Physical Property Testing Instruments
Filter
Showing 3541–3570 of 4355 results
| Brand | Aipei Technology (APKJ) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP-RCA |
| Pricing | Upon Request |
| Load Options | 55 g, 175 g, 275 g |
| Dimensions (W×D×H) | 830 × 490 × 340 mm |
| Weight | ~15 kg |
| Power Supply | AC 220 V, 50/60 Hz |
| Rated Power | 500 W |
| Counter Range | 0–999,999 cycles (LCD digital preset counter) |
| Included Accessories | Elevating platform (1), LED-lit magnifier (1), 55 g weight (1), 175 g weight (1), hex key set (1), O-rings (5), dovetail clamps (2), circular level (1), Norman PCA abrasive paper rolls (2) |
| Brand | Haytham |
|---|---|
| Model | Red Box SH |
| Origin | Guangdong, China |
| Deformation Measurement Range | 0–1000% |
| Linearity | ±0.5% |
| Application Temperature Range | Up to 2200 °C (dependent on optical configuration and furnace integration) |
| Measurement Principle | Stereo Digital Image Correlation (DIC) with High-Speed CMOS Imaging and Real-Time 3D Displacement Reconstruction |
| Brand | Red Sun Instrument |
|---|---|
| Model | HRQS-37A |
| Measurement Principle | Schering Bridge (High-Voltage AC Null Detection) |
| Frequency | 50 Hz / 60 Hz (Power Frequency), Optional 100 Hz–10 kHz Range |
| Test Voltage | Up to 2.5 kV AC (RMS), Adjustable |
| Capacitance Range | 1 pF – 25 µF |
| Dissipation Factor (tan δ) Range | 0 – 1 |
| tan δ Accuracy | ±1.5% of reading ±0.0001 |
| Relative Permittivity (εᵣ) Resolution | 0.01 |
| εᵣ Accuracy | Derived from Cₓ/Cₙ with calibrated standard capacitor (Cₙ = 100 pF) |
| Temperature Control | Dual-zone PID-controlled heating (inner/outer chambers), simultaneous internal/external temperature monitoring |
| Compliance | ASTM D150-11, GB/T 1409-2006, GB/T 1693-2007, GB/T 5594.4-2015 |
| Data Output | Analog voltage signals + RS232 interface |
| Operating Environment | 20 ± 5 °C, 30–80% RH |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRJC-2000V |
| Maximum Output Voltage | AC/DC 0–50 kV |
| Rated Power Capacity | 3 kVA |
| Voltage Ramp Rate | 0.1–5 kV/s (adjustable) |
| Test Modes | AC/DC Uniform Ramp, Stepwise Ramp, and Withstand Testing |
| Compliance Standards | GB/T 1695-2005, GB/T 4109-2008, DL 418-91, ASTM D149, IEC 60243-1 |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | M-200 |
| Instrument Type | Multi-Function Tribological Tester |
| Maximum Friction Force | 20 N |
| Friction Force Resolution | 0.4 mN |
| Maximum Operating Temperature | 45 °C |
| Maximum Test Load | 2000 N |
| Load Accuracy (≥10% FS) | ±2% |
| Load Repeatability (≥10% FS) | ≤2% |
| Friction Torque Range | 0–15 N·m |
| Torque Accuracy (≥10% FS) | ±3% |
| Torque Repeatability (≥10% FS) | ≤3% |
| Lower Specimen Shaft Speed | 200–400 rpm (stepless) |
| Upper Specimen Shaft Speed | 180/360 rpm |
| Axial Travel of Upper Specimen | ±4 mm |
| Time Control Range | 1 s – 9999 min |
| Revolution Count Range | 1 – 999999 |
| Specimen Dimensions | 30 mm × 7 mm × 6 mm |
| Counterface Ring | Ø40 × 10 mm, hardened 45# steel (HRC 40–45), surface roughness Ra ≤ 0.8 µm, concentricity < 0.01 mm |
| Normal Load Options | 196 N (±0.1%), extendable to 392 N |
| Standard Weights | One 4 kg + four 1 kg calibrated masses |
| Water Bath Integration | Yes |
| Power Supply | 120/230 V, 50/60 Hz, 2 A / 1 A |
| Dimensions (L×W×H) | 330 × 500 × 460 mm |
| Weight | 33 kg |
| Compliance Standards | ASTM D3514, D3885, D3886 |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 040101 |
| Price | Upon Request |
| Load Capacity | 0–5,000 N |
| Force Resolution | 0.5 N |
| Sensor Accuracy | ±0.1% of full scale |
| Measurement Range | 10–5,000 N |
| Test Speed | 3–125 mm/min (electronically controlled, programmable) |
| Test Plate Dimensions | 150 × 150 mm (L × W) |
| Maximum Travel Height | 140 mm |
| Plate Parallelism | ≤1/1000 mm (axial), <0.05 mm (lateral) |
| Return Speed | 125 mm/min |
| Drive System | DC servo motor with low-friction dual-column guidance |
| Overload Protection | Dual fixed + dual movable limit switches |
| Leveling | Four adjustable anti-vibration feet |
| Interface | RS-232 serial port |
| Compatible Software | REGISTRA III |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W×D×H) | 300 × 460 × 720 mm |
| Net Weight | 65 kg |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | DMC-196 |
| Measurement Mode | Isothermal Microcalorimetry |
| Instrument Type | Calvet-type Heat Flow Calorimeter |
| Key Features | Ultra-low temperature capability, high-sensitivity 3D thermopile sensor, dual-mode (DSC & IMC), high-pressure compatibility up to 350 bar |
| Temperature Range | −196 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.1 µW (heat flow) |
| Temperature Scan Rate | 0.001–1 °C/min |
| Single-sample Test Duration | ~15 min |
| Calorimetric Cell Max Pressure Rating | 350 bar |
| Heat Capacity (typical) | ~10,500 J/K |
| Pressure Resolution | 0.1 µW (equivalent heat flow resolution under pressure coupling) |
| Outer Dewar Volume | Up to 12.5 mL |
| Inner Sample Cell Volume | Up to 12.5 mL |
| Peak-to-Peak Noise Level | 1 µW |
| Calorimetric Accuracy | ±0.1% |
| Calorimetric Precision | ±0.2% |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Calvet-type Microcalorimeter |
| Measurement Modes | Isothermal Microcalorimetry (IMC) & Differential Scanning Calorimetry (DSC) |
| Sample Capacity | Up to 12.5 mL |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy & Precision | ±0.1 °C |
| Temperature Scan Rate | 0.001–2 °C/min |
| Heat Flow Resolution | 0.1 μW |
| Baseline Noise (Peak-to-Peak) | ≤1 μW |
| Calorimetric Accuracy | ±0.2% |
| Calorimetric Precision | ±0.2% |
| Maximum Pressure Rating (High-Pressure Cell) | 100 MPa (1,000 bar) |
| Pressure Resolution | 350 bar (for integrated pressure tracking cells) |
| External Bath Volume | Up to 12.5 mL |
| Internal Bath Volume | 12.5 mL |
| Dimensions | 29 cm × 29 cm × 63 cm |
| Weight | 25 kg |
| Power Supply | 110–240 V, 50/60 Hz |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSC-790 |
| Sample Capacity | Single |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −150 °C to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| DSC Heat Flow Range | ±6000 mW |
| Cooling Options | Liquid Nitrogen, Mechanical, or Ambient Air |
| Heating Rate | 0.01–100 °C/min |
| Heat Flow Resolution | 0.1 µW |
| Calorimetric Accuracy | ±0.1% |
| Calorimetric Precision | ±0.1% |
| Atmosphere Control | Dual-gas inlet with software-driven automatic switching |
| Dimensions (W×D×H) | 950 mm × 555 mm × 360 mm |
| Weight | 30 kg |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Isothermal Microcalorimeter |
| Instrument Category | Cone Calorimeter (Note: *This is a misclassification in source data |
| Model | MIC-90 |
| Measurement Mode | Isothermal |
| Temperature Range | 3 °C to 95 °C |
| Temperature Stability | ±0.001 °C |
| Temperature Precision | ±0.15 °C |
| Single-Sample Measurement Time | ~15 min |
| Heat Capacity (System) | ~10,500 J/K |
| Outer Bath Volume | 25 mL |
| Inner Bath Volume | 25 mL |
| Channel Configurations | 3-channel or 8-channel swappable modules |
| Detection Limit | 2 μW (8-ch), 8 μW (3-ch) |
| Short-Term Noise | <1 μW (8-ch), <8 μW (3-ch) |
| Baseline Drift (24 h) | <5 μW (8-ch), <55 μW (3-ch) |
| Measurement Range | ±900 mW |
| Sample Cell Volume Options | 25 mL or 100 mL |
| Cell Materials | Borosilicate glass, stainless steel, or custom polymer |
| In-situ Mixing | Motorized stirrer with adjustable speed |
| Thermal Sensing Principle | Differential Seebeck-effect planar thermopile sensors |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Reaction Calorimeter |
| Automation Level | Fully Automated |
| Temperature Range (Reactor) | –25 °C to 200 °C |
| Temperature Range (Oil Bath) | –45 °C to 250 °C |
| Temperature Resolution | 1.0 mK |
| Temperature Control Precision | ±0.1 K |
| Calorimetric Methods | Heat-Flow, Power Compensation (optional), Reflux (optional) |
| Reactor Volume | 1000 mL (customizable) |
| Maximum Operating Pressure | 10 MPa |
| Stirring Speed | up to 2000 rpm |
| Torque | up to 75 N·cm |
| Oil Circulation Rate | 35–76 L/min |
| Calibration Heater | 0–50 VDC / 3.00 A / 120 W |
| Power Supply | 3×400 V / 50 Hz (±10%) / 20 A |
| Total System Power | 7000 W |
| Oil Bath Dimensions | 600 × 700 × 1300 mm |
| Oil Bath Weight | 210 kg |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Manufacturer |
| Model | STA-790 |
| Temperature Range | Ambient to 1300 °C / 1600 °C |
| Heating Rate | 0.01–50 °C/min |
| Thermogravimetric (TGA) Range | ±200 mg / ±1000 mg |
| TGA Resolution | 0.02 µg |
| DSC Resolution | 1 µW |
| Atmosphere Control | Dual independent mass-flow-controlled gas lines with software-programmable switching |
| Crucible Options | Al₂O₃, quartz, BN (optional) |
| Furnace Cooling | Integrated water-cooled furnace housing |
| Power Supply | 220 V, 50/60 Hz |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TGA-790 |
| Pricing | Upon Request |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | Room Temperature to 700 °C |
| Balance Sensitivity | ±0.01 µg |
| Temperature Calibration Method | Curie Point Reference |
| Heating/Cooling Rate | 0.01–50 °C/min |
| Mass Range | ±200 mg |
| Mass Resolution | ±0.02 µg |
| Atmosphere Control | Dual Independent Mass Flow Controllers (MFCs), Software-Programmable Gas Switching |
| Crucible Options | Alumina, Platinum |
| Furnace Cooling | Water-Cooled |
| Furnace Liner | Dust-Free Recirculating Cooling System |
| Power Supply | 220 V, 50/60 Hz |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | RS-WD |
| Instrument Type | Temperature Transmitter |
| Output Options | 4–20 mA / 0–5 V / 0–10 V |
| Supply Voltage | 10–30 V DC |
| Default Temperature Accuracy | ±0.5 °C @ 25 °C |
| Extended Range Accuracy | ±1.0 °C @ 25 °C |
| Transmitter Operating Temp. | −20 to +60 °C |
| Probe Operating Temp. | −40 to +80 °C (standard) |
| Probe Humidity Range | 0–100 %RH |
| Response Time (1 m/s airflow) | ≤10 s |
| Load Capacity | ≤600 Ω (current output), ≤250 Ω (voltage output) |
| Mounting Cutout | 60 mm² |
| Display | Integrated LCD |
| Brand | RESUNTECH |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NanoCoulter G |
| Price Range | USD 84,000–112,000 (FOB) |
| Size Range | 60–2000 nm |
| Size Reproducibility | >90% |
| Temperature Range | 5–40 °C |
| Temperature Control Accuracy | ±5 °C |
| Detection Principle | Resistive Pulse Sensing (RPS) |
| Sample Volume | 30–50 µL |
| Particle Concentration Range | 1×10⁶–1×10¹² particles/mL |
| Zeta Potential Range | −200 to +200 mV |
| Measurement Time | 5–10 min |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail Enabled |
| Dimensions | 27 × 16.5 × 19 cm |
| Weight | 8 kg |
| Brand | Revealer |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RDIC-3D |
| Pricing | Available Upon Request |
| Camera Resolution | 20 MP (per camera) |
| Configuration | Dual high-resolution cameras, hardware synchronization controller, calibration target, proprietary DIC software suite, dedicated graphics workstation |
| Measurement Capability | Full-field 3D coordinates, quasi-static displacement, and strain tensors (εₓₓ, εᵧᵧ, ε_zz, γₓᵧ, γ_yz, γ_zx) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RH-200 Relative Humidity Generator |
| Price | Upon Request |
| RH Range | 3–95% RH |
| RH Control Accuracy | ±1.0% RH |
| Temperature Control Range | Ambient to 50 °C |
| Dew Point Range | −25 °C to 50 °C |
| Standard Flow Rate | 500 mL/min (Optional High-Flow: up to 5 L/min) |
| Brand | RheoSense |
|---|---|
| Origin | USA |
| Model | Initium |
| Instrument Type | Portable Microfluidic Viscometer |
| Viscosity Range | 0.2–2000 cP |
| Temperature Range | 4–70 °C |
| Sample Volume per Measurement | <5 µL |
| Shear Rate Range | Up to 10⁶ s⁻¹ |
| Compliance | ASTM D2196, ISO 2555, USP <911> |
| Brand | RHEOTECH |
|---|---|
| Origin | Japan |
| Model | FUDOH RTC-3002D |
| Load Capacity | ±200 N |
| Stroke Range | 0.1–99.9 mm (0.1 mm resolution) |
| Test Speed Options | 2, 5, 6, 10, 20, 30 cm/min or 5, 6, 10, 20, 30, 60 cm/min |
| Display | Triple 3-digit LED (force, displacement, time) |
| Auto-zero Function | Yes |
| Power Supply | 220–250 V AC, 50/60 Hz |
| Dimensions | 260 W × 430 H × 280 D mm |
| Weight | 15 kg |
| Compliance | Designed for ISO 11357, ASTM F3165, USP <1043>, and GLP-compliant texture analysis workflows |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | DSC-XRD |
| Configuration | θ–θ goniometer geometry |
| Coupling Type | Synchronized in-situ DSC–XRD |
| Atmosphere Control | Programmable gas environment (N₂, Ar, air, O₂) |
| Temperature Range | RT to 1200 °C (DSC sensor dependent) |
| X-ray Source | Cu Kα (standard), optional Mo or Co anodes |
| Detector | High-speed 1D/2D pixel array detector (e.g., HyPix-400) |
| Data Synchronization | Sub-second temporal alignment of thermal and diffraction signals |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | DSC |
| Temperature Range | Ambient to 1500 °C |
| Manufacturer Status | Authorized Distributor (Non-OEM) |
| Origin Category | Imported Instrument |
| Model | DSC8271 |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | DSC |
| Temperature Range | −170 °C to 725 °C |
| Configuration | Imported System |
| Distribution Model | Authorized Distributor |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TG-DTA8122 |
| Temperature Range | Ambient to 1500 °C |
| Measurement Principle | Horizontal Dual-Cantilever Differential DTA with Integrated Thermogravimetry (TG) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | Thermo Mass |
| Coupling Type | TGA-MS |
| Mass Range | up to m/z 400 |
| Ionization Method | Fragment-Free Photoionization |
| Interface Technology | Patented Skimmer Interface |
| Real-Time Synchronization | Quadruple Concurrent Measurement (TGA, DTG, MS Total Ion Current, Selected Ion Monitoring) |
| Compliance | Designed for ISO 11358, ASTM E1131, and USP <621> thermal analysis workflows |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TMA8311 |
| Maximum Measurement Temperature | 1500 °C |
| Measurement Principle | Dual-rod Differential Dilatometry |
| Instrument Type | Thermomechanical Analyzer (TMA) |
| Brand | RION |
|---|---|
| Origin | Japan |
| Model | KE40B |
| Measurement Principle | Laser Light Scattering (830 nm Diode Laser, Class 1 per IEC 60825-1) |
| Detection Range | 0.15–0.5 µm (factory-configured 4-channel: 0.15 / 0.2 / 0.3 / 0.5 µm |
| Detection Efficiency | 50 ± 10% at 0.15 µm |
| Sample Flow Rate | 10 mL/min |
| Maximum Particle Concentration | 1,200 particles/mL (±5% accuracy for 0.15 µm particles) |
| Sample Pressure Limit | ≤300 kPa (gauge) |
| Wetted Materials | Quartz, PFA |
| Calibration Standard | PSL spheres (1.6 µm nominal) |
| Display Interface | Integrated resistive touch screen |
| Data Output | Built-in thermal printer + SD memory card storage |
| Communication | Direct interface with KE-40B1 controller (no external PC required) |
| Power Supply | DC 12 V (supplied by KE-40B1) |
| Operating Environment | 15–30 °C, ≤85% RH (non-condensing) |
| Dimensions (H×W×D) | 160 × 300 × 251 mm (excl. protrusions) |
| Weight | ~7.5 kg |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Corporation |
| Type | Oil-Free Positive Displacement Compressor |
| Model | C3-9290-02 |
| Air Flow Rate | 25 L/min (at 50 Hz) |
| Power Supply | AC 100 V, 50/60 Hz |
| Noise Level | ≤52 dB(A) |
| Operating Pressure | Up to 0.8 MPa (8 bar) |
| Filtration | Integrated HEPA-grade inlet filter |
| Duty Cycle | Continuous operation rated |
| Certifications | CE, RoHS, JIS B 8330 compliant |
| Brand | ROOKO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FT-803 Series |
| Measurement Range | 0–20 kN (customizable) |
| Accuracy | ≤0.5% F.S. |
| Units | kgf, N, lbf (switchable) |
| Output | crushing strength (average, max/min), specific strength (per unit length/area), compression deformation (elastic), statistical analysis (upper/lower limits, tolerance band, % distribution) |
| Compliance | GB/T 44750, ASTM D6176, ASTM D4179, ISO 4708 |
| Interface | USB & RS-232 |
| Software | PC-based with data logging, report generation, real-time curve plotting, and process analytics |
| Language | bilingual (English/Chinese) |
| Safety | integrated mechanical and software interlocks |
| Brand | Custom OEM |
|---|---|
| Model | LXJ-Series |
| Type | Rotary-Arm Centrifugal Acceleration Testing System |
| [Capacity Options | 3–20 kg |
| Max Acceleration Range | 30–400,000 m/s² (≈3–40,800 g) |
| Test Axes | X, Y, Z orthogonal directions |
| Specimen Mounting Radius | 100–500 mm |
| Max Specimen Height | 200–300 mm |
| Workstations | 4–10 independent positions |
| Start Time | ≤3–5 min |
| Continuous Operation | 5–60 min |
| Power Supply | AC 380 V, 1.5–6.5 kVA |
| Slip Ring | 15-channel, 500 V / 5 A |
| Compliance | MIL-STD-810F, MIL-STD-202F, MIL-STD-883C, GJB150A, GJB360B, GB/T 2423, IEC 60068-2-27] |
| Brand | Custom OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 28,000 (FOB) |
| [Key | Value] |
| Acceleration Range | 30–200,000 g (selectable by model) |
| Sample Mounting Radius | 200–1000 mm |
| Max Payload Capacity | 5–200 kg (model-dependent) |
| Sample Height Limit | 200–300 mm |
| Test Axes | X, Y, Z orthogonal directions (sequential or independent) |
| Control System | Industrial PC with real-time PID loop |
| Power Supply | AC 380 V, 1.5–6.5 kVA |
| Continuous Run Time | 30–60 min (thermal-limited) |
| Compliance Standards | MIL-STD-810F, MIL-STD-883C, MIL-STD-202F, GJB 150A, GJB 360B, GB/T 2423.15, IEC 60068-2-27 |
| Safety Protections | Over-speed cutoff, over-acceleration limit, open-circuit detection, thermal shutdown |
| Slip Ring Configuration | Up to 15 channels, 500 V / 5 A per channel |
| Dimensions (L×W×H) | 924×910×1242 mm to 1953×470×993 mm (model-specific) |
| Weight | 1000–2300 kg |