- All
- Favorite
- Popular
- Most rated
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | BHC-1300IIA2 |
| Cabinet Class | NSF/EN 12469 Class II, Type A2 |
| External Dimensions (L×W×H) | 1500 × 640 × 1950 mm |
| Internal Work Area (L×W×H) | 1300 × 580 × 680 mm |
| HEPA Filter Efficiency | ≥99.99% @ 0.3 µm (tested per ISO 14644-3 & IEST-RP-CC001.3) |
| Inflow Velocity | 0.35 ± 0.025 m/s |
| Downflow Velocity | 0.26–0.27 ± 0.025 m/s |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V / 50 Hz |
| Max. Power Consumption | 0.9 kW |
| Weight | <250 kg |
| Filter Configuration | Single integrated HEPA filter (1295 × 600 × 38 mm), liquid-sealed, pre-filtered intake |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | YQX-II |
| Instrument Type | Manual Anaerobic Incubator with Microaerophilic Capability |
| Oxygen Concentration Range | ≤1% (Anaerobic) / Adjustable 2–10% (Microaerophilic) |
| Temperature Control Range | Ambient +3°C to 50°C |
| Temperature Uniformity | ±1°C |
| Temperature Stability | ±0.5°C |
| Operating Chamber Dimensions | 800 × 550 × 650 mm (W×D×H) |
| Gas Supply Options | Single-gas (premixed 10% H₂ + 10% CO₂ + 80% N₂) or Dual-gas (pure N₂ + premixed gas) |
| Deoxygenation Time (Operation Chamber) | <60 min |
| Anaerobic Maintenance Duration (without gas replenishment) | ≥12 h |
| Power Supply | 220 V, 50 Hz / 1000 W |
| UV Sterilization Lamp | Integrated |
| Catalytic Oxygen Scrubber | Built-in |
| Casters with Locking Brakes | Yes |
| Compliance | Designed for ISO 13485-aligned lab workflows |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | PRX-1200C |
| Type | Fully Automatic Programmable Incubator |
| Capacity | 12000 L |
| Temperature Range | 0–50 °C |
| Temperature Uniformity | ±1.5 °C |
| Humidity Range | 50–95 %RH |
| Humidity Uniformity | ±5–8 %RH |
| Illumination Intensity | 0–22000 lx |
| External Dimensions | 1500 × 860 × 1880 mm |
| Brand | Chuanyu Instruments (Shanghai Chuanyu Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CHDJ-II (2-Layer) |
| Instrument Type | Stackable Constant-Temperature Shaker |
| Timer Range | 0–120 min (standard) |
| optional extended timer | 0–9999 min |
| Oscillation Frequency | 0–280 rpm |
| Oscillation Amplitude | 26 mm (Φ) |
| Temperature Range | 4–60 °C |
| Temperature Accuracy | ≤ ±0.5 °C (typical) |
| Temperature Uniformity | ≤ ±0.5 °C across chamber |
| Number of Shaking Platforms | 2 |
| Platform Dimensions | 440 × 350 mm |
| Inner Chamber Dimensions (per layer) | 540 × 450 × 450 mm |
| Overall Dimensions (2-layer) | 640 × 700 × 1400 mm |
| Power Supply | 220 V, 50 Hz |
| Drive System | Brushless DC motor with eccentric cam mechanism |
| Display | 5-inch color LCD touchscreen |
| Control Logic | PID auto-tuning temperature controller with PT100 sensor |
| Security | Three-level password management |
| Defrost Mode | Five-stage automatic defrost |
| Power Recovery Modes | Resume, Hold, or Restart |
| Door Access | Side-opening design, tool-free operation |
| Optional Features | UV germicidal lamp, internal LED illumination, 10-segment programmable schedule (temp + speed), data logging with USB export (CSV), RS-485 interface (optional) |
| Brand | Chuanyu Yiqi |
|---|---|
| Origin | Shanghai, China |
| Model | MJX-250 |
| Capacity | 250 L |
| Temperature Range | 0–60 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Control | Optional (50–95% RH, ±5–8% RH fluctuation) |
| Construction | Mirror-finish stainless steel chamber, electrostatically coated exterior, double-glazed magnetic door seal |
| Cooling System | Hermetically sealed compressor with eco-friendly refrigerant (R134a or equivalent) |
| Control System | LCD PID controller with real-time setpoint/actual value display, programmable timer (0–999 h/min), auto-restart after power failure, over-temperature alarm, temperature calibration function, and UV sterilization lamp |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SPX-350B |
| Temperature Range | 0–60 °C |
| Internal Dimensions (W×D×H) | 500 × 560 × 1280 mm |
| External Dimensions (W×D×H) | 600 × 670 × 1918 mm |
| Temperature Uniformity | ±1 °C |
| Temperature Stability | ±0.5 °C |
| Control System | PID-controlled digital microprocessor with dual LED display (set & actual temperature) |
| Sensor | PT100 platinum resistance thermometer |
| Refrigeration | Eco-friendly R134a compressor-based cooling module with high/low pressure protection and delayed start |
| Air Circulation | Forced convection via stainless steel duct system |
| Interior Material | Mirror-finish 304 stainless steel chamber with adjustable, removable shelves |
| Viewing Window | Large-angle tempered glass observation window with interior LED lighting |
| Safety Features | Over-temperature alarm, timer function, auto cut-off protection |
| Brand | Chuanyu |
|---|---|
| Origin | Shanghai, China |
| Model | ZDX-100-CO₂ |
| Instrument Type | Air-jacketed CO₂ incubated shaker |
| CO₂ Detection | Infrared (IR) sensor |
| Temperature Range & Accuracy | RT + 5°C to 50°C, ±0.5°C |
| Temperature Uniformity | ±1.0°C |
| CO₂ Concentration Range & Accuracy | 0–20% v/v, ±0.5% |
| Humidity Range & Accuracy | 40–95% RH |
| Capacity | 100 L |
| External Dimensions (W×D×H) | 500 × 500 × 400 mm |
| Tray Size | 200 × 200 mm |
| Speed Range | 40–300 rpm |
| Orbit Diameter | ≥20 mm |
| Sterilization | Built-in UV lamp |
| Control Interface | Microprocessor-based LCD with menu-driven operation |
| Power Backup Function | Power-loss memory and automatic time compensation |
| Safety Features | Over-temperature alarm, real-time CO₂ monitoring, insulated tempered-glass door |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | HWS-450BC |
| Heating Method | Air-jacketed heating |
| Cooling Method | Compressor-based refrigeration |
| Humidification System | External ultrasonic humidifier tank |
| Temperature Range (with humidity) | 10–50 °C |
| Temperature Range (dry operation) | 0–50 °C |
| Temperature Fluctuation | ±0.5–1 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | 50–95 %RH |
| Humidity Accuracy | ±5–8 %RH |
| Capacity | 450 L |
| Internal Dimensions | 600 × 600 × 1250 mm |
| Overall Dimensions | 700 × 790 × 1850 mm |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | CHZDFY-8 |
| Dispensing Range | 1–2000 µL |
| Dispensing Accuracy | ≤1.5% CV at 100 µL (96-well plate) |
| Throughput | 96-well microplates |
| Dispensing Modes | Full-plate or user-defined column selection |
| Dispensing Principle | Peristaltic pump-based non-contact delivery |
| Plate Height Adjustment | Motorized auto-adjustment |
| Channel Configuration | 8-channel parallel dispensing |
| Display | 7-inch color TFT touchscreen interface |
| Integrated Functions | Plate shaking, pre-wetting, liquid retraction, carriage homing, and automated waste aspiration |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 420 × 380 mm |
| Weight | 18.5 kg |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | CHW-300BS |
| Instrument Type | Semi-Automatic Microbial Limit Testing System |
| Throughput | 3 independent filtration channels |
| Filter Membrane Diameter | Φ47 mm / Φ50 mm |
| Effective Filtration Area | 40 mm diameter |
| Filter Cup Capacity | 150 mL (250 mL optional) |
| Filtration Rate | 100 mL per 15 s |
| Vacuum Source | Built-in进口 diaphragm liquid-handling pump (oil-free) |
| Sterilization Methods | Autoclavable filtration heads |
| Display | LCD interface showing real-time time/date and pump status |
| Compliance | Designed for USP <61>, <62>, EP 2.6.12, and ISO 8573-7 compliant microbial enumeration workflows |