Physical Property Testing Instruments
Filter
Showing 3391–3420 of 4355 results
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JJ2000B2 |
| Measurement Range (Interfacial Tension) | 1×10⁻⁶ mN/m to 100 mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | <2% (100 mN/m to 10⁻² mN/m), <8% (10⁻³ mN/m to 10⁻⁶ mN/m) |
| Rotational Speed Range | 2000–10,000 rpm |
| Speed Stability | ±0.1% |
| Temperature Control Range | Ambient to 95 °C |
| Capillary Inner Diameter | 2 mm / 4 mm |
| Contact Angle Range | 0–180° |
| Contact Angle Resolution | 0.01° |
| Image Magnification | 50–318 px/mm |
| Frame Rate | Up to 30 fps (continuous), programmable interval capture (1–3600 s) |
| Power Consumption | <50 W |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JJ2000C |
| Measurement Range | 10⁻⁶–100 mN/m |
| Temperature Control Range | 5–95 °C (PID) |
| Temperature Display Range | 0–99.9 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotational Speed | 1,000–10,000 rpm (±5 rpm) |
| Image Capture | USB-triggered monochrome camera, 60 fps |
| Spatial Resolution | 0.001 mm |
| Sample Tube ID | 2 mm & 4 mm high-purity quartz |
| Interface | USB or RS-232 |
| Data Export | Native Excel (.xlsx), BMP image archive |
| Compliance | ASTM D971, ISO 6295, USP <1042>, GLP-ready audit trail support |
| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JJ2000D1 |
| Measurement Range | 10⁻⁶–100 mN/m |
| Temperature Control Range | 5–95 °C (PID electric heating or external water bath) |
| Temperature Display Accuracy | ±0.1 °C |
| Rotational Speed | 1,000–10,000 rpm (±5 rpm control accuracy) |
| Imaging | USB-triggered CCD, 60 fps (optional 120 fps) |
| Spatial Resolution | 0.001 mm |
| Sample Tube ID | 2 mm & 4 mm high-purity quartz |
| Data Output | Excel-compatible database with time-, speed-, and temperature-stamped records |
| Compliance | Designed for GLP-compliant labs |
| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JJ2000H |
| Measurement Range | 100 to 10⁻⁶ mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Control Range | Ambient to 150 °C |
| Max Operating Pressure | 0.7 MPa |
| Motor Speed Range | 1,000–14,000 rpm |
| Speed Control Precision | ±5 rpm |
| Heating Method | Electric, Pt100 Sensor |
| Imaging | 752×480 CCD, 60 fps, LED-illuminated |
| Sample Tube ID | φ2 mm and φ4 mm quartz |
| Interface | RS232 or USB 2.0 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JJ2000H2 |
| Measurement Range | 100 to 1×10⁻⁶ mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | ±0.01 mN/m |
| Measurement Principle | Image-based spinning drop analysis — high-speed CCD captures droplet morphology under controlled centrifugal rotation |
| Temperature Control Range | Ambient to 150 °C |
| Pressure Rating | 0.7 MPa |
| Maximum Rotational Speed | 14,000 rpm |
| Speed Control Precision | ±5 rpm |
| Heating System | PID-controlled stainless-steel jacketed heater with Pt100 sensor |
| Imaging System | 60 fps monochrome CCD (752 × 480 pixels), motorized XYZ-stage with 0.01 mm resolution, 0.7–4.5× zoom lens |
| Sample Tube Options | φ2 mm and φ4 mm quartz capillaries |
| Interface | USB 2.0 or RS232 |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JK99 Series |
| Measurement Range | 0–500 mN/m (JK99F & JK99M: 0–1000 mN/m) |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sensor Type | Imported Japanese load cell (JK99B/C/D), METTLER high-precision balance sensor (JK99M) |
| Temperature Sensing Accuracy | ±0.1 °C |
| Power Supply | AC 220 V ±5 V, <150 W |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986 |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JK99B |
| Measurement Range | 0–500 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.05 mN/m |
| Temperature Display Accuracy | ±0.1 °C |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Power Supply | AC 220 V ±5%, <150 W |
| Interface | RS-232 Serial (requires external PC) |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JK99C |
| Measurement Range | 0–500 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.05 mN/m |
| Methods | Platinum Ring Method (Du Noüy) & Platinum Plate Method (Wilhelmy Plate) |
| Temperature Sensing Precision | ±0.1 °C |
| Power Supply | AC 220 V ±5%, <150 W |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986 |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JK99D1 |
| Measurement Range | 0–500 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Temperature Sensing Accuracy | ±0.1 °C |
| Power Supply | AC 220 ±5 V, <150 W |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986 |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JK99F |
| Measurement Range | 0–999.99 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Methods | Du Noüy Ring Method (40–50 mL sample volume) & Wilhelmy Plate Method (20–30 mL sample volume) |
| Sampling Cycle | 1–5 s (plate), 50–200 s (ring) |
| Z-axis Travel | 0–30 mm |
| Z-axis Precision | 1 µm |
| Power Supply | AC 220 ±5 V, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986, SY/T 5370–1999 |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JK99F2 |
| Measurement Range | 0–999.99 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.1 mN/m |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Temperature Sensing Accuracy | ±0.1 °C |
| Power Supply | AC 220 V ±5%, <150 W |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JK99M1 |
| Measurement Range | 0–999.999 mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | ±0.01 mN/m |
| Methods | Du Noüy Ring Method (40–50 mL sample volume) & Wilhelmy Plate Method (20–30 mL sample volume) |
| Sampling Interval | 1–5 s (Plate), 50–200 s (Ring) |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986, SY/T 5370–1999 |
| Sensor | High-precision 0.1 mg electromagnetic balance (METTLER-origin system) |
| Data Acquisition Rate | 10 Hz (standard), 50 Hz (optional) |
| Temperature Sensing Accuracy | ±0.1 °C |
| Platform Vertical Travel | 0–30 mm (standard), up to 100 mm (optional) |
| Positional Repeatability | ±0.1 mm (±1 µm with optional sensor) |
| Power Supply | AC 220 V ±5%, <150 W |
| Operating Humidity | 30–85% RH |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JMD04A |
| Instrument Type | Electromechanical Burst Tester |
| Maximum Burst Force | 50 kgf (490.3 N) |
| Displacement Resolution | 0.01 mm |
| Compliance | ASTM D3786, ISO 13938-1, GB/T 7742.1, BS EN ISO 13938-1 |
| Software | Windows-based control & analysis suite with real-time force-displacement curve acquisition, auto peak detection, statistical reporting (mean, SD, CV%), and export to CSV/PDF |
| [Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Electronic Burst Testing Machine |
| Maximum Burst Force | 1000 kgf (9.8 kN) |
| Displacement Resolution | ≤ 0.01 mm |
| Load Cell Accuracy | Class 0.5 per ISO 7500-1 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JMD04C |
| Maximum Burst Force | 5000 kgf (49.05 kN) |
| Test Speed Range | Adjustable |
| Stroke Range | Adjustable |
| Displacement Resolution | Not specified |
| Instrument Type | Electromechanical Burst Testing Machine |
| Compliance | Designed for ASTM D3787, ISO 13938-1, GB/T 7742.1, and related textile & membrane burst standards |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JML04C1 |
| Surface Tension Range | 0–150 mN/m |
| Resolution | < 0.05 mN/m |
| Measurement Method | Wilhelmy Plate Technique |
| Trough Material | PTFE (Full Fluoropolymer Construction) |
| Trough Dimensions | 200 mm × 80 mm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.05–3 mm/s |
| Vertical Deposition Speed | 0.02–2 mm/s |
| Deposition Modes | Upward & Downward |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | < 150 W |
| Operating Temperature | Ambient (with optional external thermostatic water bath, ≤65 °C) |
| Relative Humidity | 30–85% RH |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JML04C2 |
| Surface Tension Range | 0–150 mN/m |
| Resolution | < 0.05 mN/m |
| Measurement Method | Wilhelmy Plate |
| Trough Material | PTFE |
| Trough Dimensions | 300 mm × 100 mm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.05–3 mm/s |
| Vertical Deposition Speed | 0.02–2 mm/s |
| Operating Temperature | Ambient (with optional external thermostatic bath, ≤65 °C) |
| Power Supply | AC 220 V ±10%, 50 Hz, <150 W |
| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JMP2000A |
| Surface Tension Range | 0–150 mN/m |
| Resolution | < 0.05 mN/m |
| Measurement Method | Wilhelmy Plate |
| Langmuir Trough Dimensions (Upper Chamber) | 70 mm × 150 mm × 8 mm (W × L × H) |
| Max Measurable Area | 96.6 cm² |
| Min Measurable Area | 19.32 cm² |
| Oscillation Frequency Range (Sinusoidal Mode) | 0.001–1 Hz |
| Area Strain Amplitude | 1–6% (relative to equilibrium area) |
| Relaxation Step Change | 5–30% area change in 1–2 s |
| Sampling Interval | 150–300 s |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Power Consumption | <150 W |
| Operating Temperature | Ambient |
| Operating Humidity | 30–85% RH |
| Brand | POWEREACH (Shanghai Zhongchen Digital Technology Equipment Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | JN01A |
| Zeta Potential Measurement Principle | Mass-Exchange Electrophoresis |
| Sample Concentration Range | High-concentration dispersions (undiluted, slurry-state) |
| pH Range | Not specified |
| Compliance | Designed for ASTM D4187, ISO 13099-2, and GLP-compliant workflows requiring raw-state dispersion analysis |
| Interface | RS232 (COM port) + USB |
| Software | JN01.exe (Windows XP / 32-bit Windows 7 compatible) |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94 |
| Measurement Principle | Microelectrophoresis (Video-Based Particle Tracking) |
| Compliance | GB/T 32668–2016 (National Standard for Colloidal Particle Zeta Potential Analysis – Electrophoretic Method) |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Operating Temperature Range | Ambient to 35 °C |
| Zeta Potential Accuracy | Systematic error ≤5% |
| pH Range | 1.6–13.0 (typical operational range: 2.0–12.0) |
| Sample Volume per Test | 0.5 mL |
| Optical Magnification | Up to 1200× |
| Imaging System | USB Digital CCD with Customized Micrometer Grid Calibration |
| Electrode Configuration | Integrated Ag, Pt, and Ti/POM electrodes in open-cell electrophoresis chamber |
| Voltage Control | Adjustable DC bias with polarity reversal (0.30–1.20 s interval) |
| Temperature Compensation | Real-time thermistor-based ambient temperature sampling |
| Software Platform | Unified cross-model analysis suite with GLP-compliant data logging and audit trail capability |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94H-3H10X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 3 pixels/µm |
| System Accuracy | ±5% relative error (per GB/T 32668-2016 validation protocol) |
| Particle Size Applicability | 0.5–20 µm (aqueous dispersions) |
| Power Consumption | <150 W |
| Input Voltage | 220 V AC, 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94H2-3H10X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 3 pixel/µm |
| Particle Size Range | 0.5–20 µm |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Compliance | GB/T 32668–2016 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94J-1K20X |
| Zeta Potential Range | ±200 mV (typical, dependent on sample conductivity) |
| pH Range | 1.6–13.0 (optimal 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 12 pixel/μm |
| System Accuracy | ≤5% systematic error |
| Particle Size Applicability | 0.1–10 μm (aqueous dispersions) |
| Power Consumption | <150 W |
| Input Voltage | 220 V, 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JS94J2-1K20X |
| Zeta Potential Range | ±200 mV (typical, per GB/T 32668-2016 calibration protocol) |
| pH Range | 1.6–13.0 (standard operation: 2.0–12.0) |
| Operating Temperature | 20–35 °C |
| Temperature Resolution | 0.1 °C |
| Optical Resolution | 12 pixel/μm |
| Microscope System | WDK Japan high-magnification optical module, working distance 7 mm |
| System Accuracy | ≤5% relative error (per ISO 13099-2:2012 validation methodology) |
| Particle Size Applicability | 0.1–10 μm (aqueous & organic dispersions) |
| Power Consumption | <150 W, 220 V / 50 Hz |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94K-3H20X |
| Zeta Potential Range | ±200 mV (typical, inferred per ISO 13099-2) |
| pH Range | 1.6–13.0 (standard operation 2.0–12.0, resolution 0.1) |
| Temperature Range | Ambient to 35 °C (measurement resolution 0.1 °C) |
| Particle Size Compatibility | 0.2–50 µm (aqueous dispersions) |
| Optical Resolution | 1.93–12 pixels/µm (motorized zoom optical system) |
| Power Consumption | <150 W |
| Compliance | GB/T 32668–2016, ISO 13099-2:2012, ASTM D7825–14 |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JS94K2-3H20X |
| Zeta Potential Range | ±200 mV (typical, system-limited) |
| pH Range | 1.6–13.0 (standard operation 2.0–12.0, resolution 0.1) |
| Temperature Range | Ambient to 35 °C (readout resolution 0.1 °C) |
| Particle Size Compatibility | 0.2–50 µm |
| Optical Resolution | 1.93–12 pixels/µm (motorized zoom optical system) |
| Power Consumption | <150 W |
| Compliance | GB/T 32668–2016 (General Rules for Zeta Potential Analysis of Colloidal Particles by Electrophoresis) |
| System Accuracy | ±5% relative error (per certified reference dispersions under controlled conditions) |
| Sample Volume per Measurement | 0.5 mL |
| Voltage Polarity Switching Interval | 0.30–1.20 s (adjustable) |
| Measurement Time per Cycle | 3–10 s |
| Light Source | Low-power semiconductor blue/green LED (non-thermal, near-field illumination) |
| Brand | POWEREACH |
|---|---|
| Model | NDJ-1 |
| Type | Analog Rotational Viscometer |
| Portability | Benchtop (with integrated stand) |
| Operating Environment | Ambient temperature (10–35 °C) |
| Viscosity Range | 1–100,000 mPa·s |
| Rotors | Standard set includes #1–#4 |
| Speed Settings | 6, 12, 30, 60 rpm |
| Accuracy | ±5% for Newtonian fluids |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 1.5 kg |
| Dimensions (W×D×H) | 400 × 370 × 150 mm |
| Compliance | Designed per GB/T 2794–2013 (Chinese national standard for viscometer calibration), compatible with ISO 2555 and ASTM D2196 test methodologies |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-4 |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy | ±5% (for Newtonian fluids) |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 1.5 kg |
| Dimensions | 320 × 260 × 170 mm |
| Included Rotors | #1, #2, #3, #4 |
| Compliance | Designed for GLP-compliant routine viscosity monitoring in QC/QA and R&D environments |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-5S |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–100,000 mPa·s |
| Rotors | Standard #1–#4 |
| Speed Settings | 6, 12, 30, 60 rpm |
| Accuracy | ±2% for Newtonian liquids |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤80% |
| Dimensions | 370 × 325 × 280 mm |
| Net Weight | 6.8 kg |
| Compliance | Designed for GLP-compliant routine QC environments |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–1,000,000 mPa·s |
| Rotational Speeds | 7.5 / 75 / 750 rpm |
| Accuracy | ±4% (for Newtonian fluids) |
| Dimensions (L×W×H) | 170 × 140 × 440 mm |
| Weight | 14 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Compliance | Designed for routine QC and R&D in industrial and academic labs per ISO 2555 and ASTM D2196 principles |