Second-hand Analytical Instruments
Filter
Showing 511–540 of 605 results
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 1200L |
| Mass Range | 10–1500 u |
| Scan Rate | 500–6000 u/s |
| ESI SIM Sensitivity | 10 pg reserpine, S/N > 50:1 |
| ESI MS/MS Sensitivity | 10 pg reserpine, S/N > 50:1 |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Configuration | Triple quadrupole LC-MS/MS system with ProStar 210 dual LC pumps, ProStar 500 column valve module, Rainin CH-1 column heater, ProStar 410 autosampler, ProStar 330 PDA or 345 UV-Vis detector, rotary vacuum pump, dedicated P4 PC with Varian 1200/1200L MS workstation software and documentation |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 220 MSD |
| Mass Range | 10–650 amu |
| Scan Speed | 5600 amu/s |
| EI Full-Scan Sensitivity | 1 pg octafluoronaphthalene (OFN), S/N > 50:1 |
| CI Sensitivity | 5 pg benzophenone, S/N > 20:1 |
| Ionization Modes | Electron Impact (EI) and Chemical Ionization (CI), including liquid CI source |
| MSⁿ Capability | Up to n = 10 |
| Detector | Off-axis ±10 kV electron multiplier |
| Turbo Pump | 80 L/s |
| GC Compatibility | Varian 450 GC with PTV inlet, split/splitless injector, and FID |
| Operating Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ISO/IEC 17025-aligned internal protocols |
| Brand | Varian |
|---|---|
| Origin | USA |
| Instrument Model | 240-MS |
| Mass Analyzer Type | Ion Trap |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) |
| GC Compatibility | Varian 431 GC or 450 GC |
| Operational Age | ~4 years |
| Warranty | 6 months |
| Configuration | Complete GC-MS system with workstation, vacuum system, gas lines, and interface hardware |
| Regulatory Compliance | Designed to meet ASTM D3699, ISO 17025-relevant operational requirements for routine QC and research environments |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 300-MS |
| Instrument Type | Quadrupole Mass Spectrometer |
| GC Compatibility | Varian 431 or 450 GC |
| Autosampler | Varian CP-8400 |
| Ionization Modes | EI, CI, APCI (with patented 180° long-path collision cell and vortex gas flow design) |
| Interface Technology | Dual off-axis atmospheric pressure ionization (API) source with SelecTemp™ and SelecFlow™ programmable temperature/flow control |
| Scan Speed | High-speed polarity-switching full-scan acquisition |
| MS/MS Capability | Product ion scanning, precursor ion scanning, neutral loss scanning |
| Software Platform | Varian MS Workstation (compatible with GLP/GMP audit trail requirements) |
| Age | 4 years |
| Warranty | 6 months post-installation |
| Compliance | Designed to support ASTM D5845, EPA Method 8270/8260, USP <621>, ISO/IEC 17025 workflows |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 3400 |
| Column Oven Temperature Range | Ambient to 420 °C |
| Programmed Temperature Ramping | 16-step |
| Ramp Rate | 0.1–50 °C/min |
| Cool-down Time (250 °C → 50 °C) | <5 min |
| Injector Temperature Range | Ambient to 420 °C |
| Detector Options | TCD, FID, ECD, FPD, TSD |
| TCD Sensitivity | ≥12,000 mV·mL/mg (N₂ carrier) |
| FID Detection Limit | ≤2.7×10⁻¹² g/s (n-C₁₆) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/s (γ-HCH) |
| FPD Detection Limits | [P] ≤1×10⁻¹² g/s, [S] ≤6×10⁻¹¹ g/s |
| TSD Detection Limits | [N] ≤1×10⁻¹³ g/s, [P] ≤5×10⁻¹² g/s |
| Amplifier Time Programming | 5-step per detector |
| External Event Programming | 20-step across 4 events |
| Warranty | 6 months post-installation |
| Operational Age | 4 years |
| Compliance | Designed to support ASTM D3606, ISO 10301, USP <621>, and GLP-compliant workflows with audit-ready operation logs |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3800 PFPD |
| Price Range | USD $1,200–$6,500 (FOB) |
| Product Category | Gas Chromatography System |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Dimensions (H×W×D) | 54 × 66 × 56 cm |
| Weight | 43 kg |
| Column Oven Temp Range | Ambient +4°C to 450°C (–99°C to 450°C with LN₂ cooling |
| Max Ramp Rate | 100°C/min (oven), 180°C/min (1079 PTV) |
| Injector Types Supported | CP-1177 split/splitless, 1079 PTV, 1061 flash vaporizer, 1041 on-column |
| Pressure Range | 0–100 psi |
| Total Flow (at 10 psi) | up to 500 mL/min |
| PFPD Detection Limits | S: 1 pg/s, P: 100 fg/s, N: 20 pg/s |
| Linear Dynamic Range | S: 10³, P: 10⁴, N: 10² |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Varian 3900 |
| Price Range | USD 1,200–6,500 (FOB) |
| Product Category | Chromatography System |
| Operational Age | 3–4 years |
| Warranty | 6 months limited parts & labor |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 3900 |
| Price Range | USD $12,500 – $37,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Detector | Flame Ionization Detector (FID) |
| Injector Type | 1041 Packed Injector |
| Oven Temperature Range | Ambient +10 °C to 450 °C |
| Cooling Rate | 450 °C to 50 °C in ≤5.2 min |
| Injector Pressure Range | 0–100 psi |
| Total Flow at 10 psi | 500 mL/min |
| FID Sensitivity | 2 pg C/s |
| Flame-Out Detection | Yes |
| Auto-Reignition | Yes |
| Data Acquisition Rate | 80 Hz |
| Power Requirement | 120 VAC ±10%, 60 Hz ±2%, 6 A, 1.3 kW |
| Dimensions (W×D×H) | 31.8 cm × 55.9 cm × 55.1 cm |
| Serial No. | 0393301701 |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 4000 |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Product Category | Chromatography System |
| Operational Age | 4–5 Years |
| Warranty | 6 Months Limited Hardware Warranty |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 4000 GC/MS/MS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Configuration | Integrated GC-MS/MS System with CP-8400 Autosampler |
| Operational Age | 3–4 years (total service life: ~7 years) |
| Warranty | 6 months |
| Compliance | Fully refurbished and functionally validated per ISO/IEC 17025-aligned internal protocols |
| Software Platform | Varian MS Workstation v6.x or later (licensed, pre-installed) |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 430-GC |
| Instrument Type | Gas Chromatograph |
| Configuration | Single-channel, FID/TCD-ready |
| Column Oven Capacity | Standard 1/4" or 1/8" packed column compatible |
| Pneumatic Control | Fully digital electronic pressure control (EPC) |
| Injector Options | Split/splitless capillary injector or packed column injector |
| Detector Options | Flame Ionization Detector (FID), Thermal Conductivity Detector (TCD) |
| Autosampler Compatibility | Medium- and high-capacity liquid autosamplers (e.g., Varian 8400/8200 series) |
| Software Platform | Galaxie CDS v2.x or later |
| Operational Age | ~4 years |
| Warranty | 6 months limited parts and labor |
| Compliance | Designed to meet ASTM D3606, D1319, ISO 6974, and USP <621> chromatographic system suitability requirements |
| Data Integrity | Audit trail-enabled Galaxie software compliant with FDA 21 CFR Part 11 (when configured with user authentication and electronic signature modules) |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 431-GC |
| Instrument Type | Gas Chromatograph |
| Age | 3–4 years |
| Warranty | 6 months |
| Configuration | GC-only or GC/MS-integrated system (LUI-free operation) |
| Compliance | Designed for ASTM D3606, ISO 6416, USP <621>, and EPA Method 8021B workflows |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 450-GC |
| Product Category | Chromatography |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Detector Options | FID / TSD / PFPD |
| Autosampler | CP-8410 |
| Injector Types | CP-1177 (split/splitless), CP-1079 (PTV) |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Oven Program | 7-ramp, 8-step |
| Max Simultaneous Detectors | 3 |
| Max Simultaneous Inlets | 3 |
| Software | Star Chromatography Workstation (English & Chinese versions available) |
| Compliance | Designed for GLP environments |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 460LC |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography Systems |
| Operational Age | 4–5 years |
| Warranty | 6 months limited |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 720-ES |
| Instrument Type | Elemental Analyzer (ICP-OES) |
| Detector | VistaChip II CCD |
| Observation Modes | Axial and Radial |
| Software | ICP Expert II |
| Warranty | 6 months |
| Operational Age | 3–4 years |
| Cooling System | Lytron recirculating chiller |
| Sample Introduction | Compatible with SPS-3 autosampler |
| Compliance | Designed to meet ASTM D1976, ISO 11885, USP <232>/<233>, and EPA Methods 200.7, 200.8, and 6010D requirements |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | AA240Z |
| Instrument Type | Atomic Absorption Spectrometer |
| Detection Principle | Zeeman-effect background correction with AC-modulated magnetic field |
| Lamp Positions | 4 fixed |
| Atomizer | GTA 120 Zeeman graphite furnace |
| Autosampler | PSD 120 |
| Software Platform | Varian SpectrAA |
| Operational Age | 4 years |
| Warranty | 6 months |
| Compliance | Designed to meet ASTM E178, ISO/IEC 17025–compatible operation protocols |
| Calibration Verification | Performed per NIST-traceable standards prior to refurbishment |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | Archon 5100 |
| Instrument Type | Purge and Trap Autosampler |
| Application Scope | Aqueous and Solid (Soil/Sediment) Samples |
| Condition | Refurbished, Fully Tested |
| Operational Age | 4 Years |
| Warranty | 6 Months Limited |
| Compliance | Designed to meet EPA Methods 502.2, 524.2, 624, and 8260 requirements |
| Software Interface | Compatible with Varian Star™ or third-party GC/MS data systems |
| Sample Throughput | Up to 40 samples per run (standard carousel configuration) |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | Archon 5100A |
| Instrument Type | Purge-and-Trap Autosampler |
| Application Scope | Aqueous and Solid (Soil/Sediment) Samples |
| Compliance Context | Designed for EPA Methods 502.2, 524.2, 624, 8260D |
| Software Interface | Compatible with Varian Star™ Chromatography Data System (CDS) |
| Warranty | 6-month limited hardware warranty |
| Refurbishment Standard | Factory-aligned calibration verification and leak-tested per ASTM D3694 Annex A1 |
| Operational History | ~4 years of documented laboratory use under GLP conditions |
| Brand | Varian |
|---|---|
| Origin | USA |
| Instrument Type | Purge and Trap Autosampler |
| Application | Aqueous Sample Introduction for GC Analysis |
| Model Designation | Archon (Aqueous-Only Configuration) |
| Operational Age | 3–4 Years |
| Warranty | 6 Months Limited Hardware Warranty |
| Compliance Context | Designed to meet ASTM D5024, EPA Method 502.2, EPA Method 624, and ISO 15681-1 requirements for volatile organic compound (VOC) analysis in water |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | Archon |
| Sample Tray Options | 51-position or 81-position |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Category | Chromatography Accessories |
| Import Status | Imported |
| Distributor Type | Authorized Reseller |
| Brand | Varian |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | UV-Visible Spectrophotometer |
| Model | Cary 100 |
| Spectral Range | 190–1100 nm |
| Optical Resolution | ≤1.0 nm (typical) |
| Photometric Accuracy | ±0.002 A (at 0.5 A, NIST-traceable standards) |
| Stray Light | <0.01% at 220 nm and 340 nm |
| Scan Speed | Up to 24,000 nm/min |
| Data Acquisition Rate | Up to 80 points/sec |
| Detector | Raman-corrected photomultiplier tube (PMT) |
| Beam Geometry | Double-beam, ratio-recording |
| Compliance | ASTM E275, ISO 6223, USP <857>, GLP-ready configuration |
| Warranty | 6 months limited hardware warranty |
| Refurbishment Standard | Performed per Varian OEM service protocols |
| Operational Age | 4 years (prior to refurbishment) |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | Cary 1E |
| Instrument Type | UV-Visible Spectrophotometer |
| Optical Configuration | Single-beam, fixed-slit monochromator |
| Wavelength Range | 190–1100 nm |
| Typical Photometric Accuracy | ±0.005 A (at 0.5 A, NIST-traceable standards) |
| Stray Light | <0.05% at 220 nm (NaI), <0.1% at 340 nm (NaNO₂) |
| Scan Speed | Up to 2,400 nm/min |
| Data Resolution | 0.1 nm |
| Detector | Silicon photodiode |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 44 × 42 × 22 cm |
| Weight | 14.5 kg |
| Age | 4 years |
| Warranty | 6 months limited parts and labor |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | Cary 300 |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system, fully tested and calibrated |
| Compliance | Meets original Varian factory specifications for optical performance and photometric accuracy |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Cary 300/100 |
| Product Category | Spectroscopy |
| Usage Duration | 4–5 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | Cary 400 |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system with standard accessories |
| Compliance | Fully tested per ASTM E275 and ISO 6223 standards for photometric accuracy and wavelength calibration |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | Cary 4000 |
| Wavelength Range | 175–900 nm |
| Optical Resolution | Adjustable down to 0.01 nm |
| Absorbance Range | Up to 8 Abs (with reference beam attenuator) |
| Software Platform | Cary WinUV (Windows-based, modular architecture) |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Fully tested refurbished unit with all standard accessories and documentation |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | Cary 5E |
| Instrument Type | UV-Vis-NIR Spectrophotometer |
| Optical Range | 175–3300 nm |
| Configuration | Double-beam, Scanning |
| Detector Type | Dual-detector system (PMT + InGaAs/PbS) |
| Typical Age | 4 years |
| Warranty | 6 months |
| Compliance | Meets ASTM E275, ISO 6298, and USP <857> optical performance verification protocols |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | Cary 5G |
| Instrument Type | UV-Vis-NIR Spectrophotometer |
| Optical Range | 175–3300 nm |
| Configuration | Double-beam, Scanning |
| Age | 4 years |
| Warranty | 6 months |
| Compliance | ASTM E275, ISO 9001-certified refurbishment process |
| Software | Cary WinUV v5.x (with spectral acquisition, quantitative analysis, and kinetics modules) |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CP 3800 / CP 8200 |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Configuration | Dual-Detector GC System (TSD + ECD) |
| Refurbishment Standard | Factory-Refurbished & Performance-Verified |
| Compliance | Fully Tested per ASTM D3606, EPA Method 8081B, and USP <621> Chromatography Guidelines |
| Brand | Varian |
|---|---|
| Origin | Canada |
| Model | CP-3800 |
| Instrument Type | Gas Chromatograph (GC) |
| Column Oven Temperature Range | Ambient +4 °C to 450 °C (−99 °C to 450 °C with liquid nitrogen cooling |
| Max Ramp Rate | 100 °C/min (oven), 180 °C/min (PTV injector) |
| Injector Options | CP-1177 Split/Splitless, 1079 Programmable Temperature Vaporizing (PTV), 1061 Flash Vaporizer (packed/large-bore), 1041 Column-Head Inlet (packed/large-bore) |
| Pressure Control Range | 0–100 psi |
| Flow Control | Manual or Electronic Flow Control (EFC) |
| Dimensions (H×W×D) | 54 × 66 × 56 cm |
| Weight | 43 kg |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 5–95% RH |
| Power Supply | 101/120/230 V AC (±10%) |
| Reconditioned Unit Age | 3–4 years |
| Warranty | 6 months |