| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-B |
| Price Range | USD 11,200 – 21,000 |
| Sensor Dimensions | 460 mm × 620 mm |
| Active Sensing Area | 400 mm × 400 mm |
| Sensor Resolution | 2,288 discrete pressure points |
| Thickness | 0.2 mm |
| Maximum Load Capacity | 100 kg (≈981 N) |
| Accuracy | ±10% FS (as-received), ±5% FS (post-calibration) |
| Operating Temperature | −9 °C to +60 °C |
| Interface | USB 2.0 |
| Power Supply | Bus-powered via USB |
| Sampling Rate | 0–100 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | QUV1003 (Spray-Enabled) |
| Instrument Type | Electronic Universal Testing Machine for Accelerated Aging |
| Temperature Range | RT+10°C to 70°C |
| Temperature Uniformity | ±3°C |
| Humidity During Condensation | ≥75% RH |
| Standard Irradiation Temperature Options | 50°C, 60°C (recommended), or 70°C (±3°C tolerance) |
| Condensation Temperature | 50°C (±3°C) |
| Cycle Options | 4h UV / 4h Condensation or 8h UV / 4h Condensation |
| UV Lamp Center-to-Center Spacing | 65–70 mm |
| Specimen-to-Lamp Distance | 55 mm |
| UV Spectrum | UV-B (280–315 nm) |
| Standard Specimen Size | 75 × 150 mm |
| Water Requirement | Deionized or Distilled Water, ~8 L/day |
| Internal Chamber Dimensions (D×W×H) | 450 × 1165 × 500 mm |
| Overall Dimensions (D×W×H) | 600 × 1325 × 1480 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DM-III |
| Pricing | Available Upon Request |
| Stroke Frequency | 0–135 cycles/min (single-pass) |
| Counter Range | 0–9999 (dual-pass |
| Abrading Head Mass | 570 ± 20 g |
| Optional Weights | 50 g, 100 g, 200 g |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 60 W |
| Dimensions (L×W×H) | 300 × 280 × 380 mm |
| Net Weight | ~25 kg |
| Brand | Hengyi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY(DK)TBRTY |
| Spindle Speed | 24,000 rpm |
| Feed Rate | 0–500 mm/min |
| Cutting Depth | 2–20 mm |
| Compatible Pipe Diameter | 50–250 mm |
| Max. Workpiece Length (Pipe/Sheet) | 260 mm |
| X-Axis Travel | 280 mm |
| Y-Axis Travel | 310 mm |
| Z-Axis Travel | 70 mm |
| Frame Material | Aluminum Alloy |
| Stepper Motor & Driver Sets | 3 |
| High-Speed Variable-Frequency Spindle Motor | 1 |
| Precision Linear Guide Rods | 6 |
| Precision Ball Screws | 3 |
| Standard Vise | 1 set |
| Tooling Options | Cylindrical end mill, 20° flat-bottom cutter, slitting blade, 45° chamfering cutter |
| Tool Diameters | Φ3 mm, Φ4 mm, Φ6 mm |
| Max. Machining Envelope | 300 × 150 × 100 mm |
| Power Supply | 220 V AC |
| Total Power Consumption | 1500 W |
| Net Weight | 45 kg |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 4350 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E659D |
| Pricing | Upon Request |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ADE Series |
| Standard Compliance | ASTM E681, EN 45014, GB/T 12474-2008 |
| Operating Pressure Range | 0 to 101 kPa (gauge), adjustable down to –100 kPa (gauge) |
| Maximum Test Temperature | 150 °C |
| Oven Max Temperature | 300 °C |
| Ignition Source | 15 kV, 30 mA pulsed arc, 0.5 s duration |
| Electrode Gap | 3–4 mm |
| Reaction Tube Dimensions | 1400 ± 50 mm length, 60 ± 5 mm ID, ≥2 mm wall thickness (borosilicate glass) |
| Vent Valve Diameter | ≥25 mm |
| Stirring | Magnetic stirrer at tube base |
| Safety Interlock | Dual-door mechanical/electrical interlock with remote activation |
| Flame Detection | Visual + optional thermocouple-assisted detection for non-luminous flames (e.g., H₂) |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | YL-JZ-2T |
| Maximum Applied Force | 20 kN (2 metric tons) |
| Max Sample Dimensions | W30 × D30 cm |
| Overall Dimensions | W88 × H168 × D73 cm |
| Crush Stroke Range | 0–300 mm (adjustable) |
| Crush Speed | 1–500 mm/min (customizable) |
| Nail Penetration Speed | 1–50 mm/s (customizable) |
| Force Accuracy | ±0.5% of reading |
| Force Resolution | 1/500,000 full scale |
| Displacement Accuracy | ±0.5% of reading |
| Displacement Resolution | 0.01 mm |
| Force Units | N, kN, kgf, lbf |
| Control Interface | RS232 / RS485 |
| Voltage Measurement Range | 0–36 V (±0.5% FS) |
| Temperature Measurement Range | 0–300 °C (±1 °C) |
| Data Acquisition Rate | ≥30 Hz per channel |
| Video Monitoring | Optional HD in-chamber camera system |
| Safety Features | Overload, overtemperature, overvoltage, leakage, and emergency acoustic-optic alarm |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TS-80 |
| Pricing | Upon Request |
| Internal Dimensions (W×H×D) | 40×50×40 cm |
| Volume | 80 L |
| Temperature Range | −70 °C to +150 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Stability | ±0.3 °C |
| Heating Rate | ~60 min (−70 °C → +100 °C) |
| Cooling Rate | ~90 min (+20 °C → −70 °C) |
| Humidity Range | 20–98% RH (optional low-humidity configuration down to 5% RH) |
| Humidity Uniformity | ±3% RH |
| Humidity Stability | ±2.5% RH |
| Control System | PID + SSR/SCR bidirectional output with slope logic |
| Programmability | 150 programs × 1500 segments, 9999 cycles × 999 repeats |
| Safety Monitoring | 15-point real-time fault detection with auto-diagnostic logging |
| Refrigerant | R404A / R507 (eco-friendly) |
| Compressor | Tecumseh (France) |
| Construction | SUS#304 stainless steel interior & exterior |
| Insulation | Rock wool + rigid polyurethane foam |
| Power Supply | AC 220 V / 380 V ±10%, 50/60 Hz |
| Yuelian PW-H03F Adhesion Tester for Transdermal Patches — Compliant with Chinese Pharmacopoeia Chapter 0952 (Method IV | Adhesive Force Determination) |
|---|---|
| Brand | Yuelian / PW |
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PW-H03F |
| Instrument Category | Initial Tack Tester |
| Alternate Model | PW-8801A |
| Inclination Angle Range | 0–60° |
| Test Surface Width | 120 mm |
| Effective Test Zone Width | 80 mm |
| Standard Steel Balls | 1/32″ to 1″ (ASTM E380-compliant diameters) |
| Dimensions (L×W×H) | 320 × 140 × 180 mm |
| Net Weight | 6 kg |
| Compliance Standards | ChP 2015 Vol. IV, 0952 |
| JIS Z 0237 | 2017 |
| Brand | YueLian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | PW-JC50KV |
| Max Output Voltage | 50 kV |
| Electrical Capacity | 5 kVA |
| Input Power | 220 V ±10%, 50 Hz ±1% (Single-Phase AC) |
| Voltage Ramp Modes | Constant-Rate Rise, Stepwise Rise, Hold-at-Voltage Test |
| Test Medium | Air or Insulating Oil |
| Voltage Control | Contactless Solid-State Regulator |
| Breakdown Detection | Dual-Parameter (Voltage + Current) |
| Leakage Current Range | 5–200 mA |
| Accuracy | ≤0.5% |
| Safety Protections | Integrated Arc Suppression Grid, Fuse & Earth-Leakage Circuit Breaker, Automatic Pressure Relief |
| Compliance Standards | GB 1408.1–2016, GB/T 1695–2005, GB/T 13542.4–2009, GB/T 3333–1991, HG/T 3330–2003, GB 12656–1990, ASTM D149–2022, GB/T 507–2002, DL 429.9–1991 |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | YL-S90 |
| Quotation | Upon Request |
| Load Capacity Options | 10 N, 20 N, 50 N, 100 N, 200 N, 500 N, 1 kN (dual-range configuration available) |
| Force Resolution | 1/500,000 full scale |
| Force Accuracy | ±0.3% of reading |
| Displacement Resolution | 1/500,000 full scale |
| Test Stroke | 500 mm / 800 mm (selectable) |
| Test Width | 110 mm |
| Speed Range | 0.1–500 mm/min (computer-programmable) |
| Drive System | Stepper motor + precision ground ball screw |
| Power Supply | 220 V, 50/60 Hz, 3 A |
| Power Consumption | 180 W |
| Dimensions (W×D×H) | 40 × 37 × 92 cm or 40 × 37 × 120 cm |
| Net Weight | 28 kg / 35 kg |
| Standard Accessories | One set of quick-release grips, PC software, USB-to-serial interface cable |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | RX1 Series |
| Chamber Internal Dimensions | 100 × 100 × 100 cm (W × H × D) |
| Ambient Temperature Range | Room Temperature (RT) |
| Spray Arm Radius | 0.35 m |
| Adjustable Spray Arm Length | 900–2700 mm |
| Stainless Steel Spray Pipe Diameter | 600 mm |
| Pipe Outer Diameter | 20 mm |
| Nozzle Diameter | 0.4 mm |
| Nozzle Spacing | Uniformly Distributed |
| Spray Pressure | 60–100 kPa |
| Turntable Speed | 1–10 rpm |
| Turntable Diameter | 30 mm |
| Power Rating | 1.5 kW |
| Brand | Yuelian |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-S72Q |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Load Capacity Options | 10 N to 5 kN (dual-range configuration available) |
| Force Resolution | 1 part in 500,000 |
| Force Accuracy | Better than Class 0.5 per ISO 7500-1 |
| Stroke Resolution | 1 part in 500,000 mm |
| Data Acquisition Rate | 50 Hz |
| Effective Stroke | 1000 mm |
| Speed Range | 0.001–30,000 mm/min (customizable) |
| Test Space Width | 140 mm |
| Power Supply | 220 V, 50–60 Hz |
| Motor Drive | AC Servo Motor |
| Transmission | Precision Ball Screw |
| Dimensions (W×D×H) | 520 × 590 × 1530 mm |
| Net Weight | 55 kg |
| Power Consumption | 400 W |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | GZL-B |
| Pricing | Upon Request |
| Max Operating Temperature | 1600 °C |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Temperature Sensor | Type B Platinum–Rhodium Thermocouple |
| Heating Rate | 1–15 °C/min (RT–1300 °C), 1–5 °C/min (1300–1600 °C) |
| Rated Power | ~16 kW |
| Control System | 50-Stage Programmable PID Controller with Auto-Tuning |
| Temperature Uniformity | ±1 °C (Control), ±2 °C (Soak) |
| Atmosphere Options | Air, N₂, Ar |
| Gas Flow Range | 0–10 L/min |
| Sample Dimensions | 40 × 40 × 230 mm (4 specimens per run) |
| Rotation Mechanism | Planetary motion |
| Crucible | Graphite |
| Slag Addition Port | Integrated top-access port |
| Crucible Lift | Bottom-entry vertical hydraulic/pneumatic lift mechanism |
| Brand | Guance Instruments |
|---|---|
| Model | GCZMD-10b |
| Origin | Beijing, China |
| Instrument Type | True Density Analyzer |
| Design | Portable |
| Sample Type | Solids and Liquids |
| Density Range | 0.1–20 g/cm³ |
| Maximum Sample Weight | 20 g |
| Density Resolution | 0.01 g/cm³ |
| Density Accuracy | ±0.1 g/cm³ (typical repeatability ≤0.3% RSD) |
| Measurement Principle | Gas Expansion Displacement (Helium Pycnometry) based on Boyle’s Law (PV = nRT) |
| Sample Chamber Volume | 10 mL ±0.2 mL |
| Measurement Time | ~4 min per run |
| Operating Temperature | 0–40 °C |
| Pressure Range | 1.3–2.0 bar |
| Recommended Analysis Gas | Helium (N₂ compatible with calibration adjustment) |
| Data Interface | RS485, RJ45 Ethernet, USB for U-disk storage |
| Display | Touchscreen with handwriting input |
| Power Supply | AC 220 V / 50 Hz |
| Rated Power | 28 W |
| Dimensions | 410 × 320 × 155 mm |
| Net Weight | 4.6 kg |
| Minimum Sample Mass | 0.1 g |
| Data Output | Real-time process logging + CSV export via USB |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Model | GCCLC-AII |
| Impact Energy Range | 50–300 J |
| Impact Velocity | 2–5.5 m/s |
| Pendulum Torque (Impact Constant) | 15 N·m |
| Load Cell Capacity | 16 kN |
| Maximum Lifting Height | 1500 mm |
| Temperature Chamber Range | −40 °C to +100 °C |
| System Sampling Rate | 2 MHz |
| A/D Resolution | 16-bit |
| Frequency Response | 500 kHz |
| Dynamic Test Error | <2% |
| Overall Dimensions (w/o chamber) | 850 × 1700 × 3300 mm |
| Net Weight | 1200 kg |
| Brand | Guance Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NDH-B6 |
| Price | USD 2,350 (approx.) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Standards Compliance | GB/T 1411-2002, IEC 61621:1997, ASTM D495, IEC 149, UL 746A |
| Rated Test Voltage | 12.5 kV |
| Voltage Accuracy | ±1% |
| Current Range | 10–40 mA (selectable steps) |
| Current Control Accuracy | ±3% |
| Current Measurement Accuracy | ±1.5% |
| Arc On/Off Timing Error | < ±1 ms |
| Electrode Force | 0.5 ± 0.05 N |
| Electrode Material | Tungsten Rod |
| Electrode Spacing | 6.35 ± 0.1 mm (IEC), 6.0 ± 0.1 mm (ASTM) |
| Input Power | 220 V AC, 50 Hz |
| Transformer Capacity | 3 kVA |
| Output Voltage Range | 0–17.5 kV AC |
| Operating Environment | 23 ± 2 °C, 50 ± 5 % RH |
| Brand | GuanCe Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GEST-20042I |
| Price | USD 1,550 (FOB Beijing) |
| Brand | YANRUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Vickers Hardness Tester |
| Measurement Range | 0.001–6000 HV |
| Total Test Forces | 10, 25, 50, 100, 200, 300, 500, 1000 gf |
| Standards Compliance | GB/T 4340.2, JJG 151 |
| Objective Lenses | 10×, 40× |
| Total Optical Magnification | 100×, 400× (digital zoom up to ~1600×) |
| X-Y Motorized Stage | 50 mm × 50 mm travel, 185 mm × 140 mm platform, 50 kg load capacity |
| Maximum Specimen Height | 180 mm |
| Indenter-to-Column Distance | 130 mm |
| Dwell Time | 0–60 s (1 s increments) |
| Illumination | Adjustable LED brightness |
| Data Acquisition | Encoded digital measurement |
| Software Interface | Multilingual (English, Chinese, German, Spanish, Russian) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | JC2000D |
| Pricing | Upon Request |
| Stage | Manual or Motorized 3-Axis Sample Stage |
| Dispenser | Manual Precision Syringe System (10 µL / 100 µL) |
| Camera | USB 2.0 Industrial CCD, 700 TV Lines, 25 fps |
| Optical Zoom | 0.7×–4.5× Continuous Zoom Lens (with Post-Zoom Magnification |
| Effective Pixel Resolution | 50–318 px/mm) |
| Light Source | Adjustable Monochromatic LED Cold Light |
| Tilt Platform | ±15° Manual Sample Tilting Stage (Optional) |
| Rotation Platforms | 360° Vertical & Horizontal Rotational Stages (Optional) |
| Heating Stage | Ambient to 100 °C (Optional) |
| Accessories | Fiber Holder, Fabric Stretch Frame, Insertion Plate, Sessile Drop Arrest Device (All Optional) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 3351 |
| Pricing | Upon Request |
| Density Range | 0–2 g/cm³ |
| Accuracy Class | 0.2 or 0.5 |
| Resolution | 0.0005 g/cm³ |
| Supply Voltage | 18.5–30 V DC (nominal 24 V DC) |
| Ambient Temperature | −10 to +60 °C |
| Ambient Humidity | 5–90 % RH |
| Display | Smart LCD or LED digital indicator |
| Output Signal | 4–20 mA analog with optional HART protocol |
| Mechanical Mounting | Flanged connection |
| Installation Types | Top-mount (insertion depth 850 mm) or side-mount (insertion depth 700 mm, center-to-center tap distance 500 mm, side width 150 mm) |
| Intrinsic Safety Rating | Available (per IEC 60079-11) |
| Hygienic Design Option | Available (3-A compliant, FDA-compatible wetted materials) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | HS-100 / DHS-100 |
| Internal Volume | 100 L |
| Interior Dimensions (W×D×H) | 400 × 500 × 500 mm |
| Temperature Range | HS-type: RT+10°C to 100°C |
| DHS-type | 0°C to 100°C |
| Humidity Range | HS-type: 85–98% RH |
| DHS-type | 45–98% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Humidification Method | Shallow-water tray evaporation (surface evaporation) |
| Construction | Stainless steel inner chamber, polyurethane foam insulation |
| Cooling System | Finned stainless steel heat exchanger with multi-stage evaporator |
| Refrigeration Options | Single-stage or cascade (dual-stage) refrigeration (air-cooled or water-cooled) |
| Compressor | Imported hermetic scroll compressor |
| Controller | Fuji Electric PID temperature & humidity controller (Japan) |
| Sensors | Imported high-accuracy capacitive RH sensor and Pt100 temperature probe |
| Safety Protections | Leakage current protection, low-water-level cutoff, overtemperature cutoff, fast-acting fuse, compressor high-pressure protection |
| Test Conditions | All specifications measured at ambient temperature (QT) = 25°C, empty chamber, steady-state operation |
| Brand | SINOTEST |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Series | ML Series |
| Actuation Type | Electro-Hydraulic Servo Fatigue Actuator |
| Maximum Test Force | 10–1000 kN |
| Frequency Range | 0.01–400 Hz |
| Host Weight | 35–1380 kg |
| Operating Pressure | 21–28 MPa |
| Peak Velocity (Standard) | 20 m/s |
| Bearing Type | Hydrostatic Journal Bearing (Sealless) |
| Compliance | ISO 6892-1, ASTM E4, ASTM E606, ASTM E2207 |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | P2+ |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #305 |
| Instrument Type | Portable Mechanical Impact Tester |
| Measuring Range | 0–90 N (continuously adjustable) |
| Indentor Diameter | 5 mm |
| Unstretched Length | 245 mm |
| Net Weight | Instrument: ~340 g |
| Enamel Test Plate Holder | ~25 g |
| Plastic Surface Test Fixture (Ø120 mm) | ~3000 g |
| Actuation Mechanism | Mechanical Spring-Loaded |
| Locking Mechanism | Mechanical Latch |
| Compliance | DIN 51155 |
| Brand | ERICHSEN |
|---|---|
| Origin | Germany |
| Model | 430P-I |
| Compliance | DIN 53151, ISO 2409, ASTM D3359, JIS K5400, SNV 37111, SIS 184172, ECCA T6, GME 60280 |
| Drive System | PLC-controlled with independent stepper motors for sample transport, blade positioning, and pressure actuation |
| Cutting Speed | 40 mm/s (fixed) |
| Applied Force Range | 1–50 N (standard), 1–10 N via optional weight set (1 N increments) |
| Blade Travel Length | Configurable up to 40 mm in 0.5 mm increments |
| Grid Patterns | 9 pre-programmed cross-cut configurations + 1 user-defined pattern |
| Blade Types | Hard metal tip (standard) |
| optional spherical indenters | Ø0.5 mm, Ø0.75 mm, Ø1 mm, Ø3 mm |
| Visual Assessment Tools | 2.5× magnifier included |
| Origin | Germany |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | #497 |
| Pricing | Upon Request |
| Measurement Range | 0–1000 µm |
| Resolution | 1 µm |
| Accuracy | ±1 µm |
| Measuring Force | 1.2 N (≈0.04 N/mm²) |
| Anvil Diameter | Ø6 mm (Contact Area ≈30 mm²) |
| Throat Depth | 30 mm |
| Net Weight | ~100 g |
| Origin | Germany |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | #460FC |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | #527 |
| Pricing | Upon Request |