GreenPrima GP8200MAS Multi-Parameter Online Water Quality Analyzer for Secondary Water Supply
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | GP8200MAS |
| Pricing | Upon Request |
| pH Range | -2.00–16.00 pH, Res: 0.01 pH, Acc: ±0.01 pH |
| Free Chlorine Range | 0–2.000 / 0–20.00 ppm, Res: 0.001 / 0.01 ppm, Acc: ±0.001 / ±0.01 ppm |
| Turbidity Range | 0–1000 NTU, Res: 0.0001 NTU (adjustable), Acc: ±2% R or ±0.02 NTU (<40 NTU), ±5% R (≥40 NTU) |
| Conductivity Range | 0.00–2000 mS/cm, Res: 0.01 mS/cm, Acc: ±1% FS |
| Dissolved Oxygen Range | 0.00–20.00 ppm, Res: 0.01 ppm, Acc: ±0.01 ppm |
| ORP Range | -2000–+2000 mV, Res: 1 mV, Acc: ±1 mV |
| Temperature Range | 0–100 °C, Res: 0.1 °C, Acc: ±0.1 °C |
| Temp Compensation | -10–130 °C (NTC10K/PT1000, manual/auto) |
| Output Options | 4–20 mA (up to 8 channels, optional), RS485 (Modbus RTU), Ethernet (optional), GPRS (China Mobile/Unicom/Telecom, optional), Wi-Fi (optional) |
| Relay Outputs | 8 × SPST, 5 A @ 250 VAC / 5 A @ 30 VDC |
| Display | 10-inch capacitive touch LCD, Chinese UI |
| Enclosure Rating | IP65 |
| Dimensions | 1300 × 600 × 400 mm (customizable) |
| Power | AC 220 V / 20 W or DC 24 V / 15 W (solar compatible) |
| Optional Features | Sample intake module, DTU-based remote data transmission, cloud platform integration (GopCloud), multi-channel alarm notification (SMS, WeChat Official Account, mobile app) |
Overview
The GreenPrima GP8200MAS is a purpose-engineered multi-parameter online water quality analyzer designed specifically for continuous monitoring of secondary water supply systems in municipal distribution networks, high-rise building pump stations, and centralized water treatment facilities. It operates on a modular, channel-isolated architecture—each sensor input functions as an independent measurement node with dedicated signal conditioning, analog-to-digital conversion, and real-time compensation algorithms. This eliminates cross-parameter interference and ensures metrological integrity across concurrent measurements of pH, free chlorine, turbidity, conductivity, dissolved oxygen (DO), oxidation-reduction potential (ORP), and temperature. The system employs maintenance-free electrochemical and optical sensing principles: potentiometric pH/ORP electrodes with automatic temperature compensation (ATC), amperometric free chlorine sensors compliant with EPA Method 334.0 principles, ISO 7027-compliant 90° scattered-light turbidimetry, four-electrode conductivity cells for high-range stability, and luminescence-based DO probes for zero-oxygen-consumption operation. All measurements are traceable to NIST-traceable calibration standards and validated under ISO/IEC 17025-aligned internal procedures.
Key Features
- Modular sensor architecture: Fully independent analog input channels per parameter—no shared circuitry or signal crosstalk
- Reagent-free operation: Eliminates chemical consumption, waste generation, and associated regulatory reporting obligations (e.g., hazardous material handling)
- Auto-compensation capability: Real-time temperature compensation for pH, conductivity, and DO using dual-sensor inputs (NTC10K or PT1000)
- Multi-protocol digital connectivity: Native Modbus RTU over RS485; optional Ethernet (TCP/IP), Wi-Fi (802.11 b/g/n), and tri-carrier GPRS (China Mobile/Unicom/Telecom) for heterogeneous network deployment
- Industrial-grade human-machine interface: 10-inch capacitive touchscreen with localized Chinese firmware, intuitive menu navigation, and embedded calibration wizards
- Configurable relay control logic: Eight SPST relays support fail-safe pump control, valve actuation, and alarm staging per user-defined thresholds (e.g., low chlorine < 0.05 ppm → activate dosing pump)
- IP65-rated enclosure: Aluminum alloy chassis with UV-stabilized polycarbonate front panel, suitable for indoor pump rooms and outdoor kiosk installations
Sample Compatibility & Compliance
The GP8200MAS is validated for continuous flow-through analysis of potable water within secondary distribution systems operating at pressures up to 1.0 MPa and temperatures from 0 °C to 40 °C (ambient) or up to 100 °C (for inline hot-water loop monitoring). Sensor modules meet GB/T 30300–2013 (Chinese national standard for online water quality analyzers), CJJ/T 271–2017 (technical specification for secondary water supply monitoring), and ISO 5667-22 for sampling and measurement uncertainty management. The system supports GLP-compliant data integrity through time-stamped audit logs, operator ID authentication, and electronic signature-capable calibration records. When deployed with optional DTU and GopCloud platform integration, it satisfies key requirements of China’s “Smart Water Network” initiative (Water Resources Ministry Notice No. 32 [2021]) and aligns with ISO 9001:2015 Clause 8.2.4 (monitoring and measuring resources).
Software & Data Management
Data acquisition is governed by an embedded Linux-based real-time OS with deterministic I/O scheduling. Measurement intervals are configurable from 1 second to 24 hours per parameter. All raw and compensated values are timestamped with microsecond precision and stored locally in non-volatile memory (≥30 days at 1-minute logging). Remote access is enabled via GopCloud—a secure, ISO 27001-aligned SaaS platform supporting role-based dashboards, historical trend visualization (up to 10 years), automated PDF report generation (daily/weekly/monthly), and configurable alarm escalation workflows. The platform complies with China’s Cybersecurity Law (CSL) Article 37 for domestic data residency and supports optional 21 CFR Part 11-style electronic record controls—including audit trails, user access levels, and digital signatures—for regulated utility environments requiring FDA-equivalent validation.
Applications
- Real-time compliance monitoring at secondary water supply pump stations to verify residual chlorine ≥ 0.05 ppm and turbidity ≤ 1 NTU per GB 5749–2022 (Drinking Water Quality Standards)
- Early detection of biofilm formation or pipe corrosion via synchronized trends in pH drift, ORP decline, and conductivity rise
- Performance verification of UV disinfection units through pre- and post-UV free chlorine decay profiling
- Energy optimization of variable-frequency drive (VFD) pumps using conductivity- and temperature-derived density corrections
- Integration into SCADA systems for municipal water bureaus via Modbus TCP or OPC UA (via gateway)
- Remote asset health monitoring for property management firms operating multiple high-rise residential complexes
FAQ
Does the GP8200MAS require routine reagent replacement or wet chemistry?
No. All parameters are measured using solid-state electrochemical and optical transducers—zero liquid reagents, zero consumables beyond periodic sensor cleaning and annual calibration verification.
Can sensor modules be replaced or upgraded without system downtime?
Yes. Hot-swappable sensor cartridges with plug-and-play M12 connectors allow field replacement in under 90 seconds without power cycling or firmware reconfiguration.
Is the system certified for use in explosion-hazardous areas?
No. The GP8200MAS is rated for general-purpose indoor/outdoor use (IP65). For Zone 1/2 hazardous locations, consult GreenPrima’s intrinsically safe variant GP8200MAS-Ex (certified to GB 3836.4–2021).
How is data security ensured during GPRS/Ethernet transmission?
All remote communications use TLS 1.2+ encryption; device authentication employs X.509 certificates; and cloud API endpoints enforce OAuth 2.0 token-based authorization with session timeout and brute-force lockout.
What calibration standards and frequency are recommended?
pH: NIST-traceable buffer solutions (4.01, 7.00, 10.01) every 30 days; free chlorine: DPD colorimetric verification per HJ 588–2010 monthly; turbidity: Formazin or AMCO AEPA standards quarterly. Full calibration logs are exportable as CSV or PDF.