- All
- Favorite
- Popular
- Most rated
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MDS-3000-D |
| Temperature Range | Ambient + 5 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–9.999 mL/min |
| Reaction Coil Volume | 1 mL |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MDS-2000 |
| Temperature Range | Ambient to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–4.99 mL/min |
| Reaction Cell Volume | 1 mL |
| Flow Accuracy | ±0.5% |
| Flow Precision | 0.025% RSD |
| Pressure Range | 0–20 MPa |
| Power Supply | 220 V, 10 A |
| Dimensions (H×W×D) | 420 mm × 262 mm × 530 mm |
| Weight | 25 kg |
| Temperature Stability | ±0.02 °C |
| Temperature Setpoint Accuracy | ±0.1 °C |
| Temperature Equilibration Time | <20 min |
| Heating Power | 100 W |
| Standard Reaction Cell Volumes | 0.5 mL and 1 mL (optional range: 0.1–2 mL) |
| Fluidic Path Material | PEEK and optional stainless steel (SUS316) |
| Integrated Pulse Dampener | Yes |
| Backflow Prevention | Integrated check valve |
| Over-Temperature Protection | Active cutoff at 150 °C |
| Optional Online Degasser | Yes |
| Optional Pressurized Reagent Reservoir with SARAN™ tubing | Yes |
| Brand | Pribolab |
|---|---|
| Model | MDU-200 |
| Origin | Shandong, China |
| Derivatization Fluid Flow Rate | 1–2 mL/min |
| Reaction Coil Volume | 1 mL |
| Operating Temperature | Ambient |
| Compliance | AOAC Official Method 2005.08, AOCS Aa11-05, Ph. Eur. 2.8.18, Chinese Pharmacopoeia (2020 Ed.) & GB Standards |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Model | KRC-200 |
| Derivatization Light Source | Dual-wavelength UV (254 nm / 352 nm) |
| Flow Rate Range | 0.6–2.0 mL/min |
| Optimal Flow Rate | 1.2 mL/min |
| Reaction Cell Volume | 1 mL |
| Maximum Pressure Rating | 10 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±2 nm |
| Bandwidth | 2 nm |
| Light Source Lifetime | ≥8000 h |
| Dimensions (H×W×D) | 88 mm × 90 mm × 420 mm |
| Operating Temperature | 0–45 °C |
| Relative Humidity | 20–85 % RH |
| Power Supply | 220 V ±10 %, 50 Hz ±2 % |
| Compliance | AOAC 2005.08, AOCS Aa11-05, Ph. Eur. 2.8.18, Chinese National Standards & ChP Methods |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Model | MDS-3100 |
| Temperature Range | Ambient +5 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–9.999 mL/min |
| Reaction Coil Volume | 1 mL |
| Material Construction | PEEK fluidic path |
| Flow Accuracy | ≤0.5% |
| Flow RSD | ≤0.1% |
| Safety Features | Backflow prevention valve, overpressure protection (500 psi), overtemperature cutoff (150 °C), leak detection shutdown, inert gas pressurized reagent reservoir (optional) |
| Compliance | Designed for GLP/GMP-compliant HPLC workflows |
Show next