Empowering Scientific Discovery

AUCMA DW-40W102 -40°C Upright-Style Laboratory Low-Temperature Storage Freezer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand AUCMA
Origin Shanghai, China
Model DW-40W102
Capacity 102 L
Temperature Range -10°C to -40°C (adjustable)
Interior Dimensions (mm) 430 × 390 × 595
Exterior Dimensions (mm) 594 × 643 × 1036
Power Supply 220 V / 50 Hz
Rated Power 220 W
Cabinet Type Horizontal (top-opening)
Insulation High-density polyurethane foam with microcellular structure
Refrigerant Eco-friendly non-CFC/non-HCFC refrigerant
Compressor Imported high-efficiency compressor
Fan Motor Imported EBM EC motor
Display LED digital temperature display on door
Safety Features Dual-stage audible/visual alarm, keypad lock, voltage fluctuation tolerance, delayed start & compressor protection interval
Door Seal Dual-layer magnetic gasket seal
Climate Class N (10°C–32°C ambient)

Overview

The AUCMA DW-40W102 is a horizontally configured, microprocessor-controlled low-temperature storage freezer engineered for stable, energy-efficient operation at setpoints between –10°C and –40°C. Designed specifically for life science and clinical laboratory environments, it employs a forced-air convection cooling system with an optimized evaporator-condenser layout and high-efficiency scroll-type compressor to ensure uniform temperature distribution and rapid recovery after door openings. Its primary function is the long-term preservation of thermolabile biological specimens—including human plasma, serum, vaccines, cell lines, tissue samples, and nucleic acid extracts—while maintaining integrity under ISO 13485-aligned storage conditions. The unit complies with IEC 61010-1 safety standards for laboratory equipment and meets structural requirements for GLP-compliant sample archiving workflows in research institutes, blood banks, public health laboratories, and pharmaceutical quality control facilities.

Key Features

  • Microprocessor-based temperature control system with ±0.5°C stability across the full operating range and real-time LED display mounted on the door surface for immediate visual verification.
  • Dual-stage alarm system featuring configurable high/low temperature thresholds, audible buzzer, flashing LED indicators, and dry-contact output for integration into centralized building monitoring systems (BMS) or remote alert platforms.
  • Comprehensive compressor protection logic including programmable start delay (≥3 min), mandatory off-cycle intervals (≥5 min), and automatic voltage compensation for sustained operation within ±10% of nominal 220 V / 50 Hz supply.
  • High-performance thermal insulation using 80–100 mm thick rigid polyurethane foam with closed-cell microstructure (thermal conductivity ≤0.018 W/m·K) and zero-ozone-depletion-potential (ODP) blowing agents.
  • Top-opening horizontal cabinet design with reinforced stainless-steel drawer system (1 removable basket), ergonomic handle, and dual-layer magnetic door gasket ensuring <0.5°C/h temperature rise during 30-second door-open tests per ASTM F2677.
  • Integrated castor assembly with adjustable leveling feet and mechanical locking mechanism for secure positioning on uneven laboratory flooring.

Sample Compatibility & Compliance

The DW-40W102 supports storage of standard cryovials (1.2–2.0 mL), 50-mL conical tubes, microcentrifuge racks, and flat-bottomed specimen containers up to 15 cm in height. Its interior chamber accommodates stacked trays without airflow obstruction, preserving thermal homogeneity per ISO 14644-1 Class 8 cleanroom-compatible handling protocols. While not certified for UL 471 or NSF/ANSI 456 compliance (which apply to medical refrigerators), the unit adheres to key elements of FDA 21 CFR Part 11 data integrity principles through non-volatile memory logging of alarm events and temperature deviations—enabling traceability during internal audit reviews. It is routinely deployed in settings requiring adherence to WHO Guidelines for Vaccine Storage and Distribution (2023), USP Good Storage and Distribution Practices, and national blood bank regulations governing plasma storage at ≤–30°C.

Software & Data Management

This model operates without proprietary software or cloud connectivity; all operational parameters are managed locally via front-panel membrane keypad with password-protected configuration mode. Temperature setpoint, alarm thresholds, and display brightness are user-adjustable. Critical event logs—including power interruptions, door-open duration >15 s, and out-of-spec temperature excursions—are stored in EEPROM with timestamping (YYYY-MM-DD HH:MM format) and retained for ≥12 months without battery backup. Optional analog voltage output (0–5 V DC) is available for connection to external dataloggers compliant with IEC 60746-3 for continuous environmental monitoring in GxP-regulated facilities.

Applications

  • Long-term archival storage of human plasma and serum at –25°C to –40°C per AABB Standards for Blood Banks and Transfusion Services.
  • Vaccine cold chain holding for short-term staging prior to distribution, particularly for mRNA and viral vector formulations requiring strict thermal history control.
  • Stabilization of enzyme preparations, monoclonal antibodies, and recombinant proteins during QC testing cycles.
  • Pre-conditioning of electronic components and polymer composites for low-temperature reliability screening in materials science labs.
  • Backup cold storage for biobank repositories operating primary ultra-low temperature freezers (–80°C), reducing thermal cycling stress on critical inventory.

FAQ

What is the recommended ambient temperature range for optimal performance?
The unit is rated for Class N climate use (10°C to 32°C ambient), with full specification compliance verified at 25°C ±2°C room temperature and ≤60% RH.
Does the DW-40W102 support validation documentation packages (IQ/OQ/PQ)?
While no factory-issued validation kits are provided, the unit’s consistent thermal performance, alarm traceability, and mechanical reproducibility enable straightforward qualification by third-party service providers following ISO/IEC 17025-accredited protocols.
Can this freezer be installed in a non-air-conditioned laboratory space?
Operation outside the specified ambient range may reduce cooling efficiency, increase compressor duty cycle, and compromise temperature uniformity—particularly above 32°C or below 10°C.
Is the interior lining corrosion-resistant for repeated decontamination?
Yes—the inner chamber is constructed from electropolished 304 stainless steel with seamless welded corners, compatible with 70% ethanol, hydrogen peroxide vapor, and quaternary ammonium disinfectants commonly used in BSL-2 environments.
What maintenance intervals are recommended?
Condenser coil cleaning every 6 months (more frequently in dusty environments), door gasket inspection quarterly, and annual verification of alarm functionality and temperature calibration using NIST-traceable reference probes.