Empowering Scientific Discovery

HUANKONG GHD-CY10D Portable Battery-Powered Impact Soil Sampler

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HUANKONG
Origin Shandong, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model GHD-CY10D
Power Source Rechargeable Lithium-ion Battery
Sampling Principle Impact-driven Core Penetration
Max Sampling Depth 1.5 m (soft soils), 1.0 m (standard soils)
Weight <6 kg
Core Diameter Standard 50 mm (compatible with common soil liners)
Sample Integrity Intact undisturbed cylindrical core retrieval
Compliance Designed for ASTM D1586, ISO 22475-1, and GB/T 22103–2008 soil sampling protocols

Overview

The HUANKONG GHD-CY10D is a portable, battery-powered impact soil sampler engineered for high-fidelity, minimally disturbed in-situ soil core collection. Unlike auger- or push-based samplers that induce shear deformation or compaction, the GHD-CY10D employs a controlled vertical impact mechanism—driving a hollow stainless-steel sampling tube into the ground via rapid kinetic energy transfer. This principle ensures minimal lateral displacement and preserves natural soil stratification, pore structure, and moisture distribution within the retrieved core. The device is specifically calibrated for field deployment across heterogeneous terrain, including loam, clay, silt, and moderately compacted sandy soils. Its lightweight architecture (<6 kg) and modular design enable rapid assembly and disassembly without tools, supporting single-operator workflows in remote or off-grid locations where access to AC power or generators is impractical.

Key Features

  • Battery-operated operation using a high-capacity, field-replaceable lithium-ion pack—enabling >80 full-depth sampling cycles per charge under typical conditions.
  • Impact-driven penetration system with adjustable stroke height and repeatable hammer mass, delivering consistent energy input to minimize operator-dependent variability.
  • Standard 50 mm outer diameter sampling tube with integrated columnar liner sleeve—ensuring secure containment of intact cores during extraction, transport, and laboratory handling.
  • Ergonomic handle geometry and low center-of-gravity design reduce operator fatigue during repetitive use over extended survey periods.
  • Modular quick-connect interface between drive head, extension rods, and sampling tube—facilitating rapid adaptation to varying depth requirements and soil resistance profiles.
  • Corrosion-resistant stainless-steel construction compliant with ISO 9223 C3 environmental exposure classification for long-term durability in humid, saline, or acidic field conditions.

Sample Compatibility & Compliance

The GHD-CY10D is validated for retrieval of continuous, undisturbed cylindrical soil cores up to 1.5 m in soft alluvial or organic-rich topsoil layers and 1.0 m in denser subsoils or weathered parent material. It meets mechanical performance criteria outlined in ASTM D1586 (Standard Test Method for Penetration Test and Split-Barrel Sampling of Soils) and ISO 22475-1 (Geotechnical Investigation and Testing — Sampling Methods and Equipment — Part 1: General Principles). For regulatory soil monitoring programs—including those governed by EPA Region 10 protocols, EU Soil Thematic Strategy reporting frameworks, or Chinese GB/T 22103–2008 standards—the sampler supports traceable sample integrity through documented core recovery ratios and liner-sealed transport. Optional calibration certificates are available upon request for GLP-aligned field campaigns.

Software & Data Management

While the GHD-CY10D operates as a standalone mechanical instrument, it integrates seamlessly into digital field data ecosystems. Each sampling event can be geotagged and logged via companion mobile applications (e.g., ESRI Field Maps or QGIS Mobile) using Bluetooth-enabled GNSS receivers. Core metadata—including GPS coordinates, timestamp, depth increment, soil description codes (USDA texture class), and liner batch ID—is structured to comply with ISO 11464 (Soil Quality — Vocabulary) and FAO World Reference Base (WRB) classification inputs. Audit trails generated during sample chain-of-custody workflows align with 21 CFR Part 11 requirements when paired with validated electronic lab notebooks (ELNs) used in accredited environmental testing laboratories.

Applications

  • Environmental site assessments requiring undisturbed vadose zone profiling for contaminant migration modeling.
  • Agricultural soil health monitoring—including bulk density, root zone compaction, and organic carbon stratification analysis.
  • Geotechnical reconnaissance for infrastructure planning, where intact shear strength and moisture content gradients must be preserved.
  • Ecological restoration projects assessing pre- and post-intervention soil horizon integrity and microbial habitat continuity.
  • Long-term ecological research networks (e.g., LTER, ILTER) requiring inter-site comparability of physical soil properties.
  • Regulatory compliance sampling for landfill cover systems, brownfield redevelopment, and pesticide leaching studies.

FAQ

What soil types is the GHD-CY10D optimized for?
It performs reliably in cohesive soils (clays, silts) and granular soils (sands, loams) with standard penetration resistance up to N-value ≈ 25 (ASTM D1586). Performance in gravelly or highly cemented layers may require pre-augering or alternative methods.
Does the sampler include depth measurement capability?
Yes—graduated extension rods with millimeter-scale刻度 (metric scale) markings allow real-time visual depth tracking; optional digital depth sensor add-ons are compatible via threaded rod interface.
How is sample contamination prevented during retrieval?
The columnar liner system isolates the core from external contact throughout extraction and transport, eliminating cross-layer smearing and minimizing oxidation of redox-sensitive horizons.
Is the lithium battery certified for air transport?
The integrated battery complies with IATA Dangerous Goods Regulations Section II for lithium-ion cells ≤100 Wh, enabling safe shipment via commercial carriers without special permits.
Can replacement liners be sourced internationally?
Standard 50 mm polypropylene and PVC liners conform to ASTM D3551 specifications and are globally distributed through authorized environmental supply channels.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0