- All
- Favorite
- Popular
- Most rated
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-G10 |
| Measurement Principle | Photosynthetically Active Radiation (PAR) Interception Method |
| Instrument Type | Handheld Portable |
| Spectral Range | 400–700 nm |
| PAR Sensor Resolution | 1 μmol·m⁻²·s⁻¹ |
| Operating Temperature | 0–60 °C |
| Relative Humidity | 0–100% RH |
| Power Supply | Dual 18650 Li-ion Batteries (3500 mAh each) |
| Charging Interface | USB-C, 5 V DC |
| Probe Length | 100 cm |
| Total Unit Length | 128 cm |
| Cable Length (External Sensor) | 2 m |
| Data Storage | 16 GB Internal + Standard SD Card Slot |
| Connectivity | Bluetooth 5.0, Optional Wi-Fi Module |
| Display | High-Brightness Touchscreen with Dual-Language UI (English/Chinese) |
| Auto-Measurement Interval | 1–60 min (up to 999 cycles) |
| GPS Integration | Built-in GNSS Receiver for Georeferenced LAI Mapping |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | IN-XM01 |
| Price | USD 3,500 (FOB) |
| Camera Resolution | 4000 × 3000 |
| Dual-Camera Setup | 50 MP + 12 MP |
| Measurement Accuracy (Spike Count) | ≤ ±3% |
| Live-Field Spike Detection Error | ±1% |
| Thousand-Kernel Weight (TKW) Accuracy | ±2% (calibrated to ≤0.5% residual error) |
| Adjustable Calibration Rod Range | 1000 mm × 1000 mm × (610–1120) mm & 1000 mm × 1000 mm × (1010–1920) mm |
| On-Device Storage | 256 GB |
| Operating System | Android-based UI with touch interface |
| Connectivity | Wi-Fi / 4G LTE |
| Data Export Format | Excel (.xlsx) with embedded GPS timestamps |
| Language Support | English & Chinese (toggleable) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Agricultural Instrumentation |
| Model | IN-KZ04 |
| Instrument Type | Seed Morphometric & Gravimetric Analyzer |
| Imaging Resolution | 1600 dpi × 1600 dpi (A3-format color scanner) |
| Weighing Interface | RS232-enabled precision balance |
| Sample Throughput | Up to 10 whole ears, 35 cross-sections, or ~1000 kernels per imaging session |
| Counting Speed | 1500–4000 seeds/min |
| Counting Accuracy | ≤ ±0.5% (manual verification enables 100% correction) |
| Dimensional Measurement Accuracy | ≤ ±0.3% |
| TKW Calculation Error | ≤ ±0.5% |
| Supported Output Formats | JPG, TIFF, BMP, PNG, Excel (.xlsx), CSV |
| Software OS Requirement | Windows 10 or later |
| Dual-Language UI | Embedded Chinese/English toggle |
| Cloud Synchronization | Device-ID-bound encrypted data upload and remote access |
| Brand | COMECAUSE |
|---|---|
| Model | IN-ZS300 |
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Category | Domestic (PRC) |
| Power Supply | AC 220 ± 22 V / DC 12 V + 5 V (built-in 4800 mAh Li-ion battery) |
| Power Consumption | ≤ 5 W |
| Optical Channels | 4 fixed solid-state cuvette modules |
| Wavelengths | Red 680 ± 2 nm, Blue 420 ± 2 nm, Green 510 ± 2 nm, Orange 590 ± 4 nm |
| Display | 7.0″ color LCD, 1024 × 600 resolution |
| Operating System | Android 5.1, quad-core CPU ≥ 1.8 GHz, 16 GB internal storage |
| GPS Module | Integrated real-time geotagging |
| Data Connectivity | Wi-Fi, dual USB ports, thermal printer (no ribbon required) |
| IP Rating | IP65 |
| Battery Life | Up to 10 hours continuous operation |
| Repeatability Error | ≤ 0.03% (K₂Cr₂O₇ solution) |
| Stability | Drift < 0.3% in 1 h (transmittance), < 0.001 absorbance units in 2 h |
| Linearity Error | ≤ 0.1% (CuSO₄ solution) |
| Sensitivity | Red ≥ 4.5 × 10⁻⁵, Blue ≥ 3.17 × 10⁻³, Green ≥ 2.35 × 10⁻³, Orange ≥ 2.13 × 10⁻³ |
| Sample Throughput | Pb, As, Cr, Cd, Hg: ~60 min total (incl. extraction & reagent prep) |
| Fe, Zn, Cu | ~30 min |
| Mn | ~40 min |
| Detection Targets | Pb, As, Cr, Cd, Hg, Ni, Al, F, Ti, Se, Fe, Zn, Mn, Cu in soil, fertilizer, food, vegetables, and fruit |
| Compliance | Meets functional requirements for field-deployable spectrophotometric heavy metal screening per ASTM D7574-22 (Standard Guide for Field Screening of Metals in Soils Using Portable XRF and Colorimetric Methods), supports GLP-aligned data traceability (time-stamped, GPS-tagged, user-authenticated records) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Portable |
| Measurement Range | 0.05–100 NTU |
| Operating Temperature | 0–50 °C |
| Wavelength Range | 340–800 nm |
| Measurement Principle | Nephelometric (90° scattered light detection) |
| Accuracy | ≤5% FS |
| Repeatability | <0.5% |
| Stability | <0.5% |
| Light Source | Imported Cold LED (Lifespan ≥100,000 h) |
| Display | 3.5-inch Color TFT Touchscreen |
| Data Storage | >80,000 Records |
| Connectivity | USB Type-C, Wi-Fi, Bluetooth, Hotspot |
| Power | 5 V DC / 5600 mAh Li-ion Battery (12 h continuous operation) |
| Dimensions | 180 × 80 × 70 mm |
| Weight | 700 g |
| Compliance | GB/T 13200–1991, ISO 7027:2016 (Nephelometric Method) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | IN-WH2 |
| Temperature Range | Ambient to 250 °C (digital display) |
| Pressure Range | Not specified in base data |
| Microwave Power | ≤900 W (0–900 W continuous automatic frequency-variable control) |
| Magnetron Frequency | 2450 MHz ± 50 Hz |
| Stirring Method | Magnetic stirring |
| Reaction Vessel Capacity | 100–500 mL |
| Input Power | 1350 W |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±1 °C (±0.5 °C under steady-state conditions) |
| Stirring Speed | 0–2000 rpm (digital display) |
| Internal Cavity Dimensions | 352 × 325 × 202 mm (L×W×H) |
| Overall Dimensions | 500 × 420 × 400 mm (L×W×H) |
| Communication Interface | RS485 |
| Interior Material | Cold-rolled steel with black nano-silver anti-corrosion coating |
| Safety Features | Overcurrent protection, magnetron overheat protection, interlocked door switch (power cutoff upon opening) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | IN-SS11 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Parameters | pH, Dissolved Oxygen (DO), Ammonia-Nitrogen (NH₃-N), Nitrite (NO₂⁻), Total Alkalinity, Hydrogen Sulfide (H₂S), Salinity, Phosphate (PO₄³⁻), Total Hardness, Water Temperature, Residual Chlorine |
| Optical System | Imported Cold Light Source |
| Wavelength Range | 340–800 nm |
| Detection Method | Photometric Colorimetry |
| Display | 3.5-inch Color LCD |
| Operating System | Android-based Embedded OS |
| Data Storage Capacity | >80,000 Records |
| Connectivity | USB Type-C, Wi-Fi, Bluetooth |
| Battery | 5600 mAh Li-ion |
| Continuous Operation Time | ≥12 h |
| Operating Environment | 0–50 °C, 0–90% RH |
| Optical Stability | <0.5% |
| Absorbance Sensitivity | 0.001 AU |
| Dimensions | 180 × 80 × 65 mm |
| Weight | 700 g |
| Language Support | English / Simplified Chinese |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | IN-Y500 |
| Price | USD 11,400 (FOB Qingdao) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-XJ12 |
| Heating Block Material | High-Purity Graphite |
| Number of Digestion Wells | 12 (4×3 array) |
| Well Diameter | 30 mm |
| Well Depth | 60 mm |
| Temperature Range | Ambient to 450 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Control | PID-based, 1–5 programmable ramp segments |
| Display | 5-inch color capacitive touchscreen (Android OS) |
| Power Supply | AC 220 V, 50 ±1 Hz |
| Rated Power | 1620 W |
| Dimensions (W×D×H) | 477 × 415 × 168 mm |
| Weight | 17.9 kg |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automated Colony Counter |
| Sample Type | Standard Petri Dishes (90–110 mm diameter), 3M Petrifilm™, Compact Dry™, RIDA™ Filter Membranes, Fluorescent & Non-fluorescent Microbial Colonies |
| Imaging System | Sealed Light-Tight Dark Chamber with Stray-Light Elimination |
| Illumination | Dual-Independent Adjustable Top/Bottom LED Light Sources |
| UV Modules | 254 nm (sterilization & mutagenesis), 366 nm (fluorescence excitation for *E. coli*, GFP, etc.) |
| Camera | 16 MP Full-Color CMOS Sensor |
| Minimum Detectable Colony Size | 0.1 mm |
| Counting Accuracy | ≤ ±10% |
| Display | 15.6″ Touchscreen (1920 × 1080), Windows 10 64-bit OS, 256 GB Internal Storage |
| Software | Integrated Colony Recognition Engine with Multi-Mode Segmentation Algorithms |
| Compliance | Supports GLP-compliant audit trails, user-level access control, immutable PDF reporting, bilingual (EN/CN) UI |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LAW. |
| Automation Level | Fully Automatic |
| Measurement Range | Fat 0.01–25% (±0.06%), Protein 2–15% (±0.15%), Lactose 0.01–20% (±0.2%), Non-Fat Solids 3–40% (±0.15%), Density 1000–1160 kg/m³ (±0.3 kg/m³), Water Adulteration 0–70% (±3%), Temperature 5–40 °C (±1 °C), Freezing Point −0.400 to −0.700 °C (±0.005 °C), Ash Content 0.4–4% (±0.05%) |
| Sample Throughput | Up to 30 samples/hour (typical) |
| Interface | Capacitive Touchscreen (7-inch, 1280×800) |
| Calibration | Onboard multi-point calibration with remote validation support |
| Data Storage | Internal SSD (64 GB) + USB export + optional cloud sync |
| Compliance | Designed per ISO 9001 manufacturing standards |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | IN-SS |
| Instrument Type | Portable |
| Detection Range | 1–600 mg/L |
| Standard Compliance | GB 13200-91 |
| Wavelength Range | 340–800 nm |
| Measurement Principle | Photometric Colorimetry |
| Repeatability | <0.5% |
| Stability | <0.5% |
| Wavelength Selection | Automatic |
| Operating System | Android-based UI |
| Display | 3.5-inch color LCD touchscreen |
| Absorbance Sensitivity | 0.001 AU |
| Environmental Operating Conditions | 0–50 °C, 0–90% RH (non-condensing) |
| Data Storage Capacity | >80,000 records |
| Connectivity | USB Type-C, Wi-Fi, Bluetooth, Mobile Hotspot |
| Battery | 5600 mAh rechargeable Li-ion |
| Continuous Operation Time | Up to 8 hours |
| Power Supply | 5 V DC |
| Dimensions | 180 × 80 × 70 mm |
| Weight | 700 g |
| Light Source | Imported cold-light LED (rated lifetime ≥100,000 h) |
| Dual Power Mode | AC adapter & internal battery |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | IN-LeafClear |
| Price | USD 67,000 (FOB) |
| Camera Resolution | 1608 × 1104 |
| Pixel Size | 9 µm × 9 µm |
| Frame Rate | 100 fps |
| Bit Depth | 12-bit |
| Interface | USB 3.0 |
| Lens Focal Length | 12 mm (adjustable) |
| Max Aperture | F/2.8 (adjustable) |
| HFOV | 62.11° |
| VFOV | 44.83° |
| Max Imaging Area | 50 cm × 35 cm |
| Excitation Wavelength | 450 nm (blue LED) |
| Actinic Light | 630 nm (red LED) |
| Far-Red Light | 730 nm |
| Actinic Irradiance Range | 90–1440 µmol/(m²·s) |
| OJIP Duration | 0.1–1.0 s |
| PAM Dark Adaptation | 0–3600 s |
| Saturation Pulse Intensity | 15–100% (450 nm) |
| Fluorescence Dynamic Range | 0–4095 (12-bit) |
| SNR | >100:1 |
| Repeatability (CV) | <3% |
| Linearity (R²) | >0.999 |
| Minimum Sampling Interval | 10 ms (OJIP), 100 ms (PAM) |
| Spatial Resolution | ~0.3 mm/pixel (at 50 cm × 35 cm FOV) |
| Brand | COMECAUSE |
|---|---|
| Model | IN-ZS300 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Principle | Multi-Wavelength Reflectance-Based Colorimetry (4-channel fixed optical path) |
| Target Elements | Pb, As, Cr, Cd, Hg, Ni, Al, F, Ti, Se, Fe, Zn, Mn, Cu |
| Sample Matrix | Soil, Fertilizer, Food, Vegetables, Fruits |
| Analysis Time (Full Workflow) | ~60 min for Pb/As/Cr/Cd/Hg panel (incl. extraction & reagent prep) |
| Power Supply | AC 220 V ±10% / DC 12 V + 5 V (4800 mAh Li-ion battery, ≥10 h runtime) |
| Display | 7.0" TFT-LCD, 1024×600 resolution, dual-language UI (EN/CN) |
| Data Connectivity | Wi-Fi, USB ×2, thermal printer, GPS geotagging, cloud upload to dedicated agricultural data platform |
| Compliance | IP65 ingress protection, CE-marked electrical safety, software registered under China Copyright Protection Center (No. 2023SRXXXXXX) |
| Operating System | Android 5.1, quad-core CPU ≥1.8 GHz, 16 GB internal storage |
| Optical Sources | 4 stabilized LEDs (680±2 nm red, 420±2 nm blue, 510±2 nm green, 590±4 nm orange), >100,000 h lifetime |
| Photometric Stability | Drift ≤0.3% (transmittance) within 1 h |
| Dimensions | 470 × 340 × 210 mm (L×W×H) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | IN-Q12 |
| Detection Limit | 1 mg/kg |
| Detection Range | 0–100 mg/kg |
| Absorbance Range | 0.000–4.000 A |
| Repeatability | ±0.1% (A) |
| Repeatability Error | ≤0.003 A |
| Photometric Drift | ±0.002 A (3 min) |
| Absorbance Accuracy | ±2.0% |
| Linearity Error | ±1.0% |
| Detection Channels | ≥12 |
| Processor | ARM Cortex-A7 RK3288 (4-core, 1.88 GHz) |
| Display | 7-inch capacitive touchscreen |
| Power Supply | DC 12 V (compatible with vehicle power & optional 6 Ah rechargeable Li-ion battery) |
| Connectivity | Wi-Fi, Ethernet, GPRS, USB 2.0 |
| Data Output | Thermal printer (embedded), QR code generation, cloud upload via regulatory platform |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-KZ04 |
| Instrument Category | Seed Morphometric & Weight Analysis System |
| Imaging Resolution | 1600 dpi × 1600 dpi (A3-format UV-enhanced color scanner M1 Plus) |
| Sample Throughput | 10 whole ears |
| Counting Speed | 1500–4000 kernels/min |
| Counting Accuracy | ≤ ±0.5% (manual verification enables 100% correction) |
| Morphometric Accuracy | ≤ ±0.3% |
| Thousand-Kernel Weight (TKW) Precision | ≤ ±0.5% |
| Color Representation | RGB-based quantitative seed color indexing |
| Software Platform | Windows 10 or later |
| Data Export | Auto-generated Excel (.xlsx), customizable save path, append-mode support |
| Cloud Integration | Device-ID-bound encrypted cloud storage with remote access |
| Interface | RS232-connected precision balance, USB imaging interface |
| Language Support | Switchable bilingual UI (English/Chinese) |
| Brand | COMECAUSE |
|---|---|
| Model | IN-ZT20 |
| Origin | Shandong, China |
| Manufacturer | COMECAUSE (OEM/ODM Producer) |
| Category | Plant Physiology & Ecology Instruments / Porometers |
| Measurement Principle | Open-path diffusion-based real-time gas exchange analysis |
| Temperature Range (Leaf Chamber) | –20–80 °C |
| Leaf Temperature Sensor | Pt100 platinum resistance thermometer, ±0.2 °C accuracy, 0.1 °C resolution |
| Air Humidity Sensor | Swiss-made digital hygrometer, 0–85% RH, ±1% RH accuracy, 0.1% RH resolution |
| PAR Sensor | Calibrated silicon photodiode with spectral correction filter (400–700 nm), 0–3000 μmol·m⁻²·s⁻¹, <1 μmol·m⁻²·s⁻¹ uncertainty |
| Flow Control | Precision micro-electronic mass flow controller, adjustable 0.2–1.0 L·min⁻¹, 0.0001 L·min⁻¹ resolution, ±0.005 L·min⁻¹ zero drift |
| Transpiration Rate (Tr) | mmol H₂O·m⁻²·s⁻¹ (±1–5% typical uncertainty) |
| Stomatal Conductance (Gs) | mol H₂O·m⁻²·s⁻¹ (±5–10% typical uncertainty) |
| Stomatal Resistance (Rs) | s·m⁻¹ |
| Display | 3.5″ TFT color LCD, 800×480 pixels |
| Data Storage | 16 GB internal flash memory (expandable to 32 GB) |
| Power | Rechargeable 8.4 V DC Li-ion battery, ≥20 h continuous operation (no external light source) |
| Dimensions | 260 × 260 × 130 mm |
| Weight | 3.25 kg (main unit only) |
| Brand | COMECAUSE |
|---|---|
| Model | JSD-3 |
| Type | Handheld Soil Hardness Tester |
| Measurement Range | 0–100 kg |
| Accuracy | ±0.1 %FS |
| Operating Temperature | −20 to +70 °C |
| IP Rating | IP66 |
| Probe Diameter | 12 mm |
| Probe Length | 300 mm |
| Sensor Dimensions | Ø29 × 39.5 mm |
| Power Supply | DC 5 V / 2 A |
| Battery Capacity | 6000 mAh (10 h standby) |
| Data Storage | 5 million records |
| Connectivity | Wi-Fi, GPS, USB-C, GPRS (optional) |
| Display | 3.5″ color touchscreen |
| Weight | 3.2 kg |
| Enclosure Material | Aluminum alloy case |
| Probe Material | Stainless steel |
| Brand | COMECAUSE |
|---|---|
| Model | QX6530P |
| ORP Range | −2000 to +2000 mV, Resolution: 0.1 mV, Accuracy: ±10 mV |
| pH Range | 0–14, Resolution: 0.1, Accuracy: ±0.05 |
| Temperature Range | 5–60 °C, Resolution: 0.1 °C, Accuracy: ±1 °C |
| Power Supply | DC 5 V / 2 A |
| Rated Power | 3 W |
| Battery Capacity | 6000 mAh |
| IP Rating | IP65 |
| Dimensions (L×W×H) | 500 × 380 × 180 mm |
| Weight | 4.1 kg |
| Brand | COMECAUSE |
|---|---|
| Model | IN-QX6530PS |
| Origin | Shandong, China |
| Manufacturer | COMECAUSE (OEM/ODM Producer) |
| ORP Range | −2000 to +2000 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±10 mV |
| pH Range | 0–14 |
| pH Resolution | 0.1 |
| pH Accuracy | ±0.05 |
| Temperature Range | 5–60 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±1 °C |
| Power Supply | DC 5 V / 2 A |
| Battery Capacity | 6000 mAh |
| IP Rating | IP65 |
| Display | 3.5″ color capacitive touchscreen |
| Data Storage | 5 million records |
| Connectivity | Wi-Fi, USB Type-C |
| Compliance | HJ 746–2015, SL 94–1994 |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | IN-SL20 |
| Instrument Category | Sample-Dividing Seed Counter |
| Application Scope | Corn, rice, wheat, soybean, sesame, vegetable seeds, micro-components, pearls, pharmaceutical tablets |
| Counting Accuracy | ±2‰ |
| Throughput | 1,000–2,000 seeds/min |
| Seed Length Range | 0.5–23 mm |
| Sample Capacity per Vial | 1–9999 seeds |
| Preset Stop Range | 1–9999 (0000 = continuous mode) |
| Counting Disc Speed | 0–99 (adjustable) |
| Sensitivity Adjustment | 0–10 (user-defined) |
| Vial Quantity | 12 pcs |
| Vial Dimensions | Ø60 × 80 mm (H) |
| Main Unit Dimensions & Weight | 580(W) × 390(D) × 336(H) mm, 24 kg |
| Receiving Unit Dimensions & Weight | 360(W) × 390(D) × 197(H) mm, 12 kg |
| Continuous Operation Time | ≥8 h |
| Noise Level | ≤80 dB(A) |
| Operating Environment | –10°C to +50°C |
| Power Supply | AC 220 V, 50 Hz (optional export voltages: 100/110/200/240 V, 50/60 Hz) |
| Data Storage | Local history with timestamped records (variety name, count, weight, 1,000-seed weight, duration, test time) |
| Data Export | USB flash drive |
| Display | 7-inch color touchscreen (optional 10.1-inch upgrade) |
| UI Language | Switchable Chinese/English |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Microwave Synthesizer |
| Model | IN-WH8 |
| Temperature Range | Ambient to 250 °C (high-temperature customization available) |
| Pressure Range | Not specified in source data |
| Microwave Output Power | ≤2000 W (0–1800 W continuous automatic frequency-variable control) |
| Magnetron Frequency | 2450 MHz ±50 Hz |
| Stirring Method | Magnetic stirring |
| Reaction Vessel Capacity | 50–500 mL |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±1 °C |
| Programmable Segments | 30 |
| Stirring Speed Range | 0–2000 rpm (digital display) |
| Maximum Runtime per Segment | 3200 min |
| Cavity Dimensions | 325 × 325 × 202 mm (L×W×H) |
| External Dimensions | 500 × 420 × 555 mm (L×W×H) |
| Display | 7-inch capacitive touchscreen LCD |
| Safety Features | Empty-cavity detection, low-dielectric material auto-shutdown, real-time fault alarm |
| Data Interface | USB port for mouse/U-disk connection, temperature curve logging, and parameter export |
| Brand | COMECAUSE |
|---|---|
| Model | QX6530P |
| Measurement Range (ORP) | −2000 to +2000 mV |
| Resolution (ORP) | 0.1 mV |
| Accuracy (ORP) | ±10 mV |
| pH Range | 0–14 |
| pH Resolution | 0.1 |
| pH Accuracy | ±0.05 |
| Temperature Range | 5–60 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±1 °C |
| Power Supply | DC 5 V / 2 A |
| Battery Capacity | 6000 mAh |
| Data Storage | 5,000,000 records |
| Ingress Protection | IP65 |
| Weight | 4.1 kg |
| Dimensions (L×W×H) | 500 × 380 × 180 mm |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | IN-FT300 |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 20–300 W |
| Sample Volume Capacity | 0.1–300 mL (with interchangeable titanium alloy probes) |
| Pulse Control Resolution | 0.1 s (on/off/total time) |
| Temperature Monitoring Range | 0–99.9 °C (contact-type sensor) |
| Display | 10.1″ HD capacitive touchscreen |
| Probe Material | TC4 titanium alloy |
| Transducer Housing | Aerospace-grade magnesium-aluminum alloy |
| Data Storage | 256 programmable protocols |
| Compliance | CE-marked design principles |