Pipette
Filter
Showing 151–180 of 294 results
| Brand | Rainin |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E4 XLS+ |
| Instrument Type | Multichannel Pipette |
| Automation Level | Electronic Pipette |
| Channels | 8 |
| Volume Range | 1–300 µL |
| Maximum Capacity | 300 µL |
| Accuracy | ±1.0% at 0.2 µL, ±0.8% at 1.6 µL |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | E4-10XLS+, E4-20XLS+, E4-1000XLS+ |
| Volume Range | 0.5–1000 µL |
| Max Capacity | 1000 µL |
| Accuracy | ±1% at 10 µL, ±0.8% at 8.0 µL |
| Display | Full-color high-resolution LCD |
| Control | Ergonomic joystick + rotary navigation dial |
| Calibration | Auto-zero reset after each dispense |
| Motor | 4,000-step precision stepper motor |
| Battery | Rechargeable Li-ion, >1,000 cycles, full-day operation |
| Compliance | GLP/GMP-ready, password-protected settings & service logs, tamper-proof audit trail |
| Tip Ejection Force | 0.6 kg (LTS system) |
| Software Integration | PureSpeed™ pre-installed, compatible with Rainin Liquid Handling Suite (LHS) |
| Brand | Rainin |
|---|---|
| Origin | USA |
| Model | LA6-300XLS / LA8-50XLS / LA8-1200XLS |
| Automation Level | Manual |
| Channels | 6 or 8 |
| Volume Range | 20 µL – 1,200 µL |
| Max Capacity | 1,200 µL |
| Accuracy | ±0.8 % at 50 µL, ±0.8 % at 300 µL, ±0.8 % at 1,200 µL |
| Channel Spacing Adjustment Range | 9–19 mm (6-channel), 9–14 mm (8-channel) |
| Tip System | LTS (Low Retention Standard) |
| Compliance | ISO 8655-2:2022, USP <1251>, GLP/GMP-ready documentation support |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Liquidator™ 96 |
| Instrument Type | 96-Channel Manual Pipettor |
| Automation Level | Manual (Non-Motorized) |
| Channel Count | 96 |
| Volume Range | 0.5–20 µL and 5–200 µL |
| Maximum Capacity | 200 µL |
| Accuracy | ±1.0% at full scale |
| Precision (CV) | ≤1.5% (typical, per ISO 8655-6) |
| Power Requirement | None (mechanical actuation only) |
| Dimensions (W×D×H) | 14.5 × 6.5 × 12.0 cm |
| Weight | 320 g |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Instrument Type | Single-Channel Manual Pipette |
| Volume Range Options | 0.1–2 µL to 1–10 mL |
| Technology | Magnetic-Assisted Piston Drive |
| Tip Ejection System | LTS (Low-Touch Tip Ejection) |
| Compliance | ISO 8655-2, ISO 8655-5, GLP/GMP-ready design |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Model | Mettler Toledo Pipet-Lite XLS+ 8-Channel Pipettor |
| Automation Level | Manual |
| Channels | 8 |
| Volume Range | 0.5–300 µL |
| Max Capacity | 300 µL |
| Accuracy | ±4% at 1 µL, ±0.8% at 50 µL, ±0.8% at 300 µL |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Model | Pipet-X |
| Type | Single-Channel Electronic Pipette Controller |
| Operating Volume Range | 0.1–100 mL |
| Power Source | Rechargeable NiMH Battery (up to 8 h continuous operation) |
| Dispensing Modes | Gravity-fed and Motor-driven |
| Filtration | Integrated 0.2 µm hydrophobic filter |
| Compatibility | Standard glass and plastic serological pipettes (Class A, ASTM E969, ISO 648) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E4 XLS+ |
| Instrument Type | Multichannel Electronic Pipette |
| Automation Level | Motorized |
| Channel Count | Adjustable (1–12 channels via interchangeable tips) |
| Volume Range | 0.5–1250 µL (model-dependent configuration) |
| Accuracy | ±0.8%–±2.0% (volume-dependent, per ISO 8655) |
| Precision (CV) | ≤0.5%–≤1.5% (volume-dependent, per ISO 8655) |
| Display | Full-color 2.4″ TFT touchscreen |
| Control Interface | Precision tactile joystick |
| Onboard Memory | ≥20 user-defined protocols |
| Compliance | GLP/GMP-ready with audit trail, password-protected settings, calibration lock, service interval alerts |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | E4-10XLS+/E4-20XLS+/E4-1000XLS+ |
| Volume Range | 0.5–1000 µL |
| Maximum Capacity | 1000 µL |
| Accuracy | ±1% at 10 µL, ±0.8% at 8.0 µL |
| Operating Principle | Motor-driven piston displacement with onboard microprocessor control |
| Display | Full-color high-resolution LCD |
| Navigation | Rotary dial + ergonomic joystick |
| Power | Rechargeable lithium-ion battery (≥1,000 pipetting cycles per charge) |
| Compliance | GLP/GMP-ready, audit-trail capable, password-protected settings and service alerts |
| Tip Ejection Force | ≤0.6 kg (LTS-compatible) |
| Calibration | Automatic zero-point reset after each pipetting cycle |
| Step Resolution | 4,000 microsteps per stroke |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Pipette Management Software & Hardware Platform |
| Model | EasyDirect |
| Automation Level | Semi-Automated Asset Tracking System |
| Compliance | Designed for GLP/GMP environments |
| Data Integrity | Audit-trail enabled, 21 CFR Part 11 compliant (with optional electronic signature module) |
| Deployment | On-premise or networked server installation |
| Integration | Compatible with METTLER TOLEDO pipettes (e.g., E4–XLS+, Rainin XLS+), third-party pipettes via manual entry or CSV import |
| User Roles | Admin, Technician, Lab Manager, QA Auditor |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Pipet-Lite XLS+ |
| Type | Single-Channel Manual Pipette |
| Sterilization | Autoclavable (full liquid end, including seals and piston) |
| RFID Integration | Yes, for GLP/GMP-compliant service and calibration traceability |
| Ergonomic Design | Low-force plunger activation, optimized grip geometry, glove-compatible volume lock |
| Tip Ejection | Reinforced high-density polymer ejector arm with one-step removal for cleaning |
| Compliance | Designed to support ISO 8655, ASTM E1154, and FDA 21 CFR Part 11–aligned laboratory documentation workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | L-10XLS+/L-20XLS+/L-100XLS+ |
| Channel Count | 1 |
| Maximum Volume | 2000 µL |
| Accuracy | ±1% at 20 µL, ±0.8% at 200 µL |
| Automation Level | Manual |
| Sterilization | Fully Autoclavable (Liquid End, Sleeve, Ejector) |
| RFID Integration | Yes (for Calibration Tracking & Inventory Management) |
| Tip Ejection System | LTS™ LightTouch System with High-Density Polymer Ejector |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | E4 XLS+ |
| Channel Configurations | 1-, 6-, 8-, and 12-channel |
| Volume Range | 0.5–10 µL, 1–10 µL, 2–20 µL, 5–50 µL, 10–100 µL, 20–200 µL, 20–300 µL, 100–1000 µL, 100–1200 µL, 200–2000 µL, 500–5000 µL, 1–10 mL, 2–20 mL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Pipet-Lite XLS+ |
| Volume Range | 0.1–20 mL (multiple fixed-volume variants) |
| Sterilization | Autoclavable (121°C, 20 min) |
| Tip Compatibility | LTS (Low-Torque Seal) and universal conical tips |
| Ergonomic Design | Integrated finger hooks, thumb cushion, internal dampening mechanism |
| Compliance | ISO 8655 compliant |
| RFID | Embedded for asset tracking |
| Channel Options | 1-, 6-, 8-, and 12-channel |
| Adjustable Spacing | 9–14 mm (8-channel), 9–19 mm (6-channel) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | Pipet-One / LTS / XLS |
| Type | Manual Single-Channel Pipettes |
| Compliance | ISO 8655, GLP/GMP-ready |
| Tip Compatibility | LTS (Low-Torque Seal) and Universal Conical |
| Calibration Support | MCP Calibration Workstation (ISO 8655-compliant) |
| Ergonomics | Optimized grip geometry, reduced tip ejection force (<15 N), adjustable volume lock |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | Single-Channel / Multi-Channel / Classic / Electronic / Manual |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic |
| Model No. | 30564095 |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Motorized |
| Channel Count | Single |
| Volume Range | 10–1000 µL |
| Maximum Capacity | 10 mL |
| Accuracy Tolerance | ±3–10% |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Pre-sterilized, Recyclable Tip Rack System |
| Material Composition | Primarily PETE (Polyethylene Terephthalate) |
| Sterilization | Gamma-irradiated, ISO 11137 compliant |
| Environmental Certification | 100% recyclable per ISO 14021 |
| Packaging Efficiency | 50% less plastic vs. conventional tip racks |
| Compressibility | High — post-use volume reduction >60% in waste stream |
| Regulatory Compliance | Meets EU Directive 2002/96/EC (WEEE) and EN 13432 for recoverability |
| Brand | Miragen |
|---|---|
| Origin | USA |
| Type | 8-Channel Electronic Pipette |
| Automation Level | Motorized |
| Volume Range | 0.2–300 µL |
| Maximum Single-Channel Capacity | 300 µL |
| Accuracy | 0.4–0.8% |
| Precision (CV) | ≤0.15–0.25% |
| Tip Compatibility | Standard conical polypropylene tips (10–300 µL range) |
| Power | Removable rechargeable Li-ion battery |
| Charging | Dock-based |
| Operating Interface | Rotary thumb wheel + tactile keypad |
| Modes | Pipette, Manual, Aspirate, Stepper |
| Compliance | Designed to meet ISO 8655-2:2022 requirements for piston-operated volumetric apparatus |
| Brand | Miragen |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MiraPette E |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Electronic (Motor-Driven) |
| Channels | 1 |
| Volume Range | 0.2–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | 0.4–1.0% |
| Precision (CV) | 0.15–0.4% |
| Increment Resolution | 0.1 µL to 0.1 mL (model-dependent) |
| Power | Removable Rechargeable Battery |
| Charging | Dock-Based |
| Brand | Nichipet (Nichiryo) |
|---|---|
| Origin | Japan |
| Type | Manual Multi-Channel Pipette |
| Channels | 8 or 12 |
| Volume Range | 0.5–10 µL, 10–100 µL, 20–200 µL, 30–300 µL |
| Maximum Capacity | 300 µL |
| Accuracy | ±0.01 µL (at lowest range) |
| Compliance | ISO 8655-2:2022, GLP-ready design |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Product Line | Nichipet Air |
| Pipette Type | Air-displacement Manual Pipette |
| Channel Configurations | Single-channel, 8-channel, 12-channel |
| Volume Range | 0.1–2 µL (ultra-low volume models) |
| Accuracy | ±3% |
| Weight Optimization | Reduced plunger force, minimized body mass, and low tip ejection force |
| Color Coding | 8 distinct pastel (macaron-style) color variants for single-channel models |
| Compliance | Designed in accordance with ISO 8655-2:2022 (Piston-operated volumetric apparatus — Part 2: Piston pipettes) and compatible with GLP/GMP workflows requiring traceable liquid handling |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet Air |
| Volume Range Options | 0.1–2 µL (Gray), 0.5–10 µL (Pink), 2–20 µL (Beige), 10–100 µL (Orange), 20–200 µL (Yellow), 100–1000 µL (Blue), 500–5000 µL (Green), 1000–10000 µL (White) |
| Increment Resolution | 0.002–10 µL (model-dependent) |
| Operating Principle | Air-displacement positive displacement hybrid mechanism with low-force plunger actuation |
| Brand | Nichipet (Nichiryo) |
|---|---|
| Origin | Japan |
| Type | Air-displacement single-channel manual pipette |
| Channels | 1 |
| Volume Range | 0.1–2 µL, 0.5–10 µL, 2–20 µL, 10–100 µL, 20–200 µL, 100–1000 µL, 500–5000 µL, 1000–10000 µL |
| Maximum Capacity | 10 mL |
| Accuracy (at lowest range) | ±0.002 µL (for 0.1–2 µL setting) |
| Weight | 70 g |
| Actuation Force Reduction | Up to 70% vs. conventional models |
| Calibration | Tool-free adjustment via volume dial and locking fixture |
| Color-Coded Volume Ranges | Yes |
| Compliance | Designed for ISO 8655-compliant operation and GLP/GMP laboratory workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet FII & VII |
| Type | Manual Single-Channel Adjustable-Volume Pipette |
| Volume Range | 10–1000 µL |
| Accuracy | ±0.5% to ±1.2% (varies by volume) |
| Coefficient of Variation (CV) | ≤0.2% to ≤0.6% (volume-dependent) |
| Tip Compatibility | BMT2-series and F-series sterile filtered tips (e.g., BMT2-SG, FSGRB, BMT2-LE, FLERB) |
| Operating Principle | Air-displacement positive displacement (FII: fixed-volume |
| VII | triple presettable volumes) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | ACCUPENSER JR |
| Instrument Type | Manual Adjustable Bottle-top Dispenser |
| Automation Level | Manual |
| Volume Range Options | 0.2–10 mL (AJ-1), 0.4–20 mL (AJ-2), 1–50 mL (AJ-5), 2–100 mL (AJ-10) |
| Minimum Increment | 0.05 mL (AJ-1), 0.1 mL (AJ-2 & AJ-5), 0.25 mL (AJ-10) |
| Coefficient of Variation (CV) | ≤0.1% |
| Bottle Compatibility | Standard 500 mL and 1 L reagent bottles (neck dimensions identical) |
| Bottle Dimensions (W × H, mm) | 75 × 210 (165), 100 × 210 (165), 146 × 210 (165) — values in parentheses indicate collapsed height when vernier head is folded |
| Materials in Contact with Liquids | Chemically resistant polymers |
| Sterilization | Autoclavable at 121°C for 20 minutes |
| Compliance | Designed to support GLP-compliant workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Custom-Made Pipettes |
| Instrument Type | Single-Channel Manual Pipette |
| Automation Level | Manual |
| Channel Count | Single |
| Volume Range | Custom-Defined (Typically 0.1–10,000 µL) |
| Accuracy & Precision | Compliant with ISO 8655 (per customer-specified calibration range) |
| Regulatory Compliance | Designed to support GLP/GMP workflows and FDA 21 CFR Part 11–aligned documentation protocols |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL2100DG |
| Type | Manual Multi-Channel Continuous Dispenser |
| Dispensing Range Options | 0.2–1.0 mL (00-21DG-1), 0.4–2.0 mL (00-21DG-2), 1.0–5.0 mL (00-21DG-5), 2.0–10.0 mL (00-21DG-10) |
| Minimum Increment | 0.01–0.10 mL depending on model |
| Display Resolution | 0.01 mL (DG-1/DG-2), 0.02 mL (DG-5), 0.10 mL (DG-10) |
| Fluid Contact Materials | PTFE, Tygon® tubing, polypropylene, Pyrex® glass, ceramic, platinum-iridium alloy |
| Housing | Impact-resistant polymer shell protecting internal glass and piston components |
| Ergonomics | Single-hand operation, lightweight design (<300 g) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL3100 |
| Pipette Type | Manual Multi-Channel Pipette |
| Volume Range Options | 0.2–1.0 mL, 0.4–2.0 mL, 1.0–5.0 mL, 2.0–10.0 mL |
| Minimum Increment | 0.1 mL (for 0.2–1.0 & 0.4–2.0 mL ranges), 0.5 mL (for 1.0–5.0 & 2.0–10.0 mL ranges) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Tip Compatibility | Nichiryo Standard Clear Tips (00-MPT-1, 00-MPT-2, 00-BMT2-X, 00-BMT2-Z) |
| Piston Material | PTFE-Coated Stainless Steel |
| Tip Packaging | 1000 or 2000 per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL5100 |
| Pipette Type | Single-Channel Manual Pipette |
| Adjustable Volume Range | 15–25 mL and 30–50 mL (via interchangeable volume adjustment tubes) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Compatible Tip Type | Nichiryo TL50 Series (e.g., 00-51TL50) |
| Tip Packaging | 50 pcs per pack |