Physical Property Testing Instruments
Filter
Showing 871–900 of 4355 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution Scientific CMOS Sensor |
| Scan Mode | Translation-Rotation (TR) |
| Spatial Resolution | 2 µm |
| Density Resolution | <1% |
| X-ray Energy | 110 kV |
| Maximum Sample Dimensions | Ø110 mm × 300 mm (H) |
| Max Sample Weight | 5 kg |
| System Footprint | 1250 × 960 × 690 mm (L × D × H) |
| Precision Level | Nanoscale |
| Configuration | Modular Benchtop Micro-CT Platform |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X4 POSEIDON |
| Detector Type | High-Resolution sCMOS Semiconductor Sensor |
| Scanning Mode | Translation-Rotation (TR) |
| Spatial Resolution | ≤2 µm (JIMA-verified) |
| System Architecture | Modular, Field-Upgradable |
| Brand | Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 630 (FOB) |
| Standards Compliance | ISO 2759, ASTM D2210, TAPPI T403, GB/T 6545, JIS L1004/L1018/L1031, QB/T 1057 |
| Test Principle | Hydraulic (Silicone Oil-Based) Diaphragm Bursting |
| Clamping Method | Pneumatic Dual-Plate Clamp |
| Display | High-Resolution LCD with Onboard Data Storage (50 Tests) |
| Output | Integrated Thermal Printer |
| Safety | Emergency Stop Button, Real-Time Air Pressure Gauge |
| Sample Thickness Range | Up to 18 mm |
| Repeatability | ≤±2.0% (per ISO 2759 Annex B) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 630 (FOB) |
| Standards Compliance | ISO 2759, ASTM D2210, TAPPI T403, GB/T 6545, JIS L1004/L1018/L1031, QB/T 1057 |
| Brand | A2PS/A2 Photonic Sensors |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | BUZZ-1015 |
| Pricing | Upon Request |
| Measurement Principle | Impulse Excitation / Laser Doppler Vibrometry |
| Frequency Range | 0.5 Hz – 2.5 MHz |
| Accuracy | Better than ±1.0% (resonance frequency), ±0.1% typical for fundamental mode identification |
| Test Duration | Seconds per measurement |
| Damping Factor Range | 10⁻⁵ – 10⁻¹ |
| Sample Dimensions | ≤ 200 × 180 × 180 mm (rectangular or cylindrical) |
| Temperature Range | Ambient to 1500 °C (protection limit) |
| Vacuum Level | < 1 × 10⁻² Pa (operational), < 5 × 10⁻⁸ Torr (base pressure) |
| Compliant Standards | ASTM C1259, ASTM E1876, ISO 12680 |
| Brand | C&W |
|---|---|
| Origin | Netherlands |
| Model | CW Series Cyclic Corrosion Test Chamber |
| External Dimensions (L×W×H) | 1000×600×645 mm to 2750×1220×1630 mm |
| Internal Dimensions (L×W×H¹×H²) | 600×450×375×565 mm to 2000×1000×850×1175 mm |
| Power Supply | Single-phase or three-phase 380 V, 50/60 Hz |
| Compressed Air Requirement | Oil-free, dry, clean air |
| Humidity Range | 15% to 98% RH (controlled) |
| Temperature Control | Integrated refrigeration compressor system (continuous or standby operation) |
| Optional Features | Deionizer & sediment filter (recommended for water with >50 mg/L TDS), low-water-level alarm, external salt fog collection vessel, condensate-controlled fog generation, variable ventilation, ergonomic control panel, GRP composite enclosure with chemical/thermal resistance, pneumatic lid support, modular sample mounting fixtures |
| Brand | C&W |
|---|---|
| Origin | Netherlands |
| Model | CW1001–CW1020 Series |
| Internal Volume | 100 L to 2000 L |
| External Dimensions (L×W×H) | 1000×600×645 mm to 2750×1220×1630 mm |
| Internal Dimensions (L×W×H¹×H²) | 600×450×375×565 mm to 2000×1000×850×1175 mm |
| Power Supply | 13–32 A, Single- or Three-Phase 230/380 V, 50/60 Hz |
| Compressed Air Requirement | Oil-free, dry, filtered |
| Pressure | 2–4 bar (30–60 psi) for spray generation |
| Temperature Range | 30–80 °C (chamber), ±1 °C accuracy |
| Saturated Air Tower | 65 °C ±1 °C, NiCr heating element with overheat protection and auto-refill humidifier |
| Salt Solution Reservoir | 114 L mobile external tank, integrated filtration, ~14 days continuous operation |
| Control System | Microprocessor-based, 7 programmable test methods, cycle timer with remaining count, spray/dry/purge sequencing |
| Optional | Low-level alarm, ergonomic control panel, GRP corrosion-resistant chamber body, insulated apex lid with gas spring support |
| Compliance | Designed to meet ASTM B117, ISO 9227, JIS Z2241, DIN 50021 requirements |
| Brand | C&W |
|---|---|
| Origin | Netherlands |
| Model | CW1001 |
| Spray Method | Direct Air-Atomized Nozzle |
| Fog Output Rate | 1–2 mL/h |
| Nozzle Operating Pressure | 8.44 kg/cm² (≈120 psi) |
| Fog Collection Rate | 1–2 mL per 80 cm² per hour |
| Temperature Range | Ambient to 55 °C |
| Compliance | ASTM B117, ISO 9227, EN ISO 7253, DIN 50021, JIS Z 2371, SAE J2334, Ford CETP, GMW 14872, VW PV1210, BMW GS 90031, Renault D17 2025, etc. |
| Brand | Caikon Optical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GCK-HD |
| Price | USD 4,900 (approx.) |
| Probe Diameter | 1.9–10 mm |
| Working Length | 54–600+ mm |
| Viewing Angle | 0°, 30°, 45°, 70°, or 90° (selectable) |
| Field of View | >70° |
| Imaging Sensor | Sony 1/1.8" CMOS |
| Resolution | 1920 × 1080 (2 MP) |
| Frame Rate | 60 fps |
| Output Interfaces | HDMI, VGA, DVI |
| Image Format | JPEG |
| Video Format | MKV, AVI |
| Storage | SD card |
| Illumination Options | Benchtop cold light source (XD-303), portable waist-mounted (KD-202), handheld LED (CK-202B), or desktop halogen (XD-301) |
| Operating Temperature | −10 °C to +50 °C |
| Key | Temperature Range: −40 °C to +150 °C (optional −120 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 Color LCD Touchscreen Controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | BlackGlobe-L |
| Operating Temperature Range | -50 °C to 100 °C |
| Measurement Range | -5 °C to 95 °C |
| Interchangeability Error | < ±0.2 °C (0–70 °C) |
| Polynomial Linearity Error | ±0.5 °C (-7 °C to 90 °C) |
| Maximum Cable Length | 305 m |
| Compatibility | All Campbell Scientific dataloggers except CR200X series |
| Sensor Type | Black Globe Thermometer for WBGT Index Calculation |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CAV4.1 |
| Instrument Type | Capillary Viscometer (Fixed Benchtop) |
| Kinematic Viscosity Range | 0.5–10,000 mm²/s (cSt) |
| Temperature Range | 20–150 °C |
| Temperature Resolution & Accuracy | ±0.01 °C |
| Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105, IP 71, GB/T 265 |
| Sample Throughput | Dual-capillary parallel measurement |
| Integrated Control | Built-in industrial PC + 10.4″ color touchscreen |
| Software | VISCPRO (supports up to 4 CAV4.1 units per host PC) |
| Cleaning & Drying | Automated solvent rinse and compressed-air drying |
| Capillary Exchange | Tool-free, bath-oil–retaining design |
| Calibration | Single-point temperature calibration per capillary |
| Status Indication | Multi-color LED status lighting |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CAV4.2 |
| Instrument Type | Fixed-Position Capillary Viscometer |
| Viscosity Range | 0.5–10,000 cSt |
| Temperature Range | 15–150 °C |
| Temperature Resolution | ±0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Compliance | CE Certified |
| Sample Throughput | Up to 24 samples unattended (1-hour cycle) |
| Display | 10.4-inch color touchscreen |
| Solvent Consumption Reduction | ~50% vs. conventional capillary systems |
| Cleaning Method | Automated air purge and solvent rinse |
| Capillary Options | Ubbelohde or ATLANTA-type viscometers |
| Calibration | Single-point temperature calibration per capillary |
| Sample Preheating | Individual sample heating up to 100 °C |
| Operating Environment | Ambient laboratory conditions |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CCS-2100F |
| Instrument Type | Rotational Viscometer (Cold Cranking Simulator) |
| Temperature Range | −35 °C to −5 °C |
| Temperature Resolution & Accuracy | ±0.05 °C |
| Apparent Viscosity Range | 1,500–27,000 mPa·s |
| Compliance | ASTM D5293, SAE J300-99, GB/T 6538 |
| Cooling Method | Solid-State Thermoelectric (No Refrigerants) |
| Sample Throughput | 30 Samples per Unattended Run |
| Control System | Windows-Based PC with CCS-RA Interface and LIMS-Ready Software |
| Power Supply | 230 V / 50 Hz / 1000 W |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CCS-2100LT |
| Instrument Type | Rotational Viscometer (Fixed-Base, Cold-Bath Configuration) |
| Temperature Range | −5 °C to −40 °C |
| Temperature Resolution & Accuracy | ±0.05 °C |
| Apparent Viscosity Range | 1500 mPa·s to 21000 mPa·s |
| Cooling Method | Solid-State Thermoelectric (Peltier) |
| Compliance | ASTM D5293, SAE J300-99, GB/T 6538 |
| Sample Throughput | Up to 30 samples per automated sequence |
| Control & Data Handling | PC-based automation with self-calibration routines and integrated wash cycle with programmable heating profile |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CCS2100-G6 |
| Instrument Type | Rotational Viscometer (Fixed-Base, Low-Temperature CCS) |
| Temperature Range | −40 °C to −5 °C |
| Temperature Accuracy | ±0.05 °C |
| Temperature Resolution | ±0.05 °C |
| Viscosity Range | 900–25,000 mPa·s (cP) |
| Compliance | ASTM D5293, SAE J300, GB/T 6538 |
| Sample Capacity | 14 samples (unattended) |
| Cleaning Method | Solvent-Free In-Situ Sample Flush |
| Calibration | Auto-Rotational Speed Calibration & User-Verifiable Temperature Calibration |
| Software | FlowHub™ Data Management Platform |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CMRV-4500F |
| Instrument Type | Rotational Viscometer (Fixed-Mount) |
| Temperature Range | –5 °C to –40 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling Method | Thermoelectric (Peltier) with Fluorine-Free Coolant Circulation |
| Compliance | ASTM D3829, D4684, D6896, D6821, SAE J300, GB/T 9171, SH/T 0562 |
| Software Platform | Windows 98/NT/XP Compatible Control System |
| Optional Accessory | Dedicated Rotor Kit for ASTM D6821 |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CT-2000 |
| Temperature Control Range | 20 °C to 150 °C |
| Temperature Stability | ±0.01 °C |
| Compliance | ASTM D445, ISO 3104 |
| Communication Interfaces | RS-232, RS-485 |
| Bath Capacity | 7 × 51 mm viscometer ports + 2 auxiliary thermometer ports |
| Display | 4-line LCD with digital setpoint & actual temperature readout |
| Input Method | Keypad entry of two-digit decimal setpoints |
| Temperature Unit Toggle | °C / °F |
| Self-Diagnostic Function | Power-on system check |
| Calibration Offset Entry | Manual mercury thermometer correction via keypad |
| Cooling Option | External tap water or chiller connection |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CT-2000F |
| Instrument Type | Fixed-Position Constant-Temperature Bath |
| Application | Capillary Viscometry |
| Temperature Range | 10 °C to 100 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Bath Capacity | 17 L |
| Power Supply | 240 V, 50/60 Hz, 1400 W |
| Dimensions (W×D×H) | 438 mm × 464 mm × 584 mm |
| Net Weight | 51.4 kg |
| Compliance | ASTM D445, ISO 3104 |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | DVR-1000 |
| Instrument Type | Fixed-Position Vacuum Viscometer |
| Operating Temperature Range | 0–40 °C |
| Vacuum Accuracy | ±0.5 mmHg at 300 mmHg setpoint |
| Compliance | ASTM D2171 |
| Display | Digital LED |
| Control Interface | Front-panel membrane keypad |
| Sensing Element | Solid-state pressure transducer (mercury-free) |
| Application Focus | Bitumen and asphalt viscosity testing under controlled vacuum |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | HTHS-II |
| Instrument Type | Capillary Viscometer |
| Standards Compliance | ASTM D5481, SAE J300, SH/T 0703-2001 |
| Operating Temperature | 150 °C |
| Shear Rate | 1.4 × 10⁶ s⁻¹ |
| Sample Throughput | 15–20 samples/hour |
| Safety Features | Inlet valve interlock, overtemperature cutoff |
| Software | Windows-based HTHS viscosity calculation software |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniAV |
| Instrument Type | Capillary Viscometer (Fixed-Station, Benchtop) |
| Viscosity Range | 0.5–10,000 mm²/s (cSt) |
| Temperature Range | 15–100 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C (at setpoint) |
| Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105 |
| Sample Volume | 5–10 mL per test |
| Bath Volume | 1 L |
| Dimensions | 254 mm (W) × 533 mm (H) × 381 mm (D) |
| Connectivity | RS-232 |
| Software | VISCPRO II (Windows 98/NT/XP compatible) |
| Multi-unit Control | Up to 4 units per PC |
| LIMS Integration | Yes |
| Operating Humidity | 10–90% RH (non-condensing) |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniAV-LT |
| Instrument Type | Capillary Viscometer (Fixed-Station) |
| Kinematic Viscosity Range | up to 20,000 mm²/s |
| Temperature Range | −40 °C to +30 °C |
| Temperature Stability | ±0.05 °C |
| Compliance | ASTM D445, D1655, D2532, ISO 3104, ISO 3105, IP 71, DEF STAN 91-91, GB/T 265 |
| Cooling Method | Integrated Peltier Thermoelectric System with Air–Water Heat Exchange |
| Sample Volume | ~6 mL |
| Cleaning & Drying | Automated solvent rinse and thermal drying at +30 °C |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniPV |
| Instrument Type | Capillary Viscometer (Fixed-Station) |
| Viscosity Range | 0.3–20,000 cSt |
| Temperature Range | 15–100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Accuracy | ±0.01 °C |
| Sample Volume | ~15 mL |
| Flow Time Resolution | 0.01 s |
| Cooling Method | Peltier-based (no external chiller required) |
| Sample Capacity | 10-position auto-sampler |
| Cleaning System | Dual-solvent + compressed air drying |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniPV-HX |
| Instrument Type | Capillary Viscometer (Ubbelohde-type, modified) |
| Mounting | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.3–1,200 mm²/s (cSt) |
| Temperature Range | 15–100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Accuracy | ±0.01 °C |
| Flow Time Resolution | 0.01 s |
| Sample Volume | ~15 mL |
| Sample Capacity | 10-position autosampler |
| Cleaning | Dual-solvent rinse + compressed-air drying |
| Thermal Control | Peltier-based cooling/heating (no external chiller required) |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniQV-X |
| Instrument Type | Fixed-Position Capillary Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.5–10,000 mm²/s |
| Compliance | ASTM D445 |
| Sample Throughput | <3 min per sample |
| Automation | 25-position Rotating Autosampler with Integrated Cleaning & Drying |
| Configuration | Sample-to-Sample Mode |
| Category | Physical Property Testing Instrument / Capillary Viscometer |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | PolyVISC |
| Instrument Type | Capillary Viscometer |
| Temperature Range | 20–100 °C (optional 135 °C) |
| Temperature Stability | ±0.01 °C |
| Efflux Time Resolution | ±0.01 s |
| Viscosity Range | 0.3–20,000 cSt |
| Solvent Compatibility | Broad (including chlorinated, phenolic, and high-boiling solvents) |
| Compliance | ASTM D2857, ASTM D4603, ISO 307, USP <911>, FDA 21 CFR Part 11 (audit trail enabled in VISCPRO) |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | Ravenfield BS/C+ HTHS Viscometer |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Viscosity Range | 0–30 cP |
| Temperature Range | 40 °C to 180 °C |
| Temperature Resolution & Accuracy | ±0.02 °C |
| Shear Rate Range | 1×10⁵ s⁻¹ to 2×10⁶ s⁻¹ |
| Test Cycle Time | <5 min per sample |
| Repeatability | ≤2% RSD |
| Compliance | ASTM D4741, ASTM D4683 (correlative), SAE J300, ACEA Specifications |
| Optional Accessories | DR-Series Automated Sampler (up to 22 samples), LIMS Interface Module, Integrated Thermal Printer |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TE-1500F / TE-3000F |
| Instrument Type | Fixed-Position Capillary Viscometer |
| Operating Environment | Ambient Laboratory |
| Temperature Range | –30 °C to +10 °C (TE-1500F) / –30 °C to +30 °C (TE-3000F) |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Compliance | ASTM D445, ISO 3104, GB/T 265 |