Titan CP-0620 Integrated Circulating Chiller
| Brand | Titan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | CP-0620 |
| Instrument Type | Integrated Unit |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5–32 °C |
| Refrigeration Capacity | 700 W |
| Temperature Stability | ±0.1 °C |
| Circulating Pump Pressure | 0.3 bar |
| Circulating Flow Rate | 22 L/min |
| Reservoir Volume | 4.5 L |
| Operation Mode | Continuous |
Overview
The Titan CP-0620 is an integrated, water-cooled circulating chiller engineered for precision temperature control in laboratory and analytical instrumentation applications. It operates on a closed-loop refrigeration cycle utilizing R-410A or equivalent environmentally compliant refrigerant, delivering stable thermal management to external equipment such as spectrophotometers, ICP-OES/MS systems, laser sources, rotary evaporators, and vacuum pumps. Designed for continuous-duty operation, the CP-0620 maintains setpoint temperatures within ±0.1 °C across its operational range of 5–32 °C—optimized for ambient environments where consistent heat dissipation is critical to instrument performance and measurement reproducibility. Its compact footprint and integrated reservoir-pump-refrigeration architecture eliminate the need for external cooling towers or auxiliary water supplies, making it suitable for benchtop deployment in QC labs, research facilities, and GMP-compliant manufacturing support environments.
Key Features
- Integrated design with built-in 4.5 L stainless-steel reservoir, centrifugal circulation pump, condenser, and hermetic compressor—no external plumbing or chill water infrastructure required.
- Water-cooled condenser enables stable operation in ambient temperatures up to 35 °C; compatible with facility-supplied cooling water at ≤30 °C inlet temperature and 1.5–3.0 bar supply pressure.
- Precision digital PID temperature controller with real-time display, programmable setpoint memory, and over-temperature/low-flow safety interlocks.
- Circulation system delivers up to 22 L/min at 0.3 bar head pressure—sufficient for multi-port distribution manifolds or series-connected instruments.
- Low-noise operation (<58 dB(A) at 1 m), vibration-damped mounting, and corrosion-resistant housing for long-term reliability in shared lab spaces.
- Front-panel RS-485 interface (Modbus RTU protocol) supports integration into centralized lab monitoring systems or SCADA platforms.
Sample Compatibility & Compliance
The CP-0620 is compatible with standard 1/4″–3/8″ OD tubing connections (compression or quick-connect fittings) and supports both deionized water and aqueous glycol solutions (up to 30% v/v) for sub-5 °C operation. All wetted components—including reservoir, pump head, and heat exchanger—are constructed from 304 stainless steel and EPDM elastomers, ensuring chemical compatibility with common laboratory coolants and resistance to microbial growth. The unit complies with IEC 61010-1:2010 for electrical safety in laboratory equipment and meets CE marking requirements under the EU Low Voltage and EMC Directives. Optional factory-installed PT100 sensor output (0–10 V or 4–20 mA) enables traceable temperature logging per ISO/IEC 17025 and FDA 21 CFR Part 11 guidelines when paired with validated data acquisition software.
Software & Data Management
While the CP-0620 operates autonomously via its embedded controller, optional communication modules enable remote supervision and audit-ready data capture. When connected to a host PC or PLC via RS-485, users can log temperature setpoints, actual bath temperature, pump status, compressor runtime, and alarm events at user-defined intervals (1–600 s). Exported CSV files include timestamped entries with millisecond resolution, supporting GLP documentation workflows. Firmware updates are performed via USB port using signed binaries, preserving configuration integrity during maintenance cycles. No cloud connectivity or proprietary cloud platform is embedded—ensuring full data sovereignty and alignment with institutional IT security policies.
Applications
- Thermal stabilization of high-power optical components in Raman spectrometers and confocal microscopes.
- Cooling jacket support for reflux condensers in automated synthesis reactors (e.g., ChemSpeed, Biotage).
- Heat load management for plasma torches in ICP-based elemental analyzers.
- Condenser cooling in rotary evaporation systems operating under reduced pressure.
- Temperature regulation of electrophoresis power supplies and gel imaging cabinets.
- Support of ASTM D97, D2500, and ISO 3016 cloud point measurements requiring precise bath stability.
FAQ
What is the maximum allowable ambient temperature for continuous operation?
The CP-0620 is rated for uninterrupted use at ambient temperatures up to 35 °C, provided facility cooling water inlet temperature remains ≤30 °C and flow rate exceeds 1.5 L/min.
Can the unit be used with ethylene glycol solutions?
Yes—up to 30% (v/v) aqueous ethylene glycol is supported; however, viscosity increase reduces effective flow rate by ~12% at 20% concentration, and minimum operating temperature is limited to 0 °C.
Is the reservoir accessible for cleaning and disinfection?
Yes—the top-mounted lid is removable, and the 4.5 L reservoir features smooth-welded corners and a drain valve for complete fluid evacuation and periodic sanitization with 70% ethanol or diluted hydrogen peroxide.
Does the chiller support external temperature feedback control?
Not natively; the standard configuration regulates based on internal bath sensor only. An optional external PT100 input module (Order Code: CP-0620-EXT-SEN) enables dual-sensor cascade control for process-critical applications.
What maintenance intervals are recommended?
Compressor oil and refrigerant charge require no scheduled service under normal operation; annual inspection of condenser fins, pump impeller clearance, and electrical terminations is advised per Titan’s Maintenance Protocol MP-CP0620 Rev. 3.