Empowering Scientific Discovery

Beijing Jinfuhong Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelIR 400KA
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelCMPK 70
Vibration Pen CMVP 50Velocity RMS 0.1–55 mm/s (10 Hz–1 kHz), Acceleration Envelope gE 0.01–45 gE (10 kHz–30 kHz)
Oil Condition Checker TMEH 1Compatible with mineral & synthetic oils, repeatability <5%, visual green/red indicator + numeric scale (0–100), 9V alkaline battery (IEC 6LR61), 150 h runtime or ~3,000 tests, dimensions 250 × 95 × 32 mm
Infrared Thermometer CMSS 2000Temperature range −32 °C to +500 °C, accuracy: ±3 °C (−32 to −26 °C), ±2.5 °C (−26 to −18 °C), ±2 °C (−18 to +25 °C), ±1% or ±1 °C (>+25 °C)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelYSI pH10
PriceUpon Request
Measurement Range (pH)0.00–14.00
Measurement Range (Temperature)0.0–99.9 °C
pH Resolution0.01
Temperature Resolution0.1 °C
pH Accuracy±0.02 ±1 digit
Temperature Accuracy±0.3 °C
Operating Environment0.0–50.0 °C
IP RatingIP67
Temperature CompensationAutomatic, 0.0–99.9 °C
Buffer RecognitionUSA (4.01, 7.00, 10.01) and NIST (4.01, 6.86, 9.18) standards
Calibration Temperature Range0.0–60.0 °C
Memory CapacityNon-volatile storage for 50 data sets (pH, temperature, date, time)
Power Supply4 × LR44 alkaline button cells
Battery LifeApprox. 35 hours
Dimensions4.5 cm (width) × 19 cm (length) × 2 cm (thickness)
Weight105 g
Warranty1 year (instrument), 6 months (electrode)
Electrode ReplacementTool-free, user-serviceable
GLP ComplianceCalibration history logging with timestamp
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelGT-100
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelVM-1B
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
Measurement Range (IR)–60 °C to +500 °C
Measurement Range (Contact)–60 °C to +1400 °C
Sensor TypeK-type thermocouple (TMDT 2–30, up to 900 °C)
Accuracy±2% of reading or ±2 °C (whichever is greater)
Response Time500–1000 ms
DS Ratio: 11:1
Spectral Range8–14 µm
Emissivity Adjustment0.1–1.0 (adjustable)
Display Resolution0.1 °C
Laser ClassII (635–650 nm, ≤1 mW)
Operating Temp.0 °C to 50 °C
Storage Temp.–20 °C to +65 °C
Power2 × AAA (IEC LR03), 140 h (laser/backlight off)
Dimensions175 × 72 × 39 mm
Weight940 g
EMC ComplianceEN 61326-1:1997 + A1 + A2
Laser SafetyCFR 1040.10 / IEC 60825-1
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model420C-01
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelVM-63A
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMitsubishi Chemical
OriginJapan
ModelCA-200
Detection PrincipleCoulometric Karl Fischer Titration
Electrolysis Current430 mA
Titration Rate2.2 mg H₂O/min (36 µg H₂O/sec)
Measurement Range10 µg – 100 mg H₂O
Sensitivity0.1 µg H₂O
Precision±3 µg (for 10 µg–1 mg H₂O)
Cell Volume150 mL
Display5.7-inch color LCD
Data Storage~100 measurements
StirringMagnetic stirring
ConnectivityRS-232 (optional), USB (data export & peripheral interface), optional electronic balance interface
ComplianceGLP/GMP-supporting audit trail, auto-electrode cleaning, calendar/time stamping, self-diagnostic mode
PowerAC 220–240 V, 50/60 Hz, 310 VA
Dimensions (main unit)330 × 320 × 148 mm
Weight (main unit)~5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model410D-01
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelVM-2002
PricingUpon Request
Displacement (peak-to-peak)2–1999 µm
Velocity (RMS)0.2–199.9 mm/s
Acceleration (RMS)0.02–19.99 m/s²
Frequency Response10 Hz – 1 kHz
Power Supply9 V industrial rectangular battery
Data Storage CapacityMulti-year historical vibration records across hundreds of measurement points
InterfaceIntegrated PDA with USB/RS-232 connectivity for PC synchronization
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelYSI EC300
PriceUpon Request
Temperature Range−10 °C to +90 °C
Temp. Resolution0.1 °C
Temp. Accuracy±0.2 °C or ±0.4% of full scale, whichever is greater
Conductivity Ranges0–499.9 μS/cm (0.1 μS/cm res.), 500–4999 μS/cm (1 μS/cm res.), 5.00–49.99 mS/cm (0.01 mS/cm res.), 50.0–200.0 mS/cm (0.1 mS/cm res.)
Cond. Accuracy±1% reading + 2 μS/cm / ±1% + 5 μS/cm / ±1% + 0.05 mS/cm / ±2.5% + 0.5 mS/cm (by range)
Salinity Range0.0–70.0 ppt
Salinity Resolution0.1 ppt
Salinity Accuracy±0.2% of full scale
TDS CalculationUser-configurable conversion factor (0.30–1.00), default 0.65
Operating Temp.0–50 °C
RH Limit≤95% non-condensing
Reference Temp.15.0–25.0 °C (default 25 °C)
Temp. Coefficient0.0–4.0% (default 1.91%)
Cell Constant4.50–5.50 cm⁻¹ (default 5.00 cm⁻¹)
Calibration StorageAutomatic
Audio FeedbackKeypress tones enabled
IP RatingIP65 (main unit)
Power1 × 9 V alkaline battery (≈150 h typical life)
Dimensions18.6 × 7.0 × 3.7 cm
Weight430 g (with battery)
Warranty1 year (instrument, probe, cable)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelZTB2005E
PricingAvailable Upon Request
Vibration Accuracy±5%
Vibration Resolution1 µm
Vibration Frequency Range10 Hz – 1 kHz
Vibration Measurement Range1 µm – 700 µm
Temperature Accuracy±1% FS or ±1 °C (whichever is greater)
Temperature Resolution1 °C
Temperature Distance-to-Spot Ratio7:1
Temperature Range−20 °C to +180 °C
Acoustic Frequency Range20 Hz – 20 kHz
Sound Level Display Range20 dB – 60 dB
Acoustic Resolution1 dB
Acoustic Accuracy±10%
Display128 × 128 pixel monochrome LCD with Chinese character support
Operating Temperature−20 °C to +60 °C
Storage Temperature−30 °C to +70 °C
Data LoggingIntegrated metering and timestamped record storage
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelYSI 3200
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXutongyongfu
ModelXT-107A
OriginBeijing, China
Power SupplyAC 220 V ±10%, 50 Hz ±1 Hz
Operating Temperature−5 °C to +40 °C
Relative Humidity≤90% at +25 °C
Output Voltage RatingDC 4.5 kV / AC 3 kV
Accuracy±1.5%
Rated Capacity2 kVA
Dimensions400 × 300 × 300 mm
Display4½-digit digital meters + embedded oscilloscope module
Safety FeaturesZero-position interlock, overcurrent protection, timed audible/visual alarm
Input–Output IsolationGalvanically isolated
Output ConfigurationRear-panel high-voltage AC/DC terminals
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelSverker 750/760
AC Current Output0–10 A (75 V full-load), 0–40 A (20 V), 0–100 A (8 V), 0–250 A (10 V, 1 s pulse)
AC Voltage Output0–250 V (3 A, 250 V full-load), 0–300 V AC (2 A)
Auxiliary AC/DC Voltage Outputs0–60 V AC / 60–120 V AC / 20–130 V DC / 130–220 V DC (all up to 0.4 A)
Timer Range0.000–999.9 s (±1 ms accuracy)
Current MeasurementInternal 0.00–200.0 A (±0.5%), External 0.000–6.000 A (±0.5%)
Voltage Measurement0.00–600.0 V (±0.5% for AC/DC)
Phase Angle Adjustment0–359° (±1° resolution)
Dimensions350 × 270 × 220 mm
Weight18 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelYSI 5000 Series
Measurement Range0–60 mg/L DO / 0–600% air saturation
Temperature Range–5 to +50 °C
Resolution0.01 mg/L / 0.1% air saturation / 0.1 °C
Accuracy±0.1% of reading + 1 LSD (DO and % saturation) / ±0.1 °C (temperature)
Salinity Compensationup to 40 ppt
Data Storage100 timestamped readings with real-time clock
InterfaceRS-232
Power4 × D-cell alkaline batteries or 220 V AC adapter
Probe PowerInstrument-supplied (no external power required for YSI 5010/5015 probes)
Software CompatibilityYSI BOD Analysis Software (v5.1+), EPA Method 503-compliant OUR/SOUR calculation module (YSI 5100 only)
Built-in BarometerYes (YSI 5100 only)
Auto-CalibrationYes (YSI 5100 only)
Barcode Scanner SupportYes (YSI 5100 only)
Added to wishlistRemoved from wishlist 0
Add to compare
Output4–20 mA (proportional to selected velocity range)
Accuracy±5% of full-scale output
Frequency Response2 Hz – 2 kHz (−3 dB)
Flatness±10% from 10 Hz – 1 kHz
Buffered Output100 mV/g (acceleration sensitivity)
Power Supply22–36 VDC via dual-conductor cable
Operating Temperature−20 °C to +80 °C
Mounting1/4-28 UNC or M8 threaded stud
Weight (transmitter only)227 g
ComplianceDesigned for industrial condition monitoring per IEC 61266-1 and ISO 10816-3 guidelines
Optional AccessoriesCMSS 420LCD (local LCD display), CMSS 420LED (local LED display), CMSS 420BNC (buffered BNC output module)
Added to wishlistRemoved from wishlist 0
Add to compare
pH Range–2.000 to 19.999
pH Resolution0.1 / 0.01 / 0.001
pH Accuracy±0.001
Calibration Points1–5 (US/NIST, DIN, Custom)
mV Range±1999.9
mV Resolution0.1
mV Accuracy±0.1 mV or ±0.05% (whichever is greater)
Temperature Range–5 to 105 °C
Temp Resolution0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C)
Temp Accuracy±0.1 °C
Temp CompensationAuto/Manual
DisplayBacklit LCD
Electrode InterfacespH–BNC, Temp–miniDIN, Stirrer–phone jack (benchtop only)
CommunicationBidirectional RS232, optional USB cable
Data Storage200 GLP-compliant entries
Calibration HistoryLast 10 calibrations
Method Storage10 password-protected methods
Self-TestYes
Firmware UpgradeNetwork-enabled
Power4×AA batteries + optional universal AC adapter (benchtop)
CertificationsCE, CSA, UL, TÜV, FCC Class A
Operating Environment5–45 °C, 5–85% RH
IP RatingPortable—IP67
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelTMES 1/2
PricingUpon Request
Fiber Optic CoreAcrylic
Pixel CountTMES 1: 3,500
TMES 27,400
Fiber DiameterTMES 1: 35 mm
TMES 213 mm
Max Fiber Damage ToleranceTMES 1: ≤2%
TMES 2≤0.5%
Cable MaterialSUS304 stainless steel braid with PVC jacket
Minimum Bend Radius40 mm
Cable LengthTMES 1: 1 m
TMES 23 m
Cable DiameterTMES 1: 8 mm
TMES 25 mm
Light Source3.5 V, 0.7 A, 2.55 W LED-equivalent incandescent
Power Supply3 × C (LR14) alkaline batteries
Viewing DirectionStraight-ahead
Field of ViewTMES 1: 60°
TMES 255°
Fixed Focus Distance10 mm
Waterproof RatingObjective lens and fiber cable rated for 1–1.3 bar air pressure (IP65 equivalent for probe section)
Operating Temperature−20 °C to +60 °C
Total Weight1,135 g
Packaging Dimensions360 × 270 × 80 mm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelYSI 5000
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelVM-2000
PriceUpon Request
Vibration Amplitude Range (Peak-to-Peak)2–1999 µm (±2 µm accuracy, 1 µm resolution)
Frequency Range10 Hz – 1 kHz
Measurement Update Rate1 reading/sec
Display4-digit LCD
Operating Temperature−10 °C to +40 °C
Power Supply9 V alkaline battery (included)
Auto-Hold FunctionYes
Auto-Power-Off20 seconds of inactivity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNittoseiko Analytech
OriginJapan
ModelCA-200
Detection PrincipleCoulometric Karl Fischer Titration
Electrolysis Current430 mA
Titration Speed2.2 mg H₂O/min (36 µg H₂O/sec)
Measurement Range10 µg – 100 mg H₂O
Sensitivity0.1 µg H₂O
Precision±3 µg (for 10 µg–1 mg H₂O)
Cell Capacity150 mL
Display5.7-inch color LCD
Data Storage~100 recent measurements
File Capacity20 standard files + 50 composite files
StirringMagnetic stirring
Power SupplyAC 220/240 V, 50/60 Hz, 310 VA
Operating Environment5–40 °C, ≤85% RH (non-condensing)
Dimensions (Analyzer)330 × 320 × 148 mm
Weight (Analyzer)~5 kg
ComplianceGLP-supporting architecture, audit-ready data handling, 21 CFR Part 11-compatible optional software modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXutongyongfu
ModelXT200
Output Voltage (AC)10 kV (6 kV motor class), 15 kV (10 kV motor class)
Output Voltage (DC)15 kV (6 kV motor class), 25 kV (10 kV motor class)
Max Output Current550 mA (with compensating reactor)
Rated Transformer Capacity1.0–1.5 kVA
Input PowerAC 220 V ±10%, 50 Hz ±1 Hz
DisplayAnalog pointer meter
Voltage Accuracy±1.5%
Timing Range0–999 s (±0.5% accuracy)
Overcurrent Protection6.7 A
Zero-Position InterlockYes
Auto Trip on Timeout/OvercurrentYes
Dimensions (W×D×H)400 × 300 × 300 mm
Weight22 kg
Operating Temperature–15 °C to +50 °C
Relative Humidity≤90% at +25 °C
ComplianceGB 50150–2006, DL/T 596–2005, DL/T 848.2–2004
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0