- All
- Favorite
- Popular
- Most rated
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PHMP / PHMP-4 |
| Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Stability | ±0.1 °C |
| Oscillation Speed | 25–1200 rpm |
| Speed Resolution | 10 rpm |
| Orbital Radius | 2 mm |
| Timer Range | 1 min to 96 h (1-min increments) |
| Operating Environment | 4–40 °C |
| Input Voltage | 120 V or 230 V AC, 50/60 Hz |
| DC Output | 12 V DC, 5 A |
| Microplate Capacity | PHMP: 2 plates |
| PHMP-4 | 4 plates |
| Heating Rate (RT to 37 °C) | 15–20 min |
| Display | Dual-line, 16-character LCD |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | HED |
| Price | Upon Request |
| Temperature Range | 50–260 °C |
| Stability | ±0.25 °C (at 150 °C, per DIN 58966) |
| Uniformity | ±0.2 °C (at 150 °C, per DIN 58966) |
| Display | LED, Resolution 1 °C |
| Timer | 1–9999 min |
| Alarm | High/Low Temperature |
| Heating Power | 1.1 kW (HE10D), 2.2 kW (HE30D) |
| Total Power Consumption | 1.2 kW (HE10D), 2.3 kW (HE30D) |
| Max Flow Rate | 6 L/min (with optional HQ pump) |
| Pump Head Pressure | 1.6 m @ 0 L/min |
| Tubing ID | 7.5 mm |
| Bath Opening | 190×210 mm (HE10D), 350×305 mm (HE30D) |
| Bath Dimensions (L×W×H) | 305×210×185 mm (HE10D), 455×305×240 mm (HE30D) |
| Liquid Depth Range | 100–140 mm (HE10D), 145–190 mm (HE30D) |
| Safety Features | Adjustable Over-Temperature Cut-Out, Float-Switch Level Protection |
| EMC Emission Class | Class A |
| Fluid Compatibility | Silicone Oil (recommended), other high-temperature heat transfer fluids |
| Optional External Circulation Pumps | HQ10 (for HE10D), HQ30 (for HE30D), mountable on insulated lid, for closed-loop systems only |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | SAP5 |
| Bath Capacity | 5 L |
| Temperature Range | Ambient +5 °C to 99 °C |
| Setpoint Range | 10 °C to 99 °C (0.1 °C resolution) |
| Stability at 37 °C (DIN 12876) | ±0.2 °C |
| Control Type | Digital PID |
| Display | 3-digit LED |
| Power Supply | 120 V or 230 V AC |
| Heating Power | 0.375 kW (120 V) / 0.375 kW (230 V) |
| Drain Valve | Yes |
| Over-Temperature Protection | Adjustable Cut-Off |
| CSA Certified | Yes |
| External Dimensions (L×W×D) | 145 × 290 × 115 mm |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GD120 |
| Pricing | Available Upon Request |
| Temperature Range | −15 °C to +120 °C (model-dependent) |
| Stability @37 °C | ±0.02 °C |
| Uniformity @37 °C | ±0.05 °C |
| Set/Display Resolution | 0.1 °C |
| Bath Volume Options | 5 / 12 / 18 / 26 / 38 L |
| Max Flow Rate | 17 L/min |
| Max Pressure | 270 mbar (water) |
| Heating Power | 1.3–1.5 kW (voltage-dependent) |
| Pump Inlet/Outlet Diameter | 6 mm / 11 mm |
| Safety Features | Adjustable overtemperature cutoff, float-level switch, audible alarm |
| Compliance | Designed for GLP-compliant laboratory environments |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | JB Aqua 2/2s/5/12/18/26/Dual Plus |
| Quotation | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | JB Aqua Plus |
| Price | Upon Request |
| Temperature Range | Ambient + 5°C to 98°C |
| Temperature Setting Range | 10–99°C (0.1°C resolution) |
| Stability | ±1.0°C |
| Control Type | Analog dial |
| Heating Power | 0.13–2.1 kW |
| Working Volume | 2–34 L (including dual-chamber 5+12 L variant) |
| Construction | Stainless steel tank and housing |
| Safety Features | Adjustable overheat cutoff, dry-run protection |
| Standard Accessories | Polycarbonate dome lid, insulated base |
| Drain Valve | Optional on JB Aqua 12 Plus, 18 Plus, 26 Plus (introduced 2010) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GD100-R |
| Pricing | Upon Request |
| Temperature Range | 0–100 °C |
| Stability | ±0.1 °C |
| Refrigeration Power @ 20 °C | 250–1100 W (model-dependent) |
| Bath Volumes | 5–20 L |
| Drain Port | Optional (GD100-R2/R4/R5) |
| Optional Accessories | VTP1/VTP2 Vertical Turbine Pumps |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TXSEP |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DB-4S |
| Price | Upon Request |
| Temperature Setting Range | +25 °C to +100 °C |
| Temperature Control Range | Ambient +5 °C to +100 °C |
| Stability @37 °C | ±0.03 °C |
| Uniformity @37 °C | ±0.12 °C |
| Setpoint Resolution | 0.1 °C |
| Display | Dual-line LCD |
| Heating Time (25 °C → 37 °C) | 4 min |
| Heating Time (25 °C → 60 °C) | 10 min |
| Heating Time (25 °C → 100 °C) | 40 min |
| Capacity | 32 × 0.2 mL microtubes or 4 × 0.2 mL PCR strip tubes |
| Timer Range | 1–96 h |
| Input Voltage | 12 V DC |
| Input Current | 0.85 A |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PSC96 |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Heating Time to 100 °C | ≤1 min |
| Block Configuration | 96-well compatible aluminum heating block |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PSC18 |
| Pricing | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PRS-14 |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1 °C |
| Heating Time to 100 °C | ≤1 min |
| Platform Motion | Orbital, 25 mm Diameter |
| Speed Range | 100–1,200 rpm |
| Speed Accuracy | ±2 rpm |
| Platform Size | 260 × 240 mm |
| Max Load Capacity | 3 kg |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Safety Certifications | CE, RoHS, IEC 61010-1 |
| Brand | Grant |
|---|---|
| Origin | UK |
| Model | TC120 |
| Temperature Range | −20 °C to +100 °C |
| Stability | ±0.05 °C (at 70 °C, per DIN 12876) |
| Uniformity | ±0.1 °C (at 70 °C, per DIN 12876) |
| Setpoint Resolution | 0.1 °C |
| Display | 4-digit LED |
| Timer Range | 1 min to 99 h 59 min |
| Preset Temperatures | 4 (1 active + 3 recallable) |
| Built-in Circulation Pump | Max. flow 16 L/min, max. pressure 210 mbar |
| Heating Power | 1.3 kW (230 V), 1.4 kW (120 V) |
| Safety Features | Over-temperature cut-off, low-level float switch, audible/visual alarm |
| Calibration | User-adjustable two-point calibration |
| External Probe Compatibility | TXPEP/TXSEP optional |
| Communication Interface | USB and RS232 |
| Compliance | DIN 12876 Class I |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GD120 |
| Pricing | Available Upon Request |
| Temperature Range Options | 0–120 °C (S5/S12/S18), –15–120 °C (S26/S38) |
| Temperature Stability (DIN 58966 @37 °C) | ±0.02 °C |
| Temperature Uniformity (@37 °C) | ±0.05 °C |
| Setpoint Resolution | 0.1 °C |
| Display | 4-digit, 13 mm LED |
| Pre-set Temperature Memory | 4 values |
| Dual-Point Calibration | Yes |
| Heating Power | 1.4 kW (240 V), 1.3 kW (115 V) |
| Pump Max Pressure | 270 mbar (water), Max Flow Rate: 17 L/min |
| Tubing Port ID/OD | 6/11 mm |
| Safety Features | Adjustable overtemperature cut-out, float-switch level protection |
| Electrical Supply | 230 V / 1.5 kW (50 Hz), 120 V / 1.4 kW (60 Hz) |
| Bath Volumes | 5 L (S5), 12 L (S12), 18 L (S18), 26 L (S26), 38 L (S38) |
| Top Opening Dimensions (L×W) | 150×150 mm (S5), 210×300 mm (S12), 390×300 mm (S18/S26), 580×300 mm (S38) |
| Minimum/Maximum Liquid Depth | 80/140 mm (S5/S12), 70/130 mm (S18), 120/180 mm (S26/S38) |
| Internal Tank Dimensions (L×W×H) | 300×150×150 mm (S5), 325×300×150 mm (S12), 505×300×150 mm (S18), 505×300×200 mm (S26), 690×300×200 mm (S38) |
| External Dimensions (L×W×H) | 325×175×175 mm (S5), 350×325×175 mm (S12), 530×325×225 mm (S18/S26), 720×325×225 mm (S38) |
| External Dimensions with Controller (L×W×H) | 325×175×355 mm (S5), 350×325×355 mm (S12), 530×325×405 mm (S18/S26), 720×325×405 mm (S38) |
| Optional Immersion Chillers | C1G (all models), C2G (S26 & S38) |
| Origin | United Kingdom |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | AQBT5 |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Optima-R Series |
| Pricing | Available Upon Request |
| Temperature Range | −20 to 100 °C |
| Stability | ±0.1 °C |
| Max Flow Rate | 17 L/min |
| Max Pressure | 270 mbar |
| Refrigeration Capacity @ 20 °C | 250–1100 W (model-dependent) |
| Bath Volumes | 5–20 L |
| Drain Port | Standard on GD120-R2 to GD120-R5 |
| Optional Accessories | VTP1/VTP2 Vertical Turbine Pumps |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FH16D |
| Price | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SBB Aqua Plus |
| Pricing | Available Upon Request |
| Temperature Range | Ambient +5°C to 100°C |
| Power Supply | 220–240 V AC |
| Heating Power | 1.5 kW (SBB AQUA 5 PLUS, SBB AQUA 12 PLUS), 2.0 kW (SBB AQUA 18 PLUS, SBB AQUA 26 PLUS) |
| Capacity | 5 L, 12 L, 18 L, or 26 L |
| Working Chamber Dimensions (L×W×D) | 270×215×385 mm, 270×390×385 mm, 270×570×385 mm, or 300×570×385 mm |
| Control Type | Analog Power Regulation |
| Safety Feature | Adjustable Over-Temperature Cut-Off Protection |
| Standard Accessory | Drip-Resistant Polycarbonate Lid |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PB1 |
| Quotation | Available Upon Request |
| Bath Volume | 3.5 L |
| Temperature Range | Ambient +5°C to 60°C |
| Setpoint Range | 10°C to 60°C |
| Temperature Stability (DIN 58966) | ±0.3°C at 37°C |
| Control Method | Analog Dial Control |
| Power Supply | 120 V or 230 V AC |
| Heating Power | 0.3 kW |
| External Dimensions (L×W×D) | 225 × 120 × 80 mm |
| Safety Feature | Fixed-Temperature Cut-Off (DIN 12876 Compliant) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GR150-S/P |
| Pricing | Upon Request |
| Brand | Grant Instruments |
|---|---|
| Origin | United Kingdom |
| Model | RS14 |
| Material | 316 Stainless Steel |
| Load Capacity | 20 kg |
| Platform Dimensions | 300 × 250 mm |
| Height Adjustment | Fixed at 140 mm |
| Foot Design | Non-slip rubber pads |
| Compliance | CE-marked, ISO 9001-manufactured components |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QB-ACC |
| Temperature Range | Ambient +10°C to 150°C |
| Temperature Accuracy | ±0.3°C at 37°C, ±0.5°C across full range |
| Heating Time | ≤12 min (from 25°C to 100°C) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T100-MST20 |
| Price | Upon Request |
| Temperature Range | RT + 5°C to 100°C |
| Temperature Stability | ±0.05°C |
| Display | 4-digit LED |
| Temperature Resolution | 0.1°C |
| Heating Power | 1.3 kW (230 V) / 1.4 kW (120 V) |
| Bath Opening | 240 × 210 mm |
| Bath Capacity | 20 L |
| Minimum/Maximum Liquid Depth | 185 / 225 mm |
| Total Power Consumption | 1.4 kW (230 V, 50/60 Hz) / 1.5 kW (120 V, 50/60 Hz) |
| Max. Gerber Fat Meter Capacity | 36 units (3 × H1-25M racks, 12 per rack) |
| Safety Features | Fixed overtemperature cut-off, low-level fluid alarm |
| Control System | Detachable digital PID controller with adaptive tuning, 3 programmable setpoints, flywheel + dual-button interface |
| Construction | Acid-resistant stainless steel inner tank and outer housing, removable stainless steel lid with ergonomic handles |
| Immersed Components | Acid-resistant heater, float switch, and Pt100 temperature sensor |
| Calibration | User-executable self-calibration routine |