Empowering Scientific Discovery

Pusen Tianchuang Optical Technology (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFuture-Spectrum
OriginShanghai, China
ModelAW3000T
Measurement Range0.030–1.000 aw
Operating EnvironmentAmbient Temperature
Instrument TypeBenchtop Laboratory Analyzer
Net Weight~4.7 kg
Sensor TypeMirror Condensation Dew Point Sensor
Accuracy±0.005 aw at 25 °C
Resolution0.0001 aw
Temperature ControlPeltier-controlled, Setpoint 25 °C
Temperature Resolution0.01 °C
CalibrationMulti-point, up to 20 standard solutions
Software CompatibilityWindows & Linux
Interface LanguageChinese GUI
User Access ControlHierarchical operator permissions
Report CustomizationConfigurable print templates
Sample Pre-heatingIntegrated
Sample Temperature MonitoringIR-based non-contact sensor
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFuture-Spectrum
OriginShanghai, China
ModelNIR-MULTI
Instrument TypeOnline/At-Line
Optical PrincipleFixed Grating with Array Detector (Non-Scanning)
Wavelength Range900–1700 nm
Sampling ModesDiffuse Reflectance and Transmission
Chemometrics SoftwareFlyChemometrics
Operating SystemsLinux & Windows (Multi-User Concurrent Access)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChangerTek
ModelAW1000T
OriginShanghai, China
Detection PrincipleVapor Pressure Ratio (Equilibrium Relative Humidity Method)
Display5-inch capacitive touchscreen (480 × 854 px)
InterfaceChinese-language UI
Temperature ControlIntegrated Peltier element
Temperature RangeAmbient to 50 °C (user-selectable, ±0.2 °C accuracy, 0.1 °C resolution)
aw Measurement Range0.000–1.000 aw
aw Accuracy±0.005 aw at 25 °C
aw Resolution0.001 aw
Sample Temperature SensingNon-contact infrared sensor
Equilibration MethodDynamic vapor equilibrium acceleration
CalibrationMulti-point, up to 11 certified standard salt solutions (full-range traceable calibration)
Data Storage2000 test records with timestamp, sample ID, temperature, and aw value
User ManagementRole-based access control (admin/operator)
Dimensions340 × 230 × 170 mm
Weight4.7 kg
ComplianceDesigned for GB/T 23490, ISO 21807, AOAC 978.18, USP <1112>, FDA Guidance for Industry (Food Safety Modernization Act – Preventive Controls), HACCP prerequisite programs, and GMP-aligned documentation workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChangerTek
OriginShanghai, China
ModelSVF-1000
Pump TypeOil-Free Diaphragm Pump
Ultimate Vacuum−0.08 MPa (200 mbar)
Maximum Positive Pressure≤0.18 MPa (1.8 bar)
Air Flow Rate25 L/min
Dimensions (L×W×H)27×31×24 cm
Weight5.5 kg
Motor Power68 W
Input Voltage220 V, 50 Hz
Programmable Pressure-Vacuum Interval0.1–9.9 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFuture-Spectrum
ModelAW2000T
Measurement Range0.000–1.000 aw
Temperature ControlPeltier-regulated at 25 °C (±0.01 °C)
Sensor TypeHigh-stability capacitive humidity sensor
Accuracy±0.008 aw at 25 °C
Resolution0.0001 aw
Sample Temperature MonitoringNon-contact infrared sensor
CalibrationMulti-point, up to 20 reference standards
Operating System CompatibilityWindows, Linux
InterfaceChinese-language GUI with operator-level access control
Weight4.7 kg
Form FactorBenchtop laboratory instrument