Empowering Scientific Discovery

CMC TMA-204-W P₂O₅ Electrolytic Trace Moisture Analyzer for Chlorine Gas

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand CMC
Origin Germany
Model TMA-204-W
Instrument Principle Phosphorus Pentoxide (P₂O₅) Electrolytic Method
Operating Temperature −10 °C to +50 °C
Accuracy ±1% of Full Scale
Repeatability ±0.1% of Full Scale
Measurement Ranges 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–2,500 ppm (Auto-ranging or Manual Selection)
Response Time (T₉₀) <1 s
T₅₀ Response <8 s
Sample Flow Rate 20 NL/h
Recommended Sample Pressure 0.1–0.5 barg
Sample Temperature 5–50 °C
Display Touchscreen with Multilingual Interface (including Chinese)
Analog Output 0/4–20 mA (configurable)
Alarm Outputs 2 Relay Outputs
Enclosure Dimensions 300 mm (W) × 260 mm (H) × 280 mm (D)
Standard Cable Length 3 m (up to 300 m optional)

Overview

The CMC TMA-204-W is a high-precision, in-line trace moisture analyzer engineered specifically for demanding applications involving highly corrosive and reactive process gases—particularly chlorine (Cl₂), hydrogen chloride (HCl), sulfur dioxide (SO₂), and hydrogen sulfide (H₂S). It employs the established phosphorus pentoxide (P₂O₅) electrolytic measurement principle, a primary standard method recognized for its absolute quantification capability without reliance on calibration gases. In this technique, moisture in the sample gas is transported across a thin, hygroscopic phosphoric acid (H₃PO₄) film deposited between two parallel electrodes—typically fabricated from platinum or rhodium—within a fused-silica cylindrical cell. An applied DC voltage drives the electrolysis of adsorbed water into hydrogen and oxygen, regenerating P₂O₅. The resulting electrolytic current is stoichiometrically proportional to the mass flow rate of water vapor, enabling direct, drift-free concentration calculation in parts per million by volume (ppmv). Unlike optical or capacitive methods, this electrochemical approach delivers intrinsic stability, immunity to interfering gas species (with few exceptions), and long-term measurement integrity—critical for purity assurance in semiconductor-grade gas supply, chlor-alkali production, and high-purity specialty chemical synthesis.

Key Features

  • True absolute measurement principle—no periodic recalibration required under stable operating conditions
  • Integrated sensor regeneration capability for rapid recovery after exposure to transient moisture excursions
  • Microprocessor-controlled auto-ranging architecture supporting four selectable full-scale ranges: 0–10, 0–100, 0–1,000, and 0–2,500 ppmv
  • Sub-second T₉₀ response time (<1 s) and fast T₅₀ (<8 s), enabling real-time process feedback and closed-loop control integration
  • Rugged fused-silica sensor cell with noble-metal electrodes optimized for chemical resistance in aggressive halogen environments
  • Self-diagnostics at power-on and continuous internal health monitoring per NAMUR NE 43 guidelines
  • Wide operational ambient temperature range (−10 °C to +50 °C) with integrated thermal stabilization for consistent electrochemical performance
  • Configurable 4–20 mA analog output with HART-compatible digital overlay and two independent relay outputs for alarm or interlock signaling

Sample Compatibility & Compliance

The TMA-204-W is validated for continuous analysis of ultra-dry industrial gases including Cl₂, HCl, SO₂, H₂S, SF₆, CO₂, CH₄, natural gas, and inert gases (He, Ne, Ar, Kr, Xe). Its P₂O₅ sensor exhibits minimal cross-sensitivity to common matrix components, though gases that chemically react with phosphoric acid (e.g., strong bases or reducing agents with high reactivity toward P₂O₅) require case-specific validation. The analyzer complies with NAMUR standards for signal transmission and fault signaling (NE 43, NE 21), supports SIL 2 functional safety considerations when integrated into safety instrumented systems (SIS), and meets EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. While not intrinsically safe certified, it may be deployed in Zone 2 classified areas when installed with appropriate barrier systems per IEC 60079-11.

Software & Data Management

The embedded touchscreen interface provides intuitive local operation with multilingual support—including English, German, French, and Chinese—and stores up to 30 days of timestamped measurement data (1-min intervals) internally. Data export is supported via USB port in CSV format for offline trending and audit review. The 4–20 mA output is fully scalable and linearized across the active range, and both relay alarms are programmable for high/low limit, deviation, or rate-of-change conditions. Optional Modbus RTU over RS-485 enables integration into DCS/SCADA platforms. All configuration changes, alarm events, and diagnostic logs are time-stamped and retained—supporting GLP-compliant recordkeeping and facilitating FDA 21 CFR Part 11 readiness when paired with validated external data acquisition systems.

Applications

  • Real-time moisture monitoring in chlorine liquefaction and cylinder-filling lines for ISO 8573-1 Class 1.2 purity compliance
  • In-line verification of desiccant dryer efficiency upstream of electrolytic hydrogen production units
  • Quality assurance in SF₆ reclamation systems for high-voltage switchgear maintenance
  • Process gas purity control in semiconductor front-end fabrication (e.g., Cl₂ etch gas delivery)
  • Moisture leak detection in sealed high-purity gas distribution networks (e.g., bulk argon or nitrogen supply)
  • Regulatory reporting for EPA Method 204 and ASTM D7443 compliance in hazardous waste incineration off-gas streams

FAQ

Is the TMA-204-W suitable for measuring moisture in wet chlorine gas containing condensable hydrochloric acid mist?

Yes—the sensor design includes heated sample path components (optional) and corrosion-resistant wetted materials (e.g., Hastelloy C-276 inlet fittings) to handle acidic aerosols; however, mechanical filtration and coalescing pre-treatment are recommended to prevent liquid carryover.
Does the P₂O₅ sensor require periodic replacement, or can it be regenerated indefinitely?

The sensor electrode assembly is field-replaceable, and the P₂O₅ film is continuously regenerated during normal operation; typical service life exceeds 24 months under continuous Cl₂ service at <10 ppmv. Regeneration cycles extend longevity but do not eliminate eventual degradation due to cumulative chemical exposure.
Can the analyzer be validated per ISO/IEC 17025 requirements?

Yes—its absolute measurement principle, documented uncertainty budget (±1% FS), and traceable factory calibration against NIST-traceable dew point standards enable formal method validation and participation in accredited laboratory proficiency testing programs.
What is the minimum detectable moisture level in the 0–10 ppm range?

The effective resolution is 0.01 ppmv, with noise-limited detection threshold below 0.05 ppmv under stabilized flow and temperature conditions.
Is remote firmware update supported?

Firmware updates require physical USB connection and authorized service credentials; no over-the-air (OTA) capability is provided to ensure system integrity and regulatory compliance in validated environments.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0