Sample Form | Solid or Liquid (non-destructive, no digestion required) |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% at 30 °C |
| Power Supply | 220 V ±20 V, 50 Hz, ≤100 W |
| Dimensions | 285 × 405 × 165 mm (W×D×H) |
| Weight | 10 kg |
| Compliance | GB/T 17040, ASTM D4294 |
| Data Storage | Internal non-volatile memory with power-loss protection |
| Interface | Touchscreen GUI, USB data export |