XY 10002C Precision Electronic Balance
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | XY 10002C |
| Price Range | USD 420–560 |
| Instrument Type | Precision Balance |
| Capacity | 100 g |
| Readability | 0.01 g |
| Pan Diameter | 130 mm |
| Power Supply | AC 220 V / DC 9 V |
| Display | Wide-View LCD |
| Units | g, oz, ct, lb |
| Interface | RS232 (optional) |
| Optional Accessories | Removable draft shield, rechargeable battery pack, stainless-steel weighing pan, powder-coated metal base |
Overview
The XY 10002C Precision Electronic Balance is an entry-level analytical-grade instrument engineered for consistent mass measurement in industrial quality control, laboratory preparation, and production line verification environments. Utilizing electromagnetic force compensation (EMFC) transduction technology, the balance delivers stable, drift-compensated readings with high reproducibility under variable ambient conditions. Its 100 g capacity and 0.01 g readability meet the performance requirements of ISO/IEC 17025-compliant calibration workflows for Class II and III applications, including raw material verification, batch sampling, and intermediate formulation checks. Designed for operational flexibility, the unit supports both AC mains and DC power inputs—enabling deployment in fixed lab stations or mobile field-use scenarios where stable AC infrastructure is unavailable. The compact footprint (≤200 mm × 200 mm base) and lightweight construction facilitate integration into constrained workspaces without compromising mechanical stability.
Key Features
- Electromagnetic force compensation (EMFC) sensor architecture ensuring long-term linearity and minimal hysteresis
- Removable draft shield assembly—designed for rapid cleaning and interference-free operation during non-critical weighing tasks
- Wide-view, high-contrast LCD display with adjustable contrast control for optimal legibility under varied lighting conditions
- Four-unit conversion system (g, oz, ct, lb) with automatic zero-tracking and auto-tare functionality
- Stainless-steel weighing pan (Ø130 mm) paired with a corrosion-resistant, powder-coated metal base for durability in humid or chemically exposed settings
- RS232 serial interface (optional) supporting bidirectional data transfer to LIMS or ERP systems with configurable baud rates (9600–19200 bps)
- DC 9 V input compatibility enabling use with external rechargeable battery packs (optional accessory), extending operational uptime during power outages or portable deployments
Sample Compatibility & Compliance
The XY 10002C accommodates solid, granular, and low-viscosity powdered samples within its 100 g maximum load range. Its open-top design—combined with the optional removable draft shield—allows straightforward handling of vials, beakers, and standard weighing boats. While not certified for GLP/GMP-regulated final release testing, the balance conforms to general-purpose metrological standards outlined in OIML R76-1 (2017) for non-automatic weighing instruments and satisfies basic traceability requirements when calibrated using NIST-traceable Class F1 or Class M2 weights. It is suitable for routine QC checks aligned with ASTM E1223 (Standard Guide for Use of Weighing Devices in Laboratory Applications) and supports documentation-ready workflows when used with external calibration logs and user-defined SOPs.
Software & Data Management
Data output via the optional RS232 interface complies with standard ASCII protocol formatting, permitting direct import into Excel, LabWare LIMS, or custom Python/Matlab scripts for statistical process monitoring. The balance does not include embedded software or touchscreen UI; instead, it relies on hardware-level firmware that enforces deterministic response timing (<1.5 s stabilization time after loading) and maintains audit trail integrity through sequential timestamping of all tare and unit-change events. When integrated into regulated environments, users may implement external validation protocols per FDA 21 CFR Part 11 Annex 11 guidelines—leveraging third-party data capture tools to enforce electronic signatures, role-based access, and immutable record retention.
Applications
- Industrial配料 (batch ingredient dispensing) in food, pharmaceutical, and chemical manufacturing lines
- Raw material receipt inspection and in-process weight verification prior to mixing or encapsulation
- Calibration of volumetric glassware using density-based mass-to-volume correlation methods
- Counting operations for uniform small parts (e.g., screws, tablets, connectors) using built-in piece-count mode
- Teaching laboratories requiring robust, serviceable instrumentation for introductory metrology and uncertainty analysis exercises
- Field-deployed environmental sampling support—where portability, battery operation, and resistance to dust/moisture are critical
FAQ
What is the recommended calibration frequency for the XY 10002C in routine industrial use?
Calibration should be performed at startup, following any significant environmental change (≥5 °C temperature shift or relocation), and at least once per shift when used in continuous production environments. Internal calibration is not supported; external calibration using traceable weights is mandatory.
Does the balance support internal calibration or motorized adjustment?
No. The XY 10002C requires external calibration with certified reference masses. It lacks internal calibration mechanisms or automatic adjustment routines.
Can the RS232 interface transmit real-time weight data to a PLC or SCADA system?
Yes—when configured with appropriate handshaking signals (RTS/CTS), the interface outputs stabilized weight values as ASCII strings at user-defined intervals, compatible with most industrial control platforms.
Is the stainless-steel pan removable for cleaning or replacement?
Yes. The pan is mechanically secured with standardized fasteners and can be detached without tools for ultrasonic cleaning or replacement under standard maintenance procedures.