Protein Purifier
Filter
Showing 61–82 of 82 results
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-3000 |
| Detection Wavelengths | 214 nm, 220 nm, 254 nm, 280 nm, 340 nm |
| Wavelength Accuracy | ±1 nm |
| Flow Cell | 80 µL volume, 4 mm path length |
| Absorbance Range | 0.05 A to 2 A (7 gain ranges) |
| Transmittance Range | 0–100 %T |
| Minimum Detectable Concentration | 48 µg/mL (for BSA at 280 nm) |
| Display | Triple-channel LED display of real-time OD values |
| Data Interface | USB and RS-232 (COM) |
| Software | Dedicated chromatography analysis software for Windows XP/7/10 (PC not included) |
| Compatibility | GE Healthcare AKTA system interface-ready |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear gradient support |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-97-1 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Wavelength Accuracy | ±1 nm |
| Flow Cell Path Length | 3 mm |
| Flow Cell Volume | 100 µL |
| Minimum Detectable Concentration | 48 µg/mL |
| Absorbance Range | 0.05 A – 2 A (7 ranges) |
| Transmittance Range | 0–100% T |
| Display | High-clarity LED, triple-channel OD readout |
| Control System | Embedded microcomputer chip |
| Compatibility | GE/AKTA-compatible column fittings |
| Gradient Type | Linear |
| Max. System Pressure | 3 MPa |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | HD-97-1 |
| Detection Wavelengths | 220 nm, 254 nm, 280 nm, 340 nm |
| Flow Cell | 100 µL volume, 3 mm path length |
| Absorbance Range | 0.05 A to 2 A (7 ranges) |
| Wavelength Accuracy | ±1 nm |
| Compatibility | GE/AKTA-compatible column interfaces |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear |
| Display | LED, triple-channel OD readout (A₂₂₀, A₂₅₄, A₂₈₀) |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-2000 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Detection Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Maximum System Pressure | 3 MPa |
| Light Source | LED (Lifespan > 50,000 h) |
| Optical Path Length | 2 mm |
| Sample Cell Volume | 10–120 µL |
| Baseline Noise | < 0.0001 A |
| Drift | ≤ 0.002 A/s |
| Sensitivity Range | 0.05–4 A (adjustable in 7 steps) |
| Zeroing | Dual-beam one-touch auto-zero |
| Display | High-definition blue-membrane LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 205 × 300 × 180 mm |
| Weight | 2.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3000 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Detector Type | UV-Vis Absorbance Detector |
| Detection Range | –6 AU to +6 AU |
| Pressure Rating | 3 MPa |
| Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Minimum Detectable Concentration | 20 µg/mL |
| Light Source | LED (Lifespan > 50,000 h) |
| Optical Path Length | 2 mm |
| Flow Cell Volume | 10–120 µL |
| Baseline Stability | Drift ≤ 0.002 A/h |
| Noise | < 0.0001 A (RMS) |
| Sensitivity Settings | 0.05–4 A full scale |
| Zero Adjustment | Dual-beam real-time auto-zero |
| Display | High-contrast blue-membrane LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 205 × 300 × 180 mm |
| Weight | 2.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3001 |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Detector Type | Dual-Beam UV Absorbance Detector |
| Detection Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Minimum Detectable Concentration | 20 µg/mL |
| Light Source | High-Stability LED (Lifespan > 50,000 h) |
| Optical Path Length | 2 mm |
| Flow Cell Volume | 10–120 µL |
| Baseline Noise | < 0.0001 AU |
| Drift | ≤ 0.002 AU/s |
| Absorbance Sensitivity Range | 0.05–2.0 AU (adjustable in 6 steps) |
| Zero Calibration | Real-time dual-beam auto-zero |
| Display | 10.1-inch capacitive touchscreen LCD |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 290 × 330 × 470 mm |
| Weight | 9 kg |
| Max Operating Pressure | 3 MPa |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3006 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Rate Accuracy | ±1.2% |
| Detection Range | −6 AU to +6 AU |
| Maximum Pressure | 3 MPa |
| UV Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Wavelength Accuracy | ±1 nm |
| Linearity | ±1.5% (0–2 AU) |
| Sample Cell Volume | 10 µL |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 345 × 380 × 255 mm |
| Weight | 6.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3007 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Detector Type | UV Absorbance Detector |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Rate Accuracy | ±1.2% |
| Detection Range | –6 AU to +6 AU |
| Maximum Pressure | 3 MPa |
| Wavelength Options | 260 nm, 280 nm, 295 nm, 310 nm |
| Wavelength Accuracy | ±1 nm |
| Linearity | ±1.5% (0–2 AU) |
| Sample Cell Volume | 10 µL |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 360 × 360 × 470 mm |
| Weight | 10.6 kg |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-3008 |
| Detection Range | 190–400 nm |
| Light Source | Deuterium Lamp (≥1000 h warranty) |
| Optical Path Length | 1 mm |
| Flow Cell Volume | 10–120 µL |
| Spectral Bandwidth | 6 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | ≤ ±0.1 nm |
| Baseline Noise | < 0.0001 AU |
| Baseline Drift | ≤ 0.002 AU/s |
| Wavelength Control | Stepper Motor–Driven Monochromator |
| Data Acquisition Rate | Dual-Channel High-Speed Sampling |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 340 × 330 × 175 mm |
| Weight | 6 kg |
| Integrated Touchscreen Display | 12-inch Industrial LCD |
| Brand | JIZHOU |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MCH |
| Pricing | Upon Request |
| Column Tube ID | 70–450 mm |
| Column Tube Height | 500–1000 mm |
| Packing Height Range | 0–82 cm |
| Max Operating Pressure | ≤8 bar |
| Weight | 15–230 kg |
| Material Compliance | USP Class VI (USP <88> In Vivo Biological Reactivity Testing) |
| Sealing | O-ring interface between platen and column tube |
| Screen Retention | Snap-fit design |
| Construction | Precision borosilicate glass tube (bubble-free, scratch-free surface) |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio3009 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Isocratic & Step Gradient |
| UV Detector Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Accuracy | ±1.2% |
| UV Detection Range | –6 to +6 AU |
| Linearity | ±1.5% (0–2 AU) |
| Maximum System Pressure | 3 bar |
| Conductivity Range | 0.001–400.00 mS/cm |
| Accuracy | ±2% (with temperature compensation) |
| Solvent Compatibility | Aqueous buffers, common chromatographic mobile phases, and biocompatible solutions used in protein purification |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JP-KeebioGO |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Types | Isocratic, Linear, and Step Gradients |
| Flow Rate Range | 0.001–25 mL/min |
| Flow Rate Accuracy | ±1.2% |
| UV Detection Range | –6 to +6 AU |
| Linearity | ±1.5% (0–2 AU) |
| Maximum System Pressure | 0–10 MPa (1500 psi) |
| Conductivity Range | 0.001–400.00 mS/cm |
| Accuracy | ±2% with temperature compensation |
| pH Range | 0–14 (measurable range 2–12) |
| Accuracy | ±0.1 with temperature compensation |
| Temperature Sensor Range | 0–100 °C |
| Accuracy | ±1 °C |
| Detector Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Wavelength Accuracy | ±1 nm |
| Repeatability | ±0.1 nm |
| Sample Cell Volume | 10 µL |
| Bubble Sensors | Installed at A/B inlets and sample inlet |
| Injection Valve | 3-position, 7-port, software-controllable, supporting Load/Inject/Waste modes |
| Fraction Collection Compatibility | JP-KeebioFC with configurable rack support |
| Data Export Format | Native Excel (.xlsx) |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 360 × 380 × 470 mm |
| Weight | 20 kg |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-KeebioStart |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Accuracy | ±1.2% |
| UV Detection Range | −6 to +6 AU (Linearity: ±1.5% within 0–2 AU) |
| Maximum Pressure | 3 MPa (30 bar) |
| Conductivity Range | 0.001–400.00 mS/cm |
| Conductivity Accuracy | ±2% |
| Temperature Detection Range | 0–100 °C (Accuracy: ±1 °C) |
| UV Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| UV Light Source | LED (Cold Light) |
| Wavelength Accuracy | ±1 nm |
| Sample Cell Volume | 10 µL |
| Mixer Volume | 200 µL (Static) |
| Fraction Collection | Optional JP-blupadFC collector with XY-axis positioning, peak-triggered collection (AU threshold, slope, conductivity), full-collection, and manual modes |
| Software | JP-blupad Chromatography Workstation (Registered Copyright No. 2019SR0680657) |
| Certifications | CN Utility Model Patent ZL201920802201.1, CN Design Patent ZL202130391697.0, CN Invention Patent ZL202110687106.3 |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 360 × 380 × 470 mm |
| Weight | 11 kg |
| Power Supply | 220 VAC |
| Brand | Keebio |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JP-Keebio |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Profile | Linear Gradient |
| UV Detection Range | –6 AU to +6 AU |
| Linearity | ±1.5% (0–2 AU) |
| Output Voltage Range | –500 mV to +1500 mV |
| Integration Sensitivity | 1 µV/s |
| Minimum Resolution | 0.1 µV |
| Minimum Peak Width | 0.1 s |
| Input Impedance | >10 MΩ |
| Repeatability | ±0.01% |
| Maximum Sampling Rate | 100 Hz |
| Interface | USB 2.0 |
| Operating Temperature | 4–40 °C |
| OS Compatibility | Windows 10 & 11 |
| Power Supply | 220 VAC |
| Dimensions (L×W×H) | 180 × 140 × 20 mm |
| Weight | 0.7 kg |
| Brand | KNAUER |
|---|---|
| Origin | Germany |
| Model | Bio FPLC |
| Pump Flow Ranges | 0.001–10 mL/min (10 mL module), 0.001–50 mL/min (50 mL module), 0.001–1000 mL/min (100–1000 mL modular pump head upgrade) |
| Detector | External flow cell UV-Vis detector with user-removable flow cell |
| Valve Configurations | Buffer selection, column switching, fraction collection |
| System Series | Compact (R&D scale), Pilot (process-scale) |
| Supported Chromatography Modes | Size-exclusion (SEC), Ion-exchange (IEX), Affinity, Hydrophobic Interaction (HIC) |
| Advanced Configuration Option | Simulated Moving Bed (SMB) for continuous purification |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MidiLab9000-Marker |
| Pricing | Available upon Request |
| Brand | BIO-RAD |
|---|---|
| Origin | USA |
| Model | NGC NFC |
| Max Flow Rate | 200 mL/min |
| Collection Vessel Compatibility | 96-well plates, microcentrifuge tubes, conical tubes, glass vials, and custom containers |
| Optional Features | Peltier-based cooling (4–25 °C), automated calibration routine |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows, supports audit trail generation per FDA 21 CFR Part 11 requirements (when used with compliant NGC Chromatography Software) |
| Vendor Type | Authorized Distributor |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ReadyToProcess Column |
| Pricing | Available Upon Request |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Biolot 50 |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Types | UV-Vis Absorbance Detector, Conductivity Detector, Evaporative Light Scattering Detector (ELSD) |
| Detection Wavelength Range | 190–800 nm |
| Flow Rate Range | 0.01–50 mL/min |
| Pressure Range | 0–20 MPa |
| Gradient Accuracy | ±0.5% ABS (dual-pump system) |
| Conductivity Range | 0–999.9 mS/cm |
| pH Range | 0–14 |
| Fraction Collector Capacity | 2 × 60 tubes (15 mm Ø × 150 mm H) |
| Software Compliance | FDA 21 CFR Part 11, CFDA GxP |
| Brand | Sepure Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Model | FCT2 |
| Price Range | USD 42,000 – 70,000 |
| Cooling Temperature Range | 5–15 °C |
| Ambient Operating Temperature | 15–35 °C |
| Max Flow Rate | 300 mL/min |
| Liquid-Wetted Materials | PEEK, FFKM, PP, PFA |
| Tube Rack Options | 11 mm, 13 mm, 16 mm, 30 mm ID |
| Collection Modes | Fixed Volume, Trigger-Based (TTL/Analog), Cyclic, Time-Programmed (Stepwise) |
| Power Input | 100–240 VAC, 50–60 Hz |
| Output | 24 VDC / 9.2 A |
| Dimensions (W×H×D) | 390 × 310 × 502 mm |
| Weight | 16 kg |
| RFID Integration | Yes |
| Sealed Dust-Resistant Enclosure | Yes |
| Independent Refrigeration & PID Temperature Control | Yes |
| Brand | Sepure Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Model | STP 1000R |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Detectors | UV-Vis (200–800 nm), Conductivity, pH |
| Flow Rate Range | 0.1–999.99 mL/min |
| Flow Rate Precision | RSD < 0.5% |
| UV Detection Range | 200–800 nm |
| Maximum System Pressure | 1.6 MPa |
| Conductivity Range | 0.001–999.99 mS/cm |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Platform | Freedom EVO-based modular system |
| Column Capacity | 96 RoboColumn® positions |
| Parallel Sample Processing | Up to 8 samples simultaneously |
| Compatible Columns | Atoll MediaScout® RoboColumns, GE Healthcare PreDictor™ RoboColumns |
| Application Scope | Expression screening, clone selection, media optimization, mAb purification condition scouting, resin evaluation, gradient method development, buffer exchange, desalting, concentration, and sample prep for crystallization or mass spectrometry |