Physical Property Testing Instruments
Filter
Showing 2011–2040 of 4517 results
| Brand | Instytut Fotonowy |
|---|---|
| Origin | Poland |
| Model | Electrochemical Kelvin Probe |
| Weight | 15 kg |
| Dimensions | 40 × 40 × 45 cm |
| Power Supply | 230 V, 50 Hz or 115 V, 60 Hz |
| PC Interface | USB 2.0 |
| Measurement Principle | Dual-channel lock-in amplifier-based vibrating capacitor method |
| Contact Potential Difference (CPD) Range | −5 to +5 V |
| CPD Resolution | 0.15 mV |
| Current Ranges | 300 nA / 30 nA / 3 nA / 300 pA |
| Probe Tip | Au mesh, 2.5 mm diameter |
| Vertical Positioning Resolution | 20 µm |
| Typical CPD Measurement Gap | 0.2–1 mm |
| XY Motorized Stage | 50 × 50 mm travel range |
| Faraday Cage | Standard airtight version with inert gas flow system |
| Electrochemical Cell | PTFE body, Kapton-insulated sample substrate, Ag/AgCl reference electrode option |
| Optical Access | Fused silica window, UV-enhanced mirror, liquid light guide for bottom illumination |
| Environmental Sensors | Integrated temperature and humidity monitoring |
| Laser Guidance System | Visible alignment laser with automatic gap-sensing barrier |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | IEC 60529, ISO 20653, SAE J575, GB/T 4208 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Origin Region | Netherlands |
| Model | IP2000 |
| Pricing | Upon Request |
| Standards Compliance | ISO 6272, ASTM D2794 |
| Optional Accessories | 1 kg and 2 kg Additional Weights |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| IP Rating Coverage | IPX5, IPX6, IPX7 |
| Compliance Standards | IEC 60529, ISO 20653, GB/T 4208, MIL-STD-810H Method 506.7, GJB 150.8A, IEC 60068-2-68, GB/T 2423.38, IEC 60034-5, GB/T 4942.1 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,500 (FOB) |
| Compliance | IPX5, IPX6 per IEC 60529, ISO 20653, GB/T 4208, MIL-STD-810G Method 512.6, ASTM D7706 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 3,500 (FOB) |
| Compliance Standards | IEC 60529, ISO 20653, GB/T 4208, GJB 150.8, IEC 60068-2-68, GB 2423.38 |
| Brand | Irian |
|---|---|
| Origin | France |
| Model | J2 |
| Pressure Range | 0–14,500 psi |
| Temperature Range | Ambient to 200 °C |
| Temperature Accuracy | ±0.3 °C |
| Pressure Uncertainty | ±1.5 psi |
| Cell Volume | 1.24 mL |
| Optical Imaging | Integrated HD Digital Camera |
| Actuation | Embedded Electromechanical Piston Pump with Automatic Valving |
| Gas Flow Control | Micro-Flow Regulating Valve |
| Cell Tilt | 0–45° |
| Dimensions | 610 mm × 559 mm × 203 mm (L×W×H) |
| Cooling | High-Capacity Forced-Air System |
| Agitation | Electromagnetic Vibration Module |
| [Brand | Isida |
|---|---|
| Origin | Guangdong, China |
| Model | XK22 |
| Resolution | 0.70–5.20 µm/pixel |
| Optical Magnification | 1.4×–9× (continuously adjustable) |
| Electronic Magnification | 50× |
| Light Source | Adjustable LED ring light + red laser diode (LD) positioning |
| CCD | High-sensitivity color CCD |
| Maximum PCB width | 780 mm (30") |
| Field of View | 3.4 mm × 2.5 mm to 0.53 mm × 0.4 mm |
| Repeatability | ±1 µm |
| Dimensions (L×W×H, instrument only) | 960 mm × 700 mm × 1220 mm |
| Weight (instrument only) | 145 kg |
| Power | 220 V ±10%, 50 Hz, 10 A |
| Operating Temperature | 0–40 °C] |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ISO 9150 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ISO 9151 |
| Pricing | Available Upon Request |
| Brand | HG |
|---|---|
| Origin | Japan |
| Model | MIV-X |
| Detection Principle | Ultrasonic Excitation + Stroboscopic Laser Imaging |
| Surface Displacement Resolution | Sub-micron (optical) |
| Effective Inspection Depth | Up to ~1 mm |
| Sample Interface Compatibility | Bonded interfaces, thermal spray coatings, paint layers, composite laminates |
| Optional Accessory | Motorized Optical Zoom Lens Assembly |
| Regulatory Context | Designed for R&D and QC environments compliant with ISO 16840 (Ultrasonic Testing — Characterization of ultrasonic testing equipment), ASTM E2700 (Standard Guide for Acoustic Emission Examination of Fiber Reinforced Polymer Matrix Composites), and GLP-aligned data traceability |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-319B |
| Origin | Shanghai, China |
| Applicable Standard | GB/T 8333–2008 |
| Burner Inner Diameter | Φ9.5 ± 0.5 mm |
| Burner Length | 102 mm |
| Adjustable Flame Height | 20–175 mm |
| Maximum Flame Temperature | 1100 °C (Bunsen burner flame at 960 °C ± 20 °C) |
| Timing Range | 0–99 min 99 sec (flame application & afterflame duration) |
| Gas Supply | Liquefied Petroleum Gas (LPG) or Town Gas |
| Air Adjustment Port | Integrated |
| Compliance | GB/T 8333–2008 (equivalent to ISO 5657:1997 for vertical flame propagation on rigid cellular plastics) |
| Warranty | 12-month parts and labor coverage |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-THP |
| Price | USD 12,500 (FOB Shanghai) |
| Type | Electromechanical Servo-Controlled Fatigue Testing System for Viscoelastic Energy Dissipation Components |
| Brand | JeioTech |
|---|---|
| Origin | South Korea |
| Model | TH-G-408 |
| Chamber Volume | 408 L |
| Temperature Range (dry) | −40 °C to +150 °C |
| Humidity Range | 25 %RH to 95 %RH |
| Temp. Uniformity (at 40 °C, 75 %RH) | ±0.5 °C |
| Temp. Stability (at 40 °C, 75 %RH) | ±0.3 °C |
| Humidity Stability (at 40 °C, 75 %RH) | ±0.4 %RH |
| Humidity Deviation (at 40 °C, 75 %RH) | ±3 %RH |
| Heating Rate | 2.6 °C/min |
| Internal Dimensions (W×D×H) | 600 × 850 × 800 mm |
| Standard Shelving | 2 adjustable stainless steel shelves (max. 10), load capacity per shelf: 25 kg, total payload: 65 kg |
| Water Tank Capacity | 15 L |
| Net Weight | 410 kg |
| Power Supply | 3-phase 380–415 VAC, 50/60 Hz |
| Compliance | DIN 12880, IEC 60068 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JF99H |
| Pricing | Available Upon Request |
| Measurement Principle | Washburn Capillary Rise Method |
| Pressure Range | 0–330 mbar |
| Pressure Resolution | 0.16 mbar |
| Temperature Range | Ambient to 200 °C (optional dual-zone electric heating control) |
| Contact Angle Range | 0–180° |
| Quartz Tube Dimensions | OD 10 mm / ID 8 mm or 6 mm |
| Instrument Dimensions | 295 × 240 × 260 mm |
| Power Supply | 220 V AC, 20 W |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH High-Temperature Thermal Aging Test Chamber |
| Temperature Range | −70 °C to +150 °C |
| Refrigeration Method | Compressor-Based Cooling |
| Explosion-Proof Design | Yes |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C (at working volume center) |
| Temperature Deviation | ±2.0 °C (vs. setpoint) |
| Heating Rate | ≤60 min (−70 °C to +150 °C) |
| Cooling Rate | ≤45–80 min (depending on configuration and load) |
| Interior Dimensions | Customizable (small / medium / large chamber variants available) |
| Shelving | Multi-tier adjustable stainless-steel shelves, fully customizable in number, height, and load capacity |
| Brand | JIAHANG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Wet-Dispersion Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01 µm – 2000 µm |
| Repeatability | <1% RSD (D50) |
| Measurement Time | ≤10 seconds per run |
| Dispersing Medium Volume | ≥180 mL (standard), optional 10 mL micro-circulation mode |
| Ultrasonic Power | 100 W with dry-run protection |
| Optical Alignment | Fully automated mechanical–optical dual-axis centering (≤15 s, 0.2 µm step resolution) |
| Detector Channels | 121 |
| Compliance | ISO 13320:2020, GB/T 19077–2016, USP <429>, FDA 21 CFR Part 11 ready (with audit trail, electronic signature, role-based access control) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | H-8925 (8820G) |
| Combustion Time Range | 0–99.99 s/min/h |
| Burner Nozzle Inner Diameter | 9.5 mm |
| Nozzle Center Position | 19 mm below free end center of specimen |
| Metal Hood Dimensions | 385 × 204 × 360 mm |
| Control Box Dimensions | 305 × 320 × 285 mm |
| Comb Comb Length | ≥110 mm |
| Steel Ruler Accuracy | ±1 mm |
| Fuel | Liquefied Petroleum Gas (LPG), user-supplied |
| Power Supply | 220 V AC, 50 Hz |
| Compliant Standards | GB 8410–2006, TL 1010, GM 6090M, DIN 75200, GM 9070P |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | JH-Series Laboratory Salt Spray Test Chamber |
| Price Range | USD 1,150 – 11,500 (FOB Shanghai) |
| Spray Method | Continuous Atomization |
| Spray Rate | 1–2 mL / 80 cm²·hr |
| Nozzle Pressure | 0.7–1.0 kgf/cm² |
| Fog Removal | Pneumatic Air-Compression Exhaust |
| Brand | JianHu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Ozone Aging Test Chamber |
| Temperature Range | Ambient to 70 °C |
| Ozone Concentration Range | 0–1000 pphm (adjustable with UV ozone generator) |
| Humidity Control | Optional RH 20–98% (±3% RH) |
| Chamber Volume | 100–1000 L (customizable) |
| Compliance | ISO 1431-1, ASTM D1149, GB/T 7762, IEC 60811-501 |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | JH-TC Series |
| Temperature Range | -70 °C to +150 °C |
| Refrigeration Method | Compressor-based |
| Explosion-Proof Design | Yes |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Deviation | ±2.0 °C |
| Heating Rate | ≤60 min (from −40 °C to +150 °C) |
| Cooling Rate | ≤45 min / ≤60 min / ≤80 min (depending on configuration) |
| Chamber Dimensions | Customizable (Small / Medium / Large) |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JH-OZ-XE Series |
| Price Range | USD 500 – 48,000 |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HP-TLY |
| Price Range | USD 1,400 – 7,200 (based on configuration) |
| Maximum Test Load | 10 kN (optional up to 100 kN) |
| Load Accuracy | ±1% |
| Minimum Load Resolution | 0.01 N |
| Minimum Displacement Resolution | 0.01 mm |
| Max Stroke (Tension/Compression) | 600 mm |
| Upper/Lower Platen Diameter | 200 mm |
| Crosshead Speed Range | 0.01–500 mm/min (multi-step adjustable) |
| Displacement Measurement Error | ≤ ±(50 + 0.15L) µm |
| Test Machine Class | Class 1 |
| Frame Type | Portal-type |
| Dimensions (W×D×H) | 720 × 500 × 1780 mm |
| Net Weight | 400 kg |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HP-ZRD-1000D |
| Measuring Range | 10–1000 mN |
| Test Speed | 10 mm/min |
| Specimen Dimensions | 100×50 mm, 100×80 mm, 100×100 mm |
| Accuracy Class | Class 1 |
| Indenter Thickness | 2 mm (±0.05 mm tolerance) |
| Force Resolution | 0.001 N |
| Clamp Jaw Width | 18 mm |
| Speed Adjustment | Digital DC motor, 1–1000 mm/min |
| Drive System | Arc-synchronous timing belt + precision ball screw |
| Display | Touchscreen LCD, full Chinese UI |
| Power Supply | 200 V, 50 Hz |
| Host Dimensions | 540 × 280 × 1450 mm |
| Weight | ~70 kg |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | HP307 |
| Force Range | 30–5000 N (0.05–4.0 MPa) |
| Force Resolution | 0.1 N |
| Force Accuracy | ±0.5% FS |
| Test Speed | 1–300 mm/min |
| Parallelism of Upper/Lower Platen | <0.025 mm |
| Platen Diameter | 120 mm |
| Dimensions (W×D×H) | 430×350×710 mm |
| Weight | 45 kg |
| Power Supply | 220 V, 50 Hz |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Wet-Dispersion Laser Particle Size Analyzer |
| Measurement Range | 0.1–300 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <120 s per run |
| Dispersion Method | Wet dispersion with integrated ultrasonication, stirring, and circulation |
| Laser Source | λ = 639 nm, P > 2 mW |
| Ultrasonic Frequency | 40 kHz, Power: 60 W (adjustable duration) |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL (optional 10 mL micro-cell) |
| Compliance | GB/T 19077–2016, ISO 13320:2009, Q/0100JWN001–2013 |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | Winner311XPPLUS |
| Price Range | USD 14,000–21,500 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–100 µm |
| Repeatability | >99% |
| Measurement Time | 10–120 s |