Second-hand Analytical Instruments
Filter
Showing 571–600 of 605 results
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY UPLC with Sampler Organizer |
| Product Category | Chromatography |
| Usage Duration | 4–5 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY UPC2 + QDa |
| Product Category | Mass Spectrometry Detector |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Instrument Model | ACQUITY UPC2 + QDa |
| Sample Injection Range | 0.5–10 µL |
| Primary Mobile Phase | Supercritical CO₂ with Co-solvent |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Ionization (API) coupled to single-quadrupole mass detection |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | ACQUITY UPLC H-Class Bio |
| Instrument Age | 5–7 years |
| Warranty | 6 months |
| Configuration | Bio-QSM Quaternary Solvent Manager, Bio-SM FTN Sample Manager, Column Manager, TUV Tunable UV/Vis Detector |
| Compliance | Designed for biopharmaceutical analysis under GLP/GMP-aligned workflows |
| Software Platform | Empower 3 (or later) compatible |
| Detection Principle | UV/Vis absorbance (190–700 nm, tunable) |
| Flow Path Material | Titanium, PEEK, and bio-inert stainless steel alloys |
| Maximum Pressure | 15,000 psi (103 MPa) |
| Injection Volume Range | 0.1–100 µL (with precision of ±0.3% RSD) |
| Column Temperature Range | 4–100 °C (±0.1 °C stability) |
| Gradient Delay Volume | < 100 µL (system-dependent) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | UPLC H-Class |
| Instrument Category | Liquid Chromatograph |
| Usage Duration | 5–7 years |
| Warranty | 6 months |
| Configuration | Quaternary Solvent Manager, Sample Manager-FTN, PDA Detector, FLR Detector, Column Heater |
| Certification Status | Refurbished & Fully Tested |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY I-Class |
| Product Category | Chromatography |
| Usage Duration | 3–4 years |
| Warranty Period | 6 months |
| Instrument Model | ACQUITY I-Class |
| Instrument Age | 4 years |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACQUITY UPLC Sample Manager |
| Product Category | Chromatography |
| Usage Duration | 5–7 years |
| Warranty | 6 months |
| Temperature Control Range | 4–40 °C (programmable in 1 °C increments) |
| Sample Capacity | Up to 8,064 samples (e.g., 21 × 384-well plates) |
| Ambient Operating Conditions | 20 °C, ≤90% RH (non-condensing) |
| Transport/Storage Range | −30 to 60 °C, ≤90% RH (non-condensing) |
| Acoustic Noise | <65 dB(A) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Acquity UPLC |
| Price Range | USD 38,000–64,000 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Configuration | Binary Solvent Manager, Sample Manager, PDA eλ Detector, FLR Detector, 30 cm Column Heater/Cooler |
| Condition | Refurbished & Fully Tested |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Waters ACQUITY UPLC |
| Price | USD 2,800 (FOB) |
| Product Category | Chromatography |
| Service Life | Refurbished & Fully Qualified |
| Warranty | 6 Months Limited Hardware Warranty |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Ultra-Performance Liquid Chromatograph |
| Model | ACQUITY UPLC |
| Age Range | 5–8 years |
| Warranty | 6 months |
| Regulatory Compliance | Designed to support GLP/GMP workflows |
| Software Platform | Empower 3 (or compatible legacy version) |
| Flow Rate Range | Up to 2 mL/min |
| Pressure Rating | Up to 15,000 psi |
| Detection Compatibility | UV/Vis, PDA, or MS interfaces (system-dependent configuration) |
| Column Temperature Control | Ambient to 90 °C |
| Injection Precision | ≤ 0.3% RSD (typical, with standard autosampler) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Ultra-High Performance Liquid Chromatography (UHPLC) Coupled with Single-Quadrupole Mass Spectrometer |
| Model | ACQUITY UPLC + QDa |
| Detection Principle | Electrospray Ionization (ESI) Single-Quadrupole Mass Spectrometry |
| Sample Introduction | LC-coupled ESI source |
| Mass Range | m/z 50–1200 |
| Detection Mode | Full Scan, SIM, AutoMS/MS (optional) |
| Data Acquisition Rate | Up to 10 Hz |
| Software Platform | MassLynx v4.2 or later (with QuanLynx, TargetLynx, and ChromaLynx modules) |
| Compliance | FDA 21 CFR Part 11 ready (audit trail, electronic signature support), GLP/GMP-compatible workflow |
| Warranty | 6 months limited hardware warranty |
| Operational Age | 4–5 years in active service (manufactured ~2013), total system age ≈ 7 years |
| Condition | Refurbished, fully tested and qualified per SpectraLab Scientific QC protocol |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | 2690/2695 |
| Configuration | Includes 2996 Photodiode Array Detector (PDA) |
| System Age | 7 years |
| Warranty | 6 months |
| Compliance | Fully tested per ASTM E2681 and USP <621> chromatographic system suitability protocols |
| Software | Empower 2 or 3 (pre-installed, license transferable per Waters policy) |
| Delivery | Bench-ready with validated operational status |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | 2695 |
| Product Category | Chromatography |
| Usage Duration | 5–7 years |
| Warranty | 6 months |
| Configuration | Includes Waters 2998 Photodiode Array (PDA) Detector |
| Condition | Refurbished and Fully Tested |
| Compliance | Meets original OEM functional specifications |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | Alliance 2695 (Refurbished) |
| Detector Configuration | 2998 Photodiode Array Detector, 2414 Refractive Index Detector, Fraction Collector III |
| Instrument Age | 4–5 years |
| Warranty | 6 months |
| Category | Liquid Chromatography System |
| Compliance Status | Fully refurbished and functionally validated per ISO/IEC 17025-aligned internal protocols |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | e-SAT/IN |
| Condition | Refurbished & Fully Tested |
| Regulatory Status | CE-marked, Compliant with IEC 61000-6-3 EMI Standards |
| Interface | RS-232 / TTL-compatible digital output |
| Input Range | ±10 V analog input, 12-bit resolution |
| Sampling Rate | Up to 1 kHz (typical in legacy HPLC system integration) |
| Power Supply | +5 V DC (supplied via host chromatograph interface) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | e2695 |
| Instrument Type | Liquid Chromatograph |
| Detector Type | Photodiode Array (PDA) |
| Software | Empower 3 |
| Operational Age | 7 years |
| Warranty | 6 months |
| Compliance Status | Fully Tested and Certified per SpectraLab Scientific Refurbishment Protocol |
| Included Modules | Quaternary Solvent Manager, Sample Manager (Autosampler), Column Heater/Cooler, Degasser, 2998 PDA Detector |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | LCT Premier XE |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Age | 4 years |
| Warranty | 6 months |
| Condition | Refurbished and Fully Tested |
| Compliance | Meets original factory specifications for mass accuracy, resolution, and sensitivity |
| Software | MassLynx 4.1 or later (license transferable per Waters policy) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | LCT Premier |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Ionization Sources | ESI, LockSpray, optional APCI/APPI/ESCI/NanoLockSpray/MUX |
| Mass Analyzer | Orthogonal Acceleration TOF (oa-TOF) |
| Detector | Dual Microchannel Plate (MCP) Assembly |
| Data Acquisition | 4.0 GHz Time-to-Digital Converter (TDC) with Onboard Histogramming |
| Control & Acquisition Software | MassLynx NT 4.x |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Condition | Factory-refurbished, fully tested and validated |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | Micromass LCT |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Configuration | Orthogonal Acceleration Reflectron TOF |
| Ionization Source | Z-Spray™ Atmospheric Pressure Ionization (API), Nano-ESI & ESI with LockSpray™ |
| Mass Accuracy | ≤5 ppm RMS (with LockSpray calibration) |
| System Integration | Coupled with Waters 2795 HPLC and Waters 2488 Multi-wavelength UV/Vis Detector |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Condition | Fully tested and refurbished by SpectraLab Scientific |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Micromass Quattro Micro |
| Price Range | USD 14,000 – 42,000 (FOB) |
| Product Category | Chromatography & Mass Spectrometry |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Included Components | Waters UPLC system, Edwards vacuum pump, full cable set, validated instrument control and data acquisition software (MassLynx v4.1 or later) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Instrument Type | Triple Quadrupole Liquid Chromatography–Tandem Mass Spectrometer (LC/MS/MS) |
| Configuration | UPLC-Coupled |
| Age | 5–7 years |
| Warranty | 6 months |
| Regulatory Compliance | Fully refurbished to meet ISO/IEC 17025-aligned operational standards |
| Software | MassLynx 4.1 or later, with validated acquisition and processing modules |
| Included Hardware | Binary Solvent Manager, Sample Manager with integrated column oven, Acquity PDA detector, Sample Organizer (optional), dedicated PC workstation |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Nano ACQUITY |
| Instrument Type | Liquid Chromatograph (LC) |
| Flow Rate Range | Nanoflow (50–1000 nL/min) |
| Maximum Pressure | 10,000 psi |
| Column Compatibility | Sub-2 µm particles |
| Detector | Acquity 2996 PDA with Nanoflow Flow Cell |
| Software | MassLynx v4.2 or later |
| Warranty | 6 months |
| Operational Age | 4–5 years |
| Compliance | ASTM D7598, USP <621>, ISO/IEC 17025-aligned operation |
| Data Integrity | 21 CFR Part 11-ready configuration (audit trail enabled) |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NanoAcquity UPLC + Q-TOF Premier |
| Product Category | Quadrupole-Time-of-Flight Mass Spectrometer (Q-TOF MS) |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Included Sources | ESI and Nano-Electrospray Ionization (nESI) with LockSpray™ Calibration Interface |
| Vacuum System | Edwards XDF 35i Turbo Molecular Pump |
| Data System | Lenovo ThinkCentre M58 PC pre-installed with MassLynx 4.1 software |
| UPS | Toshiba Uninterruptible Power Supply (Model UE3G2L036C61T, S/N 050702XXX) |
| UPLC Serial Numbers | EO5NPA-0XXN, EO5NPB-0XXN, EO5NPS-0XXN |
| Q-TOF Serial Number | HAA09X |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Quattro Micro |
| Instrument Type | Triple Quadrupole Gas Chromatography Tandem Mass Spectrometer (GC-MS/MS) |
| Configuration | Benchtop |
| Ionization Sources | ESI, APCI, ESCi |
| Mass Range | 5–3,000 m/z |
| Scan Speed | Up to 5,000 amu/s |
| Interface Technology | Z-Spray™ ion interface |
| Typical Service Life | 6–8 years |
| Warranty | 6 months post-installation |
| Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Waters SQD |
| Mass Range | m/z 50–1000 |
| Ionization Sources | ESI and APCI |
| Detection Modes | Full Scan, SIM, SIR |
| Software | MassLynx v4.2 or later |
| Dynamic Range | 10⁶–10⁷ |
| Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | Canada |
| Model | SYNAPT G1 HDMS |
| Instrument Type | Hybrid Quadrupole–Time-of-Flight (Q-TOF) Mass Spectrometer with Ion Mobility Separation (IMS) |
| Mass Analyzer Configuration | Dual-Mode TOF (V-mode: >10,000 resolution |
| W-mode | >17,500 resolution) |
| Mass Accuracy | <5 ppm (with lock mass correction, ≤1000 Da) |
| m/z Range | TOF mode — 20–100,000 (V-mode), 20–16,500 (W-mode) |
| Scan Rate | Up to 10 Hz (standard MS/MS), 5 Hz (PDR/E mode) |
| Included Modules | ACQUITY UPLC System (Binary Solvent Manager, Sample Manager, Column Manager, PDA Detector), ESI & NanoSpray Ion Sources, MassLynx 4.2 Software Suite, IMS Hardware, Vacuum System (Agilent G1960-80040 + Varian MS40+ POWERVAR), UPS, Dedicated PC Workstation |
| Refurbishment Standard | Factory-reconditioned per Waters OEM specifications |
| Operational Age | 5–7 years |
| Warranty | 6 months limited hardware warranty |
| Compliance | Fully compatible with GLP/GMP data integrity requirements when configured with audit-trail-enabled MassLynx and validated workflows |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Acquisition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI-MRM) |
| Software | MassLynx v4.2 or later |
| Compliance | Designed for GLP/GMP environments |
| Typical Service Life | 3–5 years (verified operational history, full service logs available upon request) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | TQD |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Transition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI) |
| Software | MassLynx v4.2 or later |
| Compliance | ASTM D7598, USP <1225>, FDA 21 CFR Part 11 (with audit trail enabled) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UPLC + Xevo TQD |
| Price Range | USD $26,000 – $39,000 (FOB) |
| Operational Age | 3–5 years |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo G2-S QTof |
| Instrument Type | Quadrupole Time-of-Flight (Q-TOF) Mass Spectrometer |
| Configuration | Integrated with ACQUITY H-Class UPLC System |
| Age | 4–5 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned protocols |
| Software | MassLynx v4.2 or later with UNIFI-ready architecture |
| Detection Mode | Full-scan MS, MSE, MS/MS (via ion mobility-enabled fragmentation), High-resolution accurate-mass (HRAM) acquisition |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo G2-XS QTof |
| Mass Range | 20–16,000 m/z |
| Resolution | >40,000 FWHM (at m/z 556) |
| TOF Mass Range | >100,000 m/z |
| Mass Accuracy | <1 ppm (external calibration) |
| Acquisition Rate | ≥30 spectra/sec |
| Detector | 6 GHz digitizer with 5-decade linear dynamic range |
| Instrument Age | 4 years |
| Warranty | 12 months |