CMC
Filter
Showing all 30 results
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | CMC-TM-H2O |
| Product Type | In-Line Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | -20 °C to +80 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Brand | CMC |
|---|---|
| Origin | Beijing, China |
| Model | CMC-TW-H2O |
| Product Type | Online Dew Point Sampling System |
| Measurement Principle | Electrolytic (P₂O₅-based) |
| Operating Temperature | 40 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.5% of full scale |
| Sample Flow Rate | 20 or 100 NL/h |
| Operating Pressure | 0.1–1.5 barg |
| Sensor Material Options | Stainless Steel, Monel 400, Hastelloy, Glass, PFA |
| Electrode Material | Platinum or Rhodium |
| Seal Material Options | Viton, FEP, or FFKM |
| Gas Fitting | 6 mm or 1/4″ compression fitting |
| Electrical Connector | LEMO waterproof connector |
| Mounting | Vertical installation via three M4 screws |
| IP Rating | IP20 (benchtop/rack), IP65 (wall-mount) |
| Power Supply | 80–230 VAC, 50/60 Hz |
| Power Consumption | 8 W |
| Ambient Temperature Range | −10 °C to +50 °C |
| Enclosure Dimensions (benchtop) | 363 × 115 × 377 mm |
| Weight (instrument) | ~6 kg |
| Probe Dimensions | Ø43 × 120 mm |
| Probe Weight | ~300 g |
| Response Time (T₅₀) | <8 s |
| Calibration | Automatic zero and span calibration at startup |
| Output Signals | 4–20 mA / 0–20 mA / 0–10 V (user-selectable) |
| Digital Interface | RS232 |
| Relay Outputs | 2 alarm relays (230 VAC / 1 A), 5 range-indication relays, 5 external range-switching inputs |
| Display | Backlit LCD |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual support (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | High/Low (user-definable thresholds) |
| Power Supply | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Dimensions | 420 × 115 × 390 mm (W × H × D) |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-202 |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Ambient Temperature | 5–65 °C |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Dimensions (W×H×D) | 258 × 168 × 325 mm |
| Weight | ~5 kg |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-202-19"-Ex |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Environmental Operating Range | 5–65 °C |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Intrinsic Safety | Integrated Zener barrier |
| Enclosure | 19" rack-mount (482 mm W × 133 mm H × 350 mm D) |
| Cable Length | Standard 3 m, optional up to 300 m |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-202-W |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5°C to +50°C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204 |
| Product Type | Online Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −10 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–2,500 ppm (auto/manual range switching) |
| Response Time (T₅₀) | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Environmental Operating Range | 5–65 °C |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Dimensions (Desktop Unit) | 258 × 168 × 325 mm (W × H × D) |
| Weight | ~5 kg |
| Cable Standard | 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204-19" |
| Product Type | Online Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10°C to +50°C |
| Accuracy | ±1% of Full Scale |
| Repeatability | ±0.1% of Full Scale |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204-W |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Enclosure Dimensions | 310 mm (W) × 250 mm (H) × 285 mm (D) |
| Cable Length | Standard 3 m, up to 300 m optional |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-204-W-Ex |
| Product Type | In-line Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Range Options | 0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Enclosure Rating | ATEX/IECEx certified for Zone 1/21 (Ex d ia IIC T4 Ga / Ex tD A21 IP66 T80°C) |
| Dimensions | 310 × 250 × 285 mm (W × H × D) |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | iTMA-210-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppm (auto/manual range switching) |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Output | 4–20 mA analog, high/low alarm relay |
| Power | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 420 × 115 × 390 mm |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | OilQSens |
| Conductivity Range | 0.1–20,000 pS/m (Transformer Grade: 0.1–50 pS/m) |
| Dielectric Constant Range | 1.0–5.0 |
| Temperature Range | −10 °C to +70 °C |
| Sensitivity | 0.01 pS/m (conductivity), 1×10⁻⁶ (dielectric constant) |
| Accuracy | ±1% of reading ±0.5 pS/m (conductivity), ±1% ±0.0001 (dielectric constant) |
| Response Time | <45 s |
| Max Process Pressure | 60 barg @ 20 °C |
| Sensor Material | Stainless steel flow cell & fittings, aluminum sensor head |
| Communication Interfaces | RS232, LAN, WLAN, RS485, Profibus, Modbus, GSM (optional) |
| Power Supply | 90–264 VAC / 50–60 Hz or 24 VDC (optional) |
| Dimensions & Weight | Sensor: Ø70 × H103 mm, 2.70 kg |
| Communication Module | 87 × 110 × 30 mm, 0.25 kg |
| Control Unit | 210 × 250 × 165 mm, 4.45 kg |
| Software | WSens (optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-202 |
| Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | -20–80 °C |
| Accuracy | ±0.2 ppm(v) |
| Repeatability | ±0.1 ppm(v) |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppm(v), auto-ranging |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature Range | 5–150 °C |
| Ambient Temperature | 5–65 °C |
| Display | Backlit LCD |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 relay outputs |
| Cable Length | Standard 3 m, up to 300 m optional |
| Dimensions (Rack-mount) | 482 × 133 × 350 mm |
| (Wall-mount) | 300 × 260 × 280 mm |
| (Desktop) | 257 × 160 × 316 mm |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-202-19" |
| Type | Online Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10°C to +50°C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50°C |
| Ambient Temperature | 5–65°C |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Enclosure Dimensions | 482 mm (W) × 133 mm (H) × 350 mm (D) |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-202-W |
| Application | Laboratory-grade dew point analyzer for trace moisture in aggressive and inert gases |
| Principle | Phosphorus pentoxide (P₂O₅) electrolytic sensor |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Range | 0–10 / 0–100 / 0–1000 / 0–2500 ppmv (auto-ranging) |
| Response Time (T₅₀) | <8 s |
| Sample Flow Rate | 20 NL/h or 100 NL/h |
| Sample Pressure | 0.1–1.5 barg |
| Sensor Materials | 316 stainless steel, Monel 400, Hastelloy, glass, PFA |
| Electrode Material | Platinum or rhodium |
| Sealing | Viton, FEP, or FFKM |
| Electrical Interface | LEMO waterproof connector |
| Enclosure Rating | IP20 (portable/desktop/rack-mount), IP65 (wall-mount) |
| Power Supply | 80–230 VAC, 50/60 Hz |
| Power Consumption | 8 W |
| Dimensions (Portable) | 363 × 115 × 377 mm |
| Weight | ~6 kg |
| Probe Dimensions | Ø43 × 120 mm |
| Probe Weight | ~300 g |
| Analog Output | 4–20 mA / 0–20 mA / 0–10 V (user-configurable) |
| Digital Interface | RS232 |
| Alarm Outputs | 2 relay outputs (230 VAC / 1 A max) |
| Range Indication Outputs | 5 relay outputs |
| External Range Control Inputs | 5 non-isolated or isolated dry contacts |
| Auto-zero & span calibration | Yes |
| NAMUR-compliant | Yes |
| Intrinsic safety option | Integrated Zener barrier available |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-204-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | +5 to +50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | High/Low limit relays (user-definable) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Dimensions | 363 × 115 × 377 mm (W × H × D) |
| Weight | ~6 kg |
| Cable Length | Standard 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-204-P-EX |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature | -10 to 50 °C |
| Accuracy | ±0.2 °C dew point (equivalent to ±1% of full scale) |
| Repeatability | ±0.1 °C dew point |
| Detection Range | 0–10 / 100 / 1,000 / 2,500 ppmv H₂O (auto-ranging) |
| Display | Backlit LCD |
| Output | 4–20 mA or 0–10 V analog + 1 relay alarm |
| Power | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 363 × 115 × 377 mm |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-204-W |
| Instrument Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −10 °C to +50 °C |
| Accuracy | ±1% of Full Scale |
| Repeatability | ±0.1% of Full Scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1,000 ppm / 0–2,500 ppm (Auto-ranging or Manual Selection) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–50 °C |
| Display | Touchscreen with Multilingual Interface (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 Relay Outputs |
| Enclosure Dimensions | 300 mm (W) × 260 mm (H) × 280 mm (D) |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-D |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | -20 °C to +80 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppmᵥ (auto-ranging) |
| Sensitivity | 0.1% of full scale |
| Response Time | <1 s (t₉₀) |
| Sample Flow Rate | 100 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| Ambient Temperature | 5–65 °C |
| Display | Backlit LCD |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 relay outputs |
| Enclosure Type | Benchtop (257 × 160 × 316 mm) |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-P |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | -20 °C to +80 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-Ex |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 °C to 50 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Measurement Range | 0–10 / 100 / 1,000 / 2,500 ppmv H₂O (auto-ranging) |
| Display | Backlit LCD |
| Output | 4–20 mA or 0–10 V analog + 1 relay alarm |
| Power | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Enclosure Rating | IP20 |
| Dimensions | 363 × 115 × 377 mm |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-IP54 |
| Instrument Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | +5 °C to +150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto-ranging or manual selection) |
| Response Time | <1 s |
| Sample Flow Rate | 100 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including English) |
| Output | 0/4–20 mA (configurable) |
| Alarm Outputs | High/Low limit relays (user-definable thresholds) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Enclosure | Portable aluminum-framed case, IP54 rated |
| Cable Length | Standard 3 m, optional up to 300 m |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-100 |
| Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sample Flow Rate | 100 NL/h |
| Sample Gas Temperature Range | 5–50 °C |
| Operating Pressure Range | 0.1–0.5 barg |
| Electrode Material | Platinum |
| Electrode Substrate | Hastelloy |
| Sensor Cell Housing | Borosilicate Glass |
| Sealing Material | FEP |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-compatible compression fitting, Hastelloy |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-100-P |
| Type | Portable Dew Point Meter |
| Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sample Gas Flow Rate | 100 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Electrode Material | Platinum |
| Measurement Cell Material | Hastelloy |
| Housing/Carrier Material | PEEK |
| Seal Material | FEP |
| Gas Inlet Fitting | 6 mm Swagelok®-compatible compression fitting, Hastelloy |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-20 |
| Type | Portable Dew Point Analyzer |
| Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Measuring Cell Material | Hastelloy |
| Electrode Material | Platinum |
| Substrate | Glass |
| Seal Material | FEP |
| Sample Gas Flow Rate | 20 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-style compression fitting, Hastelloy |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-20-F |
| Type | Online Dew Point Analyzer |
| Principle | Electrolytic (P2O5) Sensor Technology |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sample Gas Flow Rate | 20 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Electrode Material | Platinum |
| Measurement Cell Material | Hastelloy |
| Sensor Substrate | Borosilicate Glass |
| Seal Material | FEP (Fluorinated Ethylene Propylene) |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-compatible compression fitting, Hastelloy C-276 |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-SS-P-20 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5) Method |
| Operating Temperature | 5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sensor Cell Material | Stainless Steel |
| Electrode Material | Platinum |
| Substrate | Glass |
| Seal Material | Viton |
| Sample Gas Temperature Range | 5–50 °C |
| Flow Rate | 20 NL/h |
| Operating Pressure | 0.1–0.5 barg |
| Gas Inlet Fitting | 6 mm Swagelok®-style stainless steel compression fitting |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-SS-P-20-F |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5) Method |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sensor Cell Material | Stainless Steel |
| Electrode Material | Platinum |
| Substrate | Glass |
| Sealing Ring Material | Viton |
| Sample Gas Temperature Range | 5–50 °C |
| Flow Rate | 20 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-compatible stainless steel compression fitting |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | WearSens |
| Conductivity Range | 0.1–100,000 pS/m |
| Conductivity Sensitivity | 0.1 pS/m |
| Conductivity Accuracy | ±1% of reading ±0.5 pS/m |
| Relative Permittivity Range | 1–5 |
| Relative Permittivity Sensitivity | 1×10⁻⁶ |
| Relative Permittivity Accuracy | ±1% of reading ±0.0001 |
| Response Time | <45 s |
| Oil Pressure Rating | up to 60 barg @ 20 °C |
| Oil Temperature Range | −20 °C to +65 °C |
| Ambient Temperature Range | −20 °C to +65 °C |
| Sensor Material | Stainless steel flow cell & fittings, aluminum sensor head |
| Cable | 3 m shielded (custom lengths available) |
| Connection | 1/4″ compression or 6 mm push-to-connect |
| Power Supply | 90–264 VAC, 50–60 Hz, 0.2 W |
| Dimensions & Weight | Sensor: Ø70 × H103 mm, 1.6 kg |
| Communication Unit | 110 × 87 × 30 mm, 0.25 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | CMC-TM-H2O System |
| Instrument Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | −20 °C to +80 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Sample Flow Rate | 20 NL/h or 100 NL/h |
| Operating Pressure | 0.1–1.5 barg |
| Sensor Material Options | Stainless Steel, Monel 400, Hastelloy, Glass, PFA |
| Electrode Material | Platinum or Rhodium |
| Sealing Materials | Viton, FEP, or FFKM |
| Electrical Connector | LEMO waterproof |
| Enclosure Rating | IP20 (benchtop/rack), IP65 (wall-mount) |
| Power Supply | 80–230 VAC, 50/60 Hz |
| Power Consumption | 8 W |
| Dimensions (Analyzer) | 363 × 115 × 377 mm (portable), 482 × 133 × 350 mm (19″ rack), 300 × 260 × 280 mm (wall-mount), 257 × 160 × 316 mm (desktop) |
| Weight (Analyzer) | ~6 kg |
| Probe Dimensions | Ø43 × 120 mm |
| Probe Weight | ~300 g |
| Display | Backlit LCD |
| Output Signals | 4–20 mA / 0–20 mA / 0–10 V (user-configurable) |
| Digital Interface | RS232 |
| Relay Outputs | 2 alarm relays (230 VAC / 1 A), 5 range-indication relays |
| Input | 5 external relay contacts for range switching |
| Calibration | Automatic zero and span calibration at power-on |
| Response Time (T₅₀) | <8 s |
| Measurement Range (with TMA-202/204/210) | 0–10 / 100 / 1000 / 2500 ppmᵥ |
| Measurement Range (with TMA-404) | 0–1 / 10 / 100 / 1000 ppmᵥ |
| Environmental Operating Temp. | −10 °C to +50 °C |
| Sample Gas Temp. | +5 °C to +150 °C (recommended ≤50 °C |
| Ambient Temp. (Probe) | +5 °C to +65 °C |