Empowering Scientific Discovery

Shanghai Farun Scientific Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPHMP / PHMP-4
Temperature RangeAmbient +5 °C to 60 °C
Temperature Uniformity±0.5 °C
Temperature Stability±0.1 °C
Oscillation Speed25–1200 rpm
Speed Resolution10 rpm
Orbital Radius2 mm
Timer Range1 min to 96 h (1-min increments)
Operating Environment4–40 °C
Input Voltage120 V or 230 V AC, 50/60 Hz
DC Output12 V DC, 5 A
Microplate CapacityPHMP: 2 plates
PHMP-44 plates
Heating Rate (RT to 37 °C)15–20 min
DisplayDual-line, 16-character LCD
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDB-4S
PriceUpon Request
Temperature Setting Range+25 °C to +100 °C
Temperature Control RangeAmbient +5 °C to +100 °C
Stability @37 °C±0.03 °C
Uniformity @37 °C±0.12 °C
Setpoint Resolution0.1 °C
DisplayDual-line LCD
Heating Time (25 °C → 37 °C)4 min
Heating Time (25 °C → 60 °C)10 min
Heating Time (25 °C → 100 °C)40 min
Capacity32 × 0.2 mL microtubes or 4 × 0.2 mL PCR strip tubes
Timer Range1–96 h
Input Voltage12 V DC
Input Current0.85 A
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPSC96
Temperature Range0–100 °C
Temperature Accuracy±1 °C
Heating Time to 100 °C≤1 min
Block Configuration96-well compatible aluminum heating block
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPRS-14
Temperature Range0–100 °C
Temperature Accuracy±1 °C
Heating Time to 100 °C≤1 min
Platform MotionOrbital, 25 mm Diameter
Speed Range100–1,200 rpm
Speed Accuracy±2 rpm
Platform Size260 × 240 mm
Max Load Capacity3 kg
Power Supply100–240 VAC, 50/60 Hz
Safety CertificationsCE, RoHS, IEC 61010-1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrant
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelQB-ACC
Temperature RangeAmbient +10°C to 150°C
Temperature Accuracy±0.3°C at 37°C, ±0.5°C across full range
Heating Time≤12 min (from 25°C to 100°C)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrant
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPRS-10
Temperature RangeAmbient to 100 °C
Temperature Accuracy±1 °C
Heating Time to 100 °C≤1 min
Platform Size290 × 290 mm
Orbit Diameter20 mm
Speed Range50–300 rpm
Speed Accuracy±2 rpm
Load Capacity3 kg
Power Supply100–240 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUnited Kingdom
Manufacturer TypeDistributor
Origin CategoryImported
ModelBTD
PriceUpon Request
Temperature RangeAmbient +5°C to 100°C
Setpoint Range25°C to 100°C
Temperature Stability @37°C±0.1°C
Temperature Uniformity @37°C±0.2°C
Heating Time (25°C → 100°C)16 min
External Dimensions (W×D×H)210 × 230 × 110 mm
Block Diameter/Depth130 × 45 mm
Power Consumption200 W
Timer Range1 min to 96 h
Over-Temperature ProtectionThermal Cut-Out Fuse
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelDB-10C
PriceUpon Request
Heating Set Range+25 °C to +42 °C
Temperature Control RangeAmbient +5 °C to +42 °C
Stability±0.1 °C
Uniformity±0.3 °C
Resolution0.1 °C
DisplayDual-line LCD
Heating Time (RT → 42 °C)≤15 min
Capacity10 × 10-mm-path cuvettes
Timer Range1–96 h
Power Supply12 V DC, 1 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGrant
OriginUK
ModelQBD1
Temperature RangeAmbient +5°C to 130°C
Temperature Accuracy±0.1°C @ 37°C
Temperature Uniformity (within module)±0.1°C @ 37°C
Set Resolution0.1°C
Heating Time15 min (25°C → 100°C)
Dimensions (W×D×H)230 × 200 × 100 mm
Net Weight2 kg
Power150 W
Voltage120 V or 230 V AC
SafetyOver-temperature cut-off fuse
Programmable3-step temperature/time profile + timer (1–999 min) + extended heating mode (up to 72 h)
CalibrationDual-point (internal/external probe)
AlarmsAdjustable high/low temperature deviation (±0.5°C from setpoint)
DisplayLED, 0.1°C resolution
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0