| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY(XB)-22JUNNYHGF |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energy | 22 J |
| Impact Velocity | 3.5 m/s |
| Pendulum Torque (Impact Constant) | 0.001 J·deg⁻¹ |
| Load Cell Range | 22 J |
| Maximum Pendulum Lifting Height | 395 mm |
| Display | Color Touchscreen (English/Chinese) |
| Angle Sensor | Omron Encoder, ±0.01° resolution |
| Energy Resolution | 0.01 J |
| Pendulum Angle | 150° |
| Distance from Pendulum Pivot to Impact Blade | 335 mm |
| Distance from Impact Blade to Clamp Upper Surface | 22 mm |
| Blade Tip Radius | R = 0.8 ± 0.2 mm |
| Net Weight | 85 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY(XB)-22J |
| Price Range | USD 1,400–2,800 |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energy | 22 J |
| Impact Velocity | 3.5 m/s |
| Pendulum Moment (Impact Constant) | 1 N·m/rad |
| Load Cell Range | 1 kN |
| Maximum Pendulum Lifting Height | 1 m |
| Display | Color Touchscreen (English/Chinese) |
| Angular Resolution | 0.01° (Omron Encoder) |
| Energy Resolution | 0.01 J |
| Impact Blade Radius | R = 0.8 ± 0.2 mm |
| Support Span | 60 mm (per ISO 180) |
| Specimen Clamp Distance to Blade | 22 mm |
| Pendulum Axis to Blade Distance | 335 mm |
| Pendulum Elevation Angle | 150° |
| Weight | 85 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY(XB)-22JFB |
| Instrument Type | Pendulum Impact Tester |
| Nominal Impact Energy | 22 J |
| Impact Velocity | 3.5 m/s |
| Pendulum Constant (Torque) | 0.01 J/deg |
| Load Cell Range | 22 J |
| Maximum Pendulum Lifting Height | 0 mm |
| Display | Full-color TFT touchscreen (bilingual: English & Chinese) |
| Angle Sensor | Omron rotary encoder, resolution 0.01° |
| Energy Resolution | 0.01 J |
| Pendulum Raise Angle | 150° |
| Distance from Pendulum Pivot to Impact Blade | 335 mm |
| Distance from Impact Blade to Clamp Upper Surface | 22 mm |
| Blade Tip Radius | R = 0.8 ± 0.2 mm |
| Machine Weight | 85 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HY(YE)-200008 |
| Max Load Capacity | 2000 kN |
| Accuracy Class | Class 1 (GB/T 3159 & ISO 7500-1) |
| Force Measurement Range | 200–2000 kN |
| Force Indication Relative Error | ±1% |
| Internal Clear Span | 450 mm |
| Upper/Lower Platen Dimensions | 240 × 240 mm |
| Piston Stroke | 80 mm |
| Motor Power | 0.75 kW |
| Net Weight | ~800 kg |
| Overall Dimensions (W×D×H) | 850 × 500 × 1480 mm |
| Deformation Indication Accuracy | ±0.5% of reading |
| Displacement Indication Relative Error | ±0.5% of reading |
| Stress Rate Control Range | 1–60 N/mm²/s |
| Strain Rate Control Range | 0.00025–0.0025 s⁻¹ |
| Closed-Loop Control Accuracy (Force/Displacement/Deformation) | ±1% of set value |
| Key Components | High-Precision Electro-Hydraulic Proportional Valve, Dual High-Accuracy Load & Displacement Sensors, Microcomputer-Based Electro-Hydraulic Proportional Control System, Real-Time Closed-Loop Test Software with A4 Color Report Generation and Database Storage |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HY(YE)-200008 |
| Max Load Capacity | 2000 kN |
| Accuracy Class | Class 1 (per GB/T 3159 & ISO 7500-1) |
| Force Measurement Range | 200–2000 kN |
| Relative Indication Error | ±1% |
| Internal Clear Distance | 450 mm |
| Upper/Lower Platen Dimensions | 240 × 240 mm |
| Piston Stroke | 80 mm |
| Motor Power | 0.75 kW |
| Net Weight | ~800 kg |
| Overall Dimensions (W×D×H) | 850 × 500 × 1480 mm |
| Deformation Measurement Accuracy | ±0.5% of reading |
| Displacement Measurement Error | ±0.5% of reading |
| Stress Rate Control Range | 1–60 N/mm²/s |
| Strain Rate Control Range | 0.00025–0.0025 s⁻¹ |
| Closed-Loop Control Accuracy (Force/Displacement/Deformation) | ±1% of setpoint |
| Key Components | High-Precision Electro-Hydraulic Proportional Valve, Dual High-Accuracy Load & Displacement Sensors, Microcomputer-Based Electro-Hydraulic Proportional Control System, Full-Closed-Loop Test Software with A4 Color Report Generation and Data Archiving |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HY(YE)-200008A |
| Max Load Capacity | 2000 kN |
| Accuracy Class | Class 1 (per GB/T 3159 & ISO 7500-1) |
| Force Measurement Range | 200–2000 kN |
| Relative Indicated Error | ±1% |
| Clear Distance Between Columns | 450 mm |
| Upper/Lower Platen Dimensions | 240 × 240 mm |
| Piston Stroke | 80 mm |
| Motor Power | 0.75 kW |
| Net Weight | ~800 kg |
| Overall Dimensions (W×D×H) | 850 × 500 × 1480 mm |
| Deformation Measurement Accuracy | ±0.5% of reading |
| Displacement Measurement Error | ±0.5% of reading |
| Stress Rate Control Range | 1–60 N/mm²/s |
| Strain Rate Control Range | 0.00025–0.0025 s⁻¹ |
| Closed-Loop Control Accuracy (Force/Displacement/Deformation) | ±1% of set value |
| Hydraulic Control | High-Precision Electro-Hydraulic Proportional Valve |
| Sensors | High-Accuracy Load Cell & Linear Displacement Transducer |
| Control System | Dedicated Microcomputer-Based Electro-Hydraulic Proportional Closed-Loop Controller |
| Software | Full-featured Test Management Suite with A4 Color Report Generation, Data Archiving, and Audit-Trail-Capable Export |
| Brand | Hengyi / Hengyitest |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HY(YE)-200008RTY |
| Quotation | Upon Request |
| Load Capacity | 2000 kN |
| Accuracy Class | Class 1 |
| Force Measurement Range | 80–2000 kN |
| Relative Indicated Error | ±1% |
| Loading Speed | 1–15 mm/s (adjustable) |
| Internal Clearance (between platens) | 320 mm |
| Upper Platen Dimensions | 220 × 220 mm |
| Lower Platen Diameter | 290 mm |
| Piston Stroke | 80 mm |
| Motor Power | 1.5 kW |
| Net Weight | ~1000 kg |
| Overall Dimensions | 520 × 440 × 1360 mm |
| Standard Configuration | Compression fixture set, one precision hydraulic load cell, Dell desktop PC + HP printer, micro-precision electro-hydraulic servo control system |
| Compliant Standards | GB/T 228–2002, GB/T 5224–1995, GB/T 232–1999 |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY(YE)-200008TYH |
| Price | Upon Request |
| Max Load Capacity | 2000 kN |
| Accuracy Class | Class 1 (per ISO 7500-1 & ASTM E4) |
| Force Measurement Range | 200–2000 kN |
| Indicated Relative Error | ±1% |
| Loading Rate Adjustment | 1–15 mm/s (mechanically regulated via manual oil valve) |
| Internal Clear Span | 450 mm |
| Upper Platen Dimensions | 240 × 240 mm |
| Lower Platen Dimensions | 240 × 240 mm |
| Piston Stroke | 80 mm |
| Motor Power | 0.75 kW |
| Net Weight | ~800 kg |
| Overall Dimensions (W×D×H) | 850 × 500 × 1480 mm |
| Standard Fixture | One set of compression platens |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY(YE)-300008 |
| Price | Upon Request |
| Maximum Load Capacity | 3000 kN |
| Accuracy Class | Class 1 (per GB/T 3159 & ISO 7500-1) |
| Force Measurement Range | 300–3000 kN |
| Indicated Relative Error | ±1% |
| Loading Rate Adjustment | 1–15 mm/s (manually controlled via hydraulic flow valve) |
| Internal Clear Span | 450 mm |
| Upper Platen Dimensions | 280 × 280 mm |
| Lower Platen Dimensions | 280 × 280 mm |
| Piston Stroke | 80 mm |
| Motor Power | 0.75 kW |
| Net Weight | ~1000 kg |
| Overall Dimensions (W×D×H) | 950 × 560 × 1570 mm |
| Standard Fixture | One set of compression platens with alignment guides |
| Brand | Hengyi / Hengyitest |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY(YE)-300008RTYY |
| Quotation | Upon Request |
| Maximum Load Capacity | 3000 kN |
| Accuracy Class | Class 1 |
| Force Measurement Range | 120–3000 kN |
| Relative Indicated Error | ±1% |
| Loading Speed | 1–15 mm/s (adjustable) |
| Clear Distance Between Columns | 320 mm |
| Upper Platen Dimensions | 320 × 220 mm |
| Lower Platen Dimensions | 400 × 400 mm |
| Piston Stroke | 80 mm |
| Motor Power | 2.2 kW |
| Net Weight | ~1500 kg |
| Overall Dimensions (W×D×H) | 700 × 550 × 1800 mm |
| Compliance Standards | GB/T 228–2002, GB/T 5224–1995, GB/T 232–1999 |
| Brand | Hengyi (Hengyitest) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY1000N·m |
| Price Range | USD 2,800 – 7,000 |
| Torque Capacity | 1000 N·m |
| Torque Measurement Accuracy | ±0.5% FS |
| Angular Displacement Range | 0–100,000° (or continuous rotation) |
| Angular Measurement Accuracy | ±0.5% FS |
| Twist Speed Range | 0–1000 °/min |
| Speed Control Accuracy | ±0.5% |
| Gauge Length Adjustment | 550 mm max |
| Specimen Clamping Diameter | Φ6–Φ32 mm (customizable) |
| Host Dimensions (L×W×H) | ≈1500×420×1250 mm |
| Power Supply | Single-phase 1.5 kW |
| Weight | 500 kg |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY200N·m |
| Torque Range (Total) | 0–200 N·m |
| Thread Torque Range | 0–100 N·m |
| Axial Force Range | 0.3–30 kN |
| Torque Measurement Accuracy | ±1% FS |
| Twist Angle Range | 0–100,000° |
| Twist Angle Accuracy | ±1% FS |
| Rotational Speed Range | 0–30 rpm |
| Speed Accuracy | ±0.5% FS |
| Max Spacing Between Chucks | 200 mm |
| Specimen Thread Size | M2–M6 (customizable) |
| Power Supply | Single-phase 1.5 kW |
| Dimensions (W×D×H) | ~600 × 700 × 1800 mm |
| Weight | 200 kg |
| Drive System | Panasonic Servo Motor |
| Torque Sensor | High-Precision Strain-Gauge Type |
| Enclosure | Powder-Coated Steel Cabinet |
| Mobility | Integrated Castor-Mounted Trolley |
| Power Options | AC Mains or Optional Li-ion Battery Pack |
| Brand | Hengyi / Hengyitest |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HY-QKRBRTY |
| Quotation | Available Upon Request |
| Load Capacity | 2000 N (interchangeable load cells available below 2000 N |
| Effective Force Measurement Range | 0.4%–99.999% of full scale |
| Test Width | 120 mm |
| Vertical Test Space | 200 mm |
| Test Speed | 0.001–100 mm/min (adjustable in real time) |
| Speed Accuracy | ±1% of indicated value |
| Displacement Accuracy | ±1% of indicated value |
| Strain/Deformation Accuracy | ±1% of indicated value |
| Number of Test Stations | 12 |
| Temperature Bath Control Range | Ambient to 95 °C |
| Temperature Stability | ±0.5 °C |
| Control System | PC-based closed-loop control |
| Power Requirement | 10 kW |
| Unit Weight | 850 kg |
| Voltage Supply | 220 V AC |
| Dimensions (W×D×H) | 1620 × 850 × 1750 mm |
| Compliance Standards | GB/T 15820–1995, GB/T 11546–2016, GB/T 32682–2016, ISO 899-1:2017, ISO 16770:2017, ISO 3501:1997 |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HY-1080TYHHH |
| Instrument Type | Electromechanical Tensile Testing Machine |
| Maximum Test Load | 10 kN |
| Force Measurement Range | 0.001–100% of Full Scale |
| Force Accuracy | ±0.5% FS |
| Test Stroke | 800 mm |
| Displacement Resolution | 0.001 mm |
| Load Cell Accuracy | 0.01% FS |
| Speed Range | 0.001–500 mm/min |
| Speed Accuracy | ±0.5% |
| Displacement Measurement Accuracy | ±0.5% |
| Effective Test Width | ~380 mm |
| Safety Features | Electronic Limit Switches, Emergency Stop Button |
| Power Supply | 220 V AC |
| Unit Weight | ~210 kg |
| Dimensions (W×D×H) | 700 × 420 × 1600 mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Henkel Loctite Series (221, 222, 241–243, 262, 270–279, 290, 414–415, 480, 496, 601–609, 620, 638–641, 660, 672–675, Primer T7471/N7649, C5-A, Moly 50, 08031–08931) |
| Pricing | Available Upon Request |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Custom-Engineered |
| Price Range | USD 140,000 – 280,000 |
| High-Temperature Range | 1400 °C |
| Low-Temperature Range | −20 °C |
| Thermal Shock ΔT Range | 1420 °C |
| Temperature Stability | ±0.5 °C |
| Heating Rate | 80 °C/min |
| Cooling Rate | 80 °C/min |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dynamic Mechanical Analyzer (DMA/DMTA) |
| Temperature Range | -150 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Maximum Applied Force | 50 N |
| Displacement Range | 2.5 mm |
| Frequency Range | 0.01–100 Hz |
| Heating Rate | 0.1–20 °C/min (dual-loop self-learning PID control) |
| Force Resolution | 0.001 N |
| Displacement Resolution | 0.01 µm |
| Atmosphere Control | Dual-channel mass flow controller (0–200 mL/min), inert/oxidizing/reducing/static/dynamic gas modes |
| Sample Dimensions | Height 0.3–25 mm, Diameter ≤10 mm |
| Operating Modes | Tension, Compression, Bending (3-point & cantilever), Shear, Penetration |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HCR |
| Price Range | USD 10,800–15,000 (FOB Beijing) |
| Sample Capacity | Single-sample configuration |
| Instrument Type | Differential Thermal Analysis (DTA) |
| Temperature Range | RT to 1150 °C (HCR-1), RT to 1250 °C (HCR-2), RT to 1450 °C (HCR-3), RT to 1550 °C (HCR-4) |
| Programmable Temperature Control | Heating and Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Operating Mode | Fully Automated |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Scan Modes | Dynamic heating, isothermal stabilization |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | ±1 mW to ±500 mW |
| Temperature Stability (Drift) | ≤0.1 °C over 24 h |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| Voltage Input Range | ±10 µV to ±2000 µV (auto-ranging) |
| Vacuum Capability (Optional) | 2.5×10⁻² Pa |
| Atmosphere Control | Dual-channel mass flow controller (MFC)-based gas delivery with automatic switching |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional | Aluminum, graphite, quartz, platinum |
| Isothermal Duration | Up to 72 h at any setpoint within operating range |
| Calibration Standards Supported | Indium, tin, lead (for temperature and enthalpy calibration) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HCR-1 |
| Sample Capacity | Single-sample |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Temperature Range | Ambient to 1150 °C |
| Programmable Temperature Control | Heating and Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| Scan Modes | Dynamic heating, isothermal hold |
| DSC Measurement Range | ±1–±500 mW |
| DSC Sensitivity | ±0.1 μW |
| DTA Resolution | 0.01 μV |
| DTA Noise Level | <0.01 μV |
| Signal Range | ±10–±2000 μV (auto-ranging) |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Atmosphere Control | Dual-channel mass flow controller (MFC), programmable gas switching, corrosion-resistant options available |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Isothermal Duration | Up to 72 h at any temperature within range |
| Calibration Standards Supported | Indium, tin, lead |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-2 |
| Temperature Range | Ambient to 1250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| DTA Sensitivity | 0.01 μV |
| DTA Noise Level | <0.01 μV |
| DSC Measurement Range | ±1–±500 mW |
| DSC Precision | ±0.1 μW |
| Sample Capacity | Single-sample configuration |
| Control Mode | Manual sample loading |
| Thermal Program Modes | Ramp heating, isothermal hold (up to 72 h at any temperature within range) |
| Atmosphere Control | Dual-channel mass flow controller (MFC)-based gas delivery with automatic switching |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Signal Output Range | ±10–±2000 μV (auto-ranging) |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Interface | Integrated LCD display showing furnace temperature, sample temperature, gas status, and real-time signal |
| Software Features | Oxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, peak integration, enthalpy calculation, activation energy estimation (multiple algorithms), Tg determination, specific heat comparison method, calibration support (In, Sn, Pb), screenshot capture at arbitrary timestamps, user-defined formula implementation |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-3 |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min (user-definable) |
| DTA Signal Range | ±10 µV to ±2000 µV (auto-ranging) |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV |
| DSC Measurement Range | ±1 mW to ±500 mW |
| DSC Sensitivity | ±0.1 µW |
| Atmosphere Control | Dual-channel MFC-controlled gas system (N₂, Ar, O₂, air |
| Vacuum Option | 2.5×10⁻² Pa (with optional vacuum unit) |
| Isothermal Hold Duration | Up to 72 h at any temperature within range |
| Standard Crucibles | Al₂O₃ (0.06 mL or 0.12 mL) |
| Optional Crucibles | Aluminum, graphite, quartz, platinum |
| Software Features | Oxidation Induction Time (OIT) analysis, crystallization kinetics modeling, step-cooling curve generation, peak integration, enthalpy calculation, activation energy determination (multiple model algorithms), Tg identification, specific heat comparison method, real-time screenshot capture, auto-scale signal acquisition, calibration support (In, Sn, Pb standards) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DTA (Differential Thermal Analysis) |
| Model | HCR-4 |
| Sample Capacity | Single-sample configuration |
| Temperature Range | Ambient to 1550 °C |
| Programmable Temperature Control | Heating and Isothermal hold |
| Temperature Accuracy | ±0.1 °C |
| Temperature Stability (Drift) | ≤0.1 °C over 24 h |
| Heating/Cooling Rate | 0.1–100 °C/min (user-definable) |
| DTA Signal Range | ±10 µV to ±2000 µV (auto-ranging) |
| DTA Resolution | 0.01 µV |
| DTA Noise Level | <0.01 µV (RMS) |
| DSC Measurement Range | ±1 mW to ±500 mW |
| DSC Sensitivity | ±0.1 µW |
| Atmosphere Control | Dual-channel mass flow controller (MFC), programmable gas switching, corrosion-resistant options available |
| Vacuum Capability (optional) | 2.5×10⁻² Pa |
| Isothermal Hold Duration | Up to 72 h at any temperature within range |
| Calibration Standards Supported | In, Sn, Pb, and user-defined reference materials |
| Optional Accessories | GC/MS transfer line (thermostatted to 200 °C), ceramic/alumina/graphite/quartz/platinum crucibles (0.06 mL & 0.12 mL standard) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HCT-1 |
| Price Range | USD 12,500 – 18,000 (FOB Beijing) |
| Temperature Range | Ambient to 1150 °C |
| Heating Rate | 0.1–100 °C/min (user-definable) |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 5 g |
| Atmosphere Control | Dual-channel mass flow controller (MFC) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HCT-2 |
| Price Range | USD 14,000 – 20,000 (FOB Beijing) |
| Temperature Range | Ambient to 1250 °C |
| Heating Rate | 0.1–100 °C/min (programmable) |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 5 g |
| Atmosphere Control | Dual-channel mass flow controller (MFC) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HCT-3 |
| Temperature Range | Ambient to 1450 °C |
| Heating Rate | 0.1–100 °C/min (user-definable) |
| Temperature Stability | ±0.1 °C |
| Max Sample Mass | 5 g |
| Atmosphere Control | Dual-channel mass flow controller (MFC) |
| DSC Range | ±1 mW to ±500 mW |
| DSC Sensitivity | ±0.1 μW |
| TG Measurement Range | 1–200 mg |
| TG Resolution | 0.1 μg |
| TG Noise | <0.1 μg |
| Vacuum Capability | 2.5×10⁻² Pa (with optional vacuum pump) |
| DTA Range | ±10 μV to ±2000 μV |
| DTA Resolution | 0.01 μV |
| Crucible Options | Al₂O₃ (0.06 mL / 0.12 mL), Al, graphite, quartz, Pt |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HCT-4 |
| Heating Rate | 0.1–100 °C/min |
| Temperature Range | Ambient to 1550 °C |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 5 g |
| Atmosphere Control | Dual-channel mass flow controller (customizable for corrosive gases) |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Heat Flow Meter Method |
| Sample Capacity | Single Sample per Test |
| Test Environment | Ambient Temperature |
| Thermal Conductivity Range | 0.001–5 W/m·K |
| Accuracy | ±3% |
| Repeatability | ±1% |
| Temperature Control Range | 0–90 °C |
| Sample Dimensions | 300 × 300 × (2–50) mm or 200 × 200 × (2–50) mm |
| Thickness Adjustment | Motorized, Auto-Calibrating |
| Applied Load Range | 0–1500 N |
| Thickness Measurement | High-Precision Displacement Sensor with Zeroing & Calibration Function |
| Compliance Standards | GB/T 10295-2008, ASTM C518, ISO 8301:1991 |
| Brand | Henven (Beijing) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HFCT-1 |
| Structural Design | Horizontal Configuration |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Class | General-Purpose TGA-DTA/DSC Hybrid |
| Temperature Range | RT to 900 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision (Uncertainty) | 0.1 K |
| Dynamic Weight Range | 1–300 mg |
| Balance Sensitivity | 0.1 μg |
| Mass Accuracy | 0.1 μg |
| Heating/Cooling Rate | Up to 300 K/min |
| Maximum Load Capacity | 5 g |
| DSC Signal Range | ±500 mW |
| DSC Resolution | ±0.1 μW |
| DSC Accuracy | ±0.1 μW |
| DTA Voltage Range | ±10–±2000 μV |
| DTA Resolution | 0.01 μV |
| TG Noise Level | <0.1 μg |
| Atmosphere Control | Dual-channel Mass Flow Controllers (MFCs), Programmable Gas Switching, Compatible with Inert, Oxidizing, Reducing, and Vacuum (Optional) |
| Crucible Standard | Al₂O₃ |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Temperature Range | Ambient to 1200 °C |
| Programmable Temperature Control | Heating & Isothermal Hold |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–80 °C/min |
| Temperature Precision | ±0.1 °C |
| DSC Signal Range | ±500 mW |
| Temperature Stability (Drift) | ±0.1 °C |
| Minimum Heat Flow Resolution | 0.1 µW |
| Power Noise Level | <0.1 µW |
| Crucible Volume | 0.06–0.12 mL |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | HKG |
| Price Range | USD 14,000–28,000 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | Dedicated TGA System |
| Temperature Range | RT to 950 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | Up to 10 K/min (standard), configurable up to 300 °C/min |
| Maximum Sample Mass | 5 g |
| Baseline Drift | ≤0.01% of full scale |