Physical Property Testing Instruments
Filter
Showing 3901–3930 of 4355 results
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Temperature Range | −70 °C to +180 °C |
| Test Compartment Volume | Standard 100 L |
| Compliance | IEC 60068-2-14, MIL-STD-202G Method 107, JIS Z 8704, GB/T 2423.22 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Compliance | IEC 60068-2-14, MIL-STD-810G Method 503.5, GB/T 2423.22-2002, GJB 150.5A-2009, ISO 16750-4, QC/T 17-2021 |
| Control System | 10.4" Color TFT LCD Touchscreen Controller with PID Algorithm |
| Test Port | Ø50 mm Left-Side Penetration Port |
| Temperature Recovery Time | ≤5 min (per ASTM E1545-02 reference conditions) |
| Cycle Switching Time | ≤10 s (air flap actuation) |
| Programmable Cycles | 1–999 |
| Soak Time Range | 1–999 min per zone |
| Defrost Mode | Auto/Manual, Configurable Frequency |
| Refrigerant | R507A/R23 (Zero ODP, Low GWP HFC blend) |
| Construction | Interior & Exterior SUS304 Stainless Steel |
| Safety Protections | Overtemperature, overcurrent, ground fault, compressor high-pressure/low-pressure, phase failure, emergency stop, door interlock |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Display | 7″ TFT True-Color LCD Touchscreen Controller |
| Door Viewport | Multi-Layer Tempered Glass with Conductive Film Defrosting & Internal LED Illumination |
| Air Circulation | Low-Noise High-Efficiency AC Motor with Multi-Blade Centrifugal Impeller |
| Mobility | Lockable PU Casters |
| Test Port | One Φ50 mm Access Port (Left Side, Sealed Gland) |
| Safety Systems | Over-Temperature Protection, Compressor Overload/High-Pressure Cutout, Leakage Current Detection, Water Shortage Alarm, Real-Time Fault Logging & Auto Shutdown |
| Refrigeration Architecture | Modular Hermetic Compressor Units |
| Evaporator Integrity | Water-Immersion Leak Testing Certified |
| Airflow Design | Positive-Pressure Uniformity Optimized Duct System |
| Defrost Method | Adaptive Scheduled Defrost with Reduced Cycle Duration |
| Control Algorithm | Proprietary Fuzzy Logic Thermal Load Compensation Engine |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Control System | Touchscreen PID Controller |
| Refrigeration | Dual-Stage Cascade System with Bitzer or Tecumseh Compressors |
| Temperature Range | -65°C to +180°C |
| Transition Time (Typical) | ≤30 s between chambers |
| Internal Volume | Standard 100 L / 200 L / 400 L configurations |
| Uniformity | ±0.5°C (at steady state) |
| Compliance | IEC 60068-2-14, MIL-STD-810H Method 503.5, JIS Z 8702 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Temperature Range | -70°C to +180°C |
| Transition Time (Typ.) | ≤15 s (5℃ to -40℃ or +100℃ to -10℃, test zone) |
| Control System | TEMI880 Programmable Touchscreen Controller (Korean Origin) |
| Compliance Standards | GB 10589, GB 11158, GB 10586, IEC 60068-2-14, MIL-STD-810H Method 503.5 |
| Key Features | Three-zone design (high-temp chamber, low-temp chamber, test chamber) |
|---|---|
| Inner chamber wall thickness | 1.0–1.2 mm standard |
| Standard internal volumes | 50 L to 1000 L |
| Typical temperature ranges | −40 °C to +150 °C, −55 °C to +150 °C, or −70 °C to +150 °C |
| Key | Temperature Range (High Zone): +150°C to +200°C |
|---|---|
| Temperature Range (Low Zone) | -70°C to -40°C |
| Transition Time (Typical) | ≤15 s (5℃ to -40℃) |
| Test Zone Stability | ±0.5°C |
| Control System | PLC-based with 302×240-dot LCD HMI (Bilingual English/Chinese) |
| Program Storage | 100 user-defined profiles, up to 9999 cycles per profile |
| Timing Resolution | 1 min (adjustable to 1 sec) |
| Communication Interface | RS-232C, optional RS-485/Ethernet |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–1989, GJB 150.5–1986, GJB 360.7–1987, IEC 60068-2-14 (Test N) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Construction | Triple-Chamber Static-Position Design |
| Temperature Range | −65°C to +180°C |
| Transition Time (HT→LT) | ≤15 s (typical, 50 mm sample zone) |
| Internal Volume | 150 L standard |
| Control System | IPC2000 Color LCD Touchscreen with Real-Time Curve Display |
| Insulation | Rigid Polyurethane Foam + Ultra-Fine Glass Wool |
| Refrigeration | Dual-Stage Cascade System with Two Tecumseh (France) Semi-Hermetic Compressors |
| Condenser | Water-Cooled |
| Heating | Stainless Steel Finned Heaters |
| Sealing | High-Performance Silicone Rubber Gaskets |
| Compliance | Designed per IEC 60068-2-14, MIL-STD-810H Method 503.5, JIS Z 8702 |
| [Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Transition Time | ≤10 s |
| Temperature Recovery Time | ≤5 min |
| Compliance | IEC 60068-2-14, JIS C 60068-2-14, MIL-STD-810H Method 503.5, GJB 150.5A-2009 |
| Control System | 320×240-dot Color LCD Touchscreen Controller (Bilingual English/Chinese), Programmable Logic Controller (PLC) Integration |
| Safety Features | Overtemperature, Overpressure, Phase Imbalance, Low Refrigerant Flow, Compressor Oil Pressure Loss, Cooling Water Failure, Leakage Protection |
| Interface | RS-232C Serial Communication Port |
| Data Logging | Optional Integrated Temperature Recorder |
| Optional Upgrade | LN₂-Assisted Rapid Cooling System |
| Internal Construction | Stainless Steel 304 Chamber Liner |
| Chamber Configuration | Three-Separate-Zone (High-Temp / Low-Temp / Test) with Thermal Isolation Structure] |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Key Temperature Range Options | A: -20°C to 200°C |
|---|---|
| B | -40°C to 200°C |
| C | -60°C to 200°C |
| Temperature Stability | ≤ ±2°C in High/Low Temp Zones |
| Thermal Transition Performance | -40°C ↔ 85°C in ≤ 11 min (including dwell) |
| Heat Storage Zone Ramp | Ambient to +100°C in ~30 min |
| Cold Storage Zone Ramp | Ambient to -50°C in ~90 min |
| Test Zone Dimensions | 450 mm (W) × 300 mm (H) × 300 mm (D) |
| Test Load Capacity | 20 kg / 30 kg / 50 kg options |
| Construction | Interior & Exterior Panels – SUS#304 Stainless Steel |
| Insulation | High-Density Fire-Retardant PU Foam + Advanced K-Type Sweat-Prevention Ducting |
| Cooling System | Dual-Stage Cryogenic Refrigeration with Eco-Friendly Refrigerant (R-404A/R-23 blend), Plate-Type Heat Exchangers, Automatic/Manual Defrost Circuits |
| Control System | 7-inch Full-Color LCD Touchscreen Microprocessor Controller with RS-232/RS-485 Interface |
| Compliance | Designed to meet IEC 60068-2-14, MIL-STD-810H Method 503.5, JIS C 0025, CNS 12227, and ISO 16750-4 environmental stress screening requirements |
| Safety Protections | Independent Over-Temperature Cutout (Test Chamber), Compressor High-Pressure & Low-Oil-Pressure Protection, Heating Element Overload/Short-Circuit Protection, Phase Failure & Undervoltage Detection, Ground Fault Monitoring |
| Key | Internal Chamber Dimensions: 46×46×46 cm |
|---|---|
| High-Temperature Zone Range | Ambient to +150 °C |
| Low-Temperature Zone Range | Ambient to −60 °C |
| Average Ramp Rate | 1.5 °C/min |
| Temperature Uniformity | ±0.5 °C |
| Temperature Accuracy | ±2 °C |
| Transfer Time (Cold ↔ Hot) | <10 s |
| Temperature Recovery Time | <5 min |
| Actuation Method | Pneumatic Cylinder-Based Basket/Tray Transfer |
| Construction | Exterior & Interior Liner — SUS304 Stainless Steel |
| Refrigeration System | Dual-Stage Compound Compressor (Air-Cooled or Water-Cooled), Imported Tecumseh (France) Compressor Units, Eco-Friendly Refrigerant (R404A/R507) |
| Control System | Programmable LCD Controller (320 × 240 Dots), Bilingual (English/Chinese) Interface |
| Max. Program Storage | 100 Sets |
| Max. Cycles per Program | 9999 |
| Max. Segment Duration | 999 h 59 min |
| Communication | RS-232C Port for PC Integration, Data Logging & Remote Editing |
| Dynamic I/O | Two Time-Signal Relays |
| Power Rating | 7.5 kW / 12 kW / 15 kW / 26 kW |
| Electrical Supply | AC 380 V, 50 Hz, 3-Phase 4-Wire |
| Compliance | GB/T 2423.22, GJB 150.5A, IEC 60068-2-14, MIL-STD-810H Method 503.5 |
| Application Scope | Static (non-moving) specimen testing only |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70°C to +200°C |
| Preheat Upper Limit | +200°C |
| Precool Lower Limit | −70°C |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C (Steady State), ≤ ±2°C (Cycling) |
| Ramp Rate (RT → +200°C) | ~40 min |
| Ramp Rate (RT → −70°C) | ~60 min |
| Transfer Time Between Chambers | ≤ 5 s |
| Chamber Configurations | Dual-Chamber or Triple-Chamber |
| Control Interface | Touchscreen Color LCD with PID Auto-Tuning |
| Cycle Programmability | Start Mode Selection (Hot/Cold First), Cycle Count Setting, Auto-Defrost, Scheduled Start |
| Compliance Support | Designed for ASTM D5229, ISO 11359-2, IEC 60068-2-14, MIL-STD-810H Method 503.7 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +150 °C |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Range | 30–98% RH |
| Humidity Deviation | +2 / −3% RH |
| Avg. Ramp Rate | 0.7–1.0 °C/min |
| Time Setting Range | 0–9999 h |
| Power Supply | AC 380 V |
| Internal Dimensions (W×D×H, mm) | 400×500×400 (OK-TS-100) to 1000×1000×1000 (OK-TS-1000) |
| External Dimensions (W×D×H, mm) | 1200×1650×1100 (OK-TS-100) to 1900×2100×1850 (OK-TS-1000) |
| Observation Window | Ø50 mm test port & illuminated tempered glass viewport |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | RT to −70 °C |
| Test Zone Range | +60 °C to +150 °C (Hot Shock), 0 °C to −65 °C (Cold Shock) |
| Switching Mechanism | Pneumatic Air-Damper–Actuated Static Specimen Method |
| Recovery Time | <5 min |
| Temperature Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration | Dual-Stage Cascade System with R404A/R23 Refrigerants |
| Construction | Interior – Mirror-Finish SUS304 Stainless Steel |
| Insulation | High-Density Fire-Retardant PU Foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Key | Brand: OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | RT to −70 °C |
| Test Zone Range | +60 °C to +150 °C (hot shock) |
| Temperature Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration | Dual-stage cascade system with R404A/R23 refrigerants |
| Construction | Interior – SUS#304 mirror-finish stainless steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Brand | OK |
|---|---|
| Model Range | OK-TS-50 to OK-TS-1000 |
| Chamber Type | Dual-Zone or Tri-Zone Thermal Shock Test Chamber |
| Temperature Range (Test Zone) | -70 °C to +150 °C (configurable by model) |
| High-Temp Zone Range | 60 °C to 150 °C |
| Low-Temp Zone Range | -20 °C to -70 °C (selectable) |
| Temp. Fluctuation | ≤ ±0.5 °C |
| Temp. Uniformity | ≤ ±2 °C (high/low zones) |
| Temp. Recovery Time | ≤ 5 min |
| Transfer Time (specimen movement) | ≤ 10 s |
| Heating System | SSR-controlled U-shaped finned stainless-steel heaters |
| Cooling System | Twin-stage cascade refrigeration with Tecumseh/Tecumseh-derived hermetic compressors, Danfoss thermostatic expansion valves, R404A/R23/R14 refrigerant blend |
| Insulation | High-density fiberglass wool (≥100 mm thickness) |
| Interior Material | SUS304 stainless steel, precision TIG-welded |
| Door Seal | High-performance silicone gasket (low-temp flexibility & high-temp stability) |
| Controller | Programmable color LCD touchscreen PID controller with real-time logging |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, IEC 60068-2-14, MIL-STD-810H Method 503.5, DIN EN 60068-2-14 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +150 °C (selectable) |
| Internal Chamber Dimensions | 400 × 500 × 500 mm (OK-TS-100) / 500 × 650 × 700 mm (OK-TS-250) |
| External Dimensions | 1030 × 1020 × 1470 mm / 1100 × 1170 × 1700 mm |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ≤ ±0.5 °C |
| Heating Rate | ≥ 2–3 °C/min |
| Cooling Rate | ≤ 1 °C/min |
| Refrigeration System | Twin-stage cascade refrigeration with hermetic French Tecumseh compressors |
| Insulation | High-density ultra-fine glass fiber |
| Heating Element | Nickel-chromium alloy sheathed heaters |
| Evaporator | Finned multi-section evaporator |
| Air Circulation | Single-loop, extended-shaft low-noise stainless steel centrifugal blower |
| Door Seal | High-performance silicone rubber gasket rated for −70 °C to +150 °C |
| Control System | Imported precision digital PID controller with solid-state relays and industrial-grade I/O modules |
| Safety Protections | Over-temperature, compressor high-pressure, phase failure, motor overload, door interlock, and refrigerant leak detection |
| Brand | Other brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General distributor |
| Price | USD 13,800 (approx. based on ¥100,000 at 7.25 exchange rate) |
| Internal Dimensions (W×H×D) | 400×450×400 mm to 1000×1000×1000 mm |
| Construction | SUS304 stainless steel inner chamber, A3 steel outer shell with powder coating |
| Viewing Window | Reinforced heated tempered glass with LED lighting |
| Test Port | Ø50 mm on left side |
| Controller | Touchscreen PID temperature controller with parameter lock and auto-tuning |
| Refrigeration | Dual-stage or single-stage cascade system with Tecumseh (France) compressors, Acro (USA) dry filters, Guanya (Taiwan) oil separators, Castel (Italy) solenoid valves |
| Air Circulation | Multi-wing centrifugal blower with optimized inlet/outlet duct design for uniform thermal distribution and rapid recovery (<5 min after door opening) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model | HAAKE Falling Ball |
| Instrument Type | Falling Ball Viscometer |
| Viscosity Range | 0.5 – 100,000 mPa·s |
| Temperature Range | −1 °C to +26 °C |
| Repeatability | < 0.5 % |
| Reproducibility | < 1 % |
| Measurement Tube Material | Borosilicate Glass (Tubes 1, 2, G) |
| Ball Materials | Nickel–Iron Alloy (Balls 3, 4, 5, 6) |
| Compliance | DIN 53015, ISO 120587 |
| Optional Accessories | Digital Stopwatch, Ball G (for gas viscosity), PT100 Temperature Sensor for HAAKE D50 Circulator |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1×10⁻⁸ rpm |
| Frequency Range | 1×10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Angular Displacement Resolution | 12 nrad |
| Normal Force Range | 0.01 – 50 N |
| Normal Force Resolution | 0.001 N |
| Vertical Travel | 240 mm |
| Gap Resolution | 0.5 µm |
| Minimum Vertical Speed | 0.02 µm/s |
| Maximum Vertical Speed | 20 mm/s |
| Temperature Range (with optional modules) | −150 °C to +600 °C |
| Dimensions (W×D×H) | 600 × 600 × 890 mm |
| Weight | 59 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Torque Rheometer |
| Model | PolyLab OS |
| Motor Bearing | Screw-driven |
| Minimum Speed | 1 rpm |
| Frequency Range | 0.1–115 rad/s |
| Maximum Speed | 250 rpm (up to 1100 rpm optional) |
| Maximum Torque | 120 mNm (dual-range: 120/400 Nm) |
| Torque Resolution | 0.01 / 0.1 Nm |
| Temperature Range | Up to 400 °C (optional 450–500 °C) |
| Heating/Cooling | Electric heating + compressed air cooling |
| Control Zones | 7–10 independent temperature zones |
| Pressure Capability | Up to 700 bar |
| Barrel Design | Modular, horizontally split |
| Screw Configurations | Single-screw (Ø19.05 mm), Conical counter-rotating twin-screw (Ø31.8/20 mm), Parallel co-rotating twin-screw (Ø16/24 mm), Banbury-type mixer (120/625 cm³ chamber volume) |
| Power Supply | 7 kW / 16 kW |
| L/D Ratios | 10:1, 25:1, 33:1 (single-screw) |
| 25 | 1 to 40:1 (twin-screw) |
| Extrusion Capacity | ~5 kg/h (polymer-dependent) |
| Compliance | DIN 1.4301 stainless steel (mixer), DIN 1.8550 nitrided steel (screws/barrels) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PolyLab QC |
| Instrument Category | Torque Rheometer |
| Drive Bearing | Single-screw configuration |
| Minimum Speed | 1 rpm |
| Frequency Range | 1–21 rad/s |
| Maximum Speed | 200 rpm |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Torque Accuracy | ±0.15% of full scale |
| Temperature Range | Up to 450 °C (heating via electric cartridge heaters |
| Screw Material | Nitrided stainless steel (DIN 1.8550) |
| Chamber Material | Stainless steel (DIN 1.4301) |
| Mixer Chamber Volume | 120 cm³ or 625 cm³ |
| Screw Diameter | 19.05 mm (single-screw unit) / 31.8 mm & 20 mm (conical counter-rotating twin-screw unit) |
| Screw L/D Ratio | 25 |
| Screw Length | 300 mm |
| Gear Ratio | 3:2 |
| Maximum System Pressure | 700 bar |
| Power Rating | 4 kW |
| Control Interface | USB or optional Ethernet (LAN) |
| Software Platform | HAAKE PolySoft v7.x (Windows-based) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Rotational Viscometer |
| Model | VT C / VT D / VT E |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Accuracy | ±1 % FSD |
| Repeatability | 0.2 % FSD |
| Speed Range | 0.01 – 200 rpm |
| Compliance | ISO 2555, ASTM D1084/D2196/D2556/D2983/D3232, BS 6075/5350 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Viscometer |
| Model | HAAKE Viscotester D |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Compliance | ISO 2555 |
| Rotor Geometry | Standard Spindle (e.g., LV, RV, HA, HB series) |
| Shear Rate Range | Dependent on spindle geometry and rotational speed (typically 0.1–1000 s⁻¹) |
| Accuracy | ±1% of full scale (per ISO 2555 calibration requirements) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer |
| Motor Bearing | Air-bearing-free (direct-drive torque sensor) |
| Minimum Angular Velocity | 0.001 rad/s |
| Maximum Angular Velocity | 157 rad/s (≈1500 rpm) |
| Torque Range | 0.2–100 mN·m |
| Torque Resolution | 0.002 mN·m (0.2% of full scale) |
| Oscillation Frequency Range | 0.01–100 Hz (with optional oscillatory module) |
| Temperature Control | Peltier-based, -10 to +130 °C (with coaxial cylinder or cone/plate geometry) |
| Geometry Auto-Recognition | Yes |
| Interface | 7″ capacitive touchscreen + USB host/device + Ethernet |
| Software | HAAKE RheoApp (standalone on USB drive) and HAAKE RheoWin (PC-based, GLP-compliant) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | VT550 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 2 – 10⁷ mPa·s |
| Speed Range | 0.5 – 800 rpm |
| Torque Range | 0.1 – 50 mN·m (up to 400 rpm), 0.1 – 20 mN·m (up to 800 rpm) |
| Temperature Range | −40 °C to +350 °C (dependent on optional temperature control unit) |
| Compliance Standards | ISO 2555, ISO 3219, DIN 53018, DIN 53019 |
| Control Mode | Preset Programs (10 built-in), Controlled Deformation (CD) mode for yield stress determination |
| Software Integration | RheoWin (HAAKE proprietary software) |