Origin Shandong, China
Manufacturer Type Authorized Distributor
Origin Category Domestic (PRC)
Model DW-86W100
Pricing Upon Request
Climate Class N
Cooling Method Direct Cool
Defrost Mode Manual
Refrigerant Mixed HFC-free Blend
Noise Level <49 dB(A)
Power Consumption 1200 W
Voltage/Frequency 220 V / 50 Hz
Internal Temp Range –40 °C to –86 °C
Uniformity <4 °C (at 32 °C ambient)
External Dimensions (W×D×H) 769 × 825 × 1120 mm
Internal Dimensions (W×D×H) 470 × 450 × 480 mm
Net Volume 100 L
Weight 138 kg
Control System Microprocessor-based Digital Controller
Temp Resolution 1 °C
Display LED Numeric
Exterior Material Pre-painted Steel
Interior Material Galvanized Steel with Epoxy Coating
Insulation VIP Panels + HFC-free Polyurethane Foam
Compressor Dual Hermetic Reciprocating Units (253 W each)
Door Configuration Single Outer & Inner Foamed Doors
Door Lock Integrated Mechanical Latch (No Padlock Interface)
Storage Capacity 72 × 2" Cryoboxes
Casters Equipped with Locking Swivel Casters
Leveling Feet Adjustable
Monitoring Port 1 × Ø6 mm Access Port
Temperature Sensor Precision NTC Thermistor
Alarm System Comprehensive Multi-Event Detection (High/Low Temp, Power Failure, Voltage Anomaly, Sensor Fault, Filter Clogging, Ambient Over-Temp, Low Battery, Delayed Start Protection)
Security Password-Protected Display Interface
Regulatory Compliance Registered Medical Device (China NMPA), CCC Certified, CE Marked (EN 61000-6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3)

Overview

The Haier DW-86W100 is a compact, high-efficiency ultra low temperature (ULT) freezer engineered for reliable long-term cryopreservation of biological samples—including primary cells, stem cell lines, plasma, serum, DNA/RNA extracts, and tissue specimens—in research laboratories, biobanks, clinical diagnostics facilities, and pharmaceutical QC environments. Operating within a stable temperature range of –40 °C to –86 °C at ambient conditions up to 32 °C, the unit employs a dual-compressor direct-cooling architecture with mixed HFC-free refrigerants to achieve rapid pull-down and maintain thermal uniformity (<4 °C) across its 100 L internal chamber. Its卧式 (horizontal) configuration minimizes floor footprint while optimizing ergonomic access—critical in space-constrained cleanrooms or shared core facilities. The cabinet integrates vacuum-insulated panels (VIPs) and environmentally compliant polyurethane foam, delivering superior thermal resistance without ozone-depleting substances or high-global-warming-potential (GWP) agents.

Key Features

  • Dual-Compressor Redundancy: Two independent hermetic reciprocating compressors (253 W each) enable load-sharing operation, extended service life, and improved reliability during continuous 24/7 operation.
  • Acoustic Optimization: Vibration-dampened refrigeration circuitry and reinforced cabinetry reduce operational noise to <49 dB(A), meeting ISO 7779 requirements for quiet laboratory environments.
  • Intelligent Microprocessor Control: Digital PID-based temperature regulation with 1 °C resolution, real-time LED display, and password-protected interface ensures traceable, tamper-resistant setpoint management.
  • Multi-Layer Alarm Architecture: Comprehensive event detection includes high/low temperature deviation, power interruption, voltage fluctuation (>±10%), sensor failure, ambient over-temperature, clogged air filter, low backup battery, and startup delay protection—all configurable via front-panel menu.
  • Medical-Grade Construction: Internally lined with epoxy-coated galvanized steel; exterior finished with corrosion-resistant pre-painted steel; door gaskets designed for low-permeability sealing under prolonged sub-zero cycling.
  • Modular Service Design: Separated refrigeration and electronic control modules simplify field diagnostics, component replacement, and preventive maintenance—reducing mean time to repair (MTTR).

Sample Compatibility & Compliance

The DW-86W100 accommodates standard cryogenic storage configurations: up to 72 two-inch cryoboxes mounted on removable, label-compatible racks. Its interior geometry (470 × 450 × 480 mm) supports both manual and semi-automated retrieval workflows. As a registered Class II medical device in China (NMPA registration number available upon request), it complies with GB/T 20154–2014 (Technical Requirements for Ultra-Low Temperature Freezers) and meets essential safety and EMC criteria per CCC (GB 4706.1, GB 4706.13) and CE directives (2014/30/EU, 2014/35/EU). While not certified to ISO 13485 or FDA 21 CFR Part 11 out-of-the-box, its alarm logs, password protection, and optional USB data logger (sold separately) support alignment with GLP/GMP documentation practices when integrated into validated lab infrastructure.

Software & Data Management

The unit operates autonomously without proprietary software dependency. All operational parameters—including setpoint, real-time chamber temperature, alarm history (timestamped), and system status—are accessible via the front-panel interface. Optional accessories include a USB-enabled temperature data logger (recording interval configurable from 1 to 60 minutes) and analog/digital output modules for integration with building management systems (BMS) or centralized environmental monitoring platforms. No cloud connectivity or remote web interface is embedded; however, the “remote alarm” function provides dry-contact relay outputs (NO/NC) compatible with third-party alarm consolidation servers or facility-wide notification systems (e.g., SMS/email gateways via external PLC).

Applications

  • Long-term archival storage of human biospecimens in biorepositories accredited to ISBER Best Practices.
  • Cryopreservation of induced pluripotent stem cells (iPSCs) and primary neuronal cultures requiring strict thermal stability.
  • Stabilization of thermolabile reagents, monoclonal antibodies, and reference standards in QC/QA laboratories.
  • Backup cold chain for vaccine development workflows operating under WHO PQ or USP environmental controls.
  • Supporting ISO/IEC 17025-accredited testing labs where documented temperature continuity and alarm response protocols are mandatory.

FAQ

What is the minimum ambient temperature required for stable –86 °C operation?
The unit is rated for climate class N (18–32 °C ambient); performance validation confirms sustained –86 °C operation at 32 °C ambient with <4 °C internal uniformity.
Is the freezer suitable for GMP-regulated environments?
While not pre-validated, its alarm logging, password protection, and optional data recording accessories enable integration into IQ/OQ/PQ protocols under user-defined qualification frameworks.
Can the unit be installed in an unventilated closet?
No—adequate rear and side clearance (≥100 mm) and unrestricted airflow around condenser coils are mandatory to prevent overheating and compressor overload.
Does it support LN2 or CO2 backup systems?
Yes—both liquid nitrogen and CO2 emergency backup interfaces are available as factory-installed options (requires separate ordering and site-specific engineering review).
Are calibration certificates provided with shipment?
Factory calibration verification is performed pre-shipment; NIST-traceable calibration certificates and IQ/OQ documentation packages are available as add-on services.