- All
- Favorite
- Popular
- Most rated
| Brand | Future-Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | AW3000T |
| Measurement Range | 0.030–1.000 aw |
| Operating Environment | Ambient Temperature |
| Instrument Type | Benchtop Laboratory Analyzer |
| Net Weight | ~4.7 kg |
| Sensor Type | Mirror Condensation Dew Point Sensor |
| Accuracy | ±0.005 aw at 25 °C |
| Resolution | 0.0001 aw |
| Temperature Control | Peltier-controlled, Setpoint 25 °C |
| Temperature Resolution | 0.01 °C |
| Calibration | Multi-point, up to 20 standard solutions |
| Software Compatibility | Windows & Linux |
| Interface Language | Chinese GUI |
| User Access Control | Hierarchical operator permissions |
| Report Customization | Configurable print templates |
| Sample Pre-heating | Integrated |
| Sample Temperature Monitoring | IR-based non-contact sensor |
| Brand | ChangerTek |
|---|---|
| Model | AW1000T |
| Origin | Shanghai, China |
| Detection Principle | Vapor Pressure Ratio (Equilibrium Relative Humidity Method) |
| Display | 5-inch capacitive touchscreen (480 × 854 px) |
| Interface | Chinese-language UI |
| Temperature Control | Integrated Peltier element |
| Temperature Range | Ambient to 50 °C (user-selectable, ±0.2 °C accuracy, 0.1 °C resolution) |
| aw Measurement Range | 0.000–1.000 aw |
| aw Accuracy | ±0.005 aw at 25 °C |
| aw Resolution | 0.001 aw |
| Sample Temperature Sensing | Non-contact infrared sensor |
| Equilibration Method | Dynamic vapor equilibrium acceleration |
| Calibration | Multi-point, up to 11 certified standard salt solutions (full-range traceable calibration) |
| Data Storage | 2000 test records with timestamp, sample ID, temperature, and aw value |
| User Management | Role-based access control (admin/operator) |
| Dimensions | 340 × 230 × 170 mm |
| Weight | 4.7 kg |
| Compliance | Designed for GB/T 23490, ISO 21807, AOAC 978.18, USP <1112>, FDA Guidance for Industry (Food Safety Modernization Act – Preventive Controls), HACCP prerequisite programs, and GMP-aligned documentation workflows |
| Brand | Future-Spectrum |
|---|---|
| Model | AW2000T |
| Measurement Range | 0.000–1.000 aw |
| Temperature Control | Peltier-regulated at 25 °C (±0.01 °C) |
| Sensor Type | High-stability capacitive humidity sensor |
| Accuracy | ±0.008 aw at 25 °C |
| Resolution | 0.0001 aw |
| Sample Temperature Monitoring | Non-contact infrared sensor |
| Calibration | Multi-point, up to 20 reference standards |
| Operating System Compatibility | Windows, Linux |
| Interface | Chinese-language GUI with operator-level access control |
| Weight | 4.7 kg |
| Form Factor | Benchtop laboratory instrument |
Show next