Empowering Scientific Discovery

Titan SCY-4 4-Gallon (15 L) Flammable Liquid Safety Cabinet

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Titan
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Country of Origin Domestic (China)
Model SCY-4
Price USD 350 (FOB Shanghai)

Overview

The Titan SCY-4 is a UL-listed and FM-approved flammable liquid safety cabinet engineered for secure, code-compliant storage of Class I flammable liquids—including acetone, ethanol, gasoline, toluene, and other solvents—in laboratory, pharmaceutical, chemical manufacturing, and industrial settings. Designed in accordance with NFPA 30 (Flammable and Combustible Liquids Code), OSHA 29 CFR 1910.106, and ANSI Z358.1 standards, this 4-gallon (15 L) cabinet provides passive fire protection through double-walled 18-gauge steel construction with a 1.5-inch air gap, self-closing three-point latching doors, and dual 2-inch flame-arresting vents equipped with internal flash arrestors. Its compact footprint makes it ideal for benchtop or under-counter deployment where space is constrained but regulatory compliance remains non-negotiable.

Key Features

  • Double-wall 18-gauge steel construction with 1.5-inch insulating air gap for 10-minute fire resistance rating
  • Self-closing, three-point stainless steel latch system with automatic door closure at 165°F (74°C) via fusible link
  • Dual 2-inch top-mounted vents with integral flame arrestors—configurable for ducted or recirculating operation per local ventilation codes
  • Leak-proof 2-inch deep galvanized steel spill containment sump (capacity: ≥2 gallons / 7.6 L)
  • High-visibility, photoluminescent warning labels compliant with ANSI Z535.4 and GHS pictograms
  • Leveling feet with adjustable height range (±10 mm) for stable placement on uneven surfaces
  • No internal electrical components—fully intrinsically safe design meeting Class I, Division 2, Group D hazardous location requirements

Sample Compatibility & Compliance

The SCY-4 cabinet is certified for storage of all Class I flammable liquids (flash point < 100°F / 37.8°C) and select Class II combustibles (flash point 100–140°F). It is not rated for pressurized containers, reactive chemicals (e.g., alkali metals, peroxides), or oxidizers. Regulatory documentation includes third-party test reports verifying conformance to UL 1275 (Standard for Safety of Flammable Liquid Storage Cabinets) and FM 6050 (Approval Standard for Safety Cabinets). The unit meets EU CE marking requirements under the ATEX Directive 2014/34/EU for equipment used in potentially explosive atmospheres when installed per manufacturer instructions. All units ship with a full compliance dossier including certificate of conformance, assembly instructions, and hazard communication guidelines aligned with OSHA HazCom 2012 and CLP Regulation (EC) No. 1272/2008.

Software & Data Management

As a passive mechanical safety device, the SCY-4 does not incorporate embedded electronics, firmware, or software interfaces. Its operational integrity relies solely on mechanical engineering and material performance—eliminating cybersecurity vulnerabilities, firmware obsolescence, or calibration drift. Maintenance records, inspection logs, and inventory tracking are supported through integration with enterprise EHS (Environment, Health & Safety) platforms such as Intelex, ETQ Reliance, or Sphera EHS. Optional QR-coded asset tags enable rapid access to digital safety data sheets (SDS), inspection checklists, and audit-ready documentation via mobile devices—fully compatible with ISO 45001:2018 clause 8.2 (Hazard identification and assessment) and FDA 21 CFR Part 11–aligned electronic record systems when deployed with validated EHS software.

Applications

  • Secure point-of-use storage for flammable reagents in analytical laboratories (e.g., GC solvent bottles, HPLC mobile phase reservoirs)
  • Controlled dispensing stations in QC/QA labs requiring immediate access without violating maximum allowable quantities per control area
  • Intermediate holding for in-process solvents in small-batch pharmaceutical synthesis or coating operations
  • Mobile storage solution on trolleys or carts in pilot plant environments with frequent layout reconfiguration
  • Supplemental containment in cleanrooms where HVAC constraints limit centralized solvent storage

FAQ

Does the SCY-4 require external grounding?
Yes. Per NFPA 30 Section 9.5.2 and OSHA 1910.106(e)(2)(ii), all flammable liquid cabinets must be bonded and grounded using a minimum 12 AWG copper wire connected to a verified earth ground before initial use and verified annually.
Can the cabinet be installed indoors without ducting the vents?
Yes—if local authority having jurisdiction (AHJ) permits recirculation and room ventilation exceeds 6 air changes per hour (ACH), as specified in ANSI Z9.2 and ASHRAE 110. Vent caps must remain installed to maintain flame arrestor functionality.
Is the sump capacity sufficient for secondary containment under EPA 40 CFR 264.175?
Yes. The 7.6 L sump exceeds the regulatory requirement of 10% of total stored volume or 100% of the largest container—whichever is greater—making it compliant for single-container use per federal U.S. EPA regulations.
What maintenance is required to retain certification?
Annual visual inspection of door seals, latch function, vent integrity, and sump corrosion status is mandatory. Fusible links must be replaced after any activation or every five years, per UL 1275 Section 15.3. No recalibration or software updates apply.