Physical Property Testing Instruments
Filter
Showing 2161–2190 of 4517 results
| Brand | OEM (Custom-Branded) |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (FOB) |
| Brand | Custom OEM / Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Capacity | 80 L |
| Internal Dimensions (H×W×D) | 400 × 500 × 400 mm |
| Temperature Range | −70 °C to +150 °C |
| Temperature Uniformity | ±0.5 °C |
| Heating System | Nickel-Chromium Alloy Wire Heater |
| Cooling System | Hermetic Compressor (Tecumseh or equivalent), Eco-Friendly Refrigerant |
| Insulation | Rigid Polyurethane Foam + Glass Wool |
| Interior Material | Mirror-Finish Stainless Steel (SUS304) |
| Exterior Material | Powder-Coated Steel or Stainless Steel |
| Air Circulation | Centrifugal Blower |
| Temperature Sensor | PT100 Dry-Bulb Sensor |
| Control Mode | Balanced Temperature Control (BTC) |
| Ramp Rate | Linear, −70 °C ↔ +150 °C in <90 min |
| Ambient Operating Condition | +5 °C to +35 °C |
| Power Supply | 2Φ 3W 220 VAC ±10% |
| Safety Protections | Compressor Overheat/Overcurrent/High-Pressure, Heater Dry-Burn Prevention, Chamber Over-Temperature Cut-off |
| Brand | OEM / Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (FOB) |
| Temperature Range | -70°C to +180°C |
| Ramp Rate | Up to 15°C/min (linear, load-dependent) |
| Uniformity | ±0.5°C |
| Stability | ±0.3°C |
| Control Resolution | 0.01°C |
| Humidity Range (if equipped) | 20–98% RH |
| Compliance | GB/T 5170.2, GB/T 5170.5, GB/T 2423.1–2423.4, GB/T 2423.22, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (FOB) |
| Brand | Generic OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (FOB) |
| Standards Compliance | GB 10589-89, GB 10592-89, GB 10586-89, GB 11158-89, GB/T 5170.2–1996, GB/T 5170.5–1996 |
| Construction | SUS304 brushed stainless steel exterior or Baosteel cold-rolled steel with electrostatic powder coating |
| Insulation | Rigid polyurethane foam + ultra-fine glass wool |
| Air Circulation | Dual-axis adjustable centrifugal blower with horizontal/vertical louver system |
| Control System | PID-based programmable temperature controller with linear ramp profiling |
| Cooling | Capillary tube-based auto-load capacity regulation |
| Heating | Stainless steel sheathed resistive elements |
| Viewing Window | Reinforced double-glazed observation port with LED illumination |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,800–3,200 (FOB) |
| Temperature Range | –40 °C to +150 °C (standard) |
| Humidity Range | 30–98 % RH (standard) |
| Temp. Resolution | 0.01 °C |
| Humidity Resolution | 0.1 % RH |
| Temp. Uniformity | ±0.5 °C |
| Temp. Deviation | ≤ ±2 °C |
| Humidity Deviation | ≤ ±2.5 % RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen controller with programmable ramp-soak profiles |
| Power Supply | 380 V ±5 %, 50 Hz, 3P+N+G (custom 220 V available) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or A3 steel with epoxy powder coating |
| Compliance | GB10589, GB10592, GB11158, GB/T5170.2, GB/T5170.5, GB2423.1, GB2423.2, GB2423.22, GB2424.1 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Range | USD 13,500–14,800 (FOB) |
| Control System | Siemens S7-1200 PLC + 10.1″ Color TFT Touchscreen HMI |
| Temperature Setpoint Accuracy | ±0.1 °C |
| Temperature Indication Accuracy | ±0.1 °C |
| Sensor | PT100 Class A Platinum Resistance Thermometer (DIN EN 60751) |
| Heating | Independent Nickel-Chromium Alloy Heaters (PID-controlled) |
| Refrigeration | Dual-stage Cascade Refrigeration System with Tecumseh/Tecumseh-derived Hermetic Compressors |
| Air Circulation | Low-Noise, High-Torque AC Inverter-Driven Motor + Multi-Blade Centrifugal Impeller |
| Internal Dimensions | 600 × 500 × 500 mm (W×H×D) |
| External Dimensions | 1500 × 2100 × 2250 mm (W×H×D) |
| Chamber Construction | AISI 304 Stainless Steel (Interior & Exterior), Matte-Finish Surface |
| Insulation | 120 mm Thickness — Hybrid Layer of High-Density Mineral Wool + Rigid Polyurethane (PU) Foam (λ ≤ 0.022 W/m·K) |
| Door Sealing | Dual-Lip High-Tensile Silicone Packing (Rated for −200 °C to +400 °C) |
| Transition Mechanism | Pneumatic Actuated Dual-Zone Partition with Active Thermal Isolation Valves |
| Sample Zone Configuration | Static Single-Chamber Mode or Dynamic Two-Zone Switching Mode |
| Recovery Time (from −20 °C to +85 °C) | ≤ 3.5 min (per IEC 60068-3-5) |
| Linear Ramp Rate | Up to 15 °C/min (programmable, load-dependent) |
| Brand | HOYTOM |
|---|---|
| Origin | Spain |
| Model | Link RB |
| Test Height | 170 mm |
| Compliance | EN ISO 6508, ASTM E18, EN ISO 6506, ASTM E10 |
| Optional Accessories | HOYTOM LHB Digital Brinell Impression Measurement System, USB Digital Microscope (20×/30×/40×), Integrated Data Logging Software |
| Brand | LINKOPTIK |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | Nanolink SZ901 |
| Zeta Potential Range | No practical limit |
| Max Conductivity | 270 mS/cm |
| Temperature Operating Range | −15 °C to 120 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | ±0.1 °C |
| Particle Size Range | 0.3 nm – 15 μm |
| Measurement Angles | 12°, 90°, 173° |
| Accuracy (Size) | Better than ±1% (NIST-traceable standards) |
| Repeatability (Size) | Better than ±1% (NIST-traceable standards) |
| Minimum Sample Volume | 3 µL |
| Minimum Concentration | 0.1 mg/mL |
| Laser | 638 nm, 50 mW solid-state diode with integrated TEC stabilization and fiber coupling |
| Detector | High-sensitivity APD with dark count <20 cps |
| Correlator | High-speed digital correlator, dynamic range >10¹¹ |
| Molecular Weight Range | 340 Da – 2 × 10⁷ Da |
| Zeta Applicable Size Range | 1 nm – 120 μm |
| Electrophoretic Mobility Range | 0 to no practical limit |
| Temperature Control Precision | ±0.1 °C |
| Dimensions | 430 mm × 512 mm × 230 mm (L×W×H) |
| Weight | 20 kg |
| Brand | LINSEIS |
|---|---|
| Origin | Germany |
| Model | L40 EGA GC-MS |
| Temperature Range | Up to 1200 °C |
| Interface Type | Heated Capillary Transfer Line (100–350 °C) |
| GC Oven | Programmable, -10 to 350 °C |
| MS Detector | Quadrupole Mass Spectrometer (m/z 1–1000) |
| Detection Limit | <10 pg for selected ions |
| Compliance | ASTM E2892, ISO 11358-2, USP <1031>, GLP-ready data audit trail |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 12,500 (FOB) |
| Temperature Range | -70°C to +150°C |
| Humidity Range | 20–98% RH |
| Temp. Uniformity | ≤ ±2°C |
| Temp. Stability | ≤ ±0.5°C |
| Humidity Deviation | +2 / -3% RH |
| Control System | TEMI880 Touchscreen Controller (Korea) |
| Heating | Ni-Cr Alloy Heaters |
| Cooling | French Tecumseh Hermetic Compressor |
| Fluid Medium | Silicone Oil / Glycol / Water / Special Coolant |
| Sample Transfer Time | ≤10 s |
| Chamber Interior | SUS304 Stainless Steel |
| Insulation | Polyurethane Rigid Foam + Ultra-Fine Glass Fiber |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | LS-V |
| Pricing | Upon Request |
| Brand | LISICO |
|---|---|
| Model Series | SRV / SRD / DVP / DVM |
| Measurement Principle | Torsional Resonance (Viscosity & Density) |
| Viscosity Range | 0–3,000 mPa·s (cP), up to 50,000 mPa·s (cP) optional |
| Density Range | 0–1.5 g/mL, extended range available |
| Viscosity Accuracy | ±1% of reading or better (customizable) |
| Density Accuracy | ±0.01 g/mL standard, ±0.001 g/mL optional |
| Viscosity Resolution | 0.001 mPa·s (cP) |
| Density Resolution | 0.001 g/mL |
| Temperature Sensor | Pt1000 (Class B or AA), integrated |
| Operating Temp | −50 to +300 °C (model-dependent) |
| Pressure Rating | up to 207 MPa (30,000 psi) |
| Wetted Materials | 316L SS or Titanium Grade 5 |
| Enclosure Rating | IP68/IP69, Ex ia IIC T2–T6 |
| Response Time | <1 s |
| Sample Volume | 0.7 mL |
| Electrical Interface | M12 connector or fixed cable |
| Process Connection | 3/4″ NPT, sanitary clamp, 1″ NPT, or 1/4″ HP (9/16-18 UNF) |
| Brand | Lloyd Instruments |
|---|---|
| Origin | USA |
| Model | LD30 |
| Maximum Load Capacity | 30 kN (6,744 lbf) |
| Column Spacing | 452 mm (17.8 in) |
| Standard Crosshead Travel | 1070 mm (42 in) |
| Extended Crosshead Travel | 1669 mm (65.7 in) |
| Drive System | AC Servo Motor with Preloaded Ball Screw |
| Load Cell Type | Interchangeable Spoke-Type Load Cells |
| Compliance | CE Certified |
| Software | NEXYGENPlus with Built-in Standards Library |
| Frame Stiffness | High-Rigidity Dual-Column Architecture |
| Ease of Use | Intuitive Setup, Low Maintenance Design |
| Brand | Lloyd |
|---|---|
| Origin | USA |
| Model | LD10 |
| Maximum Load Capacity | 10 kN (2248 lbf) |
| Column Spacing | 452 mm (17.8 in) |
| Crosshead Travel (Standard) | 1070 mm (42 in) |
| Crosshead Travel (Extended) | 1669 mm (65.7 in) |
| Drive System | AC Servo Motor with Preloaded Ball Screw |
| Load Cell | Interchangeable Spoke-Type Sensor |
| Compliance | CE Certified |
| Software | NEXYGENPlus with Built-in Standards Library |
| Frame Stiffness | High-Rigidity Dual-Column Architecture |
| Ease of Use | Intuitive Setup, Low Maintenance |
| Brand | LLOYD |
|---|---|
| Origin | Denmark |
| Model | LSPlus Series |
| Instrument Type | Electromechanical Tensile and Compression Testing Machine |
| Maximum Test Force | 5000 kN |
| Speed Range | 0.001–2032 mm/min |
| Force Accuracy | ±0.5% of reading |
| Crosshead Travel | 800 mm |
| Displacement Resolution | 0.00004 mm |
| Brand | Logan |
|---|---|
| Origin | Tianjin, China |
| Model | KZ-4 |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Compliance Standards | NAS 1638, ISO 4406:1999, GJB 420B–2006, GJB 420A–1996, ROCT 17216 |
| Calibration Standards | ISO 4402, GB/T 18854–2002 (equivalent to ISO 11171:1999) |
| Detection Channels | 8 fixed-size channels |
| Display | OLED screen with membrane keypad interface |
| Housing Material | High-strength aluminum alloy |
| Environmental Rating | Industrial-grade, high-temperature & high-pressure resistant |
| Communication Interfaces | RS485 (standard), optional RS232 / Modbus RTU / 4–20 mA |
| Data Output Modes | Real-time particle count per channel + contamination grade |
| Optional Sensors | Water activity (a<sub>w</sub>) sensor, oil temperature sensor |
| Flow Monitoring | Integrated real-time flow rate measurement |
| Language Support | English / Chinese UI toggle |
| Explosion-Proof Variant | KZ-4F (Exib II BT3 Gb) |
| Software Features | Built-in calibration wizard, user-defined standard loading, audit-ready data logging |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-FHB08 |
| Price | USD 495 (FOB Qingdao) |
| Compliance | MEP “Guidelines for Standardization of Comprehensive Ecological and Environmental Protection Law Enforcement Equipment (Standard Configuration, 2020 Edition)” |
| Construction | Anodized aluminum frame chassis |
| Configuration Flexibility | Modular slot-based layout for field-customizable PPE integration |
| Transport Form Factor | Dual-option — rugged wheeled trolley case or ergonomic dual-shoulder backpack |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Floc-tester ET 730 / ET 740 / ET 750 |
| Stirring Positions | 4 (ET 730, ET 740) or 6 (ET 750) |
| Stirring Speed Range | 10–300 rpm |
| Timer Range | 0–999 min or 0–99 h (continuous) |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Sample Vessel Compatibility | 1000–1500 mL beakers (ET 740/ET 750) |
| Illuminated Rear Panel | Yes |
| Application Environment | Laboratory (ET 740/ET 750) and Field-Deployable (ET 730) |
| Brand | 3i |
|---|---|
| Origin | Germany |
| Model | LOW TEMPERATURE XYZ PIEZO SCANNER |
| Scanning Range | 50 × 50 × 24 µm @ 300 K, 30 × 30 × 15 µm @ <4 K |
| Operating Temperature Range | 10 mK – 300 K |
| Maximum Magnetic Field Tolerance | 40 T |
| Actuator Material | Piezoceramic stack integrated with titanium and alumina ceramic housing |
| Structural Components | Stainless steel screws, oxygen-free copper wiring, FR4 PCB substrate |
| Feedback Option | Closed-loop operation available per axis with heterodyne fiber interferometry (1–10 µW optical power per axis) |
| Mass | 16 g |
| Dimensions | 24 × 24 × 9.2 mm |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Frequency Range | 100–300 rpm |
| Amplitude (p-p) | 25.4 mm |
| Timer Range | 0–99 h 99 min |
| Frequency Display Resolution | 0.1 rpm |
| Vibration Mode | Rotary (eccentric cam-driven) |
| Max Load Capacity | 100 kg |
| Effective Table Size | 1000 × 1000 mm |
| Motor Power | 1 HP (0.75 kW) |
| Dimensions (W×D×H) | 1100 × 1300 × 650 mm |
| Weight | ~300 kg |
| Max Acceleration Limit | 20 g (calculated per ISO 10816-1 & ASTM D999) |
| Max Amplitude Constraint | 5 mm (frequency-dependent, per EN 1010-1 derived envelope) |
| Compliance | ISTA 2A/3A, ASTM D999, ANSI X3.31, UL 60950-1, EN 61000-6-2 |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | DWS RheoLab |
| Temperature Range | 5°C–100°C |
| Frequency Range | 0.1 Hz–10 MHz |
| Minimum Measurable Frequency | 0.1 Hz |
| Maximum Measurable Frequency | 10⁷ Hz |
| Sample Volume Requirement | ≥150 µL |
| Sample State | Liquid |
| Measurement Principle | Diffusing Wave Spectroscopy (DWS) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | LS Instruments RheoSoft v5.x |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | LS Spectrometer |
| Particle Size Range | 0.15 nm – 5 µm |
| Temperature Control | Up to 90 °C |
| Measurement Principles | Dynamic Light Scattering (DLS) and Static Light Scattering (SLS), upgradable to 3D and Modulated 3D techniques |
| Sample Volume | 50 µL – 4 mL |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | LSI Correlator |
| Application Scope | Dynamic Light Scattering (DLS), Fluorescence Correlation Spectroscopy (FCS), Diffusing Wave Spectroscopy (DWS), Diffuse Correlation Spectroscopy (DCS) |
| Correlation Algorithm | Multi-tau and Linear-tau Digital Correlation |
| Time Delay Range | 12.5 ns – 3436 s (13 decades) |
| Number of Channels | 322 total (296 detection + 26 auxiliary) |
| Fastest Configurable Initial Delay | 12.5 ns, 200 ns, 400 ns, 800 ns, or 3200 ns |
| Normalization Modes | Symmetric and Compensation Normalization |
| Max. Count Rate | 20 Mcps (at 52 ms integration) |
| Interface | USB 2.0 and Gigabit Ethernet |
| OS Support | Windows & Linux |
| Firmware Upgradability | Field-upgradable via host software |
| Power Supply | External stabilized DC source |
| Dimensions | 120 × 120 × 53.6 mm (aluminum housing) |
| Detector Protection | Real-time gated output with user-defined count-rate threshold |
| Synchronization | Dedicated clock output for hardware timing alignment |
| Software Integration | Native APIs for MATLAB, LabVIEW, Python |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | NanoLab 3D |
| Particle Size Range | 0.3 nm – 10 µm |
| Sample Volume | as low as 4 µL (optional) |
| Temperature Control Range | 4 °C – 85 °C |
| Viscosity Measurement Range | 0.01 cP – >1000 cP |
| Compliance | ISO 22412 (at ≤23 °C ambient) |
| Technique | Modulated 3D Cross-Correlation DLS |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,600 (FOB) |
| Internal Chamber Dimensions | 80 × 80 × 80 cm or 100 × 100 × 100 cm |
| Spray Ring Radius | 400 mm |
| Spray Pipe Diameter | φ16 mm |
| Nozzle Orifice Diameter | 0.4 mm |
| Nozzle Spacing | 50 mm |
| Oscillating Arm Range | ±60°, ±90°, ±160° |
| Turntable Speed | 1 rpm (standard), variable-speed option available |
| Rain Duration | Adjustable up to 15 min |
| Intermittent Interval | Adjustable up to 30 min |
| Rainfall Intensity | Up to 150 mm/h (adjustable) |
| Viewing Window | Large-area tempered glass door |
| Construction Material | Mirror-finish SUS304 stainless steel (inner & outer chamber, turntable) |
| Safety Protections | Leakage protection, short-circuit protection, motor overload protection |
| Power Supply | 1Φ3W AC220V±10% 50/60 Hz or 3Φ5W AC380V±10% 50/60 Hz |
| Compliant Standards | GB/T 10485–2007, GB/T 4208–2008, GB/T 4942.2–1993 |
| Brand | OEM / Third-party Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Chamber Dimensions (W×D×H) | 1000 × 1000 × 1000 mm |
| Operating Temperature Range | +5 to +36 °C |
| Max Relative Humidity | ≤85 %RH |
| Nozzle Quantity | 25 |
| Nozzle Diameter | 0.4 mm |
| Nozzle Spacing | 50 mm |
| Spray Arm Radius | 375 mm |
| Spray Arm Inner Diameter | 16 mm |
| Oscillation Angle | Adjustable from ±45° to ±90° (180° total sweep) |
| Oscillation Speed | 60°/s (variable via frequency inverter) |
| Construction | Cold-rolled steel exterior with powder coating |
| Sealing | Dual-layer silicone rubber gasket with rotary waterproof joint |
| Viewing Window | Reinforced organic glass with integrated wiper and LED lighting |
| Brand | 3i |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LT-sSNOM |
| Price | Upon Request |
| Wavelength Range | 532 nm – 20 µm (with metallic reflective optics) |
| AFM Scanner | Fiber-interferometer-equipped piezoelectric stage, scan range 30 × 30 × 15 µm (@ 4 K) |
| XYZ Sample Nanopositioner | 6 × 6 × 12 mm travel |
| Off-Axis Parabolic Mirror Nanopositioner | 4 × 4 × 6 mm travel |
| Position Sensor Resolution | 200 nm (resistive) |
| Outer Diameter | 49 mm |
| Temperature Range | 10 mK – 300 K |
| Maximum Magnetic Field | 31 T |
| Electrical Contacts | 8-point feedthrough on sample stage |
| Supported AFM Modes | Contact, Dynamic, Non-Contact (ncAFM), Magnetic Force Microscopy (MFM), Conductive AFM (cAFM), Kelvin Probe Force Microscopy (KPFM), Photoinduced Force Microscopy (PRFM), Electrostatic Force Microscopy (EFM) |
