Physical Property Testing Instruments
Filter
Showing 691–720 of 12200 results
| Brand | Astroda |
|---|---|
| Model | XG5120 |
| Origin | Guangdong, China |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Detection Accuracy | 40 µm |
| Radiation Leakage | ≤1 µSv/hr (per IEC 61331-1 & FDA 21 CFR §1020.40) |
| Throughput | ≥30,000 units/day |
| Reconfiguration Time | 0.5–2 h |
| Compliance | CE, ISO 13485 (for medical device manufacturing support), GB/T 18871-2002, IEC 62495 |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XG5130 |
| Pricing | Available Upon Request |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Detection Accuracy | 40 µm |
| Radiation Leakage | ≤1 µSv/hr (compliant with IEC 61000-4-3 & IEC 62471) |
| Brand | Astroda |
|---|---|
| Model | XG5200D |
| X-ray Tube Voltage | Up to 110 kV |
| X-ray Tube Current | Up to 450 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Image Intensifier Field of View | 4″ / 6″ |
| Spatial Resolution | 80 lp/cm |
| Camera Resolution | 752 × 480 pixels |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥6 parts per minute (at non-tab corner regions) |
| False Positive Rate | ≤2% |
| False Negative Rate | 0.0% |
| Pass Rate Consistency | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (compliant with international radiation safety standards) |
| Brand | Astroda |
|---|---|
| Model | XG5300/XG5310 |
| X-ray Tube Voltage | 90 kV |
| X-ray Tube Current | 200 µA (software-limited to 89 µA) |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air Cooling |
| Field of View | 2″ / 4″ |
| Spatial Resolution | 75 / 110 lp/cm |
| X-CCD Resolution | 1024 × 1024 pixels |
| Repeatability Accuracy | ±40 µm |
| Throughput | ≥60 PPM |
| False Positive Rate | ≤2% |
| False Negative Rate | 0.0% |
| Overall Yield Rate | ≥99.5% |
| Radiation Dose Rate | ≤1 µSv/hr (at any accessible surface) |
| Host Dimensions | 2500 × 1500 × 1700 mm |
| Power Supply | AC 380 V, 50 Hz |
| Operating Environment | 23 ±5 °C, ≤80% RH |
| Display | 22″ widescreen LCD |
| CPU | Intel Core i3 |
| RAM | 2 GB |
| Storage | 500 GB HDD |
| Brand | Astroda |
|---|---|
| Model | XG5600 |
| Origin | Guangdong, China |
| Detector Type | Flat-Panel Digital Radiography System |
| Max. Tube Voltage | 110 kV |
| Max. Tube Current | 450 µA |
| Focal Spot Size | 5 µm |
| Cooling Method | Forced Air |
| Detector Active Area | 54 mm × 48 mm |
| Spatial Resolution | 20.8 lp/mm |
| Pixel Matrix | 2000 × 2249 / 1000 × 1124 |
| Repeatability Accuracy | ±60 µm |
| Throughput | ≥50 ppm |
| False Positive Rate | ≤2% |
| False Negative Rate | 0.0% |
| Pass Rate Consistency | ≥99.5% |
| Radiation Leakage | ≤1 µSv/hr (measured at 5 cm from enclosure surface) |
| Compliance | IEC 61000-6-3, IEC 61000-6-4, GBZ 126-2011, ANSI N43.3 |
| Brand | ATAC |
|---|---|
| Origin | United Kingdom |
| Model | REL0230 |
| Temperature Range | Ambient to 230 °C (no cooling) |
| Sample Volume | 0.2 mL |
| Compliance | BS EN ISO 2884-1:2006 |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 5–900 rpm (integer steps) |
| Viscosity Accuracy | ±2% of full scale (calibrated with standard oils) |
| Display | 4.3″ color LCD |
| Data Interface | USB |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Dimensions (H×W×D) | 510 × 302 × 302 mm |
| Weight | 13.0 kg |
| Brand | ATAC |
|---|---|
| Origin | United Kingdom |
| Model | REL0100 |
| Instrument Type | Cone-Plate Rotational Viscometer |
| Temperature Range | 10 °C to 100 °C |
| Sample Volume | 0.2 mL |
| Compliance | BS EN ISO 2884-1:2006 |
| Full-Scale Accuracy | ±2% (calibrated with standard oils) |
| Speed Range | 5–900 rpm (integer steps) |
| Low-Speed Mode | 5–90 rpm (0.1 rpm increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Display | 4.3-inch color LCD |
| Data Interface | USB |
| Power Supply | 100–240 V AC, 50/60 Hz, 150 W |
| Dimensions (H×W×D) | 510 × 302 × 302 mm |
| Weight | 13.5 kg |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | REL0100 / REL0230 |
| Viscosity Range | 0.1 Pa·s to 1 × 10⁶ Pa·s (typical for rotational viscometry with coaxial cylinder geometry) |
| Speed Range | 5–900 rpm |
| Temperature Range (REL0100) | 10–100 °C |
| Temperature Range (REL0230) | 25–230 °C |
| Compliance | BS EN ISO 2884-1:2006 |
| Units | °C/°F, rpm/s⁻¹, Poise/Pa·s |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Warm-up Time | 10 min |
| Dimensions (H×W×D) | 510 × 302 × 302 mm |
| Weight | 13.5 kg (REL0100), 13.0 kg (REL0230) |
| Brand | ATAC |
|---|---|
| Origin | United Kingdom |
| Model | REL0150 |
| Instrument Type | Oscillatory Cone-Plate Viscometer |
| Portability | Portable |
| Operating Environment | Ambient Temperature |
| Display | 4.3-inch Color LCD |
| Speed Range | 5–900 rpm (Low-Speed Mode: 5–90 rpm, Adjustable in 0.1-rpm Increments) |
| Accuracy | ±1% (Calibrated with Standard Reference Oils) |
| Compliance | BS EN ISO 2884-1:2006 |
| Cone Options | Six Interchangeable Cones |
| Calibration | Onboard Auto-Calibration for Multiple Cone Geometries |
| Connectivity | PC Interface via USB/RS-232 for Data Acquisition and Analysis |
| Software Features | Real-Time Shear Rate vs. Time Plotting, Multi-Format Data Export (CSV, TXT, XLS), Temperature-Compensated Viscosity Readout, Unit Selection (mPa·s, cP, Pa·s) |
| Brand | ATAC |
|---|---|
| Origin | United Kingdom |
| Model | REL0250 |
| Instrument Type | High-Temperature Portable Cone-Plate Viscometer |
| Speed Range | 5–900 rpm (Low-Speed Mode: 5–90 rpm, Adjustable in 0.1-rpm Increments) |
| Display | 4.3-inch Color LCD |
| Calibration | Onboard Auto-Calibration for Multiple Cone-Plate Geometries |
| Cone Options | Six Standard Cone-Plate Sets Available |
| Accuracy | ±1% (Verified with NIST-Traceable Standard Oils) |
| Compliance | BS EN ISO 2884-1:2006 |
| Temperature Capability | High-Temperature Operation (Compatible with External Heated Sample Chambers or Integrated Thermal Control Systems) |
| Connectivity | RS-232/USB PC Interface with Dedicated Data Acquisition Software |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AP-300 |
| Price | USD 17,200 (FOB Yokohama) |
| Measurement Range | Optical Rotation (AR): −89.999° to +89.999° |
| International Sugar Scale (ISS) | −99.99 to +99.99° |
| Resolution | AR: 0.0001° |
| ISS | 0.001° |
| Accuracy | ±0.002° (optical rotation), equivalent to ±0.2% of full scale for ISS |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-800α Series |
| Measurement Principle | Critical Angle Refractometry |
| Measuring Range (Brix) | 0.00–80.0% |
| Temperature Range | −15 to 160°C |
| Brix Resolution | 0.01% (0.00–9.99%), 0.1% (10.0–80.0) |
| Brix Accuracy | ±0.1% |
| Temperature Accuracy | ±1°C |
| Temperature Compensation Range | 5–100°C |
| Output Signals | DC 4–20 mA & RS-232C |
| Prism Material | Synthetic Sapphire |
| Prism Cell Material | SUS316L Stainless Steel |
| Response Time | ~1 second |
| Power Supply | DC 24 V (optional AC 100 V with AD-32 adapter) |
| Enclosure Rating | IP67 |
| Dimensions (H×W×D) | 160 × 167 × 110 mm |
| Weight | 2.4 kg (main unit only) |
| Optional Configurations | CM-800α-EG (ethylene glycol), CM-800α-PG (propylene glycol), CM-800α-SW (brine) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | CM-BASEα Series |
| Measurement Principle | Digital Refractometry (Critical Angle Method) |
| Temperature Compensation | Automatic (ATC) |
| Output Interface | 4–20 mA, RS-485 (Modbus RTU), Optional Analog Voltage |
| Process Connection | Clamp-type or Flanged Flow Cell (DIN/ISO Standard) |
| Operating Temperature Range | −15 to +160 °C |
| IP Rating | IP65 (Sensor Head), IP67 (Electronics Enclosure) |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | DOM-24 (9341) + AOM-03 Test Strips (9351) |
| Measurement Range | TPM 0.5–40% |
| Temperature Display Range | 0–225°C (32–437°F) |
| Temperature Accuracy | ±2.0°C (20–190°C), ±3.0°C (full range) |
| TPM Resolution | 0.5% |
| AV Resolution | 0.01 |
| TPM Accuracy | ±2.0% (20–190°C), ±3.0% (full range) |
| Measurement Method | Immersion-based electrochemical/optical strip assay |
| Temperature Compensation | Automatic digital compensation |
| Data Interface | NFC-enabled wireless transfer to iOS/Android devices |
| Compliance | Designed for routine QC in food service, compliant with JIS Z 8401 and ISO 8655-6 principles for volumetric accuracy of test strip readers |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-1 |
| Measurement Range | 0.0–53.0% Brix |
| Temperature Compensation | Automatic (ATC) |
| Display | LCD with digital readout |
| Sample Volume | Approx. 0.3 mL |
| Measurement Time | ~3 seconds |
| Calibration | Single-point using distilled water or standard sucrose solution |
| Compliance | Designed per JIS K 0064 and ISO 2173 for refractometric Brix determination |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PAL-EC DEC-2 Series |
| Price Range | USD 310 – 440 (FOB) |
| Measurement Range | 0–19.9 mS/cm |
| Resolution | 0.1 mS/cm |
| Accuracy | ±0.2 mS/cm |
| Measurement Method | Drop-in (Contact Electrode) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-HIKARI 10 (Peach-Specific) |
| Measurement Principle | Near-Infrared Absorption at ~940 nm |
| Measurement Range | Brix 8.0–20.0% |
| Temperature Range | 5.0–35.0°C |
| Brix Resolution | 0.1% |
| Temperature Resolution | 0.1°C |
| Brix Accuracy | ±1.5% (Brix), ±1.0°C (Temperature) |
| IP Rating | IP64 |
| Power | 2×AAA Alkaline Batteries |
| Dimensions | 6.1 × 4.4 × 11.5 cm |
| Weight | 120 g (main unit only) |
| Automatic Temperature Compensation | 5.0–35.0°C |
| Data Offset Correction Function | Yes |
| Sample Interface | Contact-type optical probe with integrated temperature sensor |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PAL-HIKARi 15 |
| Pricing | Available Upon Request |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-HIKARi Ripeness |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Measurement Range | Maturity 0–100% (unitless index), Temperature 5.0–35.0 °C |
| Resolution | Maturity 1%, Temperature 0.1 °C |
| Accuracy | ±5% for maturity (varies by fruit species and measurement conditions), ±1 °C for temperature |
| Auto Temperature Compensation | 5.0–35.0 °C |
| Power Supply | 2 × AAA alkaline batteries |
| Ingress Protection Rating | IP64 |
| Dimensions | 6.1 × 4.4 × 11.5 cm |
| Weight | 120 g (instrument only) |
| Data Storage | Up to 100 measurements |
| Data Transfer | NFC-enabled (to smartphones or PCs) |
| Sample Interface | Contact-type optical sensor with light-shielding gasket |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | PAL-pH |
| Price | USD 495 (FOB Yokohama) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.10 |
| Temperature Compensation Range | 10.0–40.0 °C (ATC) |
| Temperature Accuracy | ±0.5 °C |
| Sensor Type | Flat-Surface Glass Electrode with Integrated Reference System |
| Power Supply | 2 × AAA Alkaline Batteries |
| Dimensions | 55 × 31 × 109 mm |
| Weight | 100 g (instrument only) |
| Connectivity | NFC (Android-compatible only) |
| Compliance | CE, RoHS, ISO/IEC 17025 traceable calibration protocols |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PRM-100a |
| Refractive Index Range (nD) | 1.32000–1.55700 |
| Resolution (nD) | 0.0001 or 0.00001 |
| Accuracy (nD) | ±0.00010 |
| Temperature Display Range | 5.0–100.0 °C |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PRM-2000α |
| Refractive Index (nD) Range | 1.32069–1.36500 |
| Resolution | nD: 0.00001 |
| Accuracy | ±0.00001 (1.32069–1.33681), ±0.00010 (1.33682–1.36500) |
| Temperature Display Range | −35.0 to 165.0 °C |
| Brix Range | 0.000–20.000 % |
| Brix Accuracy | ±0.007 % (0.000–2.000 %), ±0.050 % (2.001–20.000 %) |
| Output | 4–20 mA, RS-232C |
| IP Rating | IP67 |
| Pressure Rating | 1.0 MPa |
| Prism Material | Sapphire |
| Wetted Parts | SUS316L |
| Light Source | LED (≈589 nm, D-line equivalent) |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | RePo™-1 / RePo™-3 / RePo™-4 / RePo™-5 |
| Measurement Range (AR) | –130° to +130° |
| Resolution (AR) | 0.01° |
| Accuracy (AR) | ±0.10° |
| Light Source | LED @ 589 nm (D-line equivalent) |
| Temperature Range | 10.0–40.0 °C |
| IP Rating | IP67 |
| Dimensions | 10.1 × 16.0 × 3.8 cm |
| Weight | 325 g (host unit only) |
| Power | 4 × AAA alkaline batteries |
| Measurement Time | 12 s |
| Brix Range | 0.0–85.0 % |
| Refractive Index Range (RePo™-5) | 1.3306–1.5050 |
| RI Resolution | 0.0001 (at 20 °C) |
| RI Accuracy | ±0.0002 (at 20 °C) |
| Compliance | USP <788>, EP 2.2.42, JP XVII, ISO 21543, ASTM D1218, ASTM E1222 |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | SAC-i Series |
| Measurement Range | AR: -89.9999° to +90.0000° |
| Resolution | AR: 0.0001°, lSS: 0.001 |
| Accuracy | ±0.002° |
| Wavelengths | 589 nm & 882 nm |
| Compliance | ICUMSA, Japanese Pharmacopoeia (JP), FDA 21 CFR Part 11, GLP/GMP-ready |
| Data Storage | Up to 5,000 measurements with zeroing/calibration history |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | TANK(CM) Series |
| Type | In-line Process Refractometer |
| Measurement Principle | Critical Angle Refractometry |
| Output Signal | 4–20 mA / RS-485 (Modbus RTU) |
| Process Connection | Clamp, Flange, or Threaded (DIN/ISO/JIS compliant) |
| Housing Material | SS316L |
| IP Rating | IP67 |
| Operating Temperature | −10 to 80 °C (process fluid) |
| Brix Range | 0–95% w/w |
| Resolution | 0.01% Brix |
| Repeatability | ±0.02% Brix |
| Calibration | Single-point or multi-point via software |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | 6811 |
| Instrument Type | Benchtop Viscometer |
| Viscosity Range | 1–2,000 mPa·s (with ULA adapter) |
| Torque Range | 0.0–100.0% (recommended: 10.0–100.0%) |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Rotational Speed | 0.5–250 rpm (20 discrete steps) |
| Viscosity Resolution | 0.01 mPa·s (≤100 mPa·s), 0.1 mPa·s (100–10,000 mPa·s), 1 mPa·s (>10,000 mPa·s) |
| Viscosity Accuracy | ±1% of full scale |
| Power Supply | 4 × AA alkaline batteries (DC 6 V) or AC adapter (100–240 V AC) |
| Battery Life | ~7 hours (continuous operation at 60 rpm) |
| Data Interface | USB to PC |
| Operating Environment | 10–40 °C ambient, 10–40 °C sample temperature |
| Compliance | Designed for ISO 2555 and ASTM D2196-compliant viscosity measurement workflows |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Instrument Type | Benchtop Rotational Viscometer |
| Model | VISCO (Ultra-Low-Viscosity Configuration) |
| Viscosity Range | 1–2,000 mPa·s |
| Temperature Accuracy | ±0.2°C |
| Operating Temperature Range | 10.0–40.0°C (Sample), 10–40°C (Ambient) |
| Speed Range | 0.5–250 rpm (20 discrete steps) |
| Torque Display Range | 0.0–100.0% (Recommended: 10.0–100.0%) |
| Temperature Display Range | 0.0–100.0°C / 32.0–212.0°F |
| Resolution | Viscosity — 0.01 mPa·s (≤100), 0.1 mPa·s (100–10,000), 1 mPa·s (>10,000) |
| Viscosity Accuracy | ±1% of full scale |
| Power Supply | DC 6V (4 × AA alkaline batteries) or AC adapter (100–240 V AC) |
| Battery Life | ~7 hours (continuous operation at 60 rpm) |
| Data Interface | USB to PC |
| Compliance | Designed for GLP-compliant viscosity testing in QC and R&D environments |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | VISCO B (L) |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 12–600,000 mPa·s |
| Operating Environment | Ambient Temperature |
| Host Unit | VISCO Viscometer Base Unit |
| Compliance | Designed for ISO 2555 & ASTM D2196 compliant viscosity measurement |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | VISCO B(L) |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 50–60,000,000 mPa·s |
| Temperature Control Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Measurement Principle | Coaxial Cylinder (Couette Flow) Rheology |
| Compliance | Designed for ISO 2555, ASTM D2196, and USP <911> viscosity testing protocols |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | VISCO B(L) |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 12 – 60,000,000 mPa·s |
| Temperature Range | 5.0 – 90.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Speed Range | 0.01 – 250 rpm (28 selectable speeds) |
| Torque Display | 0.0 – 100.0% (recommended operating range: 10.0 – 100.0%) |
| Power Supply | 4 × LR6/AA alkaline batteries or AC adapter |
| Dimensions (H×W×D) | 194 × 178 × 86 mm |
| Weight | 1.2 kg |
| Standard Spindles | L1, L2, L3, L4 |
| Viscosity Accuracy | ±1% of full-scale reading at maximum measurable viscosity |