Petroleum Specialized Analytical Instruments
Filter
Showing 1–30 of 1348 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RVP4500 Series |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IP170 |
| Pricing | Available Upon Request |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | CB10 |
| Compliance | ASTM D665, ASTM D7548, NACE TM0172, IP 135, ISO 7120, JIS K2510 |
| Test Positions | 2 independent stations |
| Automation Level | Fully automated water injection, temperature ramping, stirring, specimen immersion & retrieval |
| Interface | Touchscreen with embedded calibration datasets |
| Safety | Direct-drive low-torque motor with immediate stall detection and emergency stop |
| Integration | Compatible with CT10 Corrosion Rating Station for end-to-end automated evaluation |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | SP10 |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 1 kPa (typical ambient reference) |
| Temperature Control Resolution | 0.1 °C |
| Test Duration | <10 min |
| Flame Height Resolution | 0.1 mm |
| Connectivity | Ethernet (RJ45), USB (2 ports), Optional Printer via USB |
| Dimensions (W×D×H) | 330 × 390 × 413 mm |
| Weight | 10 kg |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | SP20 |
| Compliance | ASTM D1322, GB/T 3822 |
| Measurement Principle | Optical flame morphology detection with real-time height quantification |
| Test Duration | < 10 min per sample |
| Height Resolution | 0.1 mm |
| Data Storage Capacity | Up to 1,000,000 results |
| Connectivity | Ethernet, RS-232, USB |
| Display | 8-inch full-color touchscreen |
| Dimensions (L×W×H) | 330 × 390 × 413 mm |
| Integrated Sensors | Barometric pressure, ambient temperature, relative humidity |
| Fuel Calibration | Pre-loaded standard fuel database with auto-compensated smoke point correction |
| Brand | AD System |
|---|---|
| Origin | France |
| Model | TO10 |
| Test Standards | ASTM D3241, GB/T 9169, IP 323, ISO 6249 |
| Temperature Range | 100–380 °C |
| Pressure Drop Range | 0–750 mmHg (auto-bypass +700 mmHg) |
| Test Duration | 4–600 min |
| Air Flow Rate | 1.5 L/min (programmable) |
| Fuel Flow Control | Dual 5 mL syringe pumps (±1% accuracy) |
| Temperature Sensing | Class 1 K-type thermocouples |
| Cooling Method | Peltier + heat pipe (liquid-free) |
| Dimensions | 440 × 600 × 670 mm |
| Weight | 60 kg |
| Power Supply | 100–240 V, 8 A, 50/60 Hz |
| Operating Ambient | +10 to +35 °C |
| Connectivity | Ethernet (RJ45), USB ×2, optional USB printer |
| Data Storage | Integrated DR10 ITR interface with automated result transfer via Ethernet |
| Brand | AD SYSTEMS |
|---|---|
| Origin | France |
| Model | DR10 |
| Measurement Principle | Optical Interferometry |
| Thickness Range | 0–1200 nm |
| Volume Range | 0–0.5 mm³ |
| Measurement Points per Tube | 1200 |
| Scan Time | ≤15 min |
| Data Storage Capacity | Up to 100,000 records (internal database) |
| Interface | Ethernet (RJ45), USB 2.0 (for printer/data export), LAN/LIMS compatible |
| Dimensions (W×D×H) | 250 × 160 × 290 mm |
| Weight | 10 kg |
| Power Supply | 115–230 V AC, 2 A, 50/60 Hz |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | DT100 |
| Operating Principle | Digital Spot Test Image Analysis |
| Measurement Parameters | IC (0.1–5%), MD (0–100), DP (0–200) |
| Spot Acquisition Time | ~3 min per spot |
| Max Spots per Filter Paper | 16 |
| Imaging System | CCD digital camera with LED backlighting |
| Calibration | On-site using included calibration kit |
| Data Storage | USB drive, LAN network, or local printer (optional) |
| Interface | USB 2.0, RJ45 Ethernet |
| Dimensions | 305 × 487 × 390 mm |
| Weight | 20 kg |
| Power Supply | 230 V, 2 A, 50/60 Hz |
| Brand | AD Systems |
|---|---|
| Origin | France |
| Model | VD10 |
| Operating Pressure | Atmospheric |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–65 °C |
| Distillation Rate | 2–10 mL/min |
| Volume Detection Range | 0–100 mL |
| Volume Resolution | 0.1 mL |
| Brand | AYALYTICAL |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AgDDI |
| Price | Contact for Quote |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AcceleSep Petroleum Fraction Rapid Separation System |
| Pricing | Upon Request |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | 682T-HP |
| Sample Temperature Range | Up to 200°C (392°F) |
| Maximum Sample Pressure | >1500 psig |
| Optical Path Window Diameter | 5 cm |
| Sulfur Detection Range | 0.02–6.0 wt% |
| Application Focus | Crude Oil, Heavy Hydrocarbons, Pipeline Streams, Refinery Blending Processes |
| Compliance | Designed to meet internal industry specifications for refinery and midstream process monitoring |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 850 |
| Measurement Range | 0.6–3,000 cSt |
| Units | mm²/s (cSt) |
| Timer Accuracy | ±0.0025 s |
| Temperature Range | 20–110 °C |
| Temperature Stability | ±0.01 °C (20–100 °C), ±0.03 °C (>100 °C) |
| Bath Capacity | 7.5 L |
| Capillary Type | Four S-Flow viscometers (certified calibration optional) |
| Detection Method | Optical meniscus detection |
| Display | Integrated LCD interface |
| Cleaning | Manual solvent injection |
| Cooling | Internal helical coil compatible with external chiller (water/oil bath) |
| Dimensions | 435 × 475 × 620 mm |
| Weight | 32 kg |
| Compliance | CE certified |
| Auxiliary Requirement | External air compressor (5–6 bar at 50 L/min) |
| Optional | External thermal printer, PC-based software module (non-intrusive integration) |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D611 |
| Pricing | Available Upon Request |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-262A |
| Price | Upon Request |
| Measuring Range | Ambient Temperature to 150 °C |
| Stirring Speed | 0–1200 rpm |
| Heating Power | 25 W |
| Brand | Ankersmid |
|---|---|
| Origin | Germany |
| Model | OilHealth Probe |
| Type | Online Instrument |
| Application | Lubricating Oil Condition Monitoring |
| Core Technology | Multi-parameter Spectroscopic Analysis (FTIR + Electrochemical RULER + Viscosity Correlation) |
| Compliance Context | Designed for ISO 4406, ASTM D7883 (RULER), ASTM E2412 (FTIR), and OEM lubricant life extension protocols |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 660 |
| Compliance | ASTM D5, D217, D937, D1321, D1403, D1831, D2884 |
| Power Supply | 220 V / 50 Hz, 50 W |
| Safety Certification | CE |
| Penetration Range | 0–50 mm |
| Cone Mass | 47.5 g (standard) |
| Needle Mass | 2.5 g (ASTM D5-compliant) |
| Timer Resolution | 0.1 s, Programmable Duration (1–60 s) |
| Temperature Control | Compatible with external thermostatic water baths (e.g., 25 °C ± 0.1 °C) |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABA 300 & ABA 500 |
| Detection Method | Closed-Cup (Abel) |
| Operation Mode | Fully Automatic |
| Temperature Range | 10 °C to 110 °C (air-cooled) |
| Ignition Source | Electronic (encapsulated hot-wire) |
| Repeatability | ±1.4 °C |
| Compliant Standards | ISO 13736, ISO 1516, ISO 1523, GB/T 21789, GB/T 21775, GB/T 21792 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ABA 500 |
| Detection Method | Closed Cup |
| Operation Mode | Automatic |
| Temperature Range | −35 °C to +130 °C |
| Ignition Method | Electronic (Encapsulated Hot Wire) |
| Applicable Standards | ISO 13736, ISO 1516, ISO 1523, GB/T 21789 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest GmbH, a company of Anton Paar) |
| Product Category | Imported |
| Model | BPA |
| Price | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Callisto 100 |
| Temperature Range | –60 °C to +45 °C |
| Cooling Profile | Programmable stepwise or linear (6–100 °C/h) |
| Calibration | Automated calibration for sample/jacket temperature and vacuum |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 test results |
| User Programs | Up to 90 customizable methods |
| External Cooling Required | Yes (280 W at –20 °C) |
| Dimensions | 340 × 580 × 310 mm (W × D × H) |
| Weight | 14 kg |
| Power Supply | 100–240 V, 50/60 Hz, 290 VA |
| Interfaces | 4× USB, 1× RS232, 1× LAN, 1× VGA |
| Data Export | XLS, PDF via USB flash drive |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CLA 5 |
| Detection Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automated |
| Temperature Range | Up to 400 °C (°C/°F selectable) |
| Ignition Source | Pressurized Propane or Butane Gas |
| Compliant Standards | ASTM D92, ISO 2592, IP 36, DIN 51376, JIS K 2265 |
| Origin | France |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D525 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Diana 700 |
| Test Pressure | Atmospheric (101.3 kPa) |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling Bath Range | 0–80 °C |
| Distillation Rate | 2–12 mL/min |
| Volume Detection Range | 0–103.5 mL |
| Volume Resolution | 0.01 mL |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar (Petrotest GmbH, a company of Anton Paar) |
| Model | GUM |
| Operating Temperature Range | Ambient to 246 °C (air only) |
| Sample Positions | 5 simultaneous |
| Air Supply | 2–4 bar, oil-free and filtered |
| Steam Supply | Inlet temperature ≈140 °C, pressure 3–4 bar, controlled flow rate |
| Power Requirements | 230 V, 50/60 Hz, 2000 W (air mode) |
| Dimensions (W × D × H) | 400 × 400 × 720 mm |
| Weight | 44 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | PMA 500 |
| Detection Method | Closed Cup Method |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + X °C to 410 °C |
| Ignition Method | Electric Spark Ignition |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH (Petrotest Division) |
| Type | Imported Instrument |
| Model | PetroOxy |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PMA 300 |
| Test Method | Closed-Cup (Pensky-Martens) |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient + ~10 °C to 370 °C |
| Ignition Source | Electronic (Encapsulated Hot-Wire) |
| Compliant Standards | ASTM D93, EN ISO 2719, IP 34, JIS K2265-3, GB/T 261 |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Instrument |
| Model | PNR 12 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar GmbH |
| Type | Imported Instrument |
| Model | TAG 300/500 |
| Detection Method | Closed-Cup (TAG) |
| Operation Mode | Fully Automatic |
| Sample Temperature Range | −35 °C to +130 °C |
| Ignition Source | Ceramic-Coated Electric Igniter |
| Compliant Standards | ASTM D56, ASTM D3941, ASTM D3934, ISO 1516, ISO 1523 |