Empowering Scientific Discovery

AnTing ZSD-2J Intelligent Automated Karl Fischer Moisture Titrator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
[Brand AnTing
Origin Shanghai, China
Model ZSD-2J
Titration Method Fully Automatic Volumetric Karl Fischer Titration
Measurement Principle Volumetric Coulometric Dual-Mode (Volumetric Mode Standard)
Moisture Range 0.01% – 100% (w/w)
Resolution 0.01 mL
Accuracy ≤2% RSD
Minimum Dispensing Volume Auto-controlled by Precision Burette Drive
Endpoint Detection Resistive (3 selectable thresholds: 500 Ω, 1.5 kΩ, 2 kΩ)
Endpoint Delay Adjustable 10–300 s
Stirring Control PWM-driven Stepless Speed Regulation
System Sealing Closed-loop Reagent Handling with Auto Solvent Replacement & Waste Discharge
Display High-Resolution Color LCD with Full Chinese GUI]

Overview

The AnTing ZSD-2J Intelligent Automated Karl Fischer Moisture Titrator is a precision volumetric titration system engineered for reliable, trace-level water quantification in diverse sample matrices—liquids, solids, and gases—according to the internationally standardized Karl Fischer (KF) reaction principle. It implements the iodine-based redox titration chemistry where water stoichiometrically reacts with iodine, sulfur dioxide, and a base in anhydrous methanol or other KF-compatible solvents. Unlike coulometric systems optimized for sub-ppm measurements, the ZSD-2J operates primarily in volumetric mode, delivering high reproducibility across a broad dynamic range (0.01% to 100% w/w), making it especially suitable for QC laboratories in pharmaceutical manufacturing, petrochemical refining, food quality control, and agrochemical R&D. Its fully automated burette drive, closed reagent delivery path, and real-time resistive endpoint detection ensure minimal operator intervention while maintaining compliance with method validation requirements under ISO 8533, ASTM E203, and USP .

Key Features

  • High-resolution color LCD interface with intuitive Windows-style navigation and full Chinese menu support—designed for rapid method setup and operator training without documentation dependency.
  • Dual-display capability: simultaneous real-time visualization of moisture content (%), ppm concentration, absolute water mass (mg), KF reagent consumption (mL), and dynamic color-coded titration curve—enabling immediate kinetic assessment of endpoint stability.
  • Auto-compensation algorithms for ambient moisture drift: continuously monitors background drift during titration and subtracts baseline contribution in real time, enhancing measurement fidelity in non-glovebox environments.
  • PWM-controlled magnetic stirring with stepless speed adjustment via on-screen menu—ensuring homogeneous mixing across viscous oils, suspensions, and powdered samples without mechanical wear or torque limitation.
  • Fully sealed fluidic architecture: integrated three-way valve manifold enables automatic solvent replenishment, waste evacuation, and cell purging—eliminating exposure to toxic pyridine-free or imidazole-based KF reagents and supporting GLP-aligned safety protocols.
  • On-screen instrument status dashboard: live display of burette position, pump stroke count, current timestamp, three-way valve orientation, measured drift rate (µg H₂O/min), and cumulative reagent usage—facilitating audit-ready operational transparency.

Sample Compatibility & Compliance

The ZSD-2J accommodates direct analysis of low-viscosity liquids (e.g., solvents, monomers, fuels), suspended solids (via oven-coupled or homogenized extraction), and gas-phase samples (using dedicated gas sampling valves and flow controllers). It supports both single-component and multi-component KF reagents compliant with ICH Q5C and EP 2.5.12 guidelines. All firmware operations retain full traceability: every titration event logs timestamp, operator ID (if configured), method parameters, raw endpoint resistance values, drift correction applied, and final result—meeting data integrity expectations of FDA 21 CFR Part 11 when deployed with user-access controls and electronic signature modules. The system undergoes factory calibration verification per ISO/IEC 17025 principles, with certificate-of-conformance supplied.

Software & Data Management

Data handling follows a structured local storage model: all titration records—including raw sensor readings, curve derivatives, manual overrides, and audit trail metadata—are saved in encrypted binary format with CSV export capability. No cloud dependency or proprietary software installation is required; results can be exported directly to USB drives or network shares. Built-in memory retains ≥1,000 complete analyses with full parameter recall. Optional PC connectivity via RS-232 or USB-to-serial interface enables integration into LIMS environments using standard SCPI command sets. Audit trails include immutable timestamps, user login context (when password-enabled), and change history for method variables—supporting GMP-compliant review workflows.

Applications

  • Pharmaceutical: Quantification of residual moisture in active pharmaceutical ingredients (APIs), lyophilized powders, and excipients per USP and Ph. Eur. 2.5.12.
  • Petrochemical: Water determination in crude oil fractions, lubricants, and biodiesel blends per ASTM D6304 and IP 386.
  • Food & Beverage: Validation of drying endpoints in dairy powders, starches, and dehydrated vegetables; compliance with Codex Alimentarius standards.
  • Polymers & Plastics: Monitoring moisture in PET granules, polyamide resins, and epoxy precursors prior to extrusion or molding—critical for hydrolysis prevention.
  • Agricultural Chemistry: Water content verification in pesticide formulations, fertilizers, and seed coatings to ensure stability and regulatory labeling accuracy.

FAQ

What KF reagent types are compatible with the ZSD-2J?
The instrument supports standard two-component (solvent + titrant) and single-component volumetric KF reagents, including pyridine-free formulations. Compatibility is confirmed via manufacturer-specified solvent viscosity limits (<15 cP) and conductivity ranges (1–5 mS/cm).
Can the ZSD-2J be validated for GMP use?
Yes—when operated with enabled user authentication, audit trail logging, and electronic signature configuration (via optional firmware upgrade), it satisfies core elements of Annex 11 and FDA 21 CFR Part 11 for computerized system validation.
Is oven coupling supported for solid sample analysis?
The ZSD-2J does not include integrated oven hardware but provides analog/digital I/O ports for third-party oven synchronization (e.g., Halogen or Karl Fischer oven units), enabling automated moisture release and transfer per ASTM E1868.
How often does the measuring electrode require recalibration?
Electrode calibration is performed automatically during each titration via built-in reference checks; physical recalibration using certified KF standards is recommended quarterly or after 200 analyses—whichever occurs first.
Does the system support multi-language UI beyond Chinese?
The standard firmware includes only Chinese-language interface; English or other language overlays require OEM-level firmware customization and are available upon request for volume orders.