Jianhu UV Aging Test Chamber DV-540H for Photovoltaic Material Testing

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Jianhu
Origin Shanghai, China
Manufacturer Type Authorized Distributor
Product Category Domestic
Model DV-540H
Price Range USD 1,350 – 13,500 (FOB Shanghai)
Humidity Range ≥95% RH (in-chamber actual value)
Lamp Power 40 W per tube
Irradiance Range 0.72 W/m² (at 340 nm reference wavelength)
Exposure Time 1–9999 h (programmable)
Air Temperature Range RT+10°C to 80°C (adjustable)
Black Panel Temperature Range 40°C to 80°C (adjustable)
UV Wavelength Range 280–400 nm (full-spectrum
Chamber Internal Dimensions (L×W×H) 900 × 600 × 500 mm (540 L)

Overview

The Jianhu UV Aging Test Chamber DV-540H is an engineered environmental test system designed specifically for accelerated durability evaluation of photovoltaic (PV) materials under controlled ultraviolet irradiation, temperature, and humidity conditions. It operates on the principle of xenon-arc or fluorescent UV lamp-based photochemical degradation simulation—configured here with UVA-340 lamps calibrated to replicate the critical short-wavelength solar UV spectrum (280–340 nm) responsible for polymer chain scission, yellowing, and interfacial delamination in encapsulants, backsheets, and frontsheet films. Unlike generic UV chambers, the DV-540H delivers a stable, traceable irradiance of 0.72 W/m² at 340 nm—a level aligned with ASTM G154 Cycle 1 and IEC 61215-2 MQT03 requirements for PV module qualification. Its 540 L working volume accommodates full-size PV mini-modules (up to 1.2 m × 0.6 m), while dual independent control loops maintain precise coupling between radiant flux, black panel temperature (BPT), and relative humidity—enabling reproducible acceleration factors exceeding 10× natural exposure under standardized test protocols.

Key Features

  • High-intensity UV irradiation system with calibrated UVA-340 fluorescent lamps (40 W per lamp), delivering 0.72 W/m² @ 340 nm—certified per ISO 4892-3 Annex B and ASTM G154 Section 7.3
  • Independent dual-loop climate control: air temperature (RT+10°C to 80°C, ±0.5°C stability) and black panel temperature (40°C to 80°C, ±1.0°C accuracy), monitored via calibrated thermocouples per ASTM D7892
  • Humidity regulation up to ≥95% RH (actual in-chamber value), achieved via integrated steam generator and condensate management—compliant with IEC 61215-2 MQT10 humidity cycling profiles
  • Programmable multi-stage test sequences including UV irradiation, dark condensation (simulated dew formation), and optional light/dark thermal cycling—supporting IEC 61215-2 MQT03, MQT10, and UL 1703 Annex B
  • Stainless-steel 316L chamber interior with quartz glass viewing window, UV-stabilized insulation, and over-temperature/over-humidity safety cutoffs per IEC 61000-6-2 EMC and UL 61010-1
  • Modular lamp array design allowing individual tube replacement without system shutdown; lamp life monitored and logged automatically

Sample Compatibility & Compliance

The DV-540H accepts flat-panel specimens up to 1200 mm × 600 mm × 50 mm, accommodating standard PV encapsulant sheets (EVA, POE), backsheet laminates (PET/fluoropolymer), anti-reflective coatings, and thin-film substrate stacks. Fixtures are non-reactive (anodized aluminum or PTFE-coated stainless steel) to prevent catalytic interference. All operational parameters—including irradiance, BPT, RH, and cycle timing—are traceable to NIST-traceable calibrations and documented per ISO/IEC 17025 requirements. The system supports audit-ready data generation compliant with FDA 21 CFR Part 11 (electronic records/signatures), GLP, and GMP environments when paired with optional validation packages (IQ/OQ/PQ documentation available). It meets the essential performance criteria of IEC 61215-2, UL 1703, ASTM D4329, and GB/T 16422.3.

Software & Data Management

Equipped with Jianhu’s proprietary WinTest Pro v4.2 control software (Windows 10/11 compatible), the DV-540H enables real-time monitoring of all critical parameters via graphical trend plots, alarm logging, and event-triggered data capture. Users define multi-step test programs using drag-and-drop sequencing, with automatic irradiance compensation based on lamp aging algorithms. All sensor readings—including UV radiometer output, BPT, chamber RH, and ambient temperature—are timestamped and exported in CSV or XML format for integration into LIMS or statistical analysis platforms (e.g., JMP, Minitab). Audit trails record operator actions, parameter changes, and calibration events. Optional 21 CFR Part 11 compliance module provides electronic signatures, role-based access control, and immutable record archiving.

Applications

  • Accelerated weathering validation of ethylene-vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants per IEC 61215-2 MQT03
  • Durability screening of fluoropolymer-based backsheets (e.g., Tedlar® PVF, PVDF) under high-humidity UV stress per UL 1703 Annex B
  • Interfacial adhesion stability testing of glass/EVA/backsheet laminates during combined UV + thermal + humidity exposure
  • Optical transmittance loss quantification in AR-coated front glasses using in-situ spectrophotometric correlation (requires optional external spectrometer interface)
  • Qualification of novel perovskite encapsulation barriers under low-dose, long-duration UV + moisture ingress protocols
  • Supporting R&D for next-generation bifacial modules where rear-side UV exposure and edge seal integrity are critical failure modes

FAQ

What UV spectral distribution does the DV-540H replicate?
It uses UVA-340 fluorescent lamps conforming to ISO 4892-3 spectral power distribution (SPD) for wavelengths 280–400 nm, with peak intensity at 340 nm—matching terrestrial solar UV below 360 nm.
Is irradiance uniformity validated across the test plane?
Yes. Uniformity is ≥90% over a 600 mm × 600 mm area (per ASTM G154 Section 8.2), verified annually with a NIST-traceable UV radiometer.
Can the chamber perform condensation cycles without UV exposure?
Yes. The dark condensation mode activates steam injection and controlled cooling to simulate overnight dew formation at user-defined RH and temperature setpoints.
Does the system support third-party calibration certificates?
Jianhu provides factory calibration reports per ISO/IEC 17025; accredited third-party calibration (e.g., TÜV, SGS) is available upon request.
What maintenance intervals are recommended for lamp replacement and sensor verification?
UV lamps require replacement every 1,600 hours of operation; black panel sensors and RH probes are verified quarterly using traceable reference standards.