Esco Airstream® AB2-S Class II Type B2 Biological Safety Cabinet

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Esco
Origin Singapore
Instrument Type Class II, Type B2 Biosafety Cabinet
External Dimensions (L×W×H) 1340 × 811 × 2171 mm
Internal Dimensions (L×W×H) 1270 × 585 × 670 mm
Filter Efficiency ≥99.999% (ULPA/HEPA)

Overview

The Esco Airstream® AB2-S is a certified Class II, Type B2 biological safety cabinet engineered for total exhaust (100% external venting) operation, providing simultaneous protection for personnel, products, and the environment. Unlike recirculating Class II A2 cabinets, the AB2-S draws 100% of its inflow and downward airflow through dual-stage filtration—first via a ULPA pre-filter (per IEST-RP-CC001.3) for supply air conditioning, then through a final ULPA or HEPA filter for exhaust air—before discharging all air outdoors via dedicated ductwork. This configuration eliminates any risk of cross-contamination from recirculated air and enables safe handling of low-to-moderate risk biological agents (BSL-1 to BSL-3), volatile toxic chemicals, radionuclides, and pharmacological compounds requiring containment under negative pressure conditions. Its structural integrity is reinforced by a double-walled negative-pressure chamber surrounding the entire work area, ensuring containment integrity even during transient pressure fluctuations or filter loading.

Key Features

  • Dynamic Chamber airflow design delivers uniform, laminar, and ultra-quiet downflow (0.33 m/s) and inflow (0.53 m/s), minimizing turbulence and enhancing operator comfort during extended procedures.
  • Seamless one-piece stainless steel work surface—no welds, seams, or fasteners—to prevent microbial entrapment and simplify decontamination in compliance with ISO 14644-1 cleanroom standards.
  • Integrated Esco Sentinel™ microprocessor controller provides real-time monitoring and adjustment of airflow velocity, filter differential pressure, UV lamp cycle timing, and fault diagnostics.
  • ISOCIDE™ antimicrobial coating applied to all exposed interior surfaces inhibits bacterial colonization per ASTM E2149-20, supporting routine aseptic maintenance protocols.
  • Fail-safe exhaust failure response system automatically shuts down the main blower upon detection of duct static pressure loss or fan malfunction—maintaining negative pressure integrity and preventing unfiltered air egress.
  • Ergonomically optimized sash height and reduced front grille profile minimize operator fatigue and improve access to the work area without compromising inflow velocity or containment performance.

Sample Compatibility & Compliance

The AB2-S accommodates standard laboratory workflows involving cell culture, microbiological assays, molecular cloning, and chemical synthesis where both biological and chemical hazards coexist. It complies with NSF/ANSI 49-2022 (Class II, Type B2), EN 12469:2000, and AS/NZS 2252.2:2013 for biosafety cabinet certification. All airflow parameters are validated per ISO 14644-3 Annex B for cleanroom-compatible installations. The cabinet supports GLP/GMP-aligned documentation requirements through Sentinel™ audit-trail logging (including timestamped airflow logs, UV exposure cycles, and alarm events), facilitating FDA 21 CFR Part 11–compliant data management when integrated with enterprise LIMS platforms.

Software & Data Management

The Esco Sentinel™ controller features a high-contrast LCD interface with multilingual support (English, Spanish, French, Chinese) and password-protected parameter access levels. It records continuous airflow velocity trends, filter lifetime estimates based on differential pressure delta, and UV lamp operational hours. Data export is supported via USB port (CSV format) for integration into institutional QA/QC databases. Optional Ethernet connectivity enables remote monitoring and centralized fleet management across multi-site laboratories. All firmware updates are digitally signed and validated to ensure cybersecurity compliance per IEC 62443-3-3.

Applications

  • BSL-2 and BSL-3 research involving recombinant DNA, viral vectors, and select agents requiring chemical compatibility (e.g., ethidium bromide, formaldehyde, acrylamide).
  • Pharmaceutical QC labs performing sterility testing of parenteral formulations under ISO 13408-1–compliant conditions.
  • Environmental microbiology labs processing wastewater samples containing mixed biohazards and heavy metals.
  • Academic core facilities supporting shared-use infrastructure with strict segregation of chemical and biological workflows.
  • Hospital pathology departments conducting molecular diagnostics with concurrent hazardous reagent use.

FAQ

Does the AB2-S require dedicated ducted exhaust?
Yes. As a Type B2 cabinet, it must be connected to an externally vented duct system with balanced static pressure control to maintain certified inflow and downflow velocities.
Can the AB2-S operate without external exhaust during power failure?
No. It relies entirely on continuous mechanical exhaust; loss of power or exhaust flow triggers immediate blower shutdown and visual/audible alarms to preserve containment.
What is the expected service life of the ULPA filter?
Under typical lab usage (8 hrs/day, moderate particulate load), ULPA filters achieve 5–7 years of service life, monitored continuously via Sentinel™ differential pressure sensors.
Is the ISOCIDE™ coating EPA-registered?
ISOCIDE™ is registered under EPA Establishment No. 82051-MN-1 and conforms to EPA Pesticide Registration Standard 40 CFR Part 158 for antimicrobial surface treatments.
How does the Dynamic Chamber design improve containment verification?
By eliminating localized turbulence zones, it ensures consistent smoke pattern conformity during NSF 49 certification testing and simplifies annual recertification by third-party agencies.