Second-hand Analytical Instruments
Filter
Showing 61–90 of 605 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6520 |
| Product Type | Mass Spectrometer |
| Usage Duration | 4–5 years |
| Warranty Period | 6 months |
| LC Configuration | Agilent 1200 Series (G1312A Binary Pump, G1313A Autosampler, G1316A Column Compartment, G1322A Degasser) |
| Software Platform | MassHunter Workstation |
| Mass Accuracy (MS) | <2 ppm |
| Mass Accuracy (MS/MS) | <5 ppm |
| Resolution (FWHM) | 20,000 at m/z 556 |
| Dynamic Range (within spectrum) | 10× improvement without sensitivity loss |
| Acquisition Speed | up to 10 MS/MS spectra/sec |
| Mass Range | m/z 25–20,000 |
| Included Hardware | Dedicated PC with pre-installed MassHunter software and calibration kits |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6530A |
| Configuration | LC-Q-TOF System with Jet Stream Electrospray Ionization Source |
| Warranty | 90-day hardware warranty |
| Compliance | Fully tested and validated per Agilent factory specifications |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6540A |
| Instrument Type | Quadrupole Time-of-Flight Mass Spectrometer (Q-TOF) |
| Configuration | Integrated with Agilent 1260 HPLC (G1312B binary pump, G1367E high-performance autosampler, G1316A column oven, G1322A vacuum degasser, G1330B autosampler chiller) |
| Software | MassHunter Workstation (Qualitative & Quantitative Analysis) |
| Dynamic Range | Up to 5 orders of magnitude (within-spectrum) |
| Acquisition Rate | Up to 50 spectra/sec |
| Ion Source | Dual AJS (Advanced Jet Stream) ESI/APCI interface |
| Mass Accuracy | < 2 ppm (internal calibration), < 3 ppm (external calibration) |
| Mass Resolution | > 35,000 FWHM (at m/z 922) |
| Warranty | 6 months |
| Service History | Fully refurbished and performance-verified by SpectraLab Scientific |
| Usage Duration | 4 years |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6850 II |
| Price Range | USD 6,800–13,600 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GC-6850 Series II |
| Usage Duration | 4–5 Years |
| Warranty | 6 Months |
| Dimensions | 56.8 cm (L) × 28.3 cm (W) × 49.0 cm (H) |
| Column Oven Cooling Capability | Down to –20 °C |
| Detector Options | FID, TCD, FPD, micro-ECD (US only), 5977A MSD |
| Injector Types | SSL, Packed Column, Cold-On-Column, PTV |
| Electronic Pressure Control (EPC) | Yes |
| Autosampler Capacity | Up to 27 × 2 mL vials or 22 × 4 mL vials |
| Network Interface | Built-in LAN |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6850A (G2630A) with FID |
| Product Category | Chromatography |
| Usage Duration | 2–3 years |
| Warranty Period | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6850A (G2630A), COC |
| Dimensions | 56.8 cm × 28.3 cm × 49.0 cm |
| Operating Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | Up to 120 °C/min |
| Cooling Rate | Capable of cooling to −20 °C |
| EPC Control | Full electronic pressure/flow control for inlet and detector |
| Sample Capacity | 27 × 2 mL vials or 22 × 4 mL vials (with optional turret) |
| Compliance | ASTM D3606, ISO 10301, USP <621>, FDA 21 CFR Part 11–ready software environment |
| Warranty | 6 months limited hardware warranty |
| Usage History | Refurbished unit with verified operational history of ≤4 years |
| Software Platform | Agilent ChemStation (basic configuration) |
| Network Interface | Integrated 10/100Base-T Ethernet (LAN) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6850N, FID, SSI |
| Usage Duration | 2–3 Years |
| Warranty | 6 Months |
| Detector | Flame Ionization Detector (FID) |
| Injector | Split/Splitless Injector (SSI) |
| Column Oven Temperature Range | 5 °C above ambient to 350 °C |
| Maximum Injector/FID Temperature | 375 °C |
| Carrier Gas Flow Control | Electronic Pressure Control (EPC) capable |
| Data Acquisition Rate | Up to 200 Hz |
| Detection Limit | <5 pg C/s (propane, N₂ carrier, 0.29 mm ID jet) |
| Linear Dynamic Range | 10⁷ (±10%) |
| Column Compatibility | 50–530 µm ID capillary columns |
| Communication Interface | Integrated 10/100Base-T Ethernet (LAN-ready) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890 |
| Product Category | Chromatography Systems |
| Operational Age | 5–7 years |
| Warranty | 6 months |
| Regulatory Compliance | Designed for GLP/GMP environments with audit-trail-capable data handling |
| Software Platform | OpenLAB CDS ChemStation (legacy-compatible) |
| EPC Control | 13-channel digital electronic pressure control (EPC), pressure accuracy ±0.01 psi |
| Temperature Program | Oven ramp rate up to 120 °C/min, temperature stability ±0.01 °C |
| Data Acquisition Rate | Up to 100 Hz |
| Retention Time Locking (RTL) | Enabled for cross-instrument method transfer |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 6890 GC, PAL LSI 85 |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Chromatography Systems |
| Operational Age | 2–3 years |
| Warranty | 6 months limited hardware warranty |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890 with FPD |
| Product Category | Chromatography |
| Operational Age | 2–3 Years |
| Warranty | 6 Months |
| Detection Limits | <60 fg P/s and <3.6 pg S/s (methyl parathion) |
| Dynamic Range | >10³ for S, >10⁴ for P (methyl parathion) |
| Selectivity | 10⁶ gS/gC and 10⁶ gP/gC |
| Data Acquisition Rate | Up to 200 Hz |
| EPC Gas Flow Ranges | Air 0–130 mL/min, H₂ 0–250 mL/min, Make-up Gas 0–130 mL/min |
| FPD Operating Temperature | Up to 250 °C |
| Configuration | Dual-wavelength FPD |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890 GC + GERSTEL MACH |
| Product Category | Gas Chromatography |
| Operational Age | 4–5 Years |
| Warranty | 6 Months |
| Compliance | Fully Refurbished & Factory-Tested per ISO/IEC 17025-aligned procedures |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890 / 7694A |
| Price Range | USD 13,500 – 40,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 6890 GC with OI 4430/4410 Tandem PID/FID Detector |
| Usage Duration | 2–3 Years |
| Warranty | 6 Months |
| Detection Principle | Photoionization + Flame Ionization Detection |
| Column Compatibility | Packed & Capillary Columns |
| Max FID Temperature | 375 °C |
| FID Detection Limit | <5 pg C/s (propane, N₂ carrier, 0.29 mm jet) |
| FID Linear Dynamic Range | 10⁷ (±10%, full-range auto-scaling) |
| Data Acquisition Rate | Up to 200 Hz |
| Carrier Gases | He, N₂, H₂ |
| Air Flow Range | 0–800 mL/min |
| H₂ Flow Range | 0–100 mL/min |
| Makeup Gas Flow Range | 0–100 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890, AED |
| Price Range | USD $6,800 – $13,600 (FOB) |
| Product Category | Chromatography |
| Operational Age | 2–3 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 6890N, Dual NPD |
| Price Range | USD 1,500–7,500 (FOB) |
| Product Category | Chromatography |
| Service Life | 2–3 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890 Plus GC + 5973 MSD |
| Configuration | GC-MS System for VOC/SVOC Quantification per GB/T 23986.2–2023 |
| Condition | Professionally Refurbished & Functionally Verified |
| Compliance | Fully Compatible with ASTM D6886, ISO 11890-2, and US EPA Method 8260D workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 6890 GC |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Product Category | Chromatography System |
| Operational Age | 5–7 years |
| Warranty | 6 months limited hardware warranty |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890A |
| Configuration | Split/Splitless Inlet + FID Detector + G6501B Autosampler |
| Oven Cooling Rate | Up to 250 °C/min (typical for 6890 series) |
| EPC Control | 5th-generation Electronic Pressure Control |
| Software Platform | ChemStation (G1701DA or later) |
| Warranty | 6 months |
| Operational Age | ~4 years |
| Compliance | Designed to meet ASTM D3606, USP <621>, ISO 17025-relevant operational requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 6890N |
| Product Category | Chromatography System |
| Operational Age | 2–3 Years |
| Warranty | 6 Months |
| Detector | FID (Detection Limit: <5 pg C/s on propane) |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Split/Splitless Inlet Pressure Range | 0–100 psi (optional 0–150 psi) |
| Total Flow Range (Split/Splitless) | 0–200 mL/min N₂, 0–1000 mL/min H₂ or He |
| Integrated Autosampler Control | Agilent 7683 Series |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 6890N with Autosampler |
| Product Category | Chromatography |
| Usage Duration | 4–5 Years |
| Warranty Period | 6 Months |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 6890N with G1888 |
| Detection Principle | Flame Ionization Detection (FID) |
| Minimum Detectable Level (Tridecane) | <1.8 pg C/s |
| Linear Dynamic Range | >10⁷ (+10%) |
| Data Acquisition Rate | Up to 200 Hz |
| EPC Control Channels | 3 (Air, H₂, Makeup Gas) |
| Air Flow Range | 0–800 mL/min |
| H₂ Flow Range | 0–100 mL/min |
| Makeup Gas Flow Range | 0–100 mL/min |
| Maximum Injector/Transfer Line Temperature | 450°C |
| Sample Introduction | Automated Headspace via Agilent G1888 |
| System Age | 3–4 years |
| Warranty | 6 months |
| Compliance | Designed for ASTM D3606, USP <467>, ISO 11843-1, and GLP-compliant workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890N + 5973N |
| Price | USD 22,000 (FOB) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N–5975 |
| Instrument Type | Gas Chromatography–Mass Spectrometry (GC–MS) System |
| Condition | Pre-owned, Fully Refurbished & Performance-Verified |
| Operational Age | 2–3 years |
| Warranty | 6 months limited hardware warranty |
| Compliance | Designed to meet ASTM D1945, EPA Method 8260/8270, USP <621>, and ISO/IEC 17025-aligned laboratory requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N |
| Detector Options | FID (detection limit <5 pg C/s on propane), TCD, ECD, NPD, FPD, FTD |
| Oven Temperature Range | +4 °C above ambient to 450 °C |
| Inlet Pressure Range | 0–100 psi (optional 0–150 psi) |
| Carrier Gas Flow Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Integrated Control | Agilent 7683 Autoinjector |
| Compliance | ASTM D3606, D5503, ISO 10301, USP <621>, FDA 21 CFR Part 11 ready (with ChemStation Plus configuration) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent 6890N (Refurbished) |
| Price Range | USD 4,200 – 11,200 |
| Detector | FID (Detection Limit: <5 pg C/s on propane) |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Split/Splitless Injector Pressure Range | 0–100 psi (optional 0–150 psi) |
| Total Flow Range (Split/Splitless) | 0–200 mL/min N₂, 0–1000 mL/min H₂ or He |
| Autosampler | Integrated Agilent 7683 Control |
| GC Speed | Up to 10× faster than conventional GC |
| Compliance | Designed for ASTM D3606, D5186, ISO 6416, USP <621>, FDA 21 CFR Part 11-ready configurations available |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 6890N-5975(G3170A) |
| Product Type | Mass Spectrometer |
| Warranty | None |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 6890N-5975(G3172A) |
| Mass Spectrometer Type | Single Quadrupole MSD |
| Instrument Age | 3–4 Years |
| Vacuum System | Pfeiffer Dual-Stage Rotary Vane Pump with Agilent G1099 Exhaust Oil Mist Filter |
| Autosampler | Gerstel MPS2 Multi-Purpose Sampler |
| Configuration | Complete GC/MS System with PC, Acquisition Software (ChemStation E.02.02 or later), and Full Cabling Set |
| Condition | Fully Tested & Verified Operational |
| Warranty | Not Included |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 700 ICP-OES |
| Wavelength Range | 175–785 nm (continuous, gap-free) |
| Focal Length | 0.4 m |
| Echelle Grating Density | 97.4 lines/mm |
| Signal Stability | ≤1.0% RSD (4-hour measurement) |
| RF Generator Frequency | 40.68 MHz |
| Plasma Output Power | 700–1700 W |
| Plasma Cooling Gas Flow | 0–22.5 L/min (adjustable) |
| Detector | High-resolution CCD with >1 million pixels, anti-blooming architecture |
| Compliance | Fully compliant with FDA 21 CFR Part 11 for electronic records and signatures |
| Warranty | 12 months post-installation qualification |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole GC-MS |
| Configuration | Standalone Mass Spectrometer (requires compatible Agilent GC, e.g., 7890B/7820A) |
| Detection Principle | Electron Ionization (EI) and Chemical Ionization (CI) |
| Mass Range | 10–1000 m/z |
| Scan Speed | Up to 20,000 Da/sec in MRM mode |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in EI MRM mode |
| Mass Resolution | Unit mass resolution (0.7 Da at peak apex) |
| Vacuum System | Dual-stage turbomolecular pump (≥260 L/s for MS region) |
| Interface Temperature | Up to 350 °C |
| Data System Compatibility | Agilent MassHunter Workstation (vB.08.00 or later) |