- All
- Favorite
- Popular
- Most rated
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IR 400KA |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CMPK 70 |
| Vibration Pen CMVP 50 | Velocity RMS 0.1–55 mm/s (10 Hz–1 kHz), Acceleration Envelope gE 0.01–45 gE (10 kHz–30 kHz) |
| Oil Condition Checker TMEH 1 | Compatible with mineral & synthetic oils, repeatability <5%, visual green/red indicator + numeric scale (0–100), 9V alkaline battery (IEC 6LR61), 150 h runtime or ~3,000 tests, dimensions 250 × 95 × 32 mm |
| Infrared Thermometer CMSS 2000 | Temperature range −32 °C to +500 °C, accuracy: ±3 °C (−32 to −26 °C), ±2.5 °C (−26 to −18 °C), ±2 °C (−18 to +25 °C), ±1% or ±1 °C (>+25 °C) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YSI pH10 |
| Price | Upon Request |
| Measurement Range (pH) | 0.00–14.00 |
| Measurement Range (Temperature) | 0.0–99.9 °C |
| pH Resolution | 0.01 |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.02 ±1 digit |
| Temperature Accuracy | ±0.3 °C |
| Operating Environment | 0.0–50.0 °C |
| IP Rating | IP67 |
| Temperature Compensation | Automatic, 0.0–99.9 °C |
| Buffer Recognition | USA (4.01, 7.00, 10.01) and NIST (4.01, 6.86, 9.18) standards |
| Calibration Temperature Range | 0.0–60.0 °C |
| Memory Capacity | Non-volatile storage for 50 data sets (pH, temperature, date, time) |
| Power Supply | 4 × LR44 alkaline button cells |
| Battery Life | Approx. 35 hours |
| Dimensions | 4.5 cm (width) × 19 cm (length) × 2 cm (thickness) |
| Weight | 105 g |
| Warranty | 1 year (instrument), 6 months (electrode) |
| Electrode Replacement | Tool-free, user-serviceable |
| GLP Compliance | Calibration history logging with timestamp |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GT-100 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | VM-1B |
| Pricing | Upon Request |
| Measurement Range (IR) | –60 °C to +500 °C |
|---|---|
| Measurement Range (Contact) | –60 °C to +1400 °C |
| Sensor Type | K-type thermocouple (TMDT 2–30, up to 900 °C) |
| Accuracy | ±2% of reading or ±2 °C (whichever is greater) |
| Response Time | 500–1000 ms |
| D | S Ratio: 11:1 |
| Spectral Range | 8–14 µm |
| Emissivity Adjustment | 0.1–1.0 (adjustable) |
| Display Resolution | 0.1 °C |
| Laser Class | II (635–650 nm, ≤1 mW) |
| Operating Temp. | 0 °C to 50 °C |
| Storage Temp. | –20 °C to +65 °C |
| Power | 2 × AAA (IEC LR03), 140 h (laser/backlight off) |
| Dimensions | 175 × 72 × 39 mm |
| Weight | 940 g |
| EMC Compliance | EN 61326-1:1997 + A1 + A2 |
| Laser Safety | CFR 1040.10 / IEC 60825-1 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 420C-01 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VM-63A |
| Pricing | Available Upon Request |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Detection Principle | Coulometric Karl Fischer Titration |
| Electrolysis Current | 430 mA |
| Titration Rate | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Measurement Range | 10 µg – 100 mg H₂O |
| Sensitivity | 0.1 µg H₂O |
| Precision | ±3 µg (for 10 µg–1 mg H₂O) |
| Cell Volume | 150 mL |
| Display | 5.7-inch color LCD |
| Data Storage | ~100 measurements |
| Stirring | Magnetic stirring |
| Connectivity | RS-232 (optional), USB (data export & peripheral interface), optional electronic balance interface |
| Compliance | GLP/GMP-supporting audit trail, auto-electrode cleaning, calendar/time stamping, self-diagnostic mode |
| Power | AC 220–240 V, 50/60 Hz, 310 VA |
| Dimensions (main unit) | 330 × 320 × 148 mm |
| Weight (main unit) | ~5 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410D-01 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | VM-2002 |
| Pricing | Upon Request |
| Displacement (peak-to-peak) | 2–1999 µm |
| Velocity (RMS) | 0.2–199.9 mm/s |
| Acceleration (RMS) | 0.02–19.99 m/s² |
| Frequency Response | 10 Hz – 1 kHz |
| Power Supply | 9 V industrial rectangular battery |
| Data Storage Capacity | Multi-year historical vibration records across hundreds of measurement points |
| Interface | Integrated PDA with USB/RS-232 connectivity for PC synchronization |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YSI EC300 |
| Price | Upon Request |
| Temperature Range | −10 °C to +90 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C or ±0.4% of full scale, whichever is greater |
| Conductivity Ranges | 0–499.9 μS/cm (0.1 μS/cm res.), 500–4999 μS/cm (1 μS/cm res.), 5.00–49.99 mS/cm (0.01 mS/cm res.), 50.0–200.0 mS/cm (0.1 mS/cm res.) |
| Cond. Accuracy | ±1% reading + 2 μS/cm / ±1% + 5 μS/cm / ±1% + 0.05 mS/cm / ±2.5% + 0.5 mS/cm (by range) |
| Salinity Range | 0.0–70.0 ppt |
| Salinity Resolution | 0.1 ppt |
| Salinity Accuracy | ±0.2% of full scale |
| TDS Calculation | User-configurable conversion factor (0.30–1.00), default 0.65 |
| Operating Temp. | 0–50 °C |
| RH Limit | ≤95% non-condensing |
| Reference Temp. | 15.0–25.0 °C (default 25 °C) |
| Temp. Coefficient | 0.0–4.0% (default 1.91%) |
| Cell Constant | 4.50–5.50 cm⁻¹ (default 5.00 cm⁻¹) |
| Calibration Storage | Automatic |
| Audio Feedback | Keypress tones enabled |
| IP Rating | IP65 (main unit) |
| Power | 1 × 9 V alkaline battery (≈150 h typical life) |
| Dimensions | 18.6 × 7.0 × 3.7 cm |
| Weight | 430 g (with battery) |
| Warranty | 1 year (instrument, probe, cable) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZTB2005E |
| Pricing | Available Upon Request |
| Vibration Accuracy | ±5% |
| Vibration Resolution | 1 µm |
| Vibration Frequency Range | 10 Hz – 1 kHz |
| Vibration Measurement Range | 1 µm – 700 µm |
| Temperature Accuracy | ±1% FS or ±1 °C (whichever is greater) |
| Temperature Resolution | 1 °C |
| Temperature Distance-to-Spot Ratio | 7:1 |
| Temperature Range | −20 °C to +180 °C |
| Acoustic Frequency Range | 20 Hz – 20 kHz |
| Sound Level Display Range | 20 dB – 60 dB |
| Acoustic Resolution | 1 dB |
| Acoustic Accuracy | ±10% |
| Display | 128 × 128 pixel monochrome LCD with Chinese character support |
| Operating Temperature | −20 °C to +60 °C |
| Storage Temperature | −30 °C to +70 °C |
| Data Logging | Integrated metering and timestamped record storage |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YSI 3200 |
| Pricing | Upon Request |
| Brand | Xutongyongfu |
|---|---|
| Model | XT-107A |
| Origin | Beijing, China |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Operating Temperature | −5 °C to +40 °C |
| Relative Humidity | ≤90% at +25 °C |
| Output Voltage Rating | DC 4.5 kV / AC 3 kV |
| Accuracy | ±1.5% |
| Rated Capacity | 2 kVA |
| Dimensions | 400 × 300 × 300 mm |
| Display | 4½-digit digital meters + embedded oscilloscope module |
| Safety Features | Zero-position interlock, overcurrent protection, timed audible/visual alarm |
| Input–Output Isolation | Galvanically isolated |
| Output Configuration | Rear-panel high-voltage AC/DC terminals |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Sverker 750/760 |
| AC Current Output | 0–10 A (75 V full-load), 0–40 A (20 V), 0–100 A (8 V), 0–250 A (10 V, 1 s pulse) |
| AC Voltage Output | 0–250 V (3 A, 250 V full-load), 0–300 V AC (2 A) |
| Auxiliary AC/DC Voltage Outputs | 0–60 V AC / 60–120 V AC / 20–130 V DC / 130–220 V DC (all up to 0.4 A) |
| Timer Range | 0.000–999.9 s (±1 ms accuracy) |
| Current Measurement | Internal 0.00–200.0 A (±0.5%), External 0.000–6.000 A (±0.5%) |
| Voltage Measurement | 0.00–600.0 V (±0.5% for AC/DC) |
| Phase Angle Adjustment | 0–359° (±1° resolution) |
| Dimensions | 350 × 270 × 220 mm |
| Weight | 18 kg |
| Brand | YSI |
|---|---|
| Origin | USA |
| Model | YSI 5000 Series |
| Measurement Range | 0–60 mg/L DO / 0–600% air saturation |
| Temperature Range | –5 to +50 °C |
| Resolution | 0.01 mg/L / 0.1% air saturation / 0.1 °C |
| Accuracy | ±0.1% of reading + 1 LSD (DO and % saturation) / ±0.1 °C (temperature) |
| Salinity Compensation | up to 40 ppt |
| Data Storage | 100 timestamped readings with real-time clock |
| Interface | RS-232 |
| Power | 4 × D-cell alkaline batteries or 220 V AC adapter |
| Probe Power | Instrument-supplied (no external power required for YSI 5010/5015 probes) |
| Software Compatibility | YSI BOD Analysis Software (v5.1+), EPA Method 503-compliant OUR/SOUR calculation module (YSI 5100 only) |
| Built-in Barometer | Yes (YSI 5100 only) |
| Auto-Calibration | Yes (YSI 5100 only) |
| Barcode Scanner Support | Yes (YSI 5100 only) |
| Output | 4–20 mA (proportional to selected velocity range) |
|---|---|
| Accuracy | ±5% of full-scale output |
| Frequency Response | 2 Hz – 2 kHz (−3 dB) |
| Flatness | ±10% from 10 Hz – 1 kHz |
| Buffered Output | 100 mV/g (acceleration sensitivity) |
| Power Supply | 22–36 VDC via dual-conductor cable |
| Operating Temperature | −20 °C to +80 °C |
| Mounting | 1/4-28 UNC or M8 threaded stud |
| Weight (transmitter only) | 227 g |
| Compliance | Designed for industrial condition monitoring per IEC 61266-1 and ISO 10816-3 guidelines |
| Optional Accessories | CMSS 420LCD (local LCD display), CMSS 420LED (local LED display), CMSS 420BNC (buffered BNC output module) |
| pH Range | –2.000 to 19.999 |
|---|---|
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| Calibration Points | 1–5 (US/NIST, DIN, Custom) |
| mV Range | ±1999.9 |
| mV Resolution | 0.1 |
| mV Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Temp Resolution | 0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp Accuracy | ±0.1 °C |
| Temp Compensation | Auto/Manual |
| Display | Backlit LCD |
| Electrode Interfaces | pH–BNC, Temp–miniDIN, Stirrer–phone jack (benchtop only) |
| Communication | Bidirectional RS232, optional USB cable |
| Data Storage | 200 GLP-compliant entries |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 password-protected methods |
| Self-Test | Yes |
| Firmware Upgrade | Network-enabled |
| Power | 4×AA batteries + optional universal AC adapter (benchtop) |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH |
| IP Rating | Portable—IP67 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TMES 1/2 |
| Pricing | Upon Request |
| Fiber Optic Core | Acrylic |
| Pixel Count | TMES 1: 3,500 |
| TMES 2 | 7,400 |
| Fiber Diameter | TMES 1: 35 mm |
| TMES 2 | 13 mm |
| Max Fiber Damage Tolerance | TMES 1: ≤2% |
| TMES 2 | ≤0.5% |
| Cable Material | SUS304 stainless steel braid with PVC jacket |
| Minimum Bend Radius | 40 mm |
| Cable Length | TMES 1: 1 m |
| TMES 2 | 3 m |
| Cable Diameter | TMES 1: 8 mm |
| TMES 2 | 5 mm |
| Light Source | 3.5 V, 0.7 A, 2.55 W LED-equivalent incandescent |
| Power Supply | 3 × C (LR14) alkaline batteries |
| Viewing Direction | Straight-ahead |
| Field of View | TMES 1: 60° |
| TMES 2 | 55° |
| Fixed Focus Distance | 10 mm |
| Waterproof Rating | Objective lens and fiber cable rated for 1–1.3 bar air pressure (IP65 equivalent for probe section) |
| Operating Temperature | −20 °C to +60 °C |
| Total Weight | 1,135 g |
| Packaging Dimensions | 360 × 270 × 80 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YSI 5000 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | VM-2000 |
| Price | Upon Request |
| Vibration Amplitude Range (Peak-to-Peak) | 2–1999 µm (±2 µm accuracy, 1 µm resolution) |
| Frequency Range | 10 Hz – 1 kHz |
| Measurement Update Rate | 1 reading/sec |
| Display | 4-digit LCD |
| Operating Temperature | −10 °C to +40 °C |
| Power Supply | 9 V alkaline battery (included) |
| Auto-Hold Function | Yes |
| Auto-Power-Off | 20 seconds of inactivity |
| Brand | Nittoseiko Analytech |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Detection Principle | Coulometric Karl Fischer Titration |
| Electrolysis Current | 430 mA |
| Titration Speed | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Measurement Range | 10 µg – 100 mg H₂O |
| Sensitivity | 0.1 µg H₂O |
| Precision | ±3 µg (for 10 µg–1 mg H₂O) |
| Cell Capacity | 150 mL |
| Display | 5.7-inch color LCD |
| Data Storage | ~100 recent measurements |
| File Capacity | 20 standard files + 50 composite files |
| Stirring | Magnetic stirring |
| Power Supply | AC 220/240 V, 50/60 Hz, 310 VA |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Dimensions (Analyzer) | 330 × 320 × 148 mm |
| Weight (Analyzer) | ~5 kg |
| Compliance | GLP-supporting architecture, audit-ready data handling, 21 CFR Part 11-compatible optional software modules |
| Brand | Xutongyongfu |
|---|---|
| Model | XT200 |
| Output Voltage (AC) | 10 kV (6 kV motor class), 15 kV (10 kV motor class) |
| Output Voltage (DC) | 15 kV (6 kV motor class), 25 kV (10 kV motor class) |
| Max Output Current | 550 mA (with compensating reactor) |
| Rated Transformer Capacity | 1.0–1.5 kVA |
| Input Power | AC 220 V ±10%, 50 Hz ±1 Hz |
| Display | Analog pointer meter |
| Voltage Accuracy | ±1.5% |
| Timing Range | 0–999 s (±0.5% accuracy) |
| Overcurrent Protection | 6.7 A |
| Zero-Position Interlock | Yes |
| Auto Trip on Timeout/Overcurrent | Yes |
| Dimensions (W×D×H) | 400 × 300 × 300 mm |
| Weight | 22 kg |
| Operating Temperature | –15 °C to +50 °C |
| Relative Humidity | ≤90% at +25 °C |
| Compliance | GB 50150–2006, DL/T 596–2005, DL/T 848.2–2004 |
Show next