Empowering Scientific Discovery

ShengAohua 6B-24(V9) Dual-Zone COD Digestion Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand ShengAohua
Origin Jiangsu, China
Manufacturer Type Direct Manufacturer
Region of Manufacture Domestic (China)
Model 6B-24(V9)
Digestion Method Rapid Closed-Tube Digestion
Heating Modules Dual Independent Heated Blocks
Batch Capacity 24 samples (12 × 2 configuration)
Temperature Range Ambient to 200 °C
Temperature Accuracy ±1 °C
Digestion Vessel Volume 17 mL
Timer Accuracy ±0.1 s at 10 min
Temperature Control Precision 165 °C ±1 °C and 123 °C ±1 °C
Heating Ramp Time ≤10 min to setpoint
Timer Range 1–199 min
Power Supply AC 220 V / 50 Hz
Rated Power 460 W
Dimensions (W×D×H) 300 × 240 × 210 mm
Weight 5.8 kg

Overview

The ShengAohua 6B-24(V9) Dual-Zone COD Digestion Analyzer is an engineered solution for standardized, high-throughput chemical oxygen demand (COD) determination in accordance with ISO 6060, EPA Method 410.4, and HJ 828–2017 (Chinese Environmental Protection Standard). It implements rapid closed-tube digestion—a thermally accelerated oxidation process using potassium dichromate under strongly acidic conditions at elevated temperatures—to convert organic matter into CO2, enabling quantitative spectrophotometric or titrimetric endpoint analysis. Its dual-zone architecture allows simultaneous digestion of two sample groups at independently controlled temperatures—e.g., 165 °C for COD and 123 °C for total phosphorus—eliminating sequential runs and improving laboratory throughput without compromising thermal reproducibility. The instrument is designed for routine use in environmental testing laboratories, municipal wastewater treatment facilities, and industrial QC labs where regulatory compliance, operator safety, and inter-laboratory data comparability are critical.

Key Features

  • Dual independent heating blocks with separate PID temperature control loops—enabling concurrent digestion at two distinct setpoints (e.g., 165 °C ±1 °C and 123 °C ±1 °C) with <1 °C deviation across all 24 positions
  • High-stability timer system with ±0.1 s accuracy at 10 min; programmable range from 1 to 199 minutes in 1-minute increments
  • Preloaded digestion protocols for COD, total phosphorus, total nitrogen, copper, and hexavalent chromium—each validated per standard method requirements
  • Full keyboard-based parameter entry with digital display; temperature adjustable in 1 °C steps, time in 1 min steps
  • Thermal runaway protection: automatic power cutoff upon detection of sustained overtemperature (>2 °C above setpoint for >30 s)
  • Chemically resistant, injection-molded housing rated for continuous operation at ambient temperatures between –5 °C and 45 °C
  • Optically transparent, heat-resistant polycarbonate lid permitting real-time visual monitoring of digestion progress and reflux behavior without opening the chamber
  • Compact footprint (300 × 240 × 210 mm) and low mass (5.8 kg) for benchtop integration in space-constrained analytical environments

Sample Compatibility & Compliance

The 6B-24(V9) accommodates standard 17 mL borosilicate glass digestion tubes (e.g., ASTM D1252-compliant), supporting both open-reflux and sealed-vessel digestion configurations. Its dual-zone capability ensures method-specific thermal profiles required by multiple regulatory frameworks: COD digestion at 165 °C aligns with ISO 6060 Annex A and US EPA 410.4; lower-temperature programs meet HJ 671–2013 (total phosphorus) and HJ 636–2012 (total nitrogen). All thermal and timing parameters are traceable to NIST-calibrated references. The unit complies with IEC 61010-1:2010 for electrical safety in laboratory equipment and meets CE marking requirements for EMC (EN 61326-1) and low-voltage directive (2014/35/EU). While not inherently 21 CFR Part 11 compliant, its deterministic timer logic and non-volatile protocol storage support GLP-aligned documentation when paired with external audit-trail-enabled LIMS.

Software & Data Management

This is a standalone hardware analyzer with no embedded operating system or network interface. All operational parameters—including temperature setpoints, digestion duration, and protocol names—are entered via front-panel membrane keypad and displayed on a high-contrast blue-backlit LCD. Six user-accessible memory slots store custom protocols; modifications require manual re-entry and confirmation. No firmware updates, cloud connectivity, or remote diagnostics are supported. Data output is limited to visual verification and manual transcription. For laboratories requiring electronic record retention, integration with external barcode-scanned sample logging systems or spreadsheet-based SOP tracking is recommended. Protocol validation reports (including temperature uniformity mapping and timer calibration certificates) are provided upon request as part of installation qualification (IQ) documentation.

Applications

  • Routine COD analysis in municipal wastewater influent/effluent monitoring per ISO 6060 and national discharge standards
  • Multi-parameter batch digestion for environmental compliance reporting (e.g., simultaneous COD + TP in surface water surveys)
  • Industrial effluent screening in pulp & paper, textile dyeing, pharmaceutical manufacturing, and food & beverage processing
  • Educational use in university environmental chemistry labs—supporting student experiments on oxidation kinetics and method validation
  • Reference digestion unit in QA/QC workflows where thermal consistency across replicates is essential for uncertainty budgeting
  • Field-deployable lab support in mobile environmental testing units due to its low weight, passive cooling design, and 220 V single-phase power requirement

FAQ

Does the 6B-24(V9) support automated data export or USB connectivity?
No. It is a manually operated, non-networked instrument. All settings and run records must be documented externally.
Can digestion tubes from other manufacturers be used?
Yes—provided they conform to 17 mL nominal volume, OD ≤22 mm, and are rated for ≥200 °C continuous exposure (e.g., Pyrex or equivalent borosilicate glass).
Is calibration verification included with purchase?
A factory calibration certificate covering temperature uniformity (±1 °C across all positions) and timer accuracy (±0.1 s at 10 min) is supplied. Annual recalibration is recommended using NIST-traceable thermocouples and stopwatch standards.
What safety features prevent acid vapor exposure during digestion?
The sealed digestion tube design—combined with the transparent polycarbonate lid’s chemical resistance to H2SO4/H3PO4 mixtures—minimizes operator exposure. Ventilation hoods are still required per OSHA 1910.1200 when handling post-digestion samples.
How is thermal uniformity maintained across 24 positions?
Each heating block uses embedded Pt100 RTD sensors and adaptive PID algorithms with position-compensated gain scheduling, validated to maintain ≤±0.8 °C inter-position variance at 165 °C.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0