Physical Property Testing Instruments
Filter
Showing 3301–3330 of 12075 results
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Industrial Distributor |
| Price | USD 14,200 (FOB) |
| Chamber Volume | 75.4 L (Ø400 mm × L600 mm) |
| External Dimensions | 900 × 700 × 1600 mm (W×D×H) |
| Inner Tank Material | SUS316 Stainless Steel (3 mm thick) |
| Outer Casing | Optional SUS304 or Powder-Coated Steel |
| Insulation | Rock Wool + Rigid Polyurethane Foam (≥80 mm) |
| Steam Generator | Titanium Alloy Heating Element (Corrosion-Resistant) |
| Control System | Delta DOP-107EV Color Touch HMI + PLC-Based PID Algorithm |
| Temperature Sensor | PT-100 Platinum RTD (Class A, ±0.15 °C) |
| Pressure Indication | Analog Bourdon Tube Gauge (0–300 kPa, ±1.6% FS) |
| Humidity Control | Saturated Steam Generation with Auto-Water Refill (No Downtime Required) |
| Compliance | GB/T 10586–1989, GB/T 2423.3–2016 (IEC 60068-2-3), MIL-STD-810G Method 502.5, GJB 150.9A–2009, GB/T 2423.34–2012 (IEC 60068-2-52), MIL-STD-883K Method 1004.2 |
| Brand | Haver & Boecker |
|---|---|
| Origin | Germany |
| Model | Stainless Steel Frame Test Sieve |
| Compliance | EN 10204 3.1 available on request |
| Calibration service | Available for new and legacy sieves |
| Material | AISI 304 or 316 stainless steel |
| Frame thickness | Standard 25 mm (custom options available) |
| Diameter options | 200 mm, 300 mm, 450 mm, 500 mm |
| Mesh range | 20 µm to 125 mm nominal aperture |
| Mounting | Precision-ground flange for ISO/ASTM-compliant stacking |
| Surface finish | Electropolished or mechanically polished per application requirements |
| Brand | Haytham |
|---|---|
| Model | Blue Box1200-32 |
| Origin | Guangdong, China |
| Type | Domestic |
| Supplier Type | Authorized Distributor |
| Pricing | Upon Request |
| Brand | Haytham |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BlueBox 2000-1Q |
| Pricing | Upon Request |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HCX09A |
| Pricing | Available Upon Request |
| Thermal Conductivity Range | 0.05–20 W/(m·K) |
| Temperature Measurement Accuracy | Better Than Class 0.2 |
| Measurement Uncertainty | ±3% |
| Heating Power Control Resolution | ±1% |
| Sample Geometry | Cylindrical, Ø15–30 mm × 5–30 mm |
| Temperature & Atmosphere | Customizable per User Specification |
| Data Acquisition | Fully Automated via PC Interface |
| Key | Origin: Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Temperature Range | RT–300 °C |
| Heating Rate Options | (12 ± 1) °C/6 min or (5 ± 0.5) °C/6 min |
| Temperature Accuracy | ±1 °C |
| Deflection Measurement Range | 0–10 mm |
| Deflection Resolution | 0.001 mm |
| Heat Transfer Medium | Methyl Silicone Oil |
| Heating Power | 4 kW |
| Cooling Mode | Natural cooling above 150 °C |
| Power Supply | AC 220 V, 20 A, 50 Hz |
| Dimensions (L×W×H) | 540 × 520 × 1360 mm |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Tabletop Dimensions | 500 × 500 mm |
| Shaker Body Dimensions | 500 × 450 × 500 mm |
| Mounting Pattern | 25 × M10 threaded holes on tabletop |
| Vibration Axes | Vertical (Y-axis) and Horizontal (X-axis) |
| Frequency Range | 1–5000 Hz, resolution 0.01 Hz |
| Peak-to-Peak Displacement | 0–4 mm adjustable |
| Maximum Load Capacity | 75 kg |
| Rated Sinusoidal Force | 1125 kgf (11.03 kN) |
| Maximum Acceleration | ≤15 g |
| Waveform | Sine (full- or half-cycle) |
| Test Duration Setting | Programmable in seconds (0–999,999 s) |
| Power Consumption | 3.8 kW |
| Input Current | ≤15 A |
| Supply Voltage | 380 V ±20%, 3-phase, 50/60 Hz |
| Operating Temperature | −10 °C to +60 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Recommended Ambient | ≤28 °C with adequate ventilation |
| Brand | Hegewald & Peschke |
|---|---|
| Origin | Germany |
| Model | Inspekt Blue |
| Load Capacity | 20 kN or 30 kN |
| Frame Type | Dual-column, benchtop |
| Test Height | 1100 mm |
| Test Width | 420 mm |
| Load Measurement Range | 0.4%–100% of rated capacity |
| Compliance | EN ISO 7500-1, ASTM E4, EN 10002-2 |
| Drive System | Brushless motor, gearless transmission |
| Control Options | Integrated control panel + optional PC-based LABMASTER software |
| Standard Safety Features | Overload protection, automatic calibration, fracture detection, return-to-start |
| Instrument Type | Electromechanical universal testing machine |
| Brand | Hegewald & Peschke |
|---|---|
| Origin | Germany |
| Model | Inspekt Duo |
| Load Capacity | 5 kN / 10 kN |
| Frame Type | Dual-column, benchtop |
| Test Space Height | 1025 mm or 1325 mm |
| Test Space Width | 420 mm |
| Load Measurement Range | 0.4–100% of rated load |
| Compliance | EN 10002-2, ASTM E4, DIN EN ISO 7500-1 |
| Noise Level | ≤ 65 dB(A) |
| Drive System | Brushless motor, gearless transmission |
| Control Interface | Touch-enabled control panel and PC-based operation |
| Standard Functions | Overload protection, automatic calibration, fracture detection, auto-return |
| Software (optional) | LABMASTER |
| Brand | Hegewald & Peschke |
|---|---|
| Origin | Germany |
| Model | Inspekt Solo S / M / L |
| Max Load Capacity | 2.5 kN |
| Frame Type | Single-column |
| Crosshead Travel | 475 mm / 1075 mm / 1375 mm |
| Load Measurement Range | 0.2–100% of rated capacity (Class 1 accuracy, optional Class 0.5) |
| Load Cell Technology | Strain-gauge-based |
| Control Interface | USB 2.0 or LAN |
| Software | LABMASTER |
| Overload Protection | Yes |
| Automatic Sample Break Detection | Yes |
| Auto-return Function | Yes |
| Calibration | Automated |
| Weight | 48–60 kg (S–L variants) |
| Compliance Standards | ASTM E4, ASTM D638, ISO 527, ISO 178, DIN 53455, JIS K7113 |
| Brand | HEIDON (Shintō) |
|---|---|
| Origin | Japan |
| Model | TYPE38 |
| Drive Motor | AC Servo Motor |
| Drive Mechanism | Rack & Pinion |
| Traverse Speed | 5–6000 mm/min |
| Stroke Range | 1–100 mm |
| Motion Modes | Single-Stroke (auto-stop after preset distance) / Reciprocating (up to 99,999,999 cycles) |
| Load Measurement Range | 0–1000 gf |
| Load Cell Output | ±0.01% FS linearity (0 to ±5 V), Zero Drift: ≤0.01% FS/°C, Temperature Coefficient of Zero: ≤0.01% FS/°C |
| Low-Pass Filter | ~500 Hz |
| Overload Protection | Integrated safety circuit |
| EMI Suppression | High-frequency noise suppression circuit |
| Strain Amplifier | Manual and auto zero adjustment (±0.5 mV/V max) |
| Operating Environment | 0–50°C, ≤85% RH (non-condensing) |
| Power Supply | AC 100 V, 50/60 Hz |
| Dimensions (Main Unit) | W630 × D350 × H390 mm (H460 mm with pickup unit) |
| Standard Accessories | One load cell, one scratch stylus, one Φ10 mm ball indenter, one ASTM flat indenter, 2-m 3-pin power cord, acrylic safety cover, parts case, instruction manual, tool set |
| Brand | Heidon |
|---|---|
| Origin | Japan |
| Model | TYPE40 |
| Instrument Type | Reciprocating Tribometer |
| Compliance Standards | JIS K 5600, ASTM D 1894, JIS K 7125, JIS P 8147 |
| Load Cell Capacity | 9.807 N |
| Displacement Stage | Y-axis motorized |
| Measurement Principle | Orthogonal balanced-beam friction force sensing |
| Software | Integrated tribology analysis & control platform |
| Enclosure | Large reversible acrylic lid with sealing function |
| Optional Accessories | Pencil holder (sold separately), ASTM flat-ended indenter (standard) |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-500 |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −40 °C to 500 °C |
| Temperature Resolution | 1 K |
| Precision | ±0.1% |
| Single-Sample Test Duration | ~30 min |
| Heat Capacity | 10,500 J/K |
| Outer Bath Volume | ~20 L |
| Inner Bath Volume | 250 mL |
| Operating Modes | Adiabatic & Isothermal Calorimetry |
| Chamber Dimensions (Standard) | Φ35 × 35 cm or Φ50 × 50 cm |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-500 |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −80 °C to 500 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.01 K |
| Single-Sample Test Duration | Up to 1000 min |
| Heat Capacity | 60,000 J |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Adiabatic Control Method | Real-time Online PhiTEC Calibration |
| Sample Chamber Dimensions | Φ50 × 50 cm (standard), Φ35 × 35 cm (optional) |
| Pressure Rating | Up to 30 MPa |
| Data Channels | Expandable to 8 or 16 independent temperature inputs |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | HP Simular |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automated |
| Temperature Range | −30 °C to 210 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Heat Capacity Range | ±750 J/K |
| Maximum Pressure | 100 bar (upgradable to 200 bar) |
| Vessel Volume Options | 0.5 L, 1 L, 2 L |
| Vessel Materials | 316 Stainless Steel or Hastelloy C-276 |
| Stirring System | PTFE-coated shaft with 4-blade PTFE impeller (45–60° pitch) |
| Pressure Relief | Swagelok 316SS PRV + dial pressure gauge |
| Integrated Sensors | Temperature, pressure, optional in situ FTIR/Raman/turbidity/particle size |
| Calibration Heater | 150 W power-compensation heater |
| Control Software | HEL ChemScan™ with PAT integration, audit trail, and 21 CFR Part 11 compliance support |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | isoBTC-500 |
| Temperature Range | −60 °C to 100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 10,000 J/K |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Instrument Type | Accelerating Calorimeter |
| Measurement Mode | Isothermal Calorimetry |
| Compliance | Designed for GLP/GMP-aligned battery thermal safety testing |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | Phi-TEC I |
| Instrument Type | Adiabatic Accelerating Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −60 °C to 500 °C |
| Temperature Resolution | 0.005 K |
| Temperature Accuracy (direct sample mode) | ±0.01 °C |
| Temperature Stability (isothermal mode) | ±0.001 °C |
| Heat Capacity | ~10,000 J/K |
| Sample Mass Range | 0.5–80 g |
| Pressure Range | 0–300 bar (optional up to 1000 bar) |
| Pressure Accuracy | ±0.05% FS |
| Pressure Resolution | 0.01 bar |
| Exothermic Detection Sensitivity | 0.005–0.2 °C/min |
| φ-factor (low-φ cell) | ≤1.05 |
| Stirring | Electromagnetic, 0–500 rpm (mechanical stirrer optional) |
| Operating Modes | HWS (Heat-Wait-Search), RAMP, ISO |
| External/Inner Dewar Volume | 10 mL each |
| Single-Sample Test Duration | ~600 min |
| Dimensions | 30 cm × 37 cm × 50 cm |
| Power Supply | 220 V AC, 13 A |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Phi-TEC II |
| Price Range | USD 135,000–270,000 (FOB UK) |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −80 °C to 500 °C |
| Temperature Resolution | 0.001 K |
| Temperature Accuracy (Direct Sample Mode) | ±0.001 °C |
| Temperature Tracking Rate | Up to 400 °C/min (Low-Φ mode) |
| Standard | 50 °C/min |
| Pressure Range | 0–300 bar (optional up to 1000 bar) |
| Pressure Tracking Rate | 0–200 bar/min (optional 700 bar/min) |
| Pressure Accuracy | ±0.05% FS |
| Pressure Resolution | 0.01 bar |
| Heat Release Detection Sensitivity | 0.002–0.2 °C/min |
| Sample Mass Capacity | 0.5–80 g |
| Adiabatic Correction Factor (Φ) | ≤1.05 (optimized for Phi-TEC II) |
| Outer & Inner Dewar Volume | 60 mL each |
| Thermal Capacity | 60,000 J |
| Single-Test Duration | Up to 1000 min |
| Stirring | Electromagnetic, 0–500 rpm (mechanical option available) |
| Operating Modes | HWS (Heat-Wait-Search), RAMP, ISO (Isothermal) |
| Dimensions | 30 cm × 37 cm × 50 cm |
| Power Supply | 220 V AC, 13 A, single-phase |
| Brand | HEL (Hazard Evaluation Laboratories) |
|---|---|
| Origin | UK |
| Model | PhiTEC II |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Function | Micro-scale |
| Temperature Range | 0–500 °C |
| Temperature Detection Threshold | 0.02 °C/min |
| Adiabatic Temperature Tracking Rate | 200 °C/min |
| Maximum Calorimetric Chamber Pressure Rating | 137 bar |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | Simular 10L/20L |
| Calorimetry Mode | Adiabatic |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automated |
| Temperature Range | −30 °C to 225 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Maximum Jacket Pressure | 100 bar |
| Heat Capacity Range | ±750 J/K |
| Vessel Materials | Borosilicate Glass, 316 Stainless Steel, Hastelloy C-276 |
| Compatible PAT Interfaces | FTIR, Raman, pH, DO, ORP, Turbidity, Pressure, Temperature |
| Brand | HEL |
|---|---|
| Origin | UK |
| Model | SIMULAR |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal Calorimeter |
| Temperature Range | −80 to 350 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.1% |
| Single-Sample Test Duration | 300 min |
| Heat Capacity | 10,000 J |
| External Water Bath Volume | 1000 mL |
| Internal Water Bath Volume | 1000 mL |
| Brand | HEL |
|---|---|
| Origin | UK |
| Model | Simular |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automatic |
| Temperature Range | −30 °C to 225 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Heat Capacity Range | ±750 J/K |
| Reactor Volumes | 500 mL, 1 L, 2 L |
| Pressure Range | Vacuum to 100 bar (material-dependent) |
| Reactor Materials | Borosilicate Glass, 316 Stainless Steel, Hastelloy C-276 |
| Dual-Reactor Option | Yes |
| Sensor Integration | Temperature, Pressure, pH, Turbidity, In-situ FTIR, Raman, Particle Size Probes |
| Calorimetric Modes | Power Compensation (Calibration-Free), Heat Flow, Isothermal, Reflux, Iso-periodic |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | TSu |
| Instrument Type | Accelerating Rate Calorimeter (ARC®-style) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | –60 °C to 500 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | ~600 min |
| Heat Capacity | ~10,000 J/K |
| Outer Dewar Volume | ~10 mL |
| Inner Dewar Volume | ~10 mL |
| Sample Mass Range | 0.5–5 g |
| Pressure Range (standard) | 0–200 bar |
| Sample Cell | 8 mL spherical vessel (material options: borosilicate glass, stainless steel, Hastelloy®, custom alloys) |
| Brand | Hengpin (Jinan Hengpin Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP603 |
| Force Capacity | 500 N (optional load cells: 100 N, 200 N, 1000 N, 2000 N, 5000 N) |
| Resolution | 0.01 N |
| Accuracy | ±0.1 N |
| Test Mode | Fracture Strength Measurement |
| Speed Range | 1–500 mm/min (adjustable in real time) |
| Speed Accuracy | ±0.1 mm/s |
| Dimensions (W×D×H) | 540 × 280 × 1250 mm |
| Weight | ~55 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Hengpin (Ji’nan) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | HP612Q |
| Price Range | USD 1,400 – 2,800 |
| Force Range Options | 50 N / 100 N / 500 N / 1000 N |
| Resolution | 0.1 N |
| Accuracy | ±0.5% FS |
| Test Speed | 1–300 mm/min |
| Upper Platen | 10 mm diameter ultra-hard tungsten carbide indenter |
| Parallelism between Platens | < 0.025 mm |
| Lower Platen Diameter | 120 mm |
| Dimensions (W×D×H) | 430 × 350 × 710 mm |
| Weight | 45 kg |
| Power Supply | 220 V AC, 50 Hz |
| Standard Accessories | Main unit, microsphere compression fixtures, thermal mini-printer |
| Optional | Lenovo PC, inkjet printer, PC-based control & analysis software |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | BZY-1 / BZY-1N / BZY-1A |
| Measurement Range | 0–400 mN/m |
| Resolution | ±0.1 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Range | 0–400 °C |
| Temperature Display Accuracy | ±0.1 °C |
| Measurement Method | Wilhelmy Plate Method (optional Du Noüy Ring Method) |
| Compliance Standards | JB/T 9388-2002, GB/T 6541-1986, ISO 1409:1995, GB/T 22237-2008, GB 11278-1989, GB/T 18396-2001, SH/T 1156-1999 |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | BZY-2N/2A |
| Measurement Range | 0–200 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.02 mN/m |
| Temperature Display Range | 0–200 °C |
| Temperature Display Accuracy | ±0.02 °C |
| Measurement Method | Wilhelmy Plate Method (optional Du Noüy Ring Method) |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | BZY-3B / BZY-4B |
| Measurement Range | 0–400 mN/m |
| Resolution | 0.1 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Range | 0–400 °C |
| Temperature Display Accuracy | ±0.1 °C |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Compliance Standards | GB/T 6541-1986, GB/T 22237-2008, ISO 1409:1995, JB/T 9388-2002, SH/T 1156-1999, GB 11278-1989, GB/T 18396-2001 |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | High-Low Temperature Constant-Temperature Bath |
| Temperature Range | Typically –40 °C to +100 °C (configurable) |
| Temperature Stability | ±0.05 °C |
| Circulation Flow Rate | Up to 20 L/min |
| Bath Volume | 15–50 L (customizable) |
| Control Method | PID Auto-Tuning Digital Controller |
| Display | High-Brightness LED Numeric Display |
| Construction | Full 304 Stainless Steel |
| Cooling Method | Air-Cooled Compressor System |
| Heating Method | Immersed Electric Heater |
| External Circulation Interface | Dual Quick-Connect Fittings (Inlet/Outlet) |