| Key | Brand: OEKO Instruments |
|---|---|
| Chamber Dimensions (ID × H) | Φ25×40 cm / Φ30×50 cm / Φ40×60 cm / Φ50×70 cm |
| Temperature Range | 100–132 °C |
| Humidity Condition | 100 % RH saturated steam |
| Pressure Range | Ambient + 0–4 kgf/cm² (≈0–392 kPa gauge) |
| Safety Certification | Dual-stage pressure relief, dual overheat protection, water-level sensor auto-refill, 140 °C tank-rated pressure vessel (2.65 MPa hydrostatic test compliance) |
| Max Continuous Operation | 400 hours |
| Steam Generation | Independent steam generator chamber |
| Air Purge | Pre-test and in-process cold-air purge cycle |
| Compliance | Designed for IPC-TM-650 2.6.25, JIS C 5023-4, MIL-STD-202 Method 108, and ISO 16750-4 environmental stress screening protocols |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 100–132 °C |
| Humidity Condition | 100 % RH saturated steam |
| Pressure Range | 0–4 kgf/cm² (gauge) above atmospheric pressure |
| Internal Dimensions (PCT-25) | Φ25 cm × 40 cm |
| Internal Dimensions (PCT-30) | Φ30 cm × 50 cm |
| Internal Dimensions (PCT-40) | Φ40 cm × 60 cm |
| Internal Dimensions (PCT-50) | Φ50 cm × 70 cm |
| Sealing System | Patented dual-contact gasket design |
| Safety Systems | Dual-circuit high-temp solenoid valve, overpressure/overtemperature cut-off, mechanical anti-opening door lock, manual & automatic pressure release |
| Brand | OEM / Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pressure Range | 0–4 kgf/cm² above atmospheric pressure (0–392 kPa gauge) |
| Temperature Range | 100–132 °C |
| Humidity Condition | 100% RH saturated steam |
| Internal Chamber Dimensions (D×H, cm) | Φ25×40 |
| Temperature Control Accuracy | ±0.1 °C (PID-controlled digital controller) |
| Safety Features | Dual overheat protection, mechanical safety valve, interlocked door switch, auto-water replenishment, condensate purge system, ABS insulated door cover, integrated silicone door gasket |
| Brand | OEM / Third-party Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Pricing | USD 3,950–6,800 (FOB) |
| Internal Dimensions (W×H×D) | Ø250×300 mm / Ø350×400 mm / Ø450×500 mm / Ø650×600 mm |
| Chamber Material | ASTM A240 Type 316 Stainless Steel |
| External Casing | Powder-coated or 304 stainless steel |
| Temperature Range | +10°C to 132°C (optional 147°C custom calibration) |
| Pressure Range | 0–2.5 kg/cm² gauge (0–35.5 psi), max absolute pressure 3.5 kg/cm² |
| Heating Method | Immersed electric heating elements |
| Humidification | Direct steam generation via electric heater |
| Water Replenishment | Stainless steel float valve system |
| Cycle Control | LED digital timer with temperature-triggered start (ASTM E2035-compliant timing logic) |
| Safety Interlocks | Dual mechanical pressure lock, overpressure relief valve (ASME BPVC Section VIII compliant), door-seal integrity verification prior to pressurization |
| Power Supply | 220–240 VAC, 50/60 Hz, single-phase |
| Thermal Stability | ±0.5°C at setpoint (121°C) |
| Circulation | Natural convection steam atmosphere |
| Brand | Peiyi |
|---|---|
| Origin | Shanghai, China |
| Model | PY-NS01 |
| Ignition Source | Liquefied Petroleum Gas (LPG) or Town Gas |
| Burner Inner Diameter | 9.5 ± 0.5 mm, Length: ~100 mm |
| Adjustable Flame Height | 20–100 mm |
| Flame Application Time Range | 0–99 min 99 sec |
| Chamber Volume | 0.05 m³ |
| Chamber Material | Stainless Steel or Powder-Coated Steel |
| Power Supply | AC 220 V, 50 Hz, 5 A |
| Compliance | GB 8410–2006, FMVSS 302, ISO 3795, ASTM D5132 |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DMA 8000 |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | –196 °C to 600 °C (with LN₂ cryogenic cooling) |
| Frequency Range | 0.01–300 Hz |
| Cooling Rate | ≤15 min from ambient to –190 °C |
| Liquid Nitrogen Consumption | ~1 L per typical low-temperature DMA run |
| Sample Modes | Dual/Triple Cantilever, 3-Point Bending, Tension, Compression, Shear, and TMA Mode |
| Humidity Control Range | 10–90 % RH (optional humidity generator) |
| Optical Access | Quartz furnace viewport for in-situ visual monitoring and UV-curable sample testing |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 4000 / DSC 6000 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –100 °C to 600 °C (with optional cryogenic and high-temp accessories) |
| Temperature Accuracy | ±0.1 °C (traceable to NIST standards) |
| Heating/Cooling Rate | 0.1–100 K/min (programmable in 0.1 K/min increments) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DSC 8000 |
| Simultaneous Sample Capacity | Multiple |
| Instrument Type | Power-Compensated DSC |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | 0.01 °C/min to 300 °C/min |
| Dynamic Heat Flow Range | ±800 mW |
| Furnace Material | Platinum-Iridium Alloy |
| Modulated DSC (MDSC®) | Standard |
| Cooling Options | Two-stage mechanical cooler, three-stage mechanical cooler, automated liquid nitrogen cooling |
| Dual Digital Mass Flow Controllers | Standard |
| Optional Accessories | 96-position autosampler, high-pressure cell (up to 600 psi), UV photo-DSC module, isolated sample chamber for hazardous materials |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DSC 8500 |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | up to 750 K/min (controlled), >1000 K/min (free cooling) |
| Heat Flow Dynamic Range | ±800 mW |
| Calorimetric Accuracy | < ±0.2% |
| Sensitivity | 0.18 µW |
| Data Acquisition Rate | up to 100 Hz |
| Standard Features | Dual-channel digital mass flow controllers, automated lid, integrated cooling accessory |
| Optional Accessories | 96-position autosampler, high-pressure DSC cell, isolated DSC module, photo-DSC unit, DSC–Raman hyphenated system |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TG-MS |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Pyris™ |
| Pricing | Available upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA 8000 |
| Pricing | Upon Request |
| Temperature Range | −150 °C to 1600 °C |
| Heating Rate | 0.01–100 °C/min |
| Temperature Stability | ±0.01 °C (at isothermal hold) |
| Maximum Sample Mass | 2 g (standard), up to 5 g (optional crucible) |
| Atmosphere Control | Dual-gas MFC with programmable switching (N₂, O₂, Ar, He, air, forming gas) |
| Balance Resolution | 0.1 µg |
| DSC Sensitivity | < 0.1 µW |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA6000 |
| Pricing | Upon Request |
| Heating Rate (°C/min) | Up to 100 |
| Temperature Range (°C) | −150 to 1500 |
| Temperature Stability | ±0.01 °C |
| Maximum Sample Weight (g) | 2000 |
| Atmosphere Control | Dual-gas MFC with Auto-Switching (Inert, Oxidizing, Reducing) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TG-GC/MS |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Manufacturer Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Imported |
| Model | TG-hiden MS |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | TG-IR |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PerkinElmer TG-IR-GC/MS |
| Pricing | Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 4000 |
| Temperature Range | Ambient to 1000 °C |
| Balance Capacity | 1500 mg |
| Balance Resolution | 0.2 µg |
| Balance Accuracy/Precision | ±0.02% / ±0.01% |
| Heating Rate | 0.1–200 °C/min |
| Temperature Accuracy/Precision | ±1 °C / ±0.8 °C |
| Sample Pan Volume | 180 µL |
| Atmosphere Options | Static or dynamic, including N₂, Ar, He, CO₂, air, O₂, and other inert or reactive gases |
| Integrated Mass Flow Controller | Standard |
| Optional Autosampler | 45-position |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TGA 8000 |
| Instrument Type | General-Purpose |
| Temperature Range | –20 °C to 1200 °C |
| Heating Rate | 0.1–500 °C/min |
| Gas Control | Dual-path mass flow control (balance purge + sample purge), optional 3-gas mixing module |
| Automation | 48-position autosampler with AccuPik™ compatibility |
| 联用接口 | Integrated heated divert valve and sniffer for FTIR/MS/GC-MS coupling |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TMA 4000 |
| Pricing | Available Upon Request |
| Brand | Controls (Europe) |
|---|---|
| Origin | Germany |
| Model | PermeaTORR AC+ |
| Power Supply | 24 Vdc / 3 Adc |
| Weight (pump + case) | 10 kg |
| Data Storage | ≥1000 test records (internal microSD) |
| Interface | Touchscreen display + Bluetooth-enabled mobile remote control |
| Vacuum Source | Integrated oil-free miniature vacuum pump |
| Hose Length | Fixed-length flexible hose up to 5 m |
| Compliance | GB/T 50082–2024, SIA 261/1:2019, ASTM C1202, EN 12390-8, Cembureau O₂ permeability protocol |
| Brand | Pharma Test |
|---|---|
| Origin | Germany |
| Model | PT-TD300 |
| Standards Compliance | USP <616> Method 1 & 2, EP <2.9.34>, DIN EN ISO 787-11, ASTM B527 |
| Sample Weight Input | Via Connected Balance (RS-232 or USB) |
| Density Calculation | Apparent Density, Tapped Density, Hausner Ratio, Carr Index |
| Output | Integrated Thermal Printer, USB Flash Drive Export (Methods & Reports) |
| Software Architecture | Standalone Embedded System with GLP-Compliant Audit Trail |
| Regulatory Alignment | Designed for GMP/GLP Laboratories, Supports 21 CFR Part 11 Readiness (User Authentication, Electronic Signatures Optional via Firmware Update) |
| Brand | Pharma Test |
|---|---|
| Origin | Germany |
| Model | PTG-S5 |
| Instrument Type | Fully Automated Powder Flowability Analyzer |
| Standards Compliance | USP <1174>, EP <2.9.36>, EP <2.9.16>, ISO 4324 (1983) |
| Funnel Volume | 450 mL |
| Heap Angle Range | 1–65° |
| Heap Volume Range | 0.1–275 mL |
| Bulk Density Range | 0–6.0 g/mL |
| Sample Mass Range | 1 mg–325 g |
| Flow Time Range | 0.1–999 s |
| Nozzle Orifices | 6, 8, 10, 15, 25 mm |
| Display | 7-inch color touchscreen |
| Dimensions (L×W×H) | 50 × 55 × 90 cm |
| Construction | Electropolished stainless steel housing |
| Software | 21 CFR Part 11 compliant with audit trail, electronic signatures, and secure data storage |
| Key | Temperature Range: −40 °C to +150 °C (optional down to −70 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temp. Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temp. Uniformity | ±0.5 °C |
| Temp. Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen controller |
| Internal Construction | SUS304 stainless steel |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (220 V optional) |
| Compliance | GB10589, GB10592, GB11158, GB/T5170.2, GB/T5170.5, GB2423.1/2/22, GB2424.1 |
| Brand | Phinix |
|---|---|
| Model | PX03002 |
| Standards Compliance | UL 94 HB/V0/V1/V2/5VA/5VB, IEC 60695-11-10/-11-20, ISO 1210/9770/9773, GB/T 2408/5169.17 |
| Chamber Volume | >0.75 m³ |
| Viewing Window | Large tempered glass, interior illumination ≤20 lux |
| Flame Source | HUMBOLDT Trillium burner (ID 9.5±0.3 mm, ASTM D5025 compliant) |
| Flame Orientation | Motorized 0°/20°/45° adjustment |
| Ignition | High-voltage pulse auto-ignition |
| Gas Control | Imported rotameter + differential pressure sensor + precision pressure regulator + solenoid valve |
| Sample Positioning | Motorized linear stage (horizontal/vertical), software-controlled |
| Control System | PLC + industrial touchscreen HMI |
| Safety Features | Auto gas cutoff after 10 min idle, flame duration alert, real-time V (mm/min) calculation and display |
| Optional | 50W/500W flame calibration kit with ±0.1°C certified thermocouples |
| Power | AC 220 V, 50 Hz, 2 A |
| Dimensions (Upper Cabinet) | 1350×700×1000 mm (W×D×H) |
| (Lower Cabinet) | 1350×700×650 mm |
| Weight | ~70 kg |
| Brand | Phinix |
|---|---|
| Model | PX04006 |
| Combustion Chamber Dimensions | 750(W) × 300(D) × 900(H) mm |
| Control Cabinet Dimensions | 650(W) × 650(D) × 1600(H) mm |
| Power Supply | AC 220 V, 50 Hz, 16 A |
| Weight | ~180 kg |
| Fuel Source | Propane (≥95% purity) |
| Heat Flux Calibration Range | 0–100 kW/m² |
| Heat Flux Accuracy | <±3% |
| Response Time | 0.2 s |
| Emissivity | >0.95 |
| Radiant Heat Source | Nine T150 quartz infrared tubes (13 kW/m² ±4 kW/m²) |
| Convective Heat Source | Two 45°-inclined Meker burners (38 mm outer diameter, 5/16″ inner orifice), 25 kW total output |
| Total Incident Heat Flux | 84 kW/m² ±2 kW/m² |
| Temperature Measurement | OMEGA thermocouples with stainless-steel calibration disk, 0–1100 °C range, 0.1 °C display resolution |
| Cooling System | Integrated chiller (10 L/min flow rate), water-cooled aluminum heat sink plate (340 × 286 mm), portable closed-loop water source |
| Automation | PLC-controlled electromechanical positioning modules for specimen and heat flux sensor actuation |
| Software Platform | NI LabVIEW-based HMI with real-time curve visualization, data logging, audit-trail-enabled reporting, and GLP-compliant export formats |
| Brand | Phoenix |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PX01005 |
| Price Range | USD 4,200 – 7,000 |
| Dimensions | 650(W) × 375(D) × 530(H) mm |
| Power Supply | AC 220 V, 50/60 Hz, 2 A |
| Weight | ~30 kg |
| Required Gas Sources | O₂ ≥99.99%, N₂ ≥99.99%, C₃H₈ ≥95% |
| Oxygen Sensor Type | Paramagnetic |
| Oxygen Measurement Accuracy | ±0.1% vol |
| Control System | PLC + 7″ HMI Touchscreen |
| Optional | PC-based LOI control & data management software |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,100 (approx.) |
| Temperature Range | 100–147 °C (steam temperature) |
| Humidity | 100% saturated steam |
| Humidity Control Stability | ±3% RH |
| Operating Pressure | 1.2–2.89 kg/cm² (absolute, incl. 1 atm) |
| Test Duration | 0–999 h |
| Pressure Ramp Time | 0–1.04 kg/cm² in ~45 min |
| Temperature Uniformity | ±0.5 °C |
| Temperature Display Resolution | 0.1 °C |
| Pressure Uniformity | ±0.1 kg/cm² |
| Humidity Uniformity | ±3% RH |
| Internal Chamber Design Pressure Rating | 4 kg/cm² |
| Brand | OEM / Third-Party Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Temperature Range (Loaded) | -40 °C to +85 °C |
| Temperature Range (Unloaded) | -70 °C to +150 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Range | 20–98% RH |
| Humidity Stability | ±2.5% RH |
| Humidity Uniformity | ±4.0% RH |
| Compliance Standards | IEC 61215, IEC 61646, IEC 62108, IEC 61730, UL 1703, IEEE 1513, GB/T 5170.2, GB/T 5170.5 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Sensor Highway II / III |
| Instrument Category | Acoustic Emission (AE) & Multi-Parameter Structural Health Monitoring System |
| Operating Temperature Range | -35°C to +70°C |
| Power Supply | 10–28 VDC or 95–250 VAC |
| Power Consumption | 15 W (typical) |
| Dimensions | 40 cm × 50 cm × 20 cm |
| AE Channels | Up to 16 (expandable via four 4-channel micro-AE cards) |
| AE Frequency Bandwidth | 1 kHz – 1 MHz |
| Vibration Bandwidth | 1 Hz – 20 kHz |
| A/D Resolution | 18-bit |
| Sampling Rate | 20 MS/s (AE), 10 kS/s (16 low-speed external parameter channels) |
| IP Rating | IP67-rated enclosure (for outdoor deployment) |
| Communication Interfaces | Gigabit Ethernet, RS-232, RS-422, USB, CompactFlash |