Physical Property Testing Instruments
Filter
Showing 2221–2250 of 12279 results
| Platform Dimensions | 500 × 500 mm |
|---|---|
| Shaker Body Dimensions | 500 × 450 × 500 mm |
| Mounting Pattern | 25 × M10 threaded holes on platform surface |
| Vibration Axes | Independent or simultaneous excitation along X (horizontal, left–right), Y (vertical, up–down), and Z (horizontal, front–back) |
| Frequency Range | 1–5000 Hz (display resolution: 0.01 Hz) |
| Peak-to-Peak Displacement | 0–4 mm adjustable |
| Maximum Load Capacity | 75 kg |
| Peak Sinusoidal Force | 1125 kgf (≈11.03 kN) |
| Maximum Acceleration | ≤15 g (peak) |
| Waveform Options | Sinusoidal (full- or half-wave), programmable random, road-profile-simulated vibration, multi-axis coupled motion (4-DOF synchronized), mixed-mode (e.g., half-wave on Y + full-wave on X) |
| Test Duration Setting | 0–999,999 s (user-defined) |
| Power Consumption | 3.8 kW |
| Input Current | ≤15 A |
| Supply Voltage | 380 V ±20%, 3-phase, 50/60 Hz |
| Acceleration–Amplitude–Frequency Relationship | aₚₑₐₖ (g) = 0.002 × f² (Hz²) × D (mm, p–p) |
| Brand | OK |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Import Status | Domestic Production with Imported Component Integration |
| Price | USD 14,000–18,000 (FOB China) |
| Internal Chamber Dimensions (W×H×D) | 50×75×60 cm to 100×100×100 cm |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 20–98 %RH (optional: 5–98 %RH) |
| Rapid Temperature Transition Ranges | −45 °C to +85 °C or −20 °C to +85 °C |
| Ramp Rates | 5–25 °C/min (user-selectable) |
| Temperature Uniformity | ±2 °C |
| Temperature Stability | ±0.5 °C |
| Humidity Uniformity | ±3.0 %RH (at ≥75 %RH) |
| Humidity Stability | ±2.5 %RH |
| Construction Material | SUS304 Stainless Steel |
| Refrigeration System | Hermetic Dual-Stage Compressor with Eco-Friendly Refrigerants (R404A/R23) |
| Controller | Touchscreen LCD with English/Chinese Interface |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Brand | OEM / Custom-Branded |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 3,000–4,200 (FOB) |
| Temperature Range | –70°C to +180°C (standard models) |
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±0.5°C (at 25°C, empty chamber) |
| Humidity Uniformity | ±2.5% RH (at 60°C/90% RH) |
| Ramp Rate | 1–3°C/min (average air temperature, unloaded) |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2021, MIL-STD-2164A |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 2,600 (Reference Only) |
| Internal Dimensions (W×H×D, cm) | 40×50×40 to 100×100×100 |
| Temperature Range | −70 °C to +150 °C (configurable models) |
| Humidity Range | 5–98 %RH (standard: 20–98 %RH) |
| Temperature Uniformity | ±0.5 °C |
| Humidity Uniformity | ±2.5 %RH |
| Temperature Fluctuation | ±2 °C |
| Humidity Fluctuation | +2–3 %RH |
| Resolution | 0.1 °C / 0.1 %RH |
| Heating Rate | ~4.0 °C/min |
| Cooling Rate | ~1.0 °C/min |
| Refrigeration System | Hermetic dual-stage compressor with eco-friendly refrigerants (R404A/R23) |
| Controller | Touchscreen LCD with bilingual (EN/CN) interface |
| Construction Material | SUS#304 stainless steel |
| Compliance Standards | MIL-STD-810G (Method 501.6, 502.6), IEC 60068-2-1 (Cold), IEC 60068-2-2 (Dry Heat), IEC 60068-2-78 (Steady-State Damp Heat), IEC 60068-2-30 (Cyclic Damp Heat), GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.4–2012 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -20°C to 150°C / -40°C to 150°C / -60°C to 150°C / -70°C to 150°C |
| Humidity Range | 30–98% RH (at 25–80°C) |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Humidity Fluctuation | +2% / −3% RH |
| Heating Rate | 1.0–3.0°C/min |
| Cooling Rate | 0.7–1.2°C/min |
| Timer Range | 0–9999 h |
| Power Supply | AC 380 V, 50 Hz |
| Control System | PID + SSR with PT100 Platinum Resistance Sensors, 0.1°C Resolution, Real-Time Curve Display |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Temperature Range | -40 °C to +100 °C |
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±1 °C |
| Humidity Uniformity | ±5% RH |
| Sensor Placement | Directly in Test Zone (Not in Air Duct) |
| Cooling System | Air-Cooled, Single-Stage Compressor (for –20 °C base), Dual-Stage Compressor (for –40 °C to –70 °C) |
| Insulation Material | High-Density Polyisocyanurate Foam with High-Temperature Resistance |
| Safety Protections | Fuseless Circuit Breaker, Compressor Overload Protection, Refrigerant High/Low Pressure Switches, Over-Temperature Cut-Off, Integrated Fault Alert System |
| Brand | OK |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -40°C to +150°C (configurable models) |
| Humidity Range | 20–98% RH |
| Temperature Ramp Rate | Up to 4.0°C/min (heating), 1.0°C/min (cooling) |
| Temperature Uniformity | ±2.0°C |
| Temperature Fluctuation | ±0.5°C |
| Humidity Fluctuation | ±2.5% RH |
| Internal Dimensions | 500×400×400 mm to 700×600×600 mm (model-dependent) |
| Insulation | Dual-layer — rigid polyurethane foam + fiberglass |
| Refrigerant | R404A/R23 (zero ODP, non-ozone-depleting) |
| Controller | 7-inch TFT color LCD touch interface with bilingual (EN/CN) firmware |
| Compliance | GB/T 2423.1–2423.4, GB/T 2423.22, IEC 60068-2-1/2, GJB 150.3/4/9 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing Reference | USD 2,650 (excl. tax & freight) |
| Temperature Range | -70°C to +180°C (standard) |
| Humidity Range | 20%–98% RH |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Control Method | Balanced Temperature & Humidity Control (BTHC) via PID + SSR |
| Compressor | Hermetic Twin-Screw Type (R404A refrigerant) |
| Noise Level | <60 dB(A) |
| Compliance | GB/T 2423.1, GB/T 2423.2, IEC 60068-2-1, MIL-STD-2164A, GJB 1032 |
| Brand | OK |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | A: 0–150 °C |
| B | −20–150 °C |
| C | −40–150 °C |
| D | −70–150 °C |
| Humidity Range | 20–98 %RH (optional: 5–98 %RH or 10–98 %RH) |
| Temperature Uniformity | ±0.5 °C |
| Humidity Uniformity | ±2.5 %RH |
| Temperature Fluctuation | ±2 °C |
| Humidity Fluctuation | +2–3 %RH |
| Resolution | 0.1 °C / 0.1 %RH |
| Heating Rate | ~4.0 °C/min |
| Cooling Rate | ~1.0 °C/min |
| Internal Dimensions (W×H×D, cm) | 40×50×40 to 100×100×100 |
| External Dimensions (W×H×D, cm) | 100×165×100 to 180×200×180 |
| Refrigeration System | Hermetically sealed, low-noise, dual-stage compressor with eco-friendly refrigerants R404A/R23 |
| Controller | LCD touch-screen interface with English/Chinese language toggle |
| Construction Material | SUS#304 stainless steel |
| Standard Accessories | One Φ50 mm cable port, two-tier SUS#304 adjustable shelves, four casters + four leveling feet |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-phase 5-wire, 2.5 m cable |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Model | LXJ-Capacity |
| Maximum Load | 35–200 kg |
| Number of Test Stations | 4–64 |
| Acceleration Range | 30–200,000 m/s² |
| Specimen Height Limit | 200–300 mm |
| Test Axes | X, Y, Z (independently configurable) |
| Mounting Radius (from rotation center) | 200–1000 mm |
| Startup Time | ≤3–5 min |
| Continuous Operation Duration | 30–60 min |
| Power Supply | AC 380 V, 1.5–6.5 kVA |
| Dimensions (L×W×H) | 924×910×1242 mm to 1953×470×993 mm |
| Slip Ring Configuration | 15-channel, 500 V / 5 A |
| Weight | 1000–2300 kg |
| Compliance Standards | GJB 150, GJB 360, GJB 548, GB/T 2423, MIL-STD-202F, MIL-STD-810F, MIL-STD-883C, IEC 60068-2-27 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Internal Dimensions (mm) | 500×600×500 / 600×700×600 / 800×900×700 / 1000×1000×1000 |
| External Dimensions (mm) | 1000×1750×1100 / 1100×1900×1100 / 1300×1900×1300 / 1500×2000×1600 |
| Temperature Range | −10 °C to 80 °C or −20 °C to 80 °C (customizable) |
| Temperature Uniformity | ±2.0 °C |
| Temperature Fluctuation | ±0.5 °C |
| Rainfall Intensity | 25 mm/h |
| Nozzle Orifice Diameter | φ0.4 mm |
| Simulated Droplet Diameter | 1.0–1.5 mm |
| Ice Accumulation Thickness Options | 6 mm, 13 mm, 37 mm, 75 mm |
| Ice Density Range | 0.2–0.9 g/cm³ |
| Water Temperature Control | 0–5 °C |
| Inner Chamber Material | SUS304 Stainless Steel |
| Outer Chamber Material | Galvanized Steel with Powder Coating or Optional SUS304 |
| Heating System | Helical Ni-Cr Alloy Heaters with Ceramic Insulation |
| Humidification | Embedded Ni-Cr Alloy Heater-Based Humidifier |
| Refrigeration Unit | Hermetic Compressor (French or Tecumseh) |
| Controller | 5.7″ TFT Color LCD Touchscreen (Bilingual English/Chinese) |
| Cable Port | Ø50 mm × 1 |
| Standard Accessories | Adjustable Test Sample Rack, Power Supply: AC 220 V ±5%, 50 Hz ±0.5 Hz, Single-Phase Three-Wire |
| Operating Ambient | 5–35 °C, RH ≤85% |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-HC-1000 |
| Sand Composition | 97–99% SiO₂ (silicon dioxide) |
| Sand Blowing Concentration | 1.1 g/m³ ±0.25 g/m³ to 2.2 g/m³ ±0.5 g/m³ |
| Sand Blowing Velocity | 0–29 m/s |
| Dust Blowing Concentration | 0.1–10.6 g/m³ ±7 g/m³ |
| Dust Blowing Velocity | 8.9 m/s ±1.2 m/s |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,650 (approx.) |
| Internal Dimensions (W×H×D, cm) | 40×50×40 to 100×100×100 |
| External Dimensions (W×H×D, cm) | 100×165×100 to 180×200×180 |
| Temperature Range | -70 °C to +150 °C (configurable models) |
| Humidity Range | 20–98 %RH (optional: 5–98 %RH) |
| Temperature Uniformity | ±0.5 °C |
| Humidity Uniformity | ±2.5 %RH |
| Temperature Fluctuation | ±2 °C |
| Humidity Fluctuation | +2–3 %RH |
| Resolution | 0.1 °C / 0.1 %RH |
| Ramp Rate (Heating) | ~4.0 °C/min |
| Ramp Rate (Cooling) | ~1.0 °C/min |
| Refrigeration System | Hermetic, low-noise, dual-stage compressor (R404A/R23) |
| Controller | 7-inch color touchscreen, bilingual (English/Chinese) |
| Construction Material | SUS#304 stainless steel (inner & outer chamber) |
| Viewing Window | Multi-layer tempered glass with conductive film |
| Port | Ø50 mm test port (left side) |
| Safety Features | Real-time fault detection, automatic power cutoff, over-temperature/humidity protection |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| External Dimensions (W×H×D) | 145×180×140 cm to 190×170×270 cm |
| Hot Zone Temperature Range | RT to +200 °C |
| Cold Zone Temperature Range | RT to −70 °C |
| Test Zone Temperature Range | +60 °C to +150 °C (hot shock) |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Recovery Time | <5 min |
| Preheating Time (RT→150 °C) | ~30 min |
| Precooling Time (RT→−70 °C) | ~85 min |
| Refrigeration System | Hermetic or Semi-Hermetic Compressor with Eco-Friendly Refrigerants (R404A/R23) |
| Construction | Interior – SUS#304 Mirror-Finish Stainless Steel |
| Insulation | High-Density Fire-Retardant PU Foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Power Supply | AC220V±10% 50Hz / AC380V±10% 50Hz |
| Operating Ambient Temperature | +5°C to +35°C |
| Temperature Range (A/B/C) | −20°C to +100°C / −40°C to +100°C / −60°C to +100°C |
| Temperature Uniformity | ≤ ±2.0°C |
| Temperature Stability | ≤ ±0.5°C |
| Temperature Deviation | ≤ ±2.0°C |
| Heating Rate | ≥3°C/min |
| Cooling Rate | 0.7–1.0°C/min |
| Refrigeration System | Air-Cooled Single-Stage Mechanical Compression |
| Compressor | Hermetic Industrial Scroll Compressor |
| Controller | Intelligent PID-Based Digital Temperature Controller |
| Internal Chamber Material | SUS304 Stainless Steel |
| Compliance | GB10589, GB11158, GB10586, IEC 60068-3-5, GB/T 2423-1/2/3/4 |
| Brand | LienSheng |
|---|---|
| Origin | Taiwan |
| Model | LS-905 |
| Instrument Type | Static Coefficient of Friction Tester |
| Max Inclination Angle | 45° |
| Tilt Rate | 1.5 ± 0.5 °/s |
| Test Block Dimensions | 100 mm (L) × 50 mm (W) × 750 g |
| Sample Platform Size | 125 mm (W) × 280 mm (L) |
| Motor | 110 V, 5 W |
| Overall Dimensions | 400 mm (L) × 350 mm (W) × 350 mm (H) |
| Weight | 2.5 kg |
| Compliant Standards | CNS 13119, TAPPI T815 om-85 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKF |
| Temperature Range | -40 °C to +180 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Internal Volume | 60 L to 734 L (depending on model) |
| Integrated Water Tank Capacity | 20 L |
| Refrigerant | R-452A |
| Compliance | DIN 12880 Class 2 Temperature Safety Device, IEC 60068, MIL-STD-810, ASTM D4332 |
| Control System | MCS Touchscreen Controller with Time/Real-Time Programming, Built-in Data Logger, USB & Ethernet Interfaces |
| Condensation Protection | Programmable |
| Humidity Generation | Steam-based, Capacitive RH Sensor |
| Brand | KRÜSS |
|---|---|
| Origin | Germany |
| Model | BPT Mobile |
| Surface Tension Range | 10–100 mN/m |
| Resolution | 0.1 mN/m |
| Surface Age Range | 10–30,000 ms |
| Temperature Measurement Range | 0–100 °C |
| Display | 5-inch IPS touchscreen (480 × 854 px) |
| Battery Life | Up to 10 hours |
| Dimensions (W × D × H) | 85 × 55 × 220 mm |
| Weight (without accessories) | 600 g |
| Measurement Principle | Bubble Pressure Method |
| Brand | Jinan Winner |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Winner2000ZDE |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–300 µm |
| Repeatability | <0.5% (D50 of NIST-traceable standard reference material) |
| Measurement Time | <2 min per run |
| Laser Source | He-Ne, λ = 632.8 nm, output power >2 mW, lifetime >25,000 h |
| Detector Channels | 39 |
| Standards Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Ultrasonic Dispersion | 40 kHz, 35 W, adjustable duration ≥1 s |
| Stirring Speed | 0–3000 rpm (continuously adjustable) |
| Circulation Flow Rate | 8 L/min |
| Sample Cell Volume | 350 mL |
| Dimensions | 860 × 360 × 440 mm |
| Weight | 40 kg |
| Brand | Chengdu Jingxin (CDJX) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Bulk Density & Flow Tester |
| Instrument Type | Portable |
| Measurement Type | Solid Powder |
| Application | Metal powder flowability and apparent density testing |
| Standards Compliance | GB/T 1482–2010 (Hall Flow), GB/T 1479.1–2011 (Apparent Density) |
| Funnel Orifice Diameters | 2.5 mm and 5.0 mm |
| Funnel Cone Angle | 60° |
| Funnel-to-Cylinder Distance | 25 mm ± 2 mm (adjustable) |
| Cylinder Volume | 25 mL (stainless steel 304) |
| Scraper Blade | Stainless steel, 25 mm wide |
| Stopper Rod | Stainless steel 304 |
| Dimensions | Approx. 230 × 170 × 300 mm |
| Weight | 3.7 kg |
| Timer Resolution | 0.01 s |
| Brand | Tuofeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electromechanical Universal Testing Machine |
| Model | TFW-163 |
| Max Test Load | 5–100 kN (configurable) |
| Accuracy Class | 0.5 |
| Force Measurement Range | 0.4–100% FS |
| Force Indication Error | ±0.5% of reading |
| Force Resolution | 1/500,000 of full scale, unsegmented |
| Deformation Measurement Range | 0.2–100% FS |
| Deformation Error | ±0.5% of reading |
| Deformation Resolution | up to 1/300,000 |
| Displacement Error | ±0.5% of reading |
| Column Spacing | 840 mm |
| Crosshead Travel | 1000 mm (subject to chamber clearance) |
| Dimensions (W×D×H) | 1250 × 560 × 2400 mm |
| Weight | ~380 kg |
| Power Supply | AC 220 V / 50 Hz ±10%, 750 W |
| Environmental Chamber Temp Range | −40 °C to +100 °C |
| Chamber Internal Dimensions | 360 × 300 × 500 mm (W×D×H) |
| Chamber Heating Power | 1.5 kW |
| Chamber Temperature Stability | ±2 °C over 100 mm vertical zone |
| Chamber Ramp Rate | ≤30 min to +100 °C from ambient |
| Temperature Equilibration Time | ≤5 min (both above and below 0 °C) |
| Chamber Control | Programmable PID with Pt100 sensors, LCD controller, dual-port access (50 mm Ø), sliding thermal barrier inserts, stainless steel 304/316 construction, silicone door seal, centrifugal blower, compressor + resistive heating system |
| Brand | Stable Micro Systems |
|---|---|
| Origin | United Kingdom |
| Model | TA.XT Plus C |
| Force Range | ±5 kg / ±30 kg / ±50 kg |
| Speed Range | 0.01–40 mm/s |
| Distance Resolution | 0.001 mm |
| Force Accuracy | 0.0002% of full scale |
| Test Distance Range | 0.001–295 mm |
| Operating Temperature | 0–40 °C |
| Dimensions (H×W×D) | 665 × 280 × 440 mm |
| Weight | 16.2 kg |
| Power Supply | 220 V, 50 Hz |
| Interface | RS232 or USB |
| Software | Multilingual (including English and Chinese), ASTM/ISO/AOAC-compliant method library |
| Probe Options | 300+ application-specific probes |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JH-Series Customizable Battery Drop Impact Tester |
| Price Range | USD 850 – 8,500 |
| Brand | Jianhu |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JH-500 |
| Price | Upon Request |
| Internal Dimensions (W×D×H) | 700 × 800 × 900 mm |
| External Dimensions (W×D×H) | 1450 × 1100 × 2000 mm |
| Power Rating | 6.0 kW |
| Temperature Range | RT +10 °C to 200 °C / 300 °C (optional) |
| Temperature Uniformity | ±2 °C |
| Temperature Stability | ±0.5 °C |
| Air Exchange Rate | 2–100 cycles/hour |
| Adjustable Air Exchange Interval | 1 min – 99 h |
| Test Port | Ø50 mm (left side) |
| Turntable Diameter | Ø500 mm |
| Insulation | High-density ultra-fine glass fiber |
| Controller | Imported LED digital PID + SSR microcomputer controller |
| Set/Display Resolution | 0.1 °C |
| Timer Range | 1–9999 min |
| Compliance | JB/T 7444–1994, GB/T 3512–2001 |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | WSM-20KN |
| Maximum Test Load | 20 kN |
| Load Cell Accuracy | ±0.5% FS |
| Force Measurement Accuracy | ±0.5% |
| Speed Accuracy | ±0.5% |
| Speed Range | 0.05–500 mm/min |
| Displacement/Strain Accuracy | ±0.5% |
| Extensometer Range | 10–1000 mm |
| Crosshead Travel (Effective) | 1160 mm |
| Test Width | 420 mm |
| Distance Between Grips (Effective) | 860 mm |
| Temperature Chamber Range | −40 °C to +150 °C |
| Brand | Changchun Intelligent |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJL-200B |
| Torque Range | 0–200 N·m (Rated: 300 N·m) |
| Torque Measurement Accuracy | ±0.3% F.S. |
| Speed Range | 0.1–200 rpm |
| Speed Control Accuracy | ±0.1% F.S. |
| Motor Power | 5.0 kW (Panasonic Servo Motor & Drive) |
| Reduction Ratio | 10:1 |
| Melt Pressure Range | 0.1–100 MPa |
| Pressure Measurement Accuracy | ±0.3% F.S. |
| Temperature Control Range | Ambient to 350 °C |
| Temp. Control Channels | 5 (extruder), 7–8 (twin-screw), 3 (mixer) |
| Temp. Control Accuracy | ±0.5 °C |
| Screw Diameter | 22 mm |
| L/D Ratio | 40:1 |
| Screw Configuration | Modular Co-Rotating Parallel Twin-Screw |
| Max. Screw Speed | 500 rpm |
| Mixer Capacity | 60 mL / 200 mL |
| Max. Mixer Torque | 200 N·m |
| Heating Method | Segmented Electric Heating (5500 W extruder |
| Cooling Method | Compressed Air |
| Data Acquisition Rate | 50 Hz |
| Software Version | 4.1.14–4.1.18 (Torque Rheology, Melt Viscosity, Extrusion, Mixing Modules) |
| Changchun Intelligent JJ-20 Cryogenic Impact Testing Machine (Dual-Mode | Charpy & Izod) |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JJ-20 |
| Pricing | Available Upon Request |
| Max Impact Energy | 4 J (Charpy), 5.5 J (Izod) |
| Sampling Rate | 1.2 µs |
| A/D Resolution | 1/65536 |
| Load Range Selection | ×1, ×2, ×4, ×8 |
| Load Measurement Accuracy | ≤1% FS |
| Charpy Span Options | 40 mm, 60 mm, 62 mm |
| Charpy Specimen Dimensions | 4×6×50 mm, 4×10×80 mm |
| Izod Specimen Dimensions | 4×10×80 mm |
| Charpy Pendulum Velocity | 2.9 m/s |
| Izod Pendulum Velocity | 3.50 m/s |
| Temperature Range | –40 °C to ambient |
| Temperature Stability | ±0.5 °C |
| Temperature Uniformity | ±2 °C |
| Sample Handling | Semi-automatic feed, manual positioning |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | JJ-20W |
| Quotation | Available Upon Request |
| Impact Energy Range | 0.5 J, 1 J, 2 J, 4 J, 7.5 J |
| Sampling Rate | 1.2 µs |
| A/D Resolution | 1/65536 |
| Load Measurement Accuracy | ≤2% |
| Span Options | 60 mm, 62 mm |
| Specimen Thickness | 4 mm, 10 mm, 13 mm |
| Specimen Width | 6 mm, 10 mm, 13 mm, 15 mm |
| Pendulum Impact Velocity (0.5–4 J) | 2.9 m/s |
| Low-Temperature Range | –60 °C (cascade refrigeration), –120 °C (liquid nitrogen injection) |
| High-Temperature Range | up to +200 °C (electric heating) |
| Temperature Control Accuracy | ±1 °C |
| Compliance | GB/T 1043.1–1993 (Charpy & Izod impact testing of rigid plastics) |
| Brand | Jiubin |
|---|---|
| Model | JB-DTA-1350 |
| Origin | Shanghai, China |
| Temperature Range | Ambient to 1350 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 1–80 °C/min |
| DTA Signal Range | ±2000 μV |
| DTA Sensitivity | 0.01 μV |
| Temperature Resolution | 0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Furnace Type | Top-opening dual-wound Fe-Cr-Al heating element (1 kW) |
| Atmosphere Control | Automated internal gas switching |
| Interface | Standard USB 2.0 |
| Display | 7-inch 24-bit color TFT LCD touchscreen |
| Calibration | Built-in reference materials with one-click temperature calibration |
| Baseline Adjustment | Adjustable slope and intercept |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-JM8 |
| Pricing | Available Upon Request |
| Pressure Range | 0–2 MPa |
| Pulse Frequency | 0–3 Hz |
| Cycle Count | Up to 10⁷ cycles (programmable) |
| Environmental Temperature Range | −50 °C to +200 °C (constant or cyclic control) |
| Fluid Temperature Range | −50 °C to +200 °C (constant or cyclic control) |
| Test Media | Deionized water, ethylene glycol solutions, antifreeze mixtures, emulsions |
| Vibration Modes | Electromagnetic single-axis, mechanical single-axis, servo-controlled triaxial, robotic 6-DOF, rotational mechanical |
| Pulse Waveforms | Sine, triangular, trapezoidal, quasi-square |
| Channel Capacity | 2–10 independent test circuits |