YSI EC300 Conductivity, Salinity & Temperature Meter
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YSI EC300 |
| Price | Upon Request |
| Temperature Range | −10 °C to +90 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C or ±0.4% of full scale, whichever is greater |
| Conductivity Ranges | 0–499.9 μS/cm (0.1 μS/cm res.), 500–4999 μS/cm (1 μS/cm res.), 5.00–49.99 mS/cm (0.01 mS/cm res.), 50.0–200.0 mS/cm (0.1 mS/cm res.) |
| Cond. Accuracy | ±1% reading + 2 μS/cm / ±1% + 5 μS/cm / ±1% + 0.05 mS/cm / ±2.5% + 0.5 mS/cm (by range) |
| Salinity Range | 0.0–70.0 ppt |
| Salinity Resolution | 0.1 ppt |
| Salinity Accuracy | ±0.2% of full scale |
| TDS Calculation | User-configurable conversion factor (0.30–1.00), default 0.65 |
| Operating Temp. | 0–50 °C |
| RH Limit | ≤95% non-condensing |
| Reference Temp. | 15.0–25.0 °C (default 25 °C) |
| Temp. Coefficient | 0.0–4.0% (default 1.91%) |
| Cell Constant | 4.50–5.50 cm⁻¹ (default 5.00 cm⁻¹) |
| Calibration Storage | Automatic |
| Audio Feedback | Keypress tones enabled |
| IP Rating | IP65 (main unit) |
| Power | 1 × 9 V alkaline battery (≈150 h typical life) |
| Dimensions | 18.6 × 7.0 × 3.7 cm |
| Weight | 430 g (with battery) |
| Warranty | 1 year (instrument, probe, cable) |
Overview
The YSI EC300 Conductivity, Salinity & Temperature Meter is a field-deployable, four-electrode conductivity sensor system engineered for high-reproducibility measurements in freshwater, estuarine, and coastal marine environments. It operates on the principle of conductometric measurement—applying an alternating current across four stainless-steel electrodes to eliminate polarization effects and electrode fouling, thereby ensuring stable baseline performance over extended deployments. Unlike two-electrode systems, the EC300’s quad-electrode design inherently compensates for lead resistance and contact impedance, delivering reliable conductivity data across a wide dynamic range (0.001–200 mS/cm). The instrument computes derived parameters—including specific conductivity (temperature-compensated to user-selectable reference temperatures), practical salinity (PSS-78 compliant algorithm), and total dissolved solids (TDS)—using programmable conversion factors traceable to standard methods such as ASTM D1125 and ISO 7888. Its compact form factor, ruggedized housing, and IP65-rated enclosure make it suitable for routine grab sampling, stream monitoring, aquaculture management, and regulatory field surveys where portability and operational simplicity are critical.
Key Features
- Four-electrode conductivity cell with stainless-steel sensing elements—minimizes polarization drift and eliminates need for frequent recalibration
- Automatic range switching and real-time temperature compensation using user-adjustable coefficients (0.0–4.0%/°C, default 1.91% at 25 °C)
- Programmable cell constant (4.50–5.50 cm⁻¹) and TDS conversion factor (0.30–1.00, default 0.65 per Standard Methods 2540C)
- Integrated temperature sensor (NTC thermistor) with ±0.2 °C accuracy across −10 °C to +90 °C operating range
- Acoustic keypad feedback and low-battery indicator for unambiguous field operation
- Stress-relieved cable interface to reduce mechanical fatigue at connector junctions—extends service life of 4 m and 10 m probe cables
- Onboard calibration memory stores up to three-point conductivity calibrations (e.g., 1, 10, and 50 mS/cm standards)
Sample Compatibility & Compliance
The EC300 is validated for use with natural waters—including rivers, lakes, wetlands, irrigation canals, wastewater effluents, and brackish estuaries—where suspended solids, biofilm accumulation, or variable ionic strength may challenge conventional sensors. Its robust electrode geometry resists clogging and enables rapid response in turbulent or sediment-laden conditions. While not certified for GLP or GMP-regulated production environments, the instrument supports documentation integrity through automatic timestamped calibration logging and adherence to foundational water quality standards: ASTM D1125 (electrical conductivity of water), ISO 7888 (conductivity of water for pharmaceutical use), and APHA Standard Methods 2510B (conductivity) and 2520B (salinity). Its temperature compensation logic follows the nonlinear CaCl₂-based algorithm recommended by USGS for environmental applications, ensuring consistency with long-term monitoring datasets.
Software & Data Management
The EC300 operates as a standalone field meter with no external software dependency. All calibration events—including date/time stamp, standard value used, and cell constant applied—are retained in non-volatile memory and accessible via the display menu. While the device lacks Bluetooth or USB connectivity, its deterministic output format (ASCII-readable values with unit suffixes) allows seamless transcription into LIMS or spreadsheet-based QA/QC workflows. For laboratories requiring audit-ready records, manual entry into electronic notebooks compliant with FDA 21 CFR Part 11 can be supported by pairing the EC300 with a validated data capture protocol—e.g., dual-operator verification of displayed readings prior to logging. Factory-supplied calibration standards (e.g., YSI 3167-1, 3168-1, 3169-1) are NIST-traceable and certified to ±1% conductivity uncertainty.
Applications
- Regulatory compliance monitoring under EPA Clean Water Act Section 303(d) listing protocols
- Baseline characterization and trend analysis in watershed assessment programs
- Real-time salinity tracking during stormwater discharge events in coastal municipalities
- Process control in recirculating aquaculture systems (RAS) and hydroponic nutrient delivery loops
- Educational field labs requiring student-safe, single-handed operation and intuitive interface
- Pre-screening tool for laboratory-based ICP-MS or ion chromatography sample prioritization
FAQ
Does the EC300 support automatic temperature compensation for all conductivity ranges?
Yes—the instrument applies dynamic, range-specific temperature compensation algorithms across all four conductivity spans, referencing either user-defined or default (25 °C) reference temperatures.
Can the TDS conversion factor be adjusted for non-standard water matrices?
Yes—users may input any factor between 0.30 and 1.00 to align TDS calculations with site-specific ionic composition or regulatory reporting requirements.
Is the probe compatible with YSI’s older 300-series accessories?
Yes—the EC300 accepts legacy 300-4 and 300-10 probe assemblies, including their integrated temperature sensors and cable configurations.
What maintenance is required for long-term field deployment?
Routine cleaning with deionized water and soft brush is sufficient; the four-electrode design eliminates need for polishing or platinization. Annual verification against certified standards is recommended for QA/QC programs.
How does the EC300 handle high-conductivity seawater samples?
At 50–200 mS/cm, accuracy is specified as ±2.5% of reading plus 0.5 mS/cm offset—consistent with industry expectations for handheld meters in saline environments where electrode polarization dominates error sources.