| Brand | Shanda |
|---|---|
| Model | SD-RXS |
| Origin | Shandong, China |
| Measurement Principle | Compression-based Gravimetric Method (NY/T 821–2004) |
| Force Range | 0–3000 N |
| Resolution | 0.1 N |
| Accuracy | ±1% FS |
| Compression Speed | 1–300 mm/min |
| Dwell Time | 1–3600 s |
| Deformation Range | 1–70 mm |
| Platen Diameter | 110 mm |
| Parallelism | <0.05 mm |
| Dimensions | 450 × 450 × 680 mm |
| Weight | ~45 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Shanda |
|---|---|
| Model | SD-2TA |
| Type | Manual Hydraulic Powder Press |
| Maximum Pressure | 2 Ton (25 MPa) |
| Piston Diameter | Ø32 mm |
| Max Piston Stroke | <30 mm |
| Pressure Gauge | Analog Dual-Scale (MPa & Ton), Accuracy: ±1 MPa |
| Pressure Stability | ≤1 MPa/10 min |
| Worktable Diameter | Ø70 mm |
| Working Space | 90 × 120 mm |
| Overall Dimensions | 210 × 170 × 370 mm |
| Net Weight | ~11 kg |
| Compliance | Designed for GLP-aligned lab environments |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FERRITE-CHECK 140 |
| Price | USD 4,200 (approx.) |
| Measurement Range | 1–100 Fe% / 1–140 Ferrite Number (FN) |
| Accuracy | ±<5% of reading |
| Operating Temperature | 0–50 °C |
| Calibration Standards | Three NIST-traceable ferrite reference standards |
| Power Supply | Rechargeable lithium-ion battery |
| Compliance | DIN EN ISO 8249:2018 |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Model | SD-HQMG |
| Price | USD 1,390 (FOB) |
| Function Type | Multi-analyte Detection Platform |
| Sample Scope | Universal for Cereals, Oilseeds, Feed Matrices, and Processed Food Commodities |
| Main Controller | ARM Cortex-A7 |
| Detection Channels | ≥12 independent optical channels |
| Display | 10.1-inch HD vertical capacitive touchscreen (1280×800) |
| Communication Interfaces | Integrated Wi-Fi (802.11 b/g/n), RJ45 Ethernet port, USB 2.0 host/device |
| Power Supply | DC 12 V — compatible with vehicle power outlets |
| Data Storage | Internal eMMC (16 GB) + USB flash drive support (FAT32/exFAT) |
| Dimensions (W×D×H) | 430 × 350 × 190 mm |
| Net Weight | 5.1 kg |
| Light Source | Precision imported quad-wavelength cold LED source (450 nm, 520 nm, 590 nm, 630 nm) |
| Processor | Rockchip RK3288 (ARM Cortex-A17 quad-core, 1.8 GHz) |
| Brand | Shanda |
|---|---|
| Model | SD-GCT-28A |
| Sample Capacity | 28 positions |
| Power Supply | 220–230 V, 50 Hz |
| Operating Temperature Range | 5–40 °C |
| Relative Humidity | 10–85% |
| Temperature Control Accuracy | 25 °C ± 2 °C |
| Software | PC-based workstation software with real-time hardware monitoring, error code display, Excel export, color-coded batch labeling, and historical data retrieval |
| Optional Accessories | Rice sample preparation mill, dedicated PC, water-cooling unit |
| Brand | Shanda Instruments |
|---|---|
| Model | SD-BQ12T |
| Origin | Shandong, China |
| Instrument Type | Benchtop Integrated Spectrophotometric Analyzer for MDA Quantification in Edible Animal Fats |
| Detection Principle | Colorimetric Assay (Thiobarbituric Acid Reactive Substances, TBARS) |
| Display | 10.1-inch Vertical Touchscreen (Android OS, ARM Cortex-A7 RK3288 Quad-Core @ 1.88 GHz) |
| Optical System | Four-Wavelength Cold Light Source per Channel (410 / 520 / 590 / 630 nm), Patented Optical Path Switching Enabling Up to 64 Wavelengths |
| Detection Channels | ≥12 Simultaneous Channels with Precision Rotating Cuvette Holder |
| Calibration | One-Touch Auto-Calibration with Persistent SP Storage of Light Source Parameters |
| Data Storage | ≥200,000 Records, USB Exportable as Excel Files, Password-Protected Access |
| Connectivity | Dual USB, RJ45 Ethernet, Bluetooth 4.2, 4G APN Module, Wi-Fi |
| Software Expandability | Pre-Configured for 60+ Food Safety Assays |
| Compliance Framework | Designed for Routine Use in GLP-Compliant Food Quality Control Environments |
| Brand | Shanda |
|---|---|
| Model | SD-PE-T |
| Type | Electronic Farinograph |
| Power Supply | 220 V AC, 50 Hz |
| Motor Power | 300 W |
| Rotational Speed Range | 2–200 ±1 rpm (adjustable, real-time display) |
| Speed Ratio (Fast/Slow Blades) | 1.5:1 |
| Torque Measurement Range | 0–20 N·m |
| Torque Sensor Accuracy | ≤0.3% FS |
| Bowl Capacity | 300 g |
| Torque Unit Calibration | (9.8 ± 0.2) mN·m per Farinograph Unit (FU) |
| Measuring Range | 0–2000 FU |
| Water Addition Accuracy | ±0.2 mL (for 300 g dough) |
| Water Bath Pressure | ≤340 mbar |
| Water Circulation Flow Rate | 15 L/min (auto-fill enabled) |
| Dough Temperature Control | 30 ± 0.2 °C (PID-controlled water jacket) |
| Temperature Setting Range (Incubation Chamber) | 20–50 °C |
| Chamber Temperature Stability | ±0.2 °C |
| Chamber Power | 1200 W |
| Chamber Display | 5-inch embedded LCD touch screen |
| Safety Features | Overload protection (bowl), mechanical/electrical interlock (mixer), real-time heating element monitoring, automatic alarm on anomaly |
| Material | Imported stainless steel (bowl & blades), corrosion-resistant surface-treated structural components |
| Compliance Standards | ICC 115/1, AACC 54-21, ISO 5530-1, GB/T 14614 |
| Data Handling | Multi-file curve overlay (unlimited), custom color/name assignment, cross-brand farinogram import (legacy formats), real-time interruption & interim calculation, encrypted storage, export to CSV/Excel, GLP-compliant audit trail (via Smart Pbox integration) |
| Software | Windows 7/10 native, perpetual license, free lifetime updates |
| Service | Annual certified standard-sample calibration (with CNAS-accredited reference material certificate), two free post-warranty calibration & maintenance visits (Years 2–3), third-party performance evaluation report issued by national metrology institute |
| Connectivity | Real-time multi-terminal data viewing (requires Smart Pbox gateway) |
| Brand | Shanda Instruments |
|---|---|
| Model | FERRITE-CHECK 240 |
| Measurement Range | 0.2–100 Fe% / 0.2–140 FN |
| Accuracy | <5% |
| Operating Temperature | 0–50 °C |
| Calibration Standards | 3 certified ferrite reference blocks |
| Power Supply | 3 × 1.5 V AA batteries or USB-C external power |
| Compliance | DIN EN ISO 8249 |
| Display | 320 × 480 pixel color LCD touchscreen |
| Data Storage | 10,000 measurements with statistical analysis (min/max/mean/std dev) |
| Connectivity | Bluetooth 5.0 (Android/iOS/Windows compatible) |
| Software | Lima Connect (free PC/mobile application) |
| Dimensions | 150 × 85 × 35 mm |
| Weight | 320 g (including batteries) |
| Minimum Test Area | Ø 2 mm |
| Resolution | 0.1 Fe% / 0.1 FN |
| Battery Life | ~25 h continuous operation |
| Brand | Shanda |
|---|---|
| Model | SD-FSX |
| Origin | Shandong, China |
| Category | Rubber & Plastic Industry–Specific Instrument |
| Compliance | GB/T 6030–2006 |
| Imaging Sensor | 5 MP CMOS |
| Resolution Options | 640×480, 1024×768, 1280×1024, 2592×1944 |
| Interface | USB 2.0 |
| Calibration | Integrated micrometer scale with pixel-to-µm mapping |
| Output Formats | PDF, PNG/JPEG, Excel (.xlsx) |
| Software Compatibility | Windows XP/7/10 (32/64-bit) |
| Image Segmentation Modes | Automated thresholding + manual ROI selection |
| Standard Reference Libraries | ISO-aligned carbon black dispersion image library + user-customizable library |
| Data Export | Particle count, equivalent circular diameter (µm), projected area (µm²), grayscale histogram, particle size distribution curve, dispersion rating (0–10 scale per GB/T 6030) |
| Brand | Shanda |
|---|---|
| Model | SD-Z08P |
| Origin | Shandong, China |
| Regulatory Approval | Approved by Ministry of Agriculture and Rural Affairs (MARA), P.R. China |
| Detection Principle | Real-Time Fluorescent Quantitative Polymerase Chain Reaction (qPCR) |
| Target Analyte | African Swine Fever Virus (ASFV) Genomic DNA |
| Compatible Assays | MARA-registered ASFV fluorescent qPCR kits (e.g., SD-ASF-KIT series) |
| Operational Modes | Laboratory-based and field-deployable (battery-supported operation optional) |
| Throughput | 8 samples per run |
| Thermal Cycling Range | 4–105 °C |
| Fluorescence Channels | 4-channel excitation/emission detection (FAM, HEX/VIC, ROX, CY5) |
| Data Output | Ct values, amplification curves, qualitative/quantitative reports compliant with MARA diagnostic guidelines |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Model | SD-CL9 |
| Measurement Principle | Coulometric Titration (per GB/T 214–2007) |
| Sample Types | Coal, Coke, Activated Carbon, Petroleum Coke |
| Temperature Control | Microprocessor-regulated High-Temperature Furnace (up to 1150 °C) |
| Electrolytic Cell | Integrated Dual-Platinum Electrode Cell |
| Display | 7-inch TFT LCD Touch Interface |
| Power Supply | AC (220 ± 22) V, 50 Hz |
| Max Power Consumption | ≤3 kW |
| Safety Features | Automatic Silicon Carbide Tube Protection, Overcurrent Protection, Real-time Temperature Compensation |
| Data Management | Non-volatile Memory Storage, USB Export, Print Support (via RS232 or USB thermal printer) |
| Compliance | Designed to meet requirements of GB/T 214–2007, ASTM D3177, ISO 4293, and supports GLP-compliant audit trails when paired with optional PC software |