| Brand | Bettersize |
|---|---|
| Model | BT-1001 |
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instruments Co., Ltd. |
| Instrument Type | Powder Flowability & Bulk Property Tester |
| Measurable Parameters | Angle of Repose, Collapse Angle, Angle of Fall, Dispersibility, Tapped Density, Bulk Density, Flowability Index, Spoutability Index, Difference Angle, Compressibility, Porosity, Cohesion Index, Uniformity Index, Sieve Particle Size (optional integration) |
| Maximum Sample Vessel Capacity | 40 mL |
| Minimum Sample Requirement | 10 mL |
| Tapping Frequency Range | 50–300 taps/min (continuously adjustable) |
| Tapping Amplitude Options | 3 mm or 14 mm (pre-selectable) |
| Power Supply | 220 VAC, 50/60 Hz, 4 A |
| Control Interface | Integrated Android tablet (wireless) or Windows PC (USB/Ethernet) |
| Compliance | GB/T 31057.2–2018, GB/T 31057.3–2018, GB/T 16913–2008, GB/T 1479.1–2011, GB/T 5162–2021, ASTM D6393–21, USP-NF <616> (2025), Ph. Eur. 11.0 / 20934 |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | BT-101 |
| Instrument Type | Apparent Density Tester (Scott Volumeter Method) |
| Measurable Material | Metal Powders |
| Compliance Standards | GB/T 1479.2–2011, ISO 3923-2, USP <616>, Ph. Eur. 2.9.34, ChP 2020 General Chapter 0993 |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instrument Co., Ltd. |
| Model | BT-102 |
| Instrument Type | Powder Flowability Tester |
| Compliance | ASTM B213, ASTM B527, ISO 4490, ISO 3953 |
| Funnel Orifice Options | 2.5 mm and 5.0 mm |
| Standard Cup Material | Stainless Steel (304) |
| Cup Volume | 25 mL |
| Timing Resolution | 0.1 s |
| Mass Measurement Accuracy | ±0.05 g |
| Density Reporting Precision | ±0.01 g/cm³ |
| Brand | Bettersize |
|---|---|
| Model | BT-103 |
| Measurement Principle | Fixed-base funnel method (gravity-fed conical pile formation) |
| Measured Parameter | Angle of Repose (θr) |
| Compliance | GB/T 16913–2008, USP <1174>, Ph. Eur. 2.9.36 |
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instruments Co., Ltd. |
| Type | Static Image Analyzer |
| Measurement Range | 0.3–4500 µm |
| Magnification Options | 80× / 160× / 400× / 1600× / 4000× |
| Camera Resolution | 12 MP |
| Repeatability & Accuracy (D50) | ≤1% (per GB/T standard reference materials) |
| Calibration Standard | NIST-traceable micrometer scale (10 µm division) |
| Pixel-to-Size Calibration | Direct pixel mapping via stage-mounted graticule |
| Operating System | Windows 10/11 |
| Interface | USB 3.0 |
| Particle Parameters | Area-equivalent diameter, perimeter-equivalent diameter, major/minor axis (Feret), conjugate Feret diameter, Legendre ellipse major/minor axis, Martin length/width |
| Shape Parameters | Aspect ratio, circularity (11 algorithms), elongation, straightness, ellipticity, irregularity, compactness, convexity, concavity, solidity, convex hull ratio |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BT-1700 |
| Instrument Type | Static |
| Measurement Range | 0.3–10,000 µm |
| Magnification Options | 160×, 200×, 400×, 800× |
| Repeatability Error | ≤1% (D₅₀ deviation against national standard reference materials) |
| Accuracy Error | ≤1% (D₅₀ deviation against national standard reference materials) |
| Illumination | Dual-mode (transmitted + reflected light) |
| Particle Recognition Speed | ≥10,000 particles/minute |
| Camera Resolution | 12 MP |
| Scan Area Diameter | 50 mm |
| Analysis Time per Sample | ≤10 minutes |
| Brand | Bettersize |
|---|---|
| Model | BT-2800 |
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instruments Co., Ltd. |
| Instrument Type | Dynamic |
| Measurement Range | 4–400 µm |
| Magnification | 20×–1400× |
| Repeatability Error | ≤1% (D50, certified reference material) |
| Accuracy Error | ≤1% (D50, certified reference material) |
| High-Speed CCD | 120 fps |
| Particle Recognition Speed | ≥10,000 particles/min |
| Power Supply | 100–240 VAC, 50/60 Hz, 4 A |
| Dimensions | 610 × 300 × 450 mm |
| Weight | 22 kg |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | BT-2900 |
| Instrument Type | Dynamic |
| Measurement Range | 30–10,000 µm (dry dispersion) |
| Sample Dispersion Method | Dry & Wet |
| Magnification | 0.132×–10× (interchangeable lenses) |
| Repeatability Error | ≤1% (D50 deviation vs. national standard reference material) |
| Accuracy Error | ≤1% (D50 deviation vs. national standard reference material) |
| High-Speed Camera | 1.5 MP, 120 fps |
| Particle Recognition Speed | ≥10,000 particles/min |
| Power Supply | 220 VAC, 50/60 Hz, 4 A |
| Dimensions | 610 × 300 × 440 mm |
| Weight | 26 kg |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instruments Co., Ltd. |
| Model | BT-310 Series (BT-311 / BT-312 / BT-313) |
| Instrument Type | Tap Density Tester |
| Cylinder Volumes | 25 mL, 100 mL, 250 mL (customizable) |
| Sample Mass Options | 10 g, 100 g, or user-defined |
| Tap Amplitude | 3 mm or 14 mm |
| Tap Frequency Range | 100–300 taps/min (continuously adjustable) |
| Max Counter Capacity | 99,999 taps |
| Sample Throughput | BT-311: 1 sample/batch |
| BT-312 | 2 samples/batch |
| BT-313 | 3 samples/batch |
| Repeatability | ≤1% RSD |
| Power Supply | 100–240 VAC, 50/60 Hz, 50 W |
| Compliance | ChP 2020, GB/T 31057–2018, GB/T 21354–2008, USP <616>, Eur. Ph. 2.9.34, ASTM D7481, ASTM B527, ISO 787–11, ISO 3953:1993 |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–1200 µm |
| Repeatability | ≤1% (D50 of certified reference materials) |
| Measurement Time | ≤10 s per analysis |
| Dispersion Method | Wet Dispersion |
| Optical Principle | Mie Scattering Theory (default), Fraunhofer Diffraction (optional) |
| Detector Array | 86-element photodiode array |
| Laser Source | High-power fiber-coupled laser |
| Optical Design | Patented dual-lens optical system with forward-, side-, and back-scatter detection |
| Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982 |
| Data Integrity | FDA 21 CFR Part 11 compliant audit trail and electronic signature support |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | ≤1% (D50 deviation vs. certified reference materials) |
| Measurement Time | ≤10 s per run |
| Dispersion Method | Wet Dispersion |
| Optical Principle | Mie Scattering Theory (default), Fraunhofer Diffraction (optional) |
| Detector Array | 80-channel photodiode array (forward + side scattering) |
| Laser Source | High-power fiber-coupled laser |
| Optical Design | Single-lens Fourier optical system |
| Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982 |
| Data Integrity | FDA 21 CFR Part 11–compliant audit trail and electronic signature support |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | BT-9300ST |
| Pricing | Upon Request |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Benchtop Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.05–1500 µm |
| Repeatability | ≤1% (D50, NIST-traceable standard reference materials) |
| Single-Measurement Time | ≤1 s |
| Optical System | Patented Dual-Lens Configuration |
| Laser Source | High-Power Fiber-Coupled Laser (638 nm) |
| Detector Array | 88-Channel Photodiode Array (Forward, Side, and Backward Scattering) |
| Scattering Theory | Mie Scattering (default), Fraunhofer Diffraction (optional) |
| Regulatory Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982 |
| Data Integrity | FDA 21 CFR Part 11 Compliant Audit Trail & Electronic Signature Support |
| Dispersion System | Integrated Auto-Circulating Wet Module with Ultrasonic Probe (0–50 W, adjustable), Auto-Fill, Auto-Drain, Bubble Elimination, and Self-Cleaning Functions |
| Operating Modes | SOP-Driven One-Touch Mode, Manual Mode, Continuous Monitoring Mode |
| Power Supply | 100–240 VAC, 50/60 Hz, 2.5 A |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | In-line Laser Particle Size Analyzer |
| Repeatability | ≤2% (D50, GB Standard Reference Material) |
| Particle Size Range | 0.1–2000 µm |
| Sediment Concentration Range | 0.001–100 kg/m³ |
| Optical Path Adjustment | Auto-adaptive 0.5–40 mm |
| Max Submersion Depth | 800 m (customizable) |
| IP Rating | IP68 |
| Operating Temperature | 0–55 °C |
| Depth Sensor Range | 0–200 m (±0.01 m accuracy) |
| Temperature Sensor Range | −20–85 °C (±0.01 °C accuracy) |
| Laser Source | High-power fiber-coupled polarized laser |
| Detector Array | 80-element forward + side-scatter detector (0.0163°–42° angular coverage) |
| Data Transmission Modes | Wired (real-time), 4G Wireless (real-time), Offline (SD card storage, 16 GB) |
| Battery Standby Time | ≥24 h |
| Compliance | GB/T 15966–2017 |
| Brand | Bettersize (Dandong Better Instruments Co., Ltd.) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Optical Particle Counter |
| Model | Bettersize C400 |
| Detection Principle | Combined Light Obscuration and Angular Light Scattering |
| Particle Size Range | 0.5–400 µm |
| Laser Source | Semiconductor Slab Beam Laser |
| Detection Channels | 4–100 (user-definable bin boundaries) |
| Sample Volume | 0.1–200 mL |
| Sampling Pump | 10 mL piston pump, accuracy ≤ ±1% |
| Flow Rate | 5–60 mL/min |
| Maximum Count Concentration | 45,000 particles/mL |
| Counting Repeatability Error | < ±1.5% (for standard particles >2000/mL, 10 mL sample) |
| Counting Resolution | <10% per ISO 21501-4 / GB/T 18854–2015 / USP <788> |
| Vacuum Capability | up to 0.08 MPa |
| Pressure Rating | up to 0.6 MPa |
| Sample Viscosity Range | 0–400 cSt |
| Sample Temperature Range | 0–80 °C |
| Environmental Operating Conditions | 10–40 °C, RH ≤80%, non-condensing |
| Power Supply | 200–240 VAC, 50/60 Hz, 200 W (without air pump) |
| Compliance Standards | ISO 4406, NAS 1638, GB/T 14039, GJB 420A/B, ISO 21501-4, USP <788>, EP 2.9.19, JP 17 |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instrument Co., Ltd. |
| Model | Bettersize3000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | ≤0.5% |
| Measurement Time | <10 s |
| Optical Principle | Mie Scattering (default), Fraunhofer Diffraction (optional), Dynamic Imaging |
| Detector Array | 96-element photodetector (forward, side, and backward angles) |
| Refractive Index Measurement | Yes (real & imaginary components) |
| Compliance | ISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982, FDA 21 CFR Part 11 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | FD |
| Temperature Range | Ambient + 5 °C to 300 °C |
| Internal Volume | 20 L (FD 23) |
| External Dimensions (W×H×D) | 435 × 495 × 520 mm |
| Internal Dimensions (W×H×D) | 222 × 330 × 300 mm |
| Net Weight | 27 kg |
| Heating Technology | PAT.line™ Preheating Chamber |
| Air Circulation | Adjustable forced convection |
| Exhaust Valve | Manually adjustable |
| Controller | Time-programmable digital controller with optical overtemperature alarm |
| Safety | Dual-stage temperature safety device (DIN 12880 Class 2) |
| Standard Accessories | 2 chrome-plated wire shelves |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | KB PRO / KBF / KBF PRO with ICH or ICH-LQC Illumination Modules |
| Temperature Range (No Humidity Control) | +18°C to +32°C |
| Temperature & Humidity Range (KBF Series) | +20°C to +50°C / 20–50% RH |
| Extended Temp/Humidity Range (KBF PRO Series) | +10°C to +50°C / 10–80% RH |
| Compliance | ICH Q1B Option 2 (Visible Light) and UV Supplement via Fluorescent Lamps |
| Illumination Types | LED (visible spectrum) + T8 Fluorescent (UV-A/UV-B) |
| Optional Light Dose Control (LQC) | Yes |
| Chamber Volumes | 260 L, 470 L, 720 L |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Chamber Volumes | 260 L, 470 L, 720 L, 1060 L, 1600 L |
| Temperature Range (KB PRO) | 0 °C to +50 °C (no humidity control) |
| Temperature Range (KBF) | 10 °C to +50 °C, Humidity Range: 10–50 % RH |
| Temperature Range (KBF PRO) | 10 °C to +50 °C, Humidity Range: 10–90 % RH |
| LED System | 16 modular strips, each with independently controllable warm white (3000 K), cool white (6500 K), and deep red (660 nm) channels |
| PAR Irradiance | Up to 1000 µmol·m⁻²·s⁻¹ (simulating full sunlight) |
| Control Interface | Touch-enabled external controller with programmable light recipes, twilight simulation, and fresh-air exchange mode |
| Compliance | Designed per IEC 61000-6-3 (EMC), EN 61010-1 (safety), and compatible with GLP/GMP documentation workflows |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB PRO Series |
| Temperature Range | –20 °C to +100 °C |
| Temp. Uniformity at 37 °C | ±0.2 K |
| Temp. Stability at 37 °C | ±0.1 K |
| Max. Heat Compensation at 37 °C | 450–1000 W |
| Recovery Time (30 s door opening, 37 °C) | 2–6 min |
| Internal Volume | 127–1610 L |
| Power Supply | 208–240 V, 50/60 Hz |
| Rated Power | 1.0–1.8 kW |
| Net Weight | 135–443 kg |
| Noise Level (25 °C) | 46–52 dB(A) |
| Refrigerant | R-290 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF PRO |
| Temperature Range | −20 to 100 °C |
| Humidity Range | 10–98 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.2 K (KBF PRO 130 & 260), ±0.3 K (KBF PRO 470–1600) |
| Temp. Stability (25 °C / 60 % RH) | ±0.1 K |
| Humidity Stability (25 °C / 60 % RH) | ±1 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1 min |
| Recovery Time (40 °C / 75 % RH, 30 s door open) | 3–5 min |
| Internal Volume | 127–1610 L |
| Power Consumption | 1.6–1.9 kW |
| Refrigerant | R-290 (eco-friendly hydrocarbon) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF Series |
| Type | Benchtop Environmental Test Chamber |
| Temperature Range | 0–70 °C |
| Humidity Range | 10–80 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.1–0.4 K |
| Humidity Stability (25 °C / 60 % RH) | ±1.5 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1–3 min |
| Power Consumption | 1.3–1.7 kW |
| Internal Volume | 127–1610 L |
| Refrigerant | R-600a |
| Compliance | DIN 12880, ICH Q1–Q5, GLP/GMP-ready |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Chamber Type | Upright |
| Model Families | KBF, KBF P, KBF LQC, KMF |
| Temperature Range (dry) | 0–70 °C |
| Temperature Range (humidified) | 10–70 °C |
| Humidity Range | 10–80 % RH |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | LIT MK 240 |
| Temperature Range | −40 °C to +110 °C (extendable to +120 °C with dual safety cut-off) |
| Temperature Uniformity | ±0.1 K to ±1.2 K (dependent on setpoint) |
| Temperature Stability | ±0.1 K to ±0.5 K |
| Heating Rate (IEC 60068-3-5) | 5 K/min |
| Cooling Time (110 °C → −40 °C) | 160 min |
| Average Cooling Rate (IEC 60068-3-5) | 3.5 K/min |
| Thermal Compensation at 25 °C | 3000 W |
| Rated Voltage | 400 V or 480 V AC, 3~ |
| Frequency | 50/60 Hz |
| Nominal Power | 5.6 kW |
| Fuse Rating | 16 A |
| Internal Volume | 228 L |
| Net Weight (empty) | 375 kg |
| Max. Load Capacity | 70 kg |
| Shelf Load per Rack | 30 kg |
| Viewing Window | 508 mm × 300 mm (heated, LED-lit) |
| Internal Dimensions (W×H×D) | 735 mm × 700 mm × 443 mm |
| External Dimensions (W×H×D) | 1335 mm × 1929 mm × 925 mm |
| Rear Clearance | 300 mm |
| Side Clearance | 200 mm |
| Sound Pressure Level | 62 dB(A) |
| Safety Systems | Dual independent Class 2 temperature cut-offs (DIN 12880), CO/H₂/O₂/temperature gas monitoring, CO₂ fire suppression, reinforced door lock, reversible stainless-steel pressure relief valve, APT.line™ pre-heating chamber, condensation protection programming, fluorine-free refrigerant R-452A |
| Control Interface | Touchscreen controller with time-segment & real-time programming, APT-COM™ Basic software, Ethernet interface, USB data export (open CSV format), internal datalogger, 230 V socket on right-side panel |
| Standard Equipment | 1 stainless-steel shelf, compressed-air-cooled refrigeration unit |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | LIT MK 720 |
| Temperature Range | –40 °C to +110 °C |
| Temperature Uniformity (±K) | 0.1–0.5 |
| Temperature Stability (±K) | 0.3–2.0 |
| Avg. Heating Rate (IEC 60068-3-5) | 4 K/min |
| Avg. Cooling Rate (IEC 60068-3-5) | 3.4 K/min |
| Internal Volume | 734 L |
| Max. Load Capacity | 160 kg |
| Net Weight | 570 kg (LIT MK 720-400V) / 522 kg (LIT MK 720-480V-C) |
| Power Supply | 400 V, 3~ |
| Refrigerant | R-452A |
| Sound Pressure Level | 65–67 dB(A) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | M, MK, MKT |
| Application Scope | Thermal Stress Testing, Stability & Durability Evaluation, Material Aging (per EN 60811-1-2 / IEC 60811-1-2) |
| Compliance | ISO 17025-accredited laboratory use, GLP/GMP-compatible operation, FDA 21 CFR Part 11-ready software options available |
| Cooling Method | Dual-circuit refrigeration with cascade system (for MKT series down to –70 °C) |
| Temperature Range | –70 °C to +180 °C (MKT), –40 °C to +180 °C (MK), –20 °C to +180 °C (M) |
| Uniformity | ±0.3 °C (at 100 °C, load-free) |
| Control System | BINDER CTC Advanced Touchscreen Controller with programmable ramp/soak profiles, real-time data logging, and Ethernet interface |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MDL |
| External Dimensions (L×H×W) | 834×800×685 mm |
| Internal Dimensions (L×H×W) | 600×435×435 mm |
| Temperature Range | +5 °C above ambient to 350 °C |
| Internal Volume | 115 L |
| Temperature Uniformity | ≤ ±0.5 °C |
| Airflow Rate | 400 L/min |
| Heating Power | 9.0 kW |
| Safety Class | Dual independent temperature safety device (DIN 12880, Class 2) |
| Fresh Air Filter | EU6 (F6), particle retention ≥1 µm |
| Rear Exhaust Port | Ø100 mm |
| Shelves | 2 chrome-plated adjustable shelves |
| Controller | MCS microprocessor-based controller with 25 stored programs, 100 segments per program, up to 500 total segments |
| Display | User-friendly LCD with intuitive menu navigation |
| Data Logging | Built-in electronic chart recorder with multiple real-time graphical display options |
| Real-Time Clock | Integrated |
| Ramp Function | Programmable via on-board editor |
| Door Seal | High-temperature silicone gasket |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MK Series |
| Temperature Range | –40 °C to +180 °C |
| Internal Volume | 56–1020 L |
| Temperature Uniformity | ±0.1 K to ±2.0 K (depends on setpoint) |
| Temperature Stability | ±0.1 K to ±0.5 K (depends on setpoint) |
| Heating Rate (IEC 60068-3-5) | up to 5.5 K/min |
| Cooling Rate (IEC 60068-3-5) | up to 4.5 K/min |
| Refrigerant | R-452A (non-ozone-depleting) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | MKF / MK / MKT |
| Internal Volume Options | 53 L, 115 L, 240 L, 400 L, 720 L |
| Temperature Range | MK/MKF: −40 °C to +180 °C |
| MKT | −70 °C to +180 °C |
| M-Series | +5 °C above ambient to +300 °C |
| Humidity Range (MKF only) | 10–98 % rH |
| Control System | MB1 4-channel touchscreen controller (25 programs × 100 segments) |
| Cooling Technology | DCT® Direct Cooling Technology |
| Preconditioning Chamber | APT-Line® |
| Air Circulation | Digitally adjustable high-power turbine |
| Compliance | DIN EN 60068-3-5, IEC 60068-3-6, ISO 16750-4, ASTM D4329, USP <1151> (environmental stress testing), GLP-compliant data logging via APT-COM software |
| Interface | RS422 for APT-COM v3.x integration |
| Insulation | High-efficiency vacuum-insulated door & polyurethane foam walls |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKFT |
| Temperature Range | –70 °C to +180 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.1–2.0 K (depending on setpoint and chamber size) |
| Temperature Fluctuation | ±0.1–0.5 K |
| Humidity Fluctuation | ≤±2.5 % RH |
| Heating Rate (IEC 60068-3-5) | up to 5.5 K/min |
| Cooling Rate (IEC 60068-3-5) | up to 4.2 K/min |
| Internal Volumes | 115 L / 228 L / 734 L |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKFT115 / MKFT240 / MKFT720 |
| Temperature Range | –70 °C to +180 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Internal Volume | 115 L / 228 L / 734 L |
| Refrigerant | R-452A |
| Humidity Control | Capacitive Sensor + Steam Humidification |
| Controller | MCS Touchscreen with Real-Time & Segment Programming |
| Data Logging | Integrated Internal Recorder + USB Export |
| Compliance | DIN 12880, IEC 60068-3-5, IEC 60068-3-6, MIL-STD-810G (climate profiles), GLP/GMP-ready audit trail support via optional software |